Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Lukluk Khairiyati
Abstrak :
Pada tesis ini dilakukan pengukuran dan analisis ketidakpastian resistor standar 1 Ω tipe Fluke 742A. Analisa ketidakpastian meliputi ketidakpastian parameter ukur rasio Jembatan Komparator Arus Searah dan ketidakstabilan suhu resistor yang diuji. Pengukuran kesalahan parameter ukur rasio jembatan DCC tipe Guildline 6675A dilakukan menggunakan metode generik dan metode basis resistansi yang merupakan metode pengujian yang dikembangkan. Pengukuran koefisien suhu resistor standar 1 Ω uji dilakukan pada rentang suhu 18 oC hingga 28 oC. Pengukuran resistor standar ini dilakukan dengan menurunkan nilai resistor standar 1 Ω tipe Thomas yang tertelusur pada sistem QHR di Puslit KIM-LIPI kepada resistor standar termaksud. Diperoleh hasil pengukuran kesalahan parameter ukur rasio jembatan DCC dengan metode generik untuk rasio 0,1:1 hingga 10:1 adalah (0,14 ± 1,68) ppm, sedangkan dengan metode basis resistansi untuk rasio kombinasi hubung paralel atau seri-paralel dan untuk rasio hubung seri masing-masing sebenar (1,19 ± 1,81) ppm dan (-0,44 ± 0,15) ppm. Nilai koefisien suhu resistor standar akibat perubahan suhu didapat a=1,66 ppm/ oC dan b = -0,031 ppm/ oC2. Menggunakan nilai-nilai tersebut ketidakpastian resistor standar 1 Ω tipe fluke 742A sebesar 1,00002048 Ω dengan ketidakpastian sebesar 0,000000146 Ω. ...... Measurement and uncertainty analysis of standard resistor (Fluke-742A) 1 Ω type is reported. The uncertainty analysis consists of the uncertainty of Direct Current Comparator Bridge (DCC Bridge) and temperature instability of the resistor under test. The error measurement of the ratio measure parameter of 6675A DCC Bridge-Guildline was done using generic method and base resistor method which is a developed measuring method. Measurements of coefficient temperature of standard resistor under test it for temperature range of 18 oC to 28 oC. The measurement of the standard resistor was done using DCC Bridge by disseminating the standard resistor value of 1 Ω Thomas type that is traceable to QHR Puslit KIM-LIPI to the standard resistor referred. The error measurement value of the ratio measure parameter using generic method at the ratio of 0.1:1 to 10:1 was , whereas, the error measurement result using base resistor method at the ratio of parallel or series-parallel circuit combination and the ratio of series circuit were and respectively. The coefficient temperature values of standard resistor ​​regarding temperature changes ware a=1,66 ppm/ oC and b = -0,031 ppm/ oC2. Based on the measurement, the value of standard resistor of 1 Ω Fluke 742A type was 1,00002048 Ω with the uncertainty of 0,000000146 Ω.
Depok: Fakultas Teknik Universitas Indonesia, 2014
T41569
UI - Tesis Membership  Universitas Indonesia Library
cover
Erfan Syahputra
Abstrak :
ABSTRAK Disebabkan lokasinya di iklim tropis, Indonesia memiliki faktor kondisi cuaca yang berbeda dari iklim subtropis sehingga memengaruhi bebarapa indikator evaluasi kinerja sistem fotovoltaik. Salah satu indikator tersebut ialah performance ratio yang dipengaruhi faktor suhu. NREL mengajukan metode perhitungan Weather-Corrected Performance Ratio untuk mengoreksi faktor cuaca suhu dalam menghitung performance ratio pada sistem fotovoltaik. Tetapi, implementasi penggunaan metode ini pada kondisi operasi sistem fotovoltaik pada lingkungan yang sebenarnya, terlebih di daerah tropis belum mendapat perhatian khusus. Selain itu koefisien perubahan daya modul terhadap suhu pada keadaan uji standar STC , yang digunakan pada metode perhitungannya mungkin berbeda jika pada kondisi yang sebenarnya. Penelitian ini dilakukan untuk mengetahui efek implementasi metode weather-corrected performance ratio dan mengetahui karakteristik nilai koefisien perubahan daya modul terhadap suhu sebagai faktor koreksi dalam metode weather-corrected performance ratio, pada kondisi yang sebenarnya di daerah tropis. Melalui pengolahan data sistem fotovoltaik dari data logger didapat bahwa nilai range dari metode weather-corrected performance ratio lebih besar dari metode konvensional, dengan kenaikan maksimum 2,43 . Selain itu diketahui bahwa suhu rata-rata iklim tropis yang lebih tinggi dari subtropis membuat persentase penurunan daya terhadap kenaikan suhu di iklim tropis lebih tinggi dari iklim subtropis.
ABSTRACT Indonesia has different weather factors than the subtropical climate that influences the performance indicators of photovoltaic systems. One of them is performance ratio that affected by temperature factors. NREL propose calculation method of Weather Corrected Performance Ratio for correcting factors temperature in calculation performance ratio of photovoltaic systems. However, the implementation of this method on real operating conditions of photovoltaic systems, especially in the tropics has not received special attention. In addition, temperature coefficient of power photovoltaic in Standard Test Condition , used in the calculation method may be different in real operating condition. This study was conducted to determine the effects of weather corrected performance ratio method and to know characteristic of temperature coefficient of power photovoltaic as factors in of weather corrected performance ratio method, in real operating condition, especially in tropics. Through analysis photovoltaic system data from the data logger it is found that the range values of weather corrected performance ratio are greater than conventional methods, with a maximum increase of 2.43 . Moreover it is found that because average temperature of tropical climate is higher than subtropical climate, it makes the percentage of power decrease to rise in temperature in tropical climate is higher than subtropical climate.
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Farrel Mahardhika Fajar
Abstrak :
Kelahiran prematur merupakan masalah berkepanjangan yang berhubungan dengan risiko morbiditas dan mortalitas bayi. Sistem inkubator dikemukakan untuk meminimalkan risiko kelahiran prematur. Salah satu sistem otomasi yang digunakan pada inkubator adalah regulasi panas dan kelembaban. Regulasi panas dan kelembaban umumnya dikendalikan menggunakan sistem kendali feedback seperti PID dan fuzzy-logic PID. Material PTC adalah material yang biasa digunakan sebagai pemanas ruangan. Sistem kendali digunakan untuk mengendalikan pemanas PTC agar mencapai suhu yang diinginkan. Pada penelitian ini dilakukan empat jenis eksperimen untuk mengevaluasi performa PTC sebagai pemanas inkubator dengan PID dan fuzzy logic-PID sebagai sistem kendali. Pertama, dilakukan uji karakteristik hambatan PTC terhadap suhu. Selanjutnya, PTC dihubungkan dengan kipas dan digunakan sebagai pemanas inkubator untuk diuji performa material sebagai pemanas. Eksperimen ini meliputi uji step response untuk mengetahui parameter yang diperlukan untuk tuning PID. Parameter ini kemudian digunakan pada kendali PID. Ditambah itu, diberikan implementasi fuzzy-logic pada PID untuk mengevaluasi perbandingan performa pengendali dengan performa inkubator yang sudah ada. Hasil penelitian yang dilakukan menunjukkan bahwa pemanas PTC dapat memanaskan udara pada inkubator dan dapat dikendalikan menggunakan sistem kendali PID dan fuzzy-logic PID. Meski performa lebih buruk dibandingkan sebagian besar inkubator yang sudah ada, konsumsi daya PTC yang hanya membutuhkan 120 Watt bersifat lebih hemat dibandingkan inkubator eksisting yang menghabiskan daya 350 – 400 Watt. ......Premature birth is an everlasting problem that relates to the risk of morbidity and mortality of prematurely-birth infants. Incubator system was invented to minimize the risk. One of the automation systems that are used in incubator is heat and humidity regulation. This particular regulation system commonly uses feedback control system such as PID and fuzzy-logic PID. PTC material is the material commonly used as a room heater. In order to meet the desired temperature, control system is implemented to the PTC. This research evaluates the performance of PTC as incubator heater with PID and fuzzy logic-PID as the control system of choice. First, characteristic test is performed at the material to evaluate its heating performance. This test costists of step response test to determine parameters required to perform PID tuning. The obtained parameter is then calculated to determine the tuned PID parameter gains. After that, fuzzy logic is implemented to the system which controls those parameters based on the measured error and change of error. The result of both experiments are compared to existing incubators used in publications. The result of this comparison shows that PTC is capable of warming incubator to desired temperature and can be controlled with PID and fuzzy-logic PID. While the performance is inferior to majority of existing incubators, this tradeoff of more efficient power (120 Watt versus 350 – 400 Watt) can be considered as an alternative.
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library