Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 4 dokumen yang sesuai dengan query
cover
Sugeng Supriadi
Abstrak :
Demand for dental health care is increasing, especially in the Orthodontic field. The main objective of orthodontic treatment is to restore malocclusion conditions. Malocclusion causes aesthetics issues for the patient’s face and several discomforts like a difficulty in breathing or swallowing or speaking. If not repaired, a malocclusion could lead to other diseases, such as a greater risk of perforated teeth, gum irritation and temporomandibular disorder or pain in the lower jaw. Malocclusion can be remedied by Orthodontic Brackets. This research aim is to fabricate an orthodontic bracket that is suitable for the teeth structure of the Indonesian people. The fabrication method uses an Investment Casting process. The results show that orthodontic brackets have been successfully produced within an acceptable geometric tolerance, with the exception that surface finish quality has to be improved.
Depok: Faculty of Engineering, Universitas Indonesia, 2015
UI-IJTECH 6:4 (2015)
Artikel Jurnal  Universitas Indonesia Library
cover
Tamie Widjaya
Abstrak :
ABSTRAK
Plak gigi merupakan salah satu masalah umum yang dapat ditemui pada saat penggunaan braket ortodontik. Hal ini terjadi karena adanya penumpukan bakteri di antara braket dan juga gigi yang di mana bakteri berasal dari sisa makanan. Tujuan dari penelitian ini ialah untuk menciptakan permukaan braket yang memiliki energi yang rendah sehingga memudahkan air untuk membersihkan sisa makanan, yakni dengan sifat hidrofobik. Sifat tersebut dapat dicapai dengan menggunakan perlakuan etsa kimia yang diikuti dengan modifikasi permukaan menggunakan stearic acid. Etsa yang digunakan ialah CuCl2 dan HCl dengan variasi waktu berbeda, yaitu 15, 30, 45 dan 60 detik untuk CuCl2 dan 40, 50, 60 dan 70 menit untuk HCl, variasi konsentrasi HCl yang berbeda, yaitu 1, 2 dan 3 M, dan juga variasi suhu yang berbeda untuk etsa HCl, yaitu 25oC, 40oC, 60oC dan 80oC. Hasilnya menunjukkan bahwa dengan menggunakan 2 M HCl selama 70 menit pada suhu 80oC maka akan menghasilkan sudut kontak sebesar 152o. Struktur hidrofobik pada penelitian ini telah berhasil di lakukan dengan menggunakan metode pengetsaan yang kemungkinan dapat di gunakan pada braket ortodontik.
ABSTRACT
Dental rsquo s plaque is a common problem that encountered during orthodontic treatment using bracket. It was caused by the excess food which trapped between teeth and bracket and led to the accumulation of bacteria. The purpose of this study is to created bracket rsquo s surface which has low surface energy so it could easily be cleaned with water so it would reduce food attachment, which is hydrophobic surface. Hydrophobic surface could be achieved by using wet chemical etching and surface modification. CuCl2 and HCl was used as an etchant while stearic acid was used for surface modification. Hydrophobic surfaces were produced under various etching time i.e 15,30,45 and 60 seconds for CuCl2 and 40, 50, 60 and 70 minutes for HCl, various HCl concentration i.e 1,2 and 3 M, and also various temperature i.e 25oC, 40oC, 60oC and 80oC. The result showed the contact angle could be achieved up to 152o using 2 M HCl for about 70 minutes in 80oC. Hydrophobic structure has successfully fabricated using etching technique that might be applied to the orthodontic bracket.
2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Doloksaribu, Martin
Abstrak :
Tesis ini meneliti mengenai persentase keterisian microcavity pada cetakan braket ortodontik dengan proses Metal Injection Molding (MIM). Braket ortodontik memiliki microcavity pada bagian sayap dan dasar (base). Berbeda dengan proses pengisian pada MIM konvensional, proses injeksi/pengisian microcavity (μMIM) harus dilakukan dengan cepat. Pada penelitian ini dilakukan simulasi dan injeksi cetakan braket ortodontik dengan MIM terhadap volume feeder. Feeder 1 memiliki volume (luas penampang runner-gate) kecil dan Feeder 2 memiliki volume (luas penampang runner-gate) besar. Simulasi pada Feeder 1 menghasilkan keterisian penuh pada temperatur material 200oC. Simulasi pada Feeder 2 menghasilkan keterisian penuh pada temperatur material 190oC. Aliran material pada injeksi Feeder 1 tidak dapat mencapai gate pada temperatur material 200oC dan tekanan injeksi 1600 kgf/cm2. Aliran material dapat mencapai ujung Feeder 2 pada temperatur material 165~200oC dan tekanan injeksi 1050~1600 kgf/cm2 namun keterisian cavity produk tidak penuh. Simulasi dan eksperimen injeksi memberikan hasil yang berbeda pada keterisian microcavity. Volume feeder yang lebih besar memberikan keterisian microcavity lebih baik. ......This thesis examines the filling percentage of microcavity in orthodontic bracket molds using the Metal Injection Molding (MIM). Orthodontic brackets have microcavities on the wing and base. Unlike the conventional MIM, microcavities on the microinjection (μMIM) were filled rapidly. In this study, simulation and injection of orthodontic bracket molds were carried out on the different volumes of the feeder. Feeder 1 was a small volume feeder (smaller cross-sectional area of runner and gate) and Feeder 2 is a large volume feeder (larger cross-sectional area of runner and gate). Simulations on Feeder 1 produce a complete filling at a material temperature of 200oC. Simulation on Feeder 2 produces complete filling at a material temperature of 190oC. The flow of injected material in Feeder 1 was unable to reach the gate at a material temperature of 200oC and an injection pressure of 1600 kgf/cm2. The flow of injected material in Feeder 2 was able to fill the cavity at a material temperature of 165~200oC and an injection pressure of 1050~1600 kgf/cm2 however one of wing (microcavity) was still incompletely filled. Injection simulations and experiments gave different results on the filling percentage of microcavity. A larger feeder volume provides a better filling percentage of microcavity.
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Hantoro Restucondro Saputro
Abstrak :
Maloklusi merupakan salah satu masalah yang umum ditemui pada gigi dan mulut orang Indonesia. Negara ini juga dihadapkan pada masalah yang mengharuskan mengimpor braket dari luar negeri. Tujuan dari penelitian ini yaitu untuk memproduksi braket ortodontik nasional dengan proses metal injection molding MIM di Indonesia, khususnya sintering dengan menggunakan kondisi vakum dengan menggunakan stainless steel 17-4 PH, karena material ini merupakan salah satu material yang umum digunakan untuk aplikasi braket ortodontik. Sintering dilakukan pada empat temperatur yang berbeda, yaitu 1320°C, 1340°C, 1360°C, dan 1380°C. Hasil penelitian menunjukkan bahwa terdapat inklusi di dalam stainless steel 17-4 PH pada produk sintering yang kemungkinan adalah senyawa silikon oksida, kromium oksida, atau besi oksida. Densitas relatif meningkat seiring dengan naiknya temperatur sintering karena area porositas yang semakin berkurang. Selain itu, hasil sintering pada 1360 C memiliki kekerasan paling optimal, yaitu sebesar 395 HV dan melebihi kekerasan dari braket ortodontik komersial. ...... Malocclusion is one of the common problems encountered in the teeth and mouth of Indonesian people. This country is also confronted with problems that the bracket have to been imported from abroad. The purpose of this study is to produce national orthodontic bracket with metal injection molding MIM in Indonesia, particularly by using vacuum sintering for 17 4 PH stainless steel because it is a material commonly used for orthodontic bracket applications. Sintering conducted at four different temperatures, at 1320°C, 1340°C, 1360°C, and 1380°C. The results showed that there are inclusions in 17 4 PH stainless steel sintering products, it might be silicon oxide, chrome oxide, or iron oxide. The relative density increases with increasing temperature sintering because the area of porosity are reduced. In addition, the results of sintering at 1360 C has the optimal hardness, which is amounted to 395 HV and higher than commercial orthodontic bracket.
Depok: Fakultas Teknik Universitas Indonesia, 2017
S66577
UI - Skripsi Membership  Universitas Indonesia Library