Pengukuran kualitas isolasi GIS Paiton dengan metode pemantauan terhadap partial discharge = Quality measurement of gis paiton insulation with monitoring of partial discharge method

Josan Putra; I Made Ardita Y., supervisor; Amien Rahardjo, examiner; Agus R. Utomo, examiner (Fakultas Teknik Universitas Indonesia, 2016)

 Abstrak

ABSTRAK
Gas Insulated Switchgear (GIS) mulai banyak digunakan pada sistem tenaga listrik. GIS digunakan untuk menggantikan gardu induk konvensional yang memiliki banyak kekurangan. GIS dipilih karena kehandalannya, perawatan yang mudah, dan ukurannya yang kecil hanya 10% dari gardu induk konvensional. Tetapi dengan bentuknya yang compact diperlukan suatu isolasi yang dapat dihandalakan, bekerja cepat ketika terjadi gangguan, atau dapat memutuskan segitiga api ketika terjadi gangguan seperti spark.Menurut penelitian CIGRE Partial dischargemenjadi salah satu penyebab kegagalan isolasi pada GIS. Untuk itu diperlukan pemantauan terhadap Partial discharge di dalam GIS. Pengukuran kualitas GIS Paiton sejak 2010 sampai 2015 menunjukan bahwa Partial discharge sebesar 1 mV/ pC pada unit A menyebabkan penurunan kemurnian gas SF6 sebesar 0.89% per tahun dan menaikan titik embun sebesar 5.80C per tahun. Pada unit B menyebabkan penurunan kemurnian gas SF6 sebesar 0.26% per tahun dan menaikkan titik embun sebesar 9.570C per tahun. Karena itu perlu terjadi pergantian isolasi gas pada unit A setiap 3 tahun sekali dan pada unit B setiap 5 tahun sekali.

ABSTRACT
Gas Insulated Switchgear (GIS) have been widely used in the power system. GIS is used to replace conventional substation has many shortcomings. GIS been reliability, easy maintenance, and its small size of only 10% of conventional substation. But with a compact shape required an isolation that can work quickly when there is disruption, or it can decide when the fire triangle spark interference occurs. According to research CIGRE,partial discharge to be one cause insulation failure in GIS. It is necessary for the monitoring of the partial discharge in GIS. Paiton GIS quality measurements from 2010 to 2015 shows that the partial discharge of 1 mV / pC at unit 1 causes a decrease in SF6 gas purity of 0.89% per year and raise the dew point of 5.80C per year. On unit 2 caused a decrease in SF6 gas purity of 0.26% per year and raise the dew point of 9.570C per year. Because of that, it is necessary to replace the gas isolation of unit A every 3 years and the unit B every 5 years.

 File Digital: 1

Shelf
 S62047-Josan Putra.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S62047
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2016
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xii, 56 pages ; 28 cm.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S62047 14-20-152501888 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20421648
Cover