Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 4 dokumen yang sesuai dengan query
cover
Heru Purnomo
"Physical behavior of models can be measured in the laboratory, which, in turn are often used to assess the behavior of more complicated structures. Mechanical responses present physical behavior of a structure. By using three different transducer, one can measure acceleration, velocity and displacements directly. Determination of velocity and displacements from acceleration data is preferable from point of view economics; but on the other hand this procedure, at present, is still causing problem. This study shows that displacements and velocity can be calculated from its acceleration which is obtained by using one transducer.
The acceleration data are obtained from a cantilever steel plate which is subjected to a transient force at a discrete location on its surface or an initial deflection on its tip. An acquisition program was first designed before starting the experimental program. By means of a piezoelectric accelerometer, a conditioning amplifier and a digital oscilloscope, acceleration data are captured and then transferred to a personal computer.
The transformation of these two responses, displacements and velocity from the acceleration data are performed in two domains, time domain and frequency domain. Two integration techniques, Newton-Cotes formula and Simpson's rule were used for the calculation in the time domain. For both techniques, adjustment of basis line is performed by End Zero Time Technique Modified. Programmation has been done for both types of domain analysis.
The Simpson's rule gives sufficient results and Newton-Cotes formulation gives good results only for moderate values of Cotes coefficient. High values of the coefficient give unrealistic calculated velocity and displacements. Drifting character are present on the displacements calculated by both methods.
In the frequency domain, the velocity and displacements are obtained from acceleration data by means of Fast Fourier Transform and its Inverse Fourier Transform. This method give satisfactory results only for the calculation of velocity. The displacements obtained show also drifting character. Nevertheless, realistic forms of this displacements are moderately accepted.
Results comparison of the two methods, both in time domain and frequency domain, show that none of the method is better than another. Analysis in frequency domain give more accurate results, but this method is not definitely a principal method for the solution of this type of problems. The two methods shall be used for the calculation of velocity and displacements. This procedure can verify one result to another to avoid wrong interpretation of transformed responses."
Depok: Fakultas Teknik Universitas Indonesia, 1996
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
M. Awwaluddin
"Analisis kekuatan struktur dan nilai ergonomi sistem mekanik perangkat diagnosis fungsi ginjal dan thyroid terpadu, dilakukan untuk memastikan keamanan perangkat, mengetahui kendala atau keluhan pasien maupun operator, dan sebagai bagian dari upaya penyempurnaan perangkat tersebut. Analisis ini dilakukan dengan menghitung kekuatan rangka lengan, rangka utama kursi, rangka sandaran pasien, serta menganalisis data antropometri statis manusia Indonesia untuk menentukan ukuran kursi pasien dan penyetelan ukuran kursi. Data antopometri dinamis manusia Indonesia kita gunakan untuk menentukan tata letak dan jangkauan gerakan operator serta tenaga medis pada saat mengoperasikan perangkat diagnosis fungsi ginjal dan thyroid terpadu. Hasil analisis menunjukkan struktur tersebut aman dikarenakan tegangan aktual yang terjadi masih dibawah nilai batasnya sebesar 248 MPa. Perangkat tersebut juga mempunyai nilai ergonomi yang baik sehingga dapat diproduksi secara masal.

An analysis of structure strength and ergonomic value of mechanical
systems of integrated kidney and thyroid diagnosis device, has been performed to ensure the security of the device, understand the patient's as well as operator problem and complaints, as part of the efforts to improve the performance of these devices. The analysis is done by calculating the strength of arm, the main frame chairs, and frame backrest patients, as well as analyzing the static anthropometry data for Indonesian man to determine the size of the dental chair and adjusting the size of the seat. We also use the dynamic anthropometry data for Indonesian man to determine the layout and range of movement of the operator while operating the integrated device. The analysis showed that the structure is safe because the actual stress that occurs is still below the limit value of 248 MPa. The device also has good ergonomic value so that it can be bulk produced.
"
Jakarta: Pusat Rekayasa Fasilitas Nuklir (PRFN)-BATAN, 2016
621 JPN 10:2 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Jakarta: Gramedia, 1992
378.155 DAS (1)
Buku Teks  Universitas Indonesia Library
cover