"Dengan meningkatnya permintaan listrik, diharapkan pembangkit listrik dari energi terbarukan dapat membantu memenuhi kebutuhan masyarakat. Salah satunya adalah solar sistem tenaga yang menggunakan teknologi panel surya. Panel surya dapat mengubah sinar matahari menjadi energi listrik DC. Dengan bantuan inverter, energi listrik DC itu diproduksi oleh panel surya akan diubah menjadi energi listrik AC. Namun, Teknologi inverter ini menghasilkan gangguan pada rentang frekuensi 9 kHz - 150 kHz karena frekuensi switching di inverter.
Dalam penelitian ini, 2 jenis pengukuran dilakukan. Pertama, iradiasi matahari pengukuran dengan perangkat meteran tenaga surya. Kedua, gangguan pengukuran pada sistem panel surya off grid dengan perangkat Picoscope 3425. Pengukuran ini dilakukan secara bersamaan. Beban listrik (resistif, induktif, dan kapasitif) dicolokkan pada sistem dan diukur hari yang berbeda.
Berdasarkan hasil pengukuran, nilai gangguan tertinggi pada frekuensi 74 kHz. Urutan beban listrik dengan nilai gangguan tertinggi di iradiasi ± 200 W / m2, ± 400 W / m2, dan ± 600 W / m2 adalah induktor, kapasitor, dan resistor. Sedangkan untuk urutan beban listrik dengan yang tertinggi nilai gangguan pada iradiasi ± 800 W / m2 dan ± 1000 W / m2 adalah resistor, induktor, dan kapasitor. Penelitian ini menunjukkan bahwa semakin tinggi iradiasi matahari terkena panel surya, semakin tinggi gangguan tegangan yang dihasilkan dari sisi keluaran dari inverter.

With the increasing demand for electricity, it is expected that electricity generation from renewable energy can help meet the needs of the community. One of them is a solar power system that uses solar panel technology. Solar panels can convert sunlight into DC electrical energy. With the help of an inverter, the DC electrical energy produced by solar panels will be converted into AC electrical energy. However, This inverter technology produces interference in the frequency range of 9 kHz - 150 kHz because of the switching frequency at the inverter.
In this study, 2 types of measurements were made. First, solar irradiation measurements with a solar meter. Secondly, interference measurements on off grid solar panel systems with the Picoscope 3425 device. These measurements are carried out simultaneously. Electric load (resistive, inductive, and capacitive) plugged into the system and measured different day.
Based on the measurement results, the highest disturbance value is at 74 kHz. The sequence of electrical loads with the highest interference value in irradiation is ± 200 W / m2, ± 400 W / m2, and ± 600 W / m2 are inductors, capacitors, and resistor. As for the sequence of electrical loads with the highest interference value at irradiation ± 800 W / m2 and ± 1000 W / m2 are resistors, inductors, and capacitors. This research shows that the higher the sun's irradiation exposed to solar panels, the higher the interference voltage generated from the output side of the inverter.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dyan Puspita Apsari
"ABSTRAK
Pertumbuhan kebutuhan energi listrik memicu aliran daya yang semakin meningkat, begitu pula dengan perkembangan teknologi yang menyebabkan kebutuhan akan internet semakin meningkat. Dengan kemajuan teknologi saat ini, sudah terdapat suatu alat yang dapat memberikan jaringan ethernet dalam jarak yang lebih jauh. Alat tersebut merupakan alat komunikasi data menggunakan prinsip power line carrier (PLC), yaitu alat yang bekerja menggunakan dua adapter dengan mengubah sinyal ethernet menjadi sinyal powerline, dan menggunakan jaringan listrik 220-380V untuk komunikasi data tanpa membutuhkan kabel tambahan sebagai perantaranya. Namun, ketika jaringan listrik AC digunakan untuk mentransmisikan sinyal, kemungkinan gangguan dari disturbansi yang dihasilkan oleh sistem lain pada jaringan daya yang sama menjadi sangat tinggi. Pada penggunaan teknologi power line carrier sinyal pada rentang frekuensi tertentu akan dibangkitkan untuk tujuan komunikasi. Akan tetapi sinyal yang dibangkitkan ini menjadi disturbansi bagi alat lain yang tidak terlibat dalam proses komunikasi dan dapat mempengaruhi kinerja peralatan lain. Disisi lain, peralatan yang digunakan oleh rumah tangga akan memancarkan disturbansi pada rentang frekuensi 9-150 kHz yang dapat mempengaruhi sistem transmisi sinyal dan akan menghasilkan karakteristik yang berbeda-beda. Disturbansi akan mempengaruhi operasi kerja peralatan lain dan proses transmisi komunikasi data yang menyebakan frekuensi sinyal meningkat atau menurun. Penelitian ini memiliki fokus pada pengaruh disturbansi rentang frekuensi 9-150 kHz, dimana akan diukur pengaruh disturbansi terhadap komunikasi data yang menggunakan media power line carrier. Untuk variansi disturbansi digunakan beban rumah tangga, yaitu microwave inverter dan kompor induksi sebagai peralatan sumber disturbansi. Dengan menggunakan picoscope untuk melihat dan merekam disturbansi, data tersebut kemudian diolah dengan metode FFT dalam MATLAB untuk didapatkan karakteristik disturbansi pada setiap peralatan. Selanjutnya, dilihat pengaruh disturbansi tersebut terhadap komunikasi data yang mengalir pada jaringan listrik yang digunakan. Berdasarkan hasil penelitian, dapat disimpulkan bahwa nilai disturbansi yang dihasilkan oleh peralatan rumah tangga pada frekuensi 19 kHz akan mempengaruhi kualitas transfer atau komunikasi data pada power line carrier. Dimana pada kelima pengujian, semakin meningkatnya nilai disturbansi dengan nilai rata-rata sebesar 725.2 mV, 940.9 mV, 1060.4 mV, 1447.4 mV, dan 1673.9 mV akan mengakibatkan peningkatan packet loss sebesar 0.0037%, 0.201%, 0.25%, 0.5%, dan 0.5252%.

ABSTRACT
The growth of electrical energy needs triggers an increasing power flow, as well as the technological developments that cause the Internet needs to increase. With the advancement of current technology, there is already a tool that can provide Ethernet network in a much longer distance. The tool is a data communication tool using the principle of power line carrier (PLC), which is a tool that works using two adapters by converting the Ethernet signal into a powerline signal, and using a 220-380V power grid for data communication without needing additional cables as its medium. However, when the AC power grid is used to transmit the signal, the likelihood of interference from disturbance generated by other systems on the same power network becomes very high. On the use of power line carrier signal technology on certain frequency ranges will be raised for communication purposes. However, this raised signal becomes a disturbance for other tools that are not involved in the communication process and may affect the performance of other equipment. On the other hand, equipment used by households will emit disturbance at a frequency range of 9-150 kHz that can affect the signal transmission system and will produce different characteristics. The disturbance will affect the work operation of other equipment and the transmission process of data communication that degrade signal frequencies increasing or decreasing. This research has a focus on the influence of disturbance frequency range of 9-150 kHz, which will be measured disturbance influence on data communication using the power line carrier media. For variances disturbance used household load, namely microwave inverter and stove induction as a source equipment disturbance. By using a picoscope to view and record disturbance, the data is then processed by FFT method in MATLAB to be obtained disturbance characteristics of each equipment. Furthermore, the Disturbance influence the data communication that flows in the electricity network used. Based on the results of the study, it can be concluded that the disturbance value produced by household appliances at 19 kHz frequency will affect the quality of transfer or data communication in the power line carrier. Where in the fifth Test, the increasing value of disturbance with an average value of 725.2 mV, 940.9 mV, 1060.4 mV, 1447.4 mV, and 1673.9 mV will result in increased packet loss of 0.0037%, 0201%, 0.25%, 0.5%, and 0.5252%."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Galuh Prameswari
"Saat ini banyak sekali peralatan rumah tangga yang menggunakan teknologi inverter untuk meningkatkan efisiensi energi. Namun setelah diteliti oleh para ilmuwan, penggunaan teknologi ini dapat menimbulkan gangguan pada rentang frekuensi 9-150 kHz. Hotel sebagai tempat pengoperasian beberapa peralatan, memiliki sistem instalasi tenaga listrik seperti soket listrik, ruang panel dan panel lantai. Gangguan yang ditimbulkan oleh setiap peralatan rumah tangga pada frekuensi 9-150 kHz menghasilkan karakteristik yang berbeda. Karakteristik yang berbeda juga akan terjadi jika pengukuran dilakukan pada tiga titik berbeda pada sistem instalasi listrik.
Penelitian ini berfokus pada karakteristik rentang frekuensi gangguan 9-150 kHz yang ditimbulkan oleh peralatan rumah tangga. Dalam penelitian ini penyedot debu digunakan sebagai perangkat sumber gangguan. Dalam studi ini, dua jenis penyedot debu yang digunakan. Mereka memiliki kekuatan yang berbeda dan model yang berbeda tetapi mereka adalah merek yang sama. Ada 2 jenis mode yang digunakan di setiap vakum, yaitu mode tanpa beban dan mode beban penuh. Dengan menggunakan Picoscope untuk melihat dan merekam gangguan, maka diperoleh data gangguan dengan metode FFT di Matlab, diperoleh karakteristik gangguan pada frekuensi 9-150 kHz.
Berdasarkan hasil penelitian, terdapat perbedaan nilai gangguan dan frekuensi antara tidak ada penyedot debu dengan saat ada penyedot debu. Jika tidak ada penyedot debu, didapatkan gangguan pada frekuensi 50 kHz pada 3 titik pengukuran yaitu soket, panel ruang dan panel lantai. Sedangkan pada penyedot debu, didapatkan gangguan pada frekuensi 11-16 kHz. Di mana frekuensi 11 kHz disebabkan oleh perawatan penyedot debu tipe B tanpa mode beban, frekuensi 12 kHz disebabkan perawatan penyedot debu tipe A tanpa mode beban, frekuensi 13 kHz disebabkan oleh perawatan penyedot debu tipe B dengan mode beban penuh, frekuensi 16 kHz disebabkan perawatan penyedot debu tipe A dengan mode beban penuh.

Nowadays there are so many household appliances use inverter technology to improve energy efficiency. However, after being investigated by scientists, the use of this technology can cause interference in the frequency range 9-150 kHz. The hotel as a place to operate several equipment, has an electric power installation system such as electric sockets, panel rooms and floor panels. Interference caused by each household appliance at a frequency of 9-150 kHz produces different characteristics. Different characteristics will also occur if measurements are made at three different points in the electrical installation system.
This study focuses on the characteristics of the frequency range of interference from 9-150 kHz caused by household appliances. In this study, a vacuum cleaner was used as a source of interference. In this study, two types of vacuum cleaners were used. They have different strengths and different models but they are the same brand. There are 2 types of modes used in each vacuum, namely no-load mode and full-load mode. By using the Picoscope to view and record the disturbance, the disturbance data obtained by the FFT method in Matlab, obtained the disturbance characteristics at a frequency of 9-150 kHz.
Based on the research results, there is a difference in the value of the disturbance and frequency between the absence of a vacuum cleaner and when there is a vacuum cleaner. If there is no vacuum cleaner, interference is obtained at a frequency of 50 kHz at 3 measurement points, namely the socket, room panel and floor panel. Whereas in the vacuum cleaner, interference is obtained at a frequency of 11-16 kHz. Where the frequency of 11 kHz is due to the treatment of the type B vacuum cleaner without load mode, the frequency of 12 kHz is due to the maintenance of the type A vacuum cleaner without load mode, the frequency of 13 kHz is due to the maintenance of the type B vacuum cleaner with full load mode, the frequency of 16 kHz is due to the maintenance of the vacuum cleaner type A dust with full load mode.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf