Abstrak :
ABSTRAK
Penyetelan ulang pengendali proporsional-integral dilakukan pada proses produksi formaldehida di PT X. Penyetelan ulang dilakukan untuk meningkatkan kinerja controller, karena penyetelan pengendali PI pada pabrik seringkali masih menggunakan metode ziegler-nichols close-loop yang kurang optimal. Model proses akan diestimasi dengan first order plus dead time model (FOPDT), dan kemudian parameter pengendali disetel ulang menggunakan Ziegler-Nichols (PRC), Wahid-Rudi-Victor (WRV), Cohen-Coon, autotuning, dan fine tuning. Kinerja pengendali diuji menggunakan set point (SP) tracking dan disturbance rejection. Integral of square error (ISE) akan digunakan sebagai indikator kinerja. Ada tiga pengendali yang diuji, yaitu, pengendali laju alir steam (FIC-102), pengendali temperatur udara (TIC-101), dan pengendali level tangki (LIC-102). Metode fine tuning memberikan kinerja pengendali yang paling baik untuk FIC-102 dan TIC-101, sedangkan metode autotuning memberikan kinerja pengendali yang lebih baik untuk LIC-102 dibandingkan dengan setelan di lapangan. Peningkatan kinerja untuk set point (SP) tracking adalah 81,59% (FIC-102), 94,11% (TIC-101), dan 85,61% (LIC-102). Sedangkan peningkatan kinerja untuk disturbance rejection adalah 95,5% (FIC-102), 94,53% (TIC-101), dan 93,16% (LIC-102). Pengujian penurunan kapasitas produksi sebesar 12,5% juga dilakukan, dan didapatkan bahwa controller masih mampu mencapai SP. Dengan demikian, penyetelan ulang pengendali PI berfungsi dengan baik.
ABSTRACT
A proportional-integral controller retuning is performed on formaldehyde production process at PT X. Retuning is carried out to improve the control performance, because PI controller in the factory often still uses ziegler-nichols close-loop tuning method which is not optimal. The process model is estimated by a first order plus dead time model (FOPDT), and then the controller parameters is tuned using the Ziegler-Nichols (PRC), Wahid-Rudi-Victor (WRV), Cohen-Coon, autotuning, and fine tuning. The control performance is tested using set point (SP) tracking and disturbance rejection with integral of square error (ISE) as performance indicator. There are three controllers that are tested, i.e., the steam flow controller (FIC-102), air temperature controller (TIC-101), and tank level controller (LIC-102). Fine tuning method give the better control performance for FIC - 102 and TIC-101, while autotuning method gives the better control performance for LIC-102 compared to the previous settings in the field. Performance improvement for set point (SP) tracking are 81.59% (FIC-102), 94.11% (TIC-101), and 85.61% ( LIC-102). While performance improvement for the disturbance rejection are 95.5% (FIC-102), 94.53% (TIC-101), 93.16% ( LIC-102). A test using reduction in production capacity of 12.5% was also carried out, and it was found that the controller was still able to reach SP. Thus, retuning PI controllers work well.
2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mahdi
Abstrak :
ABSTRACT
Penyetelan ulang pengendali proportional integral dilakukan pada pabrik penghilangan CO2 pengolahan gas alam lapangan Subang. Penyetelan ulang ini dilakukan untuk meningkatkan kinerja pengendali pada pabrik tersebut. Pengendali pada pabrik yang diteliti pada penelitian ini adalah pengendali tekanan gas umpan PIC 1101, pengendali laju alir air FIC 1102, dan pengendali laju alir sirkulasi amina FIC 1103. Metode penyetelan ulang pengendali yang diusulkan adalah metode Ziegler-Nichols PRC, Wahid-Rudi-Victor WRV, Cohen-coon, setelan hasil autotuner pada simulator, dan fine tuning. Dari hasil pengujian terhadap setiap metode penyetelan yang diusulkan, didapatkan hasil setelan yang memberikan hasil paling baik untuk setiap pengendali, yaitu setelan fine tuning. Penyetelan menggunakan fine tuning berhasil meningkatkan kinerja pengendali PIC 1101 sebesar 77,42, FIC 1102 sebesar 90.59 dan FIC 1103 sebesar 13,06 untuk penurunan nilai setpoint SP sebesar 5. Sementara untuk kemampuan pengendali mengatasi gangguan didapatkan peningkatan kinerja pengendali PIC ndash; 1101 sebesar 86,04, FIC 1102 sebesar 90,8 dan FIC 1103 sebesar 24,8.
ABSTRACT
A proportional ndash integral controller retuning is performed on CO2 removal plant in natural gas processing Subang field. Retuning is performed to increase controller performance on the plant. Retuning will be performed on feed gas pressure controller PIC ndash 1101, make up water flow controller FIC 1102 , and amine circulation flow controller FIC 1103 on the plant. Retuning methods used are Ziegler ndash Nichols PRC, Wahid Rudi Victor WRV, Cohen coon, tuning from simulator autotuner, and fine tuning method. Result of this research shows that retuning that gives the highest improvement for the controllers is tuning with fine tuning method for every controller. Retuning with fine tuning can give 77,42 improvement for PIC ndash 1101, 90,59 improvement for FIC 1102, and 13,06 improvement for FIC ndash 1103 for 5 setpoint SP reduction. While for controller capability to handle disturbance, fine tuning can give 86,04 improvement for PIC ndash 1101, 90,8 improvement for FIC ndash 1102, and 24,8 improvement for FIC 1103.
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ivan Christopher
Abstrak :
Model Predictive Control (MPC)-Single Input Single Output (SISO) digunakan untuk mengoptimalisasi parameter pengendalian pada penghilangan CO2 di lapangan Subang. MPC-SISO digunakan untuk mengendalikan laju aliran amina, laju aliran makeup water, dan tekanan gas umpan untuk mempertahankan konsentrasi CO2 pada keluaran sweet gas. Model empiris dibuat untuk diterapkan di MPC controller berdasarkan kurva reaksi proses (PRC) dengan menggunakan pendekatan first order plus dead time (FOPDT) berbasis SISO (Single Input-Single Output). Namun, bila terdapat disturbance pada feed gas, seperti perubahan laju air dan konsentrasi CO2, maka dibutuhkan penyesuaian kembali berupa re-tuning agar produk sweet gas yang dihasilkan tetap terjaga kualitasnya. Metode Ziegler-Nichols, Tyreus-Luyben dengan Bode Diagram, serta fine-tuning digunakan dalam mengamati respons pengendali PIC-1101, FIC-1102, dan FIC-1103 terhadap adannya disturbance. Dengan simulasi dinamik yang dilakukan, maka didapatkan nilai FOPDT berbasis SISO untuk tiap pengendali dengan metode fine-tuning yang terbaik untuk penyetelan SP (PIC-1101 ISE = 721300 dan IAE = 2764, FIC-1102 ISE = 113.1 dan IAE = 701, dan FIC-1103 ISE = 2262000 dan IAE = 19430). Untuk menangani gangguan berupa laju alir dan konsentrasi, metode Ziegler-Nichols merupakan metode yang terbaik untuk pengendali PIC-1101 (ISE = 2.409 dan IAE = 5.723 untuk laju alir dan ISE = 0 dan IAE = 0 untuk konsentrasi CO2) dan FIC-1102 (ISE = 0.00001392 dan IAE = 0.1663 untuk laju alir dan ISE = 0 dan IAE = 0 untuk konsentrasi CO2) serta fine-tuning untuk FIC-1103 (ISE = 2.382 dan IAE = 63.41 untuk laju alir dan ISE = 8.693e+04 dan IAE = 8.361e+03 untuk konsentrasi CO2). ......Model Predictive Control (MPC) - Single Input Single Output (SISO) is used to optimize the control parameters for CO2 removal in the Subang field. MPC-SISO is used to control amine flow rate, makeup water flow rate, and feed gas pressure to maintain CO2 concentrations in sweet gas output. Empirical models are made to be applied in the MPC controller based on the process reaction curve (PRC) using the first order plus dead time (FOPDT) approach based on SISO (Single Input-Single Output). However, if there are any disturbances in the gas feed, such as flow rate and CO2 concentration, then re-tuning is necessary so that the sweet gas product is maintained in its best quality. The Ziegler-Nichols method, Tyreus-Luyben method with Bode Diagrams, and Fine-Tuning method are used in observing the response of the PIC-1101, FIC-1102, and FIC-1103 controllers to disturbance. With the dynamic simulation carried out, the SISO-based FOPDT values ​​for each controller are obtained with the best fine-tuning method for SP settings (PIC-1101 ISE = 721300 and IAE = 2764, FIC-1102 ISE = 113.1 and IAE = 701, and FIC-1103 ISE = 2262000 and IAE = 19430). To deal with disturbances of flow rate and CO2 concentration, the Ziegler-Nichols method is the best method for controlling PIC-1101 (ISE = 2.409 and IAE = 5.723 for flow rates and ISE = 0 and IAE = 0 for CO2 concentration) and FIC-1102 (ISE = 0.00001392 and IAE = 0.1663 for flow rate and ISE = 0 and IAE = 0 for CO2 concentration) and fine-tuning for FIC-1103 (ISE = 2.382 and IAE = 63.41 for flow rate and ISE = 8.693e + 04 and IAE = 8.361e + 03 for CO2 concentration).
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yogi Priasetyono
Abstrak :
ABSTRAK
Pengasaman air laut di alam adalah salah satu fenomena akibat adanya perubahan iklim. Kebanyakan eksperimen pengasaman air laut dilakukan di laboratorium dengan sistem yang cukup sederhana. Pada penelitian ini, air laut di dalam akuarium akan di berikan gas CO2 melalui katup jarum yang dikendalikan oleh stepper motor menggunakan kendali sistem Proportional-Integral-Derivative (PID). Akuarium akan dilengkapi pengaduk untuk mempercepat homogenitas sistem serta sensor pH untuk memantau perubahan pH pada sistem akuarium. Arduino sebagai sistem kontrol akan bertugas untuk menggendalikan stepper motor, menjaga pH pada sistem akuarium sesuai set point serta membaca dan merekam perubahan yang terjadi pada sistem akuarium. Hasil penelitian ini menunjukkan sistem mampu meraih setpoint dan menjaga nilai pH sebesar 6,9 ± 0,2. Dari hasil penelitian ini, sistem sangat cocok dilakukan untuk penelitian yang memiliki waktu yang panjang.
ABSTRACT
Ocean acidification is one of the phenomena caused by climate change in the world. Most Ocean Acidification (OA) experiment is carried out in a laboratory by creating a simple system. In this research, the sea water in tank given CO2 gas which is regulated using a needle vale that driven by stepper motors using Proportional-Integral-Derivative (PID) system. This tank is equipped with stirrer to accelerate the homogeneous system and pH sensor to monitor pH changes. Arduino as a system kontrol is tasked to regulate stepper motors, keeping the pH value as appropriate set point and reading while recording the changes occurring on the tank. The results of this research show that the system can reach a set point and maintain it with a pH range of 6,9 ± 0.2. Of the research results can also be concluded this system is very suitable for long-term research.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Muhammad Nur Tsani Rizka
Abstrak :
Pada tahun 2015, Indonesia diproyeksikan mengalami defisit bahan bakar minyak sebesar 562.000 barrel/ hari. Untuk menutupi defisit tersebut diperlukan upaya luar biasa berupa pembangunan terminal transit bahan bakar minyak impor atau pembangunan kilang baru dan modifikasi kilang eksisting dengan kapasitas pengolahan sebesar minimal 300.000 barrel/ hari guna menjaga ketahanan energi nasional. Disain kilang yang ada harus dipasang dengan sistem pengendalian untuk menghindari gangguan pada proses yang berdampak pada keefektifan dan kestabilan operasi pabrik. Pada awalnya minyak bumi akan diproses pada bagian Crude Distillation Unit (CDU) untuk mendapatkan produk straight run. Unit ini sangat menentukan rate produk sehingga perlu diterapakan konfigurasi sistem pengendalian yang optimum. Jenis pengendali yang akan diterapkan pada penelitian ini adalah pengendali PI (Proportional - Integral) karena dapat menangani hampir setiap situasi pengendalian proses di dalam skala industri. Telah banyak rancangan kilang dengan model konfigurasi tertentu dan metode pengendali tertentu, misalnya kilang dengan dominasi produk bensin dengan pengendali PID dan kilang dengan dominasi produk kerosene dengan pengendali PI. Pengendalian proses kolom distilasi ini dilakukan dengan mensimulasikan secara dinamik pada perangkat lunak Aspen Hysys v.8. Penyetelan pengendali dilakukan untuk mendapatkan parameter kinerja alat kendali yang optimum yaitu dihitung berdasarkan metode Ziegler - Nichols, Lopez dan fine tunning. Sebagai hasilnya, pada pengendali laju alir diesel dan light naphta, pengendali tekanan pada reboiler, dan pengendali temperatur feed masukan kolom distilasi digunakan penyetelan Lopez. Sedangkan untuk pengendali laju alir AGO (atmospheric gas oil) dan level kondenser digunakan penyetelan fine tuning.
By 2015, Indonesia is projected in deficit of fuel oil by 562.000 barrels/ day. To cover that deficit, Indonesia requires a tremendous efforts such as the construction of a transit terminal which is imported fossil fuels or the construction of new refineries and modification of the existing refinery with a processing capacity of at least 300.000 barrels/ day in order to maintain national energy security. The design of the existing refinery has to be fitted with a control system to avoid interruptions that have an impact on the effectiveness and stability of plant operations. At first, crude oil will be processed at the Crude Distillation Unit (CDU) to obtain straight run products. This unit will determine the rate of product that needs to be applied an optimum configuration of system control. PI controller (Proportional - Integral) will be applied to the system control because it can handle almost any situation in process control in industrial scale. Have many designs refineries with a particular configuration model and specific control methods, such as a refinery with a petrol product dominance with a PID controllers and refineries with kerosene product dominance with a PI controller. The distillation column of process control is done by simulating the plant dynamically in Aspen Hysys v.8 software. Adjustments made to obtain the optimum performance parameters of control device that is calculated based on Ziegler - Nichols, Lopez and fine tunning methods. As a result, the diesel and light naphtha flowrate controllers, reboiler pressure controller, and input feeds temperature of a distillation column controller used Lopez adjustment. As for the AGO (atmospheric gas oil) flowrate controller and the level of conndenser controller used fine tuning adjustment.
Depok: Fakultas Teknik Universitas Indonesia, 2014
S58870
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aristia Reyhan Rafandi Betha
Abstrak :
Beragam kebutuhan industri, membuat jenis-jenis proses pada industri pengolahan menjadi beragam dengan berberapa parameter input dan output, salah satunya adalah proses thermal mixing yang menggunakan sistem multi input multi output. Thermal mixing atau continuous stirred-tank reactor mengendalikan 2 aliran dengan temperatur berbeda kedalam tanki pencampur sehingga mendapat temperatur dan ketinggian tangki sesuai yang diinginkan. pada penelitian ini telah dirancang sistem pengendali berbasis logika fuzzy pada pengendalian temperatur dan level. Penelitian ini sistem logika fuzzy menngunakan 2 input dan 1 output unutk masing-masing parameter pengendalian. 2 input fuzzy set menggunakan nilai error dan change of error. Setiap fuzzy set menngunakan 7 membership function yaitu negative big (NB), negative medium (NM), negative small (NS), zero (Z), positive small (PS), positive medium (PM), dan positive big (PB). Sistem dapat melakukan pengendalian temperatur dan level sesuai yang diinginkan. Sistem ini menggunakan simulasi berbasis aplikasi MATLAB Simulink. Berdasarkan hasil simulasi, dapat disumpulkan bahwa pengendalian menggunakan fuzzy logic controller lebih baik dibandingkan pengendalian PID. Hasil pengendalian fuzzy memiliki rata-rata rise time dan settling time yang lebih cepat dan tidak memiliki overshoot.
A variety of industrial needs, making the types of processes in the processing industry to be diverse with several input and output parameters, one of which is a thermal mixing process that uses a multi-input multi output system. Thermal mixing or continuous stirred-tank reactor controls 2 streams with different temperatures into the mixing tank so that the temperature and height of the tank are as desired. In this research a fuzzy logic based controller system has been designed for controlling temperature and level. This study uses a fuzzy logic system using 2 inputs and 1 output for each control parameter. 2 fuzzy input sets use error and change of error values. Each fuzzy set uses 7 membership functions, namely negative big (NB), negative medium (NM), negative small (NS), zero (Z), positive small (PS), positive medium (PM), and positive big (PB). The system can control the temperature and level as desired. This system uses a simulation based on the MATLAB Simulink application. Based on the simulation results, it can be concluded that the control using fuzzy logic controller is better than PID control. Fuzzy control results have a faster average rise time and settling time and do not have overshoot.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Slamet
Abstrak :
This research described about speed control of three phase AC induction motor using the space - vector algorithm and proportional integral controller with constant v/f (volt/Hz) methods based on microcontroller typ e atmega 16. To determine parameters in proportional integral controller used constant v/f method as speed controller of three phase AC introduction motor. On experiment, applied speed censor from 12 volts d.c. motor functioned as generator connected by op-amp circuit. Output voltage Op-Amp interfced to ADC microcontroller as signal feedback from actual speed of of triphase AC induction motor. Then in empiric is searched transfer function of the motor. After that, determined specification of control system performance proportional integral at triphase AC motor to determine magnitude Kp (proportional gain). Ki (Integral gain) , 0(dead time) dan t(time constants), and then is applicated to the system. Testing system is don for setpoint manevver from 480 rpm to 1080 rpm, and then from 1200 rpm to 480 rpm . Based on the motor can be controller system proportional integral for speed of triphae AC motor can be controlled to reach stable condition, In maneuver set point under specification of nominal speed performance of three phasa AC induction motor.
KEENTER
Artikel Jurnal  Universitas Indonesia Library
cover
Ardhanarendra
Abstrak :
Motor DC shunt sudah banyak digunakan di industri. Berbeda dengan motor DC umumnya, motor DC shunt memiliki karakteristik tidak linear. Ketidaklinearan motor dc shunt menjadi tantangan dalam perancangan sistem kendali kecepatan putar khususnya ketika terjadi perubahan beban. Skripsi ini membahas tentang perancangan sistem kendali kecepatan putar motor dc shunt menggunakan pengendali PI (Proportional Integral) dan I/O (Input/Output) Linearization. Kendali kecepatan putar dimaksudkan untuk mempertahankan kecepatan putar motor pada nilai referensinya meskipun terjadi perubahan beban. Perancangan kedua pengendali dilakukan menggunakan model motor DC shunt linear dan tak linear. Model DC shunt dan hasil rancangan pengendalinya disimulasikan menggunakan MATLAB SIMULINK. Dari hasil simulasi, pengendali PI dapat mempertahankan kecepatan putar motor sesuai nilai referensinya meskipun ada perubahan beban. Sedangkan pengendali I/O Linearization, selain dapat mempertahankan kecepatan putar sesuai nilai referensinya dalam kondisi perubahan beban, dapat juga mengikuti nilai referensi kecepatan putar yang baru. ...... DC shunt motors are already widely used in industry. Unlike common DC motor, DC shunt motors have highly nonlinear characteristics. Nonlinearity of shunt dc motor is a challenge in the design of speed control system, especially when the load changes. This research discusses design of speed control system for shunt dc motor using PI ( Proportional Integral ) and I / O ( Input / Output ) linearization. Speed control is intended to maintain actual motor speed to its reference value despite changes in load. The design of both controllers performed using a linear and non linear model of shunt DC motor. DC shunt model and its controllers is simulated using MATLAB SIMULINK. From the simulation results, the PI controller can maintain the rotational speed of the motor according to the reference value even though there is load change. Besides of maintaining rotational speed to its reference value in the load condition changes, I / O linearization can be used to follow rotational speed to new rotational speed reference.
Depok: Fakultas Teknik Universitas Indonesia, 2014
S54042
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rilam Alfa Firdaus
Abstrak :
Tert amyl methyl ether (TAME) adalah senyawa aditif oksigenat dari golongan eter yang dapat diproduksi dengan distilasi reaktif. Masalah utama dari penggunaan kolom distilasi reaktif adalah adanya kombinasi sistem reaksi dan pemisahan dalam satu kolom sehingga menghasilkan sistem yang sangat kompleks akibat dari interaksi setiap variabel proses yang saling mempengaruhi satu dengan yang lain. Oleh karena itu, dibutuhkan jenis pengendalian dengan kinerja yang dapat menjaga kondisi operasi tetap stabil dan mampu menangani gangguan proses dengan baik seperti Model Predictive Control (MPC). Pada penelitian ini, dilakukan simulasi pengendalian proses produksi TAME yang menggunakan kolom distilasi reaktif berskala pabrik dengan MPC dan proportional integral (PI) pada simulator HYSYS V11. Model untuk mewakili kondisi dinamis pada sistem ini didekati dengan model FOPDT. Untuk mendapatkan hasil yang optimal parameter MPC di-tuning menggunakan metode fine-tuning, yang kemudian dibandingkan kinerjanya dengan pengendali PI yang di­-tuning menggunakan autotuner yang sudah tersedia pada simulator HYSYS. Hasil simulasi menunjukan bahwa MPC memberikan hasil yang lebih baik dibanding pengendali PI dengan peningkatan kinerja pengendalian sebesar 54.4% dalam uji pelacakan setpoint. Selain itu, uji gangguan pun dilakukan dengan meningkatkan laju alir umpan kolom distilasi reaktif sebesar 10%. Pada uji gangguan MPC memberikan respon yang lebih cepat dan stabil sehingga menghasilkan peningkatan kinerja pengendalian sebesar 64.4% dibanding pengendali PI. ......Tert amyl methyl ether (TAME) is an ether used as oxygenated fuel additive that can be synthesized using reactive distillation. The major problem with the use of reactive distillation is the existence of the combination of reaction and separation on a single column that makes the reactive distillation process become very complex systems due to its interaction among process variables. Therefore, it is very important to use the types of control methodologies that can stabilize the operating condition and provide satisfactory control performance due to the complexity of the reactive distillation process dynamics such as model predictive control (MPC). In this study, a simulation of plantwide control by MPC and PI for TAME production is investigated in HYSYS V11. In this research, the dynamics model representing the process was approached by the first order plus dead time (FOPDT) model. MPC was tuned by fine-tuning method, meanwhile the PI controller was tuned by autotuner that is available in HYSYS. The results show that MPC can produce an improvement in setpoint tracking test by 54.4% compared to the PI controller. A disturbance of 10% increases in the feed flow rate of reactive distillation was done to see the controller responses. MPC has faster dan more stable responses than the PI controller and 64.4% improvement was produced by MPC compared to the PI controller.
Depok: Fakultas Teknik Universitas Indonesia, 2020
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Fransiscus Adam Perkasa
Abstrak :
Gas yang dijual harus memenuhi kualitas tertentu diantaranya memiliki kandungan air maksimum 4-7 lb/MMSCF. Untuk mencapai kualitas tersebut diperlukan proses Gas Dehydration Unit (GDU) menggunakan absorpsi dengan glikol. Jenis glikol yang dipakai adalah Trietilen Glikol (TEG). Pada sistem steady state dibuktikan bahwa nilai kandungan air maksimum yang terdapat pada sales gas hanya mencapai 3 lb/MMSCF yaitu dibawah standard sales gas sehingga dapat dikatakan Gas Dehydration Unit ini optimum. Akan tetapi sifat dari proses dipabrik adalah dinamis, disebabkan adanya gangguan pada proses tersebut. Gangguan tersebut menyebabkan ketidakefektifan dan ketidakstabilan pada proses tersebut, bahkan dapat menyebabkan kondisi bahaya, karena itu diperlukan pengendalian proses. Pengendalian proses yang diperlukan adalah yang mampu mempertahankan proses pada kondisi optimumnya. Dalam penelitian ini akan dirancang pengendalian proses dengan pengendali Proportional Integral (PI) yang bekerja pada kondisi optimumnya. Penyetelan pengendali dilakukan dengan dua metode yaitu Ziegler Nichols dan Lopez. Sebagai hasilnya, pengendalian yang optimum pada pengendali tekanan unit absorber T-100 menggunakan Ziegler Nichols dengan nilai Kp dan Ti-nya adalah 87,5 dan 1,7. Pada pengendali suhu pada unit absorber T-100 menggunakan Lopez dengan Kp dan Ti-nya adalah 0,31 dan 20,08. Pada pengendali suhu unit regenerator T-101 menggunakan Lopez, pada pengendali suhu stage 2 nilai Kp dan Ti-nya adalah 0,25 dan 118. Sedangkan pada pengendali suhu stage 5 nilai Kp dan Ti-nya adalah 0,18 dan 14,35. ......Sales Gas must meet certain quality which has a maximum water content 4-7 lb MMSCF. To achieve the required quality of the process, Gas Dehydration Unit (GDU) using absorption with glycol. Type of glycol used for this process is Triethylene Glycol (TEG). At steady state system proved that the value of the maximum water content contained in the sales gas only 3 lb/MMSCF which is lower than the standard sales gas specification, so it can be said that Gas Dehydration Unit is optimum. However, the characteristic process in real plant is dynamic, because there was disturbance in the process. The disturbance causes inefficiencies and instability in the process, and that can be dangerous too, so this plant need process control. Process control that is needed is a process control that is able to maintain the optimum condition. The process control design in this research is using Proportional Integral (PI) controller for optimum work. Controller tuning is done in two methods, Ziegler Nichols and Lopez. As a result, optimum control in pressure absorber T-100 is using Ziegler Nichols tuning with its Kp and Ti each valued 87,5 and 1,7. Optimum control in temperature absorber T-100 is using Lopez tuning with its Kp and Ti each valued 0,31 and 20,08. While most optimum method of regenerator T-101 temperature control is using Lopez tuning with its Kp and Ti for stage 2 each valued 0,25 and 118. For stage 5 its Kp and Ti each valued 0,18 and 14,35.
Depok: Fakultas Teknik Universitas Indonesia, 2015
S65719
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2   >>