"Hydrocarbon can be used as alternative refrigerant because it has small GWP and zero ODP. This
research intends to compare these Indonesian Hydrocarbon Refrigerants. fine experiment was held al
Air Conditioning Test Facility, BTMP - BPPTZ The experiment was running based on the following
conditions: compressor running or 2980 rpm, inlet evaporator for evaporator was varied from -2°C until
6°C and outlet temperature of condenser was set at 39°C Test analysis shows that hydrocarbon
performance is almost some as CFC-I2 even better than RI2. As conclusion hydrocarbon can be used
as alternative for CFC-12.
"
Jurnal Teknologi, 20 (4) Desember 2006 : 241-251 , 2006
JUTE-20-4-Des2006-241
Artikel Jurnal Universitas Indonesia Library
Rachmah Rizky
"
ABSTRAKNaskah ini bertujuan untuk mengetahui performa sistem chiller pada pengoperasian ruang auditorium di Gallery Art Centre, Universitas Indonesia, sekaligus memverifikasi desain sistem. Instalasi sistem chiller berbasis refrigeran alami merupakan yang pertama untuk institusi perguruan tinggi di Indonesia yang juga merupakan bagian dari usaha green campus movement. Sistem pendinginan dengan memanfaatkan jenis refrigeran yang memiliki nilai ODP dan GWP rendah saat ini menarik perhatian dalam hal riset dan implementasi untuk menggantikan penggunan refrigeran R22. Dari hasil pengujian didapatkan COP rata-rata maksimum 4.27 pada kondisi pembebanan kosong, dan 5.25 saat pembebanan parsial. Kapasitas pendinginan maksimum kondisi tanpa pembebanan dan pembebanan parsial adalah masing-masing 125.93 kW dan 148.39kW, dengan konsumsi daya 30.06 kW and 30.12 kW.
ABSTRACT<>br>
The purpose of this paper is to examine energy efficiency through the study of performance in vapour compression cycle for auditorium in University of Indonesia using natural refrigerant R290. The installation of the chiller system which is the first in Indonesia within academic institution is particularly relevant in light of the gaining interest and research regarding the implementation of refrigeration system utilizing relatively low ODP and GWP refrigerant as alternative to replace the refrigerant R22. It is found that the maximum average COP is 4.27 at free load and 5.25 at partial load. The cooling capacity are 125.93 kW with energy consumption of 30.06 kW during free load and 148.39 kW with energy consumption of 30.12 kW at partial load, respectively."
Depok: Fakultas Teknik Universitas Indonesia, 2018