Dallih Warviyan
"Pelepasan muatan sebagian merupakan salah satu fenomena awal dari kegagalan isolasi. Partial discharge ini disebabkan oleh ketidakhomogenan bahan isolasi yang dapat disebabkan oleh adanya void (rongga udara), tonjolan (protusions) dan contaminants. Pada skripsi ini akan dibahas mengenai perhitungan pelepasan muatan sebagian pada rongga udara yang ada di isolasi EPR.

Internal partial discharge is one of the pre breakdown insulation phenomenons. This is caused by inhomogeneous of the insulation which is caused by voids, protrusions, contaminants. In this paper will be calculated about the internal partial discharge in void within ethyelen propylene rubber insulation. Keyword : void, internal partial discharge, EPR."
Depok: Fakultas Teknik Universitas Indonesia, 2010
S51208
UI - Skripsi Open  Universitas Indonesia Library
cover
Teguh Herbasuki
"Penyambungan kabel tanah 20 kV dengan menggunakan bahan isolasi Ethylene Propylene Rubber (EPR) sering menimbulkan permasalahan karena ada kemungkinan terjebaknya udara didalam rongga diantara lapisan isolasi, yang akan menyebabkan terjadinya medan listrik didalam rongga tersebut. Bila kekuatan medan listrik tersebut melebihi kekuatan tembus udara maka akan terjadi pelepasan muatan sebagian ( partial discharge ) pada isolasi dan lama-kelamaan isolasi mengalami kegagalan dalam fungsinya.
Pelepasan muatan sebagian akan menyebabkan terjadinya kuat medan listrik yang tidak homogen, dengan kekuatan medan listrik udara pada rongga akan lebih besar dari pada kekuatan tembus dalam isolasi. Pelepasan muatan sebagian ini bersifat mengikis dinding rongga, sehingga dinding rongga akan menjadi lebih besar, dengan demikian tingkat kekuatan isolasi akan semakin kecil dan akan memperpendek umur isolasi.
Dalam tesis ini dibahas masalah sejauh mana pengaruh rongga yang terjadi pada isolasi Ethylene Propylene Rubber ( EPR ) dalam sambungan kabel tanah 20 kV terhadap tegangan kritis yang dianggap sebagai penyebab awal terjadinya kegagalan isolasi akibat adanya pelepasan muatan sebagian internal ( internal partial discharge ).

A 20 kV Ethylene Propylene Rubber ( EPR ) insulation underground cable jointing often has air voids, causing electric fields in the voids. If the electrical field is bigger than the air breakdown gradient voltage a partial discharge appear in the insulation, in the long run a breakdown will happen and the insulation will not function.
The partial discharges will cause non homogenuous electric fields with the electric field in the void bigger than the breakdown gradient voltage of the insulation, eroding voids walls causing bigger voids dimensions, smaller insulation strength and shorter insulation ages.
In this thesis the influence of voids in Ethylene Propylene Rubber ( EPR ) insulation underground cable jointing on the critical voltage which is assumed to be the cause of insulation breakdown by internal partial discharge will be discussed.
"
Depok: Fakultas Teknik Universitas Indonesia, 2001
T2795
UI - Tesis Membership  Universitas Indonesia Library
cover
Teguh Herbasuki
Depok: Fakultas Teknik Universitas Indonesia, 2001
TA3181
UI - Tugas Akhir  Universitas Indonesia Library
cover
Bambang Mulyo R.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2003
T40035
UI - Tesis Membership  Universitas Indonesia Library
cover
cover
Fakultas Teknik Universitas Indonesia, 1993
S38455
UI - Skripsi Membership  Universitas Indonesia Library
cover
Setyoadi
"Peluahan parsial/PD (Partial Discharge) merupakan permasalahan yang umum terjadi pada sistem isolasi mesin-mesin atau peralatan bertegangan tinggi. Pada mesin-mesin berputar (generator/motor), PD biasanya terjadi pada isolasi belitan yang terletak di dalam slot inti stator maupun di bagian belitan yang keluar dari inti stator (end winding). PLTP Gunung Salak memiliki 3 unit pembangkit listrik yang dioperasikan oleh Chevron sejak tahun 1997. Setelah dioperasikan selama kurang lebih 9 tahun, pada tahun 2006 untuk pertama kalinya pengecekan visual kondisi isolasi belitan stator generator dapat dilakukan. Hal yang menarik yang diketemukan pada saat itu adalah kerusakan akibat PD terjadi pada lapisan grading dan tingkat kerusakan yang berbeda antara ketiga generator tersebut.
Skripsi ini membahas mengenai analisa permasalahan PD yang terjadi pada isolasi belitan stator generator Unit-4 dengan melakukan analisa komparasi, trending, karakteristik, uji korelasi parameter operasi generator, dan bentuk aktual kerusakan fisik isolasi. Berdasarkan hasil analisa, proses fabrikasi yang kurang baik pada area overlap semikonduktif generator Unit-4 di duga menjadi akar penyebab PD mudah terbentuk pada bagian ini. Seiring dengan proses penuaan isolasi dan meningkatnya rata-rata suhu operasi air pendingin Unit-4 (dari 27 ke 290C), maka akselerasi aktifitas PD diperkirakan terjadi sehingga generator Unit-4 memiliki PD yang lebih tinggi bila dibandingkan dengan Unit-5 dan 6.

Partial Discharge (PD) is a common problem occurring on the insulation system of high voltage machines or equipment. In the rotating machineries (generators/motors), PD usually occurs on the winding insulation installed inside the stator slot or outside the stator core (end winding). PLTP Gunung Salak has 3 power plants which have been being operated by Chevron since 1997. After being in service for 9 years, in the 2006, thorough visual inspection on stator winding insulation could be performed for the first time. The interesting findings at that time were the damaged portion on the grading coating by PD and the different severity level among those three generators.
The focus in this study is to analyze PD problem on the generator Unit-4 winding insulation by conducting analysis of comparison, trending, characteristic, generator operation parameters correlation, and the actual physical damage on insulation. According to the analysis results, improper workmanship on semi conductive overlap layers during fabrication process is predicted to be the root cause that makes PD to be formed easily on this portion. Along with the insulation aging process and the increment of average operating temperature (from 27 to 29) on Unit-4 cooling system, it is suspected that PD activity is being accelerated and thus PD level on Unit-4 generator is higher than Unit-5 and 6.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S43022
UI - Skripsi Open  Universitas Indonesia Library
cover
Josan Putra
"ABSTRAK
Gas Insulated Switchgear (GIS) mulai banyak digunakan pada sistem tenaga listrik. GIS digunakan untuk menggantikan gardu induk konvensional yang memiliki banyak kekurangan. GIS dipilih karena kehandalannya, perawatan yang mudah, dan ukurannya yang kecil hanya 10% dari gardu induk konvensional. Tetapi dengan bentuknya yang compact diperlukan suatu isolasi yang dapat dihandalakan, bekerja cepat ketika terjadi gangguan, atau dapat memutuskan segitiga api ketika terjadi gangguan seperti spark.Menurut penelitian CIGRE Partial dischargemenjadi salah satu penyebab kegagalan isolasi pada GIS. Untuk itu diperlukan pemantauan terhadap Partial discharge di dalam GIS. Pengukuran kualitas GIS Paiton sejak 2010 sampai 2015 menunjukan bahwa Partial discharge sebesar 1 mV/ pC pada unit A menyebabkan penurunan kemurnian gas SF6 sebesar 0.89% per tahun dan menaikan titik embun sebesar 5.80C per tahun. Pada unit B menyebabkan penurunan kemurnian gas SF6 sebesar 0.26% per tahun dan menaikkan titik embun sebesar 9.570C per tahun. Karena itu perlu terjadi pergantian isolasi gas pada unit A setiap 3 tahun sekali dan pada unit B setiap 5 tahun sekali.

ABSTRACT
Gas Insulated Switchgear (GIS) have been widely used in the power system. GIS is used to replace conventional substation has many shortcomings. GIS been reliability, easy maintenance, and its small size of only 10% of conventional substation. But with a compact shape required an isolation that can work quickly when there is disruption, or it can decide when the fire triangle spark interference occurs. According to research CIGRE,partial discharge to be one cause insulation failure in GIS. It is necessary for the monitoring of the partial discharge in GIS. Paiton GIS quality measurements from 2010 to 2015 shows that the partial discharge of 1 mV / pC at unit 1 causes a decrease in SF6 gas purity of 0.89% per year and raise the dew point of 5.80C per year. On unit 2 caused a decrease in SF6 gas purity of 0.26% per year and raise the dew point of 9.570C per year. Because of that, it is necessary to replace the gas isolation of unit A every 3 years and the unit B every 5 years.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S62047
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1999
03 Set a-1
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Sapulete, Renville
"ABSTRAK
Keberadaan Internal Partial Discharge dalam Saluran Kabel Tegangan Menengah disebabkan adanya rongga udara didalam isolasi kabel, yang dalam pembuatannya di pabrik sulit dihindari. Bila besarnya Internal Partial Discharge tersebut sesuai ketentuan Standar kemungkinan kegagalan isolasi (break down) dapat terjadi dalam waktu yang cukup lama antara 30 tahun sampai 100 tahun.
Bila akibat suatu dan lain hal, terjadi `rongga udara baru' dalam kabel tersebut, yang mungkin menimbulkan Internal Partial Discharge yang besar dan akhirnya mempercepat terjadinya kegagalan isolasi. Hal inilah yang diduga terjadi pada gangguan sambungan Saluran Kabel Tegangan Menengah dimana sering terjadi kegagalan isolasi.
Mengingat sulitnya meneliti rongga udara didalam kabel dan diperlukan waktu yang cukup lama, maka penelitian dilakukan dengan membuat lubang pada kabel sebagai tiruan `rongga udara baru' dalam isolasi kabel. Pembuatan lubang dilakukan dengan mengubah kedalaman (d) dan besarnya diameter (D) untuk melihat pengaruh Internal Partial Discharge tersebut. Untuk mencapai kegagalan isolasi kabel dilakukan dengan menaikkan tegangan (Uo) yang diterapkan pada kabel tersebut.
Dari hasil penelitian terlihat semakin besar diameter dan semakin dalam lubang yang dibuat semakin besar Internal Partial Discharge. Kegagalan isolasi terjadi pada scat Internal Partial Discharge mencapai harga tertentu. Dengan mengetahui besarnya Internal Partial discharge pada SKTM dapatlah diantisipasi langkah-langkah yang perlu dilakukan. "
1996
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library