Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 156497 dokumen yang sesuai dengan query
cover
Ida Juita Halim
"

Latar Belakang. Untuk menanggulangi nyeri saat penyuntikan jarum spinal dapat digunakan dua cara yaitu dengan cara non-farmakologis seperti melakukan manuver Valsalva dan cara farmakologis seperti memberikan obat anestesi sebelum penyuntikan. Menurut studi terdahulu di RSUPN-CM telah diketahui bahwa skala nyeri yang diperoleh yaitu VAS 0 (0-3) untuk kelompok EMLA dan VAS 0 (0-4) untuk kelompok vapocoolant spray saat penyuntikan jarum spinal. Untuk itu, peneliti ingin meneliti mengenai cara non farmakologis dengan membandingkan efektivitas manuver Valsalva dan kontrol dalam menurunkan derajat nyeri saat penyuntikan jarum spinal.

Metode. Penelitian ini menggunakan desain uji eksperimental klinis pada 70

pasien dengan 35 pasien pada masing-masing kelompok manuver Valsalva dan kontrol selama Januari-April 2019. Subjek penelitian adalah pasien wanita yang akan menjalani brachiterapi untuk pertama kali dengan pembiusan spinal. Efektifitas anestesia dinilai dengan skala nyeri VAS dan gerakan pasien.

Hasil. Skala nyeri yang diperoleh yaitu VAS 10mm (0-60) untuk kelompok manuver Valsalva dan VAS 30mm (0-60) untuk kelompok kontrol. Terdapat perbedaan bermakna antara skor VAS kelompok manuver valsalva dengan kelompok kontrol menurut uji Mann-Whitney dengan nilai p<0.001. Untuk gerakan pasien, kelompok Valsalva yang bergerak hanya 7 orang (20%) sedangkan dari kelompok kontrol yang bergerak 17 subjek (48.6%). Terdapat perbedaan proporsi gerak antara kelompok manuver valsalva dengan kelompok kontrol menurut uji Chi-square dengan nilai p=0.012

Kesimpulan. Terdapat perbedaan signifikan skala nyeri VAS dan gerakan pasien antara kelompok Manuver Valsalva dan kontrol saat penyuntikan jarum spinal.


Background. There are two methods to cope with pain during spinal injection, by non-pharmacologic such as doing Valsalva maneuver and by pharmacologic like giving anesthesia before the injection. Based on the previous study in RSUPN-CM stated that VAS 0 (0-3) for EMLA group and VAS 0 (0-4) for vapocoolant spray group during spinal puncture. The study aimed at comparing the effectiveness of Valsalva maneuver as non pharmacological approach and control in reducing pain during spinal injection.

Method. This was an experimental study on 70 subjects with 35 subjects treated with Valsalva maneuver and 35 subjects treated as control from January to April 2019. Research subjects were female who will undergo brachytherapy for the first time with spinal anesthesia. The effectiveness of pain was assessed by using Visual Analogue Scale (VAS) and patient movement during the surgery.

Results. This study found that pain scale obtained were VAS 10 (0-60) for Valsalva Maneuver group and VAS 30 (0-60) for control group. There was significant difference between two groups for pain scale according to Mann-Whitney test with p-value <0.001. For patient movement, the movement was reported in seven patients in Valsalva manuver group and 17 patients in control group. Based on chi-square test, there was significant differences between two groups, with p-value 0.012.

Conclusions. There were significant differences in VAS pain scale and patient movement between Manuver Valsalva group and control group in reducing pain during spinal injection

"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
T55583
UI - Tesis Membership  Universitas Indonesia Library
cover
Emi Setyaningsih
"Insersi jarum spinal dapat menimbulkan nyeri sehingga perlu dilakukan teknik stimulasi kompres dingin guna menurunkan intensitas nyeri yang dialami. Penelitian ini bertujuan untuk mengidentifikasi efektivitas kompres dingin dalam menurunkan intensitas nyeri insersi jarum spinal pada prosedur spinal anestesi. Desain yang digunakan adalah quasy experimental dengan pendekatan post test only design non equivalent control group. Sampel terdiri dari 72 pasien dewasa yang terbagi atas 36 orang kelompok intervensi dan 36 orang kelompok kontrol.
Analisis data untuk mengetahui perbedaan rerata kelompok perlakuan (kompres dingin) dan kelompok kontrol (standar prosedur) dengan intensitas nyeri dan menganalisis hubungan variabel jenis kelamin dan pengalaman nyeri insersi spinal dengan intensitas nyeri menggunakan uji Mann Whitney. Analisis data untuk mengetahui hubungan variabel usia, ukuran jarum spinal dan kecemasan dilakukan uji Kruskal Wallis.
Hasil analisis menunjukkan terdapat perbedaan bermakna antara kelompok perlakuan (kompres dingin) dan kelompok kontrol (standar prosedur) dan hubungan bermakna antara variabel kecemasan dengan intensitas nyeri (p<0,05). Hasil analisis menunjukkan tidak terdapat hubungan bermakna pada variabel usia, jenis kelamin, pengalaman nyeri insersi dan ukuran jarum spinal (p>0,05). Dapat disimpulkan kompres dingin merupakan intervensi yang terbukti efektif untuk menurunkan intensitas nyeri insersi jarum spinal pada prosedur spinal anestesi.

Spinal needle insertion may cause pain hence cold compress stimulation technique to reduce the intensity of the pain is required. This study aims to identify the effectiveness of cold compress in reducing the intensity of spinal needle insertion pain in spinal anesthesia procedures. The design used was quasy experimental with post test only design non equivalent control group approach. The sample consisted of 72 adult patients divided into 36 intervention groups and 36 control groups.
Data analysis is to obtain the difference average of treatment group (cold compress) and control group (standard procedure) with pain intensity and analyze the connection of gender and spinal insertion pain variables and the intensity of pain using Mann Whitney test. Data analysis to obtain the correlation of age, spinal needle size and anxiety variables was conducted using Kruskal Wallis test.
Analysis results show that there are significant differences between treatment group (cold compress) and control group (standard procedure) and significant relationship between anxiety variables with pain intensity (p <0.05). The results show no significant association in age, sex, insertion pain experience and spinal needle size (p> 0.05). It can be concluded that cold compress is an effective intervention to decrease the intensity of spinal needle insertion pain in spinal anesthesia procedure.
"
Depok: Fakultas Ilmu Keperawatan Universitas Indonesia, 2018
T49253
UI - Tesis Membership  Universitas Indonesia Library
cover
Berial Dewin Marzaini
"ABSTRAK
Latar Belakang. Salah satu cara untuk mengurangi nyeri saat penyuntikan dalam prosedur medis adalah dengan pemberian anestesia. Krim EMLA sering digunakan untuk anestetik lokal pada penyuntikan spinal, tetapi memiliki onset kerja yang cukup lama sehingga kurang cocok untuk pasien rawat jalan. Vapocoolant spray yang berisi etil klorida memiliki berbagai keuntungan yaitu onsetnya yang cepat, aman, biaya rendah, dan banyak tersedia sehingga cocok digunakan sebagai anestesia pada pasien one-day care. Penelitian ini ingin mengetahui efektifitas vapocoolant spray dan krim EMLA dalam menurunkan nyeri pada tindakan anestesia spinal. Metode. Penelitian ini menggunakan desain uji eksperimental klinis pada 94 pasien dengan 47 pasien pada masing-masing kelompok EMLA dan vapocoolant spray. Efektifitas anestesia dinilai dengan skala nyeri VAS dan gerakan pasien. Hasil. Dengan menggunakan anestesia, skala nyeri yang diperoleh yaitu VAS 0 0-3 untuk kelompok EMLA dan VAS 0 0-4 untuk kelompok vapocoolant spray. Tidak terdapat perbedaan bermakna pada kedua kelompok untuk data skala nyeri menurut uji Mann-Whitney. Untuk gerakan pasien, pergerakan saat penyuntikan hanya terjadi pada satu 2,1 pasien pada kelompok EMLA dan satu 2,1 pasien pada kelompok vapocoolant spray. Berdasarkan uji Fisher, tidak ditemukan perbedaan bermakna untuk gerakan pasien antara kedua zat anestetik tersebut. Kesimpulan. Tidak ditemukan perbedaan skala nyeri VAS dan gerakan pasien antara kelompok krim EMLA dan vapocoolant spray pada tindakan anestesia spinal pada pasien one-day care. Diperlukan penelitian lebih lanjut mengenai penggunaan vapocoolant spray dalam berbagai prosedur dan praktik klinik kedokteran.

ABSTRACT
Background. One way to reduce pain during injection in medical procedures is by administering anesthesia. EMLA cream is often used for local anesthesia in spinal injections, but it has long onset of action so less suitable for outpatients. Vapocoolant spray containing ethyl chloride has numerous advantages, such as fast onset, safe, low cost, and widely available, so suitable as local anesthetic for one day care patients. This study aimed to find the effectiveness of vapocoolant spray and EMLA in reducing pain for local anesthesia procedure. Method. This study used an experimental design on 94 patients which 47 patients in each group were treated with EMLA and vapocoolant spray consecutively. Effectiveness of anesthesia was assessed by VAS pain scale and patient movement. Results. By using anesthesia, pain scale obtained were VAS 0 0 3 for EMLA group and VAS 0 0 4 for vapocoolant spray group. There was no significant difference between two groups for pain scale according to Mann Whitney test. For patient movement, the movement was reported only in one 2.1 patient in EMLA group and one 2.1 patient in vapocoolant spray group. Based on Fisher 39 s test, there was no significant differences between the two group for movement. Conclusions. There were no differences in VAS pain scale and patient movement between EMLA cream and vapocoolant spray for spinal anesthesia in one day care patients. Further research is needed for the use of vapocoolant spray in various medical procedures and clinical practice."
2017
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Berial Dewin Marzaini
"ABSTRAK
Latar Belakang. Salah satu cara untuk mengurangi nyeri saat penyuntikan dalam prosedur medis adalah dengan pemberian anestesia. Krim EMLA sering digunakan untuk anestetik lokal pada penyuntikan spinal, tetapi memiliki onset kerja yang cukup lama sehingga kurang cocok untuk pasien rawat jalan. Vapocoolant spray yang berisi etil klorida memiliki berbagai keuntungan yaitu onsetnya yang cepat, aman, biaya rendah, dan banyak tersedia sehingga cocok digunakan sebagai anestesia pada pasien one-day care. Penelitian ini ingin mengetahui efektifitas vapocoolant spray dan krim EMLA dalam menurunkan nyeri pada tindakan anestesia spinal. Metode. Penelitian ini menggunakan desain uji eksperimental klinis pada 94 pasien dengan 47 pasien pada masing-masing kelompok EMLA dan vapocoolant spray. Efektifitas anestesia dinilai dengan skala nyeri VAS dan gerakan pasien. Hasil. Dengan menggunakan anestesia, skala nyeri yang diperoleh yaitu VAS 0 0-3 untuk kelompok EMLA dan VAS 0 0-4 untuk kelompok vapocoolant spray. Tidak terdapat perbedaan bermakna pada kedua kelompok untuk data skala nyeri menurut uji Mann-Whitney. Untuk gerakan pasien, pergerakan saat penyuntikan hanya terjadi pada satu 2,1 pasien pada kelompok EMLA dan satu 2,1 pasien pada kelompok vapocoolant spray. Berdasarkan uji Fisher, tidak ditemukan perbedaan bermakna untuk gerakan pasien antara kedua zat anestetik tersebut. Kesimpulan. Tidak ditemukan perbedaan skala nyeri VAS dan gerakan pasien antara kelompok krim EMLA dan vapocoolant spray pada tindakan anestesia spinal pada pasien one-day care. Diperlukan penelitian lebih lanjut mengenai penggunaan vapocoolant spray dalam berbagai prosedur dan praktik klinik kedokteran.

ABSTRACT
Background. One way to reduce pain during injection in medical procedures is by administering anesthesia. EMLA cream is often used for local anesthesia in spinal injections, but it has long onset of action so less suitable for outpatients. Vapocoolant spray containing ethyl chloride has numerous advantages, such as fast onset, safe, low cost, and widely available, so suitable as local anesthetic for one day care patients. This study aimed to find the effectiveness of vapocoolant spray and EMLA in reducing pain for local anesthesia procedure. Method. This study used an experimental design on 94 patients which 47 patients in each group were treated with EMLA and vapocoolant spray consecutively. Effectiveness of anesthesia was assessed by VAS pain scale and patient movement. Results. By using anesthesia, pain scale obtained were VAS 0 0 3 for EMLA group and VAS 0 0 4 for vapocoolant spray group. There was no significant difference between two groups for pain scale according to Mann Whitney test. For patient movement, the movement was reported only in one 2.1 patient in EMLA group and one 2.1 patient in vapocoolant spray group. Based on Fisher 39 s test, there was no significant differences between the two group for movement. Conclusions. There were no differences in VAS pain scale and patient movement between EMLA cream and vapocoolant spray for spinal anesthesia in one day care patients. Further research is needed for the use of vapocoolant spray in various medical procedures and clinical practice."
2017
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Sidharta Kusuma Manggala
"[Latar Belakang: Posisi pasien selama tindakan anestesia spinal menentukan keberhasilan penempatan jarum spinal. Traditional sitting position (TSP) merupakan posisi standar untuk anestesia spinal, namun angka keberhasilannya masih cukup rendah. Crossed leg sitting position (CLSP) merupakan salah satu posisi alternatif dalam anestesia spinal yang memiliki kelebihan berupa derajat fleksi lumbal yang lebih besar. Penelitian ini bertujuan untuk membandingkan CLSP dan TSP terhadap keberhasilan penempatan jarum spinal pada pasien bedah urologi.
Metode: Penelitian ini adalah uji klinik acak tidak tersamar terhadap pasien yang menjalani anestesia spinal untuk prosedur urologi pada bulan Maret-April 2015 di RSUPN dr. Cipto Mangunkusumo. Setelah mendapatkan persetujuan izin etik dari Komite Etik Penelitian Kesehatan FKUI-RSCM, sebanyak 138 subjek dialokasikan ke dalam dua kelompok posisi penusukan jarum spinal yaitu kelompok CLSP dan TSP. Proporsi keberhasilan penempatan jarum spinal di rongga subarakhnoid, kemudahan perabaan landmark, dan jumlah needle-bone contact pada kedua kelompok kemudian dinilai.
Hasil: Enam subjek masuk kriteria pengeluaran berupa kegagalan penempatan jarum spinal setelah lebih dari sembilan kali percobaan. Tersisa 132 subjek, 67 subjek pada kelompok CLSP dan 65 subjek pada kelompok TSP, yang berhasil menyelesaikan penelitian. Keberhasilan penempatan jarum spinal secara one shot pada kelompok CLSP dan TSP tidak berbeda bermakna (64.2% vs 53.8%, p=0.227). Kemudahan perabaan landmark pada kelompok CLSP berbeda bermakna dengan TSP (94% vs 75%, p=0.003). Jumlah needle-bone contact pada kedua kelompok tidak berbeda bermakna (p=0.337).
Simpulan: Keberhasilan penempatan jarum spinal pada kelompok CLSP tidak berbeda bermakna dibandingkan dengan keberhasilan penempatan jarum spinal pada kelompok TSP pada pasien bedah urologi.;Background: Patient position during spinal anesthesia plays a major role in determining the success of spinal needle insertion to subarachnoid space. Traditional sitting position (TSP) is a standard position for spinal anesthesia, but the success rate for spinal anesthesia in TSP is still quite low. Crossed leg sitting position (CLSP) is one of the alternative positions in spinal anesthesia, which can increase the degree of lumbar flexion. This study aimed to compare CLSP and TSP to the successful insertion of spinal needle in urologic surgery patients.
Methods: This study was a non-blinded randomized controlled trial in patients undergoing spinal anesthesia for urologic procedures between March-April 2015 in RSUPN dr. Cipto Mangunkusumo. After obtaining approval from FKUI-RSCM Ethical Committee, 138 subjects were allocated into two groups, CLSP group and TSP group. The proportion of successful spinal needle insertion to the subarachnoid space, ease of landmark palpation, and the number of needle-bone contact in both groups were then analyzed and assessed.
Result: Six subjects met dropout criteria, which was failure of obtaining successful spinal needle insertion after nine consecutive redirections. The remaining 132 subjects, 67 subjects in the CLSP group and 65 subjects in TSP group, successfully completed the study. The proportion of successful spinal needle insertion in a one-time shot, was not significantly different between CLSP and TSP group (64.2% vs. 53.8%, p = 0227). Ease of landmark palpation in CLSP group was significantly different with TSP group (94% vs. 75%, p = 0.003). The number of needle-bone contact in both groups was not significantly different (p = 0337).
Conclusion: The proportion of successful spinal needle insertion in CLSP group was not significantly different compared to TSP group for urologic surgery patients.;Background: Patient position during spinal anesthesia plays a major role in determining the success of spinal needle insertion to subarachnoid space. Traditional sitting position (TSP) is a standard position for spinal anesthesia, but the success rate for spinal anesthesia in TSP is still quite low. Crossed leg sitting position (CLSP) is one of the alternative positions in spinal anesthesia, which can increase the degree of lumbar flexion. This study aimed to compare CLSP and TSP to the successful insertion of spinal needle in urologic surgery patients.
Methods: This study was a non-blinded randomized controlled trial in patients undergoing spinal anesthesia for urologic procedures between March-April 2015 in RSUPN dr. Cipto Mangunkusumo. After obtaining approval from FKUI-RSCM Ethical Committee, 138 subjects were allocated into two groups, CLSP group and TSP group. The proportion of successful spinal needle insertion to the subarachnoid space, ease of landmark palpation, and the number of needle-bone contact in both groups were then analyzed and assessed.
Result: Six subjects met dropout criteria, which was failure of obtaining successful spinal needle insertion after nine consecutive redirections. The remaining 132 subjects, 67 subjects in the CLSP group and 65 subjects in TSP group, successfully completed the study. The proportion of successful spinal needle insertion in a one-time shot, was not significantly different between CLSP and TSP group (64.2% vs. 53.8%, p = 0227). Ease of landmark palpation in CLSP group was significantly different with TSP group (94% vs. 75%, p = 0.003). The number of needle-bone contact in both groups was not significantly different (p = 0337).
Conclusion: The proportion of successful spinal needle insertion in CLSP group was not significantly different compared to TSP group for urologic surgery patients., Background: Patient position during spinal anesthesia plays a major role in determining the success of spinal needle insertion to subarachnoid space. Traditional sitting position (TSP) is a standard position for spinal anesthesia, but the success rate for spinal anesthesia in TSP is still quite low. Crossed leg sitting position (CLSP) is one of the alternative positions in spinal anesthesia, which can increase the degree of lumbar flexion. This study aimed to compare CLSP and TSP to the successful insertion of spinal needle in urologic surgery patients.
Methods: This study was a non-blinded randomized controlled trial in patients undergoing spinal anesthesia for urologic procedures between March-April 2015 in RSUPN dr. Cipto Mangunkusumo. After obtaining approval from FKUI-RSCM Ethical Committee, 138 subjects were allocated into two groups, CLSP group and TSP group. The proportion of successful spinal needle insertion to the subarachnoid space, ease of landmark palpation, and the number of needle-bone contact in both groups were then analyzed and assessed.
Result: Six subjects met dropout criteria, which was failure of obtaining successful spinal needle insertion after nine consecutive redirections. The remaining 132 subjects, 67 subjects in the CLSP group and 65 subjects in TSP group, successfully completed the study. The proportion of successful spinal needle insertion in a one-time shot, was not significantly different between CLSP and TSP group (64.2% vs. 53.8%, p = 0227). Ease of landmark palpation in CLSP group was significantly different with TSP group (94% vs. 75%, p = 0.003). The number of needle-bone contact in both groups was not significantly different (p = 0337).
Conclusion: The proportion of successful spinal needle insertion in CLSP group was not significantly different compared to TSP group for urologic surgery patients.]"
Fakultas Kedokteran Universitas Indonesia, 2015
SP-PDF
UI - Tugas Akhir  Universitas Indonesia Library
cover
Desy Januarrifianto
"Latar Belakang: Anestesia spinal pada wanita hamil sangat dipengaruhi oleh posisi pasien. Pendant position merupakan posisi yang baru diperkenalkan pada laporan kasus. Penelitian ini bertujuan untuk membandingkan keberhasilan penempatan jarum spinal pada usaha pertama antara pendant position dengan traditional sitting position untuk pasien yang menjalani pembedahan Sesar.
Metode: Penelitian ini adalah uji klinik Randomized Controlled Trial (RCT), dilakukan secara terbuka (tidak tersamar). Subjek dilakukan randomisasi untuk menentukan perlakuan pendant position atau traditional sitting position. Keberhasilan penempatan jarum spinal dinilai dari jumlah usaha, jumlah kontak tulang dan lama waktu penempatan jarum spinal.
Hasil: Sebanyak 308 subjek penelitian, tidak ada yang termasuk kriteria penolakan dan pengeluaran. Keberhasilan penempatan jarum spinal pada usaha pertama untuk pendant position lebih baik (142 subjek (92%) vs 121 subjek (78%), p 0,001), total jumlah kontak tulang lebih sedikit (185 vs 421, p<0,001) dan median lama waktu yang dibutuhkan untuk penempatan jarum spinal lebih cepat ( 9 (4-350) vs 12 (5-486) detik, p<0,001) jika dibandingkan dengan traditional sitting position.
Simpulan: Pendant position lebih baik dalam hal keberhasilan penempatan jarum spinal pada usaha pertama untuk pasien yang menjalani pembedahan Sesar jika dibandingkan traditional sitting position.

Background: Spinal anesthesia in pregnant women is strongly influenced by the position of the patient. Pendant position is a new position introduced in the case report. This study aimed to compare the successful placement of spinal needle on the first attempt between pendant position and traditional sitting position for patients who underwent sectio Caesarean.
Methods: The study was a randomized controlled trial (RCT), conducted openly (not blind). Subject randomization to determine treatment pendant position or traditional sitting position. The successful placement of spinal needle judged from the number of first attempt, the amount of bone contact and the duration of the placement of spinal needle.
Results: A total of 308 subjects, none of which include criteria for exclusion and drop out. The successful placement of spinal needle on the first attempt of pendant position is better (142 subjects (92%) vs. 121 subjects (78%), p 0.001), the total amount of bone contact is less (185 vs. 421, p <0.001) and the median length of time required for placement of spinal needle is faster (9 (4-350) vs. 12 (5-486) seconds, p <0.001) when compared to the traditional sitting position.
Conclusion: Pendant position is better in terms of the successful placement of spinal needle on the first attempt for a patient who underwent sectio Caesarean compared to traditional sitting position.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2014
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Winanda Amorosso
"Kebakaran lahan gambut terjadi secara berulang di Indonesia. Berbagai penelitian telah dilakukan untuk menemukan metode pemadaman kebakaran membara gambut yang paling efisien. Penelitian ini berfokus pada supresi gambut yang mengalami kebakaran membara dengan metode injeksi busa dalam skala laboratorium. Eksperimen dilakukan untuk mengetahui efektivitas supresi dengan metode injeksi busa pada hotspot gambut dengan variasi sampel yang berbeda, antara lain sampel dari daerah Palangkaraya, Kalimantan Tengah, pada koordinat 2°17'21.9"S 114°01'57.3"E dan Kabupaten Tanjung Timur, Jambi pada koordinat 01°14'11.227"S 103°35'4.851"E. Sementara busa yang digunakan adalah busa dengan konsentrasi larutan 1 %. Pada proses eksperimen, sampel gambut akan dituangkan ke dalam reaktor dengan ukuran 200 mm x 200 mm x 100 mm yang dindingnya dilapisi isolator calcium silicate board dan dilengkapi coil heater yang dipanaskan selama 60 menit dengan daya 100 W. Temperatur kedalaman, massa, dan temperatur permukaan sampel masing-masing diukur dengan termokopel, load cell, dan kamera termal. Proses injeksi busa dilakukan saat termokopel pada kedalaman terbawah mengalami mencapai temperatur minimal 215°C atau mengalami kebakaran membara. Busa diinjeksi menggunakan jarum injeksi yang ditancapkan di tengah reaktor dengan kedalaman 100 mm dari permukaan reaktor. Jarum terhubung dengan alat injeksi terintegrasi dengan kecepatan aliran busa 100 ml/min. Hasil penelitian menunjukkan busa secara efektif dapat mensupresi gambut pada variasi sampel yang berbeda.

Peatland fires occur repeatedly in Indonesia. Various studies have been conducted to find the most efficient method of extinguishing peat smoldering fires. This research focuses on extinguishing peat smoldering fires by foam injection method on a laboratory scale. Experiments were conducted to determine the effectiveness of suppression by the foam injection method on peat hotspots with different sample variations, including samples from the Palangkaraya area, Central Kalimantan, at coordinates 2°17'21.9"S 114°01'57.3"E and Tanjung Timur Regency, Jambi at coordinates 01°14'11.227"S 103°35'4.851"E. While the foam used was foam with a solution concentration of 1%. In the experimental process, peat samples will be poured into a reactor with a size of 200 mm x 200 mm x 100 mm whose walls are covered with a calcium silicate board insulator and equipped with a coil heater heated for 60 minutes with a power of 100 W. Depth temperature, mass, and surface temperature of the sample are each measured by a thermocouple, load cell, and thermal camera. The foam injection process is carried out when the thermocouple at the bottom depth reaches a temperature of at least 215 °C or undergoes smouldering. The foam is injected using an injection needle stuck in the center of the reactor with a depth of 100 mm from the surface of the reactor. The needle is connected with an integrated injection device with a foam flow speed of 100 ml / min. The results showed that foam can effectively suppress peat at different sample variations.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ria Veni Susanti
"Latar belakang: Anestesia obstetrik termasuk anestesia yang memiliki risiko tinggi dalam praktik anestesia. Perubahan fisiologi ibu selama kehamilan dan keberadaan janin merupakan tantangan yang unik untuk anestesia obstetrik. Baik kehamilan normal maupun obesitas, sama-sama mengalami perubahan anatomi dan fisiologi yang signifikan dan pengaruh anestesi yang hampir sama. Belum ada penelitian sebelumnya yang membandingkan tingkat keberhasilan insersi jarum spinal dalam posisi duduk bersila antara ibu hamil obes maupun ibu hamil bukan obes yang menjalani seksio sesarea. Penelitian ini dilakukan di RSCM dan RSU Tangerang antara bulan Juli sampai Agustus 2016.
Tujuan: Penelitian ini bertujuan untuk membandingkan tingkat keberhasilan insersi jarum spinal pada posisi duduk bersila antara ibu hamil obes dan ibu hamil bukan obes yang menjalani seksio sesarea.
Metode: Penelitian ini merupakan open label study yaitu uji klinis terbuka dimana perlakuan sama-sama diketahui oleh subjek maupun pelaku anestesia. Ibu hamil yang menjalani seksio sesarea dibagi menjadi dua kelompok yaitu obes O dan bukan obes NO . Pada keduanya dilakukan insersi jarum spinal dalam posisi duduk bersila. Pada penelitian ini dilakukan penilaian tingkat keberhasilan insersi jarum spinal, persentase keberhasilan insersi jarum spinal, banyaknya kontak jarum spinal dengan tulang, dan kekerapan tusukan pembuluh darah.
Hasil: Dari136 subjek penelitian, tidak ada yang termasuk kriteria penolakan dan pengeluaran. Keberhasilan insersi jarum spinal pada kelompok NO adalah 47 subjek 69,12 dan pada kelompok O 45 subjek 66,18. Secara statistik tidak berbeda bermakna antara kelompok NO dan kelompok O pada tingkat keberhasilan insersi jarum spinal p=0,714, jumlah kontak jarum spinal dengan tulang p=0,591, dan kekerapan tertusuknya pembuluh darah pada waktu insersi jarum spinal p=0,282.
Simpulan: Tingkat keberhasilan insersi jarum spinal yang dilakukan dalam posisi duduk bersila pada ibu hamil bukan obes tidak lebih baik jika dibandingkan pada ibu hamil obes.

Background: Obstetric anesthesia is high risk in practice. The physiological changes during pregnancy and fetal wellbeing are unique challenges posed for obstetric anesthesia. Significant changes in anatomy and physiology along with anesthesia considerations are similar in normal and obese pregnancy. Up to this day, there are no studies comparing successful spinal needle insertion rate in cross legged sitting position between obese and non obese parturient undergoing caesarean section. This study was done in RSCM and RSU Tangerang between July August 2016.
Aim: This study aims to compare successful rate of spinal needle insertion in cross legged sitting position between obese and non obese parturient undergoing caesarean section.
Method: This was an open label study, which was an open clinical trial where treatment was known by subjects and anesthesiologist. Parturient undergoing caesarean section were categorized into two groups, which were obese O and non obese NO. Both of the groups had spinal needle insertion in cross legged sitting position. In this study, the variables assessed were the rate of successful spinal needle insertion, the percentage of successful spinal needle insertion, the frequency of spinal needle contact with bone, and the frequency of vein puncture.
Result: All 136 subjects were included in the analysis. The rate of successful spinal needle insertion in the NO group was 47 subjects 69.12 and 45 subjects in the O group 66.18. This result was not statistically significant p 0.714, along with the frequency of spinal needle contact with bone p 0.591 , and the frequency of vein puncture during spinal needle insertion p 0.282.
Conclusion: The rate of successful spinal needle insertion in cross legged sitting position on non obese parturient was not better than on obese parturient.Key Words Spinal needle insertion, cross legged sitting position, obese and non obese parturient, bone contact, vein puncture.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2017
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Henry Agus
"LATAR BELAKANG : Kombinasi anestetik lokal dosis rendah dengan opioid yaitu bupivakain 0,5% hiperbarik 7,5 mg dan 5 mg ditambah fentanil 25 mcg diharapkan keefektifannya untuk memfasilitasi bedah Caesar, yaitu dengan cara menurunkan angka kejadian hipotensi dan kualitas analgesia serta blok motorik yang adekuat.
METODE : 112 pasien hamil usia 18-40 tahun yang akan menjalani bedah Caesar baik cito maupun elektif ASA I-III yang sesuai dengan kriteria inklusi. Randomisasi menjadi 2 kelompok; kelompok I mendapatkan bupivakain 0,5% hiperbarik 7,5 mg ditambah fentanil 25 mcg dan kelompok II mendapatkan bupivakain 0,5% hiperbarik 5 mg ditambah fentanil 25 mcg. Posisi pasien kedua kelompok yaitu posisi duduk dengan pungsi lumbal setinggi L3-4/L4-5.Total volume 2 cc disuntikkan dengan kecepatan 0,2 cc/detik.Kemudian telentang dengan posisi left lateral tilt. Dilakukan pencatatan tekanan darah pada menit ke-3, 6, 9, 12, 15, 20, 30, 40, 50, 60 atau sampai bayi lahir setelah disuntikkannya obat anestetik lokal ke ruang subaraknoid. Dilakukan pencatatan tercapai blok motorik dan sensorik sampai operasi selesai.
HASIL : Keefektifan pada kelompok I 89,3 % dan kelompok II 76,8 %.
KESIMPULAN : Tidak terdapat perbedaan yang bermakna mengenai keefektifan pada kedua kelompok subyek penelitian.

BACKGROUND : the combination of low doses local anesthetics with opioid is 0,5 % hyperbaric bupivacaine 7,5 and 5 mg plus fentanyl 25 mcg is expected to facilitate the effectiveness cesarean that is by way of reducing the incidence of hypotension and the quality of analgesia and motor block adequate.
METHOD : 112 pregnant patients aged 18-40 years who underwent emergency surgery or elective cesarean both ASA I-III corresponding inclusion criteria. Randomization into 2 groups: group 1 receive hyperbaric bupivacaine 0,5 % 7,5 mg plus fentanyl 25 mcg and group 2 get hyperbaric bupivacaine 0,5 % 5 mg plus fentanyl 25 mcg. The position of the two groups are seated position with lumbar puncture as high as L3-4/L4-5. The total volume of 2 ml injected with a speed of 0,2 ml/sec. then supine with left lateral tilt position. Did recording of blood pressure in minute-3, 6, 9, 12, 15, 20, 30, 40, 50, 60 or until the baby was born after injection of local anesthetics into subarachnoid space. Did recording of motor and sensory block achieved until the operation was complete.
RESULT : The effectiveness of the group I was 89,3 % and group II was 76,8 %.
CONCLUSION : There were no significant differences between the two groups regarding the effectiveness of the study subjects.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2013
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Fachrul Jamal Isa
"Telah dilakukan penelitian kekerapan nyeri kepala pada
pasien pasca seksio sesaria dengan analgesia spinal dengan
pensil] di Rumah Sakit Umum Pusat Nasional Cipto Mangunku-
Sejumlah 100 orang pasien yang menjalani operasi seksio
sesaria baik elektif dan darurat dengan status fisis ASA III.
Pasien-pasien ini dibagi dalam dua kelompok [ I dan II].
Kelompok I mendapat jarum spinal 27 tajam, kelompok II mendapat
jarum spinal 27 tumpul [keduanya dari produk UNISIS].
Sebelum dilakukan analgesia spinal semua pasien mendapat
perlakuan yang sama yaitu dipasang jalur intravena dan
diberikan cairan beban ringer laktat sebanyak 500 ml. Kemudian
pasien dibaringkan dalam posisi lateral dikubitus dan
dilakukan pungsi lumbal [L2-3 atau L3-4] dengan pendekatan
tajam].
Setelah operasi semua pasien dibaringkan dalam posisi
datar [horizontal] selama 6 jam dan mendapat cairan rehidrasi
3000 ml/hari untuk hari pertama dan dilakukan wawancara
keluhan nyeri kepala pasca pungsi dura (NKPPD) pada hari
I,III,V, pasca operasi. Pada pasien tersebut juga ditanyakan
keluhan lain, khususnya yang menyertai keluhan NKPPD. Pada
penelitian ini tidak ditemukan komplikasi NKPPD pada operasi
seksio sesaria dengan mempergunakan jarum no.27 tajam maupun
27 tumpul (UNISIS).
Vll sumo Jakarta dan Rumah Sakit Boedi Kemuliaan Jakarta.
median dengan jarum yang dipilih secara acak [tumpul atau
memakai jarum no.27 tajam [Standard] dan 27 tumpul (UNISIS)."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 1995
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>