Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 107 dokumen yang sesuai dengan query
cover
Alamzuar Nurdin
Abstrak :
Aliran dua fase adalah bagian dari aliran multi fase yang dibedakan berdasarkan pada aliran fasenya (likuid - gas; solid - likuid; gas - solid), arah aliran dan posisi pipa (vertikal, horizontal dan miring). Penelitian eksperimen disini adalah untuk mendapatkan pola aliran konveksi paksa pada pipa horizontal khusus aliran dua fase yang berasal dari satu komponen. Berdasarkan daya heater yang bervariasi (342 watt sampai dengan 2070 watt) dan kapasitas aliran yang bervariasi 30 1/jam dan 60 1/jam, didih nukleat mulai terjadi pada laju aliran 30 1/jam dengan daya heater 2070 watt. Dari pengamatan pada pipa transparan dapat dilihat adanya pola aliran tertentu, yaitu aliran peralihan berupa kantung gas dan aliran sumbat likuid. Dari analisa perhitungan kualitas uap (xi) yang tercapai adalah 0,086; 0,102; 0,11; 0,116 , sedangkan fraksi hampa (a) yang tercapai adalah 0,879; 0,885; 0,888; 0,889. Dengan menggunakan diagram Taitle dan Dukler dapat dibuktikan aliran adalah aliran kantung gas dan aliran sumbat likuid. ...... Two-phase flow is a part of multi-phase flow that is distinguished according to its flow phases (liquid-gas, solid-liquid and gas-solid), flow directions (concurrent and countercurrent) and pipe positions (vertical, horizontal or inclined). The objectives of this research were to obtain the configuration of the internal forced convection flow in horizontal pipe particularly two-phase flow from one component. The experiment was conducted at variable heater power (342 Watt until 2070 Watt) and the variable capacity of water flow were 30 l/hr and 60 l/hr. Boiling happened at flow rate of 30 l/hr and heater power was 2070 Watt. The research was conducted by using transparent pipe and could be seen a certain pattern flow were intermittent flow like plug flow and slug flow. By calculation analysis the result showed that the quality of gas mass flow (x1) were 0.086;0.102;0.11;0.116. The void fraction (a) were 0.879 ; 0.885 ; 0,888 ; 0.889. By using Taitel and Dukler diagram could be proved that the flow were plug flow and slug flow.
Depok: Fakultas Teknik Universitas Indonesia, 2000
T5196
UI - Tesis Membership  Universitas Indonesia Library
cover
Abrar Riza
Abstrak :
Dalam tesis ini dilakukan penelitian alat untai uji aliran dua fase (kasus batas parameter aliran monofase) untuk melihat kemampuan alat dalam melakukan proses perpindahan panas, faktor-faktor yang mempengaruhinya serta untuk mendapatkan kurva-kurva karakteristik. Pengujian ini dilakukan untuk mencoba kemampuan sistem pada alat ini, seperti kemampuan pompa, kemampuan heater 1 dan heater 2 yang masing-masing diuji kemudian dilihat berapa lama dibutuhkan waktu untuk mencapai kondisi stedi dan temperatur maksimum yang dapat dicapai pada keadaan tanpa sirkulasi fluida kerja. Selanjutnya dilihat kinerja sistem dengan mengatur debit fluida kerja dan mengatur tegangan atau daya listrik yang diberikan untuk heater.Disini dilihat berapa banyak pengaruh temperatur fluida kerja dinaikkan oleh alat yang dapat dilihat dan temperatur saluran masuk terhadap temperatur saluran keluar dari pipa pengujian. Dengan dilakukan penelitian ini dapat dilihat kemampuan perpindahan panas alat atau kemampuan penyerapan kalor oleh fluida kerja yaitu sekitar 25 ski 55 % dari fluks kalor yang diberikan heater, dimana harganya dipengaruhi oleh tegangan atau daya listrik yang diberikan oleh heater disamping laju aliran massanya. Nilai Nu dan h dipengaruhi oleh perbedaan tegangan atau daya listrik yang diberikan pada heater meskipun dalam kondisi laju aliran massa tetap. Kurva-kurva karakteristik serta korelasi h-Re dan Nu-Re juga dibahas dalam tesis ini.
This study investigate two phase flow experimental set-up (a case of mono phase flow limit) to show the performance of the equipment for heat transfer process, the influencing factor and the curve's characteristic. The experiment was conducted in order to see the capacity of the system in the cycle such as pump capacity, performance of the heater l and the heater 2, each of which was carried out and observed to find the duration to achieve the steady state condition with and without circulating the working fluid. The performance of the system was then observed by controlling the mass flow rate of working fluid and the voltage or electric power of the heater. This research reveals the transformation capacity of the equipment or heat flux absorbing capacity is about 25 to 55% of the heat flux given by the heater, whose value was influenced by the voltage or electric power applied to the heater besides its mass flow rate. The values of Nu and h are influenced by the heat supplied in addition to the constants mass flow rate. The characteristics of the curve as well as the correlation of h-Re and Nu-Re were also analyzed in this study.
Depok: Fakultas Teknik Universitas Indonesia, 1999
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Budi Utomo
Abstrak :
Nanofluida adalah jenis fluida baru, yaitu pencampuran partikel nano dalam fluida dasar (air), dimana partikel nano ini tetap tersuspensi secara permanen dalam fluida dasarnya, akibat adanya gerakan Brownian dari partikel nano tersebut. Dalam menentukan karakteristik operasi dari alat penukar kalor dengan metoda grafik, penelitian dilakukan pada air-air dan menjelaskan hubungan kalor antara yang hilang dengan parameter - parameter lainnya, seperti aliran fluida dan sifat-sifat termal pada alat double pipe heat exchanger. Penelitian dilakukan pada nanofluida A1203, hasilnya menunjukkan peningkatan dalam koefisien perpindahan kalor konveksi dibandingkan dengan fluida dasarnya 2.1%-11.86% untuk konsentrasi partikel nano 1% dan 4.2% 17.38% untuk konsentrasi partikel nano 4%. Rasio peningkatan koefisien perpindahan kalor konveksi dari nanofluida juga meningkat, seiring dengan peningkatan temperatur (40°C - 60°C).
Nano fluids are a new kind of fluids; they are dispersion if nano particles in liquids that are permanently suspended by Brownian motion. To assign operation characteristic from heat exchanger with graphic method, Research shown at water to water assignment shows correlation between heat loss and other parameters, such as: fluids flow and thermal characteristic in double pipe heat exchanger. Research shown at nano fluid A1203 water 1% and 4%, the result shown the enhancement of heat transfer convective coefficient compared to the base fluids 2.1%- 11.86% for 1% particles concentration and 4.2% -17.38% for 4% particles concentration. The rate of increase of enhancement shows adrainatic increase with elevated temperature (40°C-60°C).
Depok: Fakultas Teknik Universitas Indonesia, 2003
T14739
UI - Tesis Membership  Universitas Indonesia Library
cover
Harianto Oetojo
Depok: Fakultas Teknik Universitas Indonesia, 1990
S35344
UI - Skripsi Membership  Universitas Indonesia Library
cover
Asyari
Depok: Fakultas Teknik Universitas Indonesia, 1990
S35502
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhamad Syafrudin
Depok: Fakultas Teknik Universitas Indonesia, 1992
S36094
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Ma`ruf
Depok: Fakultas Teknik Universitas Indonesia, 1993
S36710
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rudi Kurniawan
Depok: Fakultas Teknik Universitas Indonesia, 1994
S36359
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rahmad Novirsal
Depok: Fakultas Teknik Universitas Indonesia, 1994
S35944
UI - Skripsi Membership  Universitas Indonesia Library
cover
Andi Bakhtiar
Depok: Fakultas Teknik Universitas Indonesia, 1994
S36328
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>