Renita Hasna Febrianti
"Penelitian ini membahas karakter dua digital radiography (MobileDiagnost wDr dan Essenta DR Compact) menggunakan fantom in-house dan fantom pro-digi dilihat dari kualitas citranya. Parameter kualitas citra direpresentasikan sebagai koefisien linearitas (CL) yaitu korelasi antara Signal Difference to Noise Ratio (SDNR) dengan kedalaman obyek, dan koefisien variasi (CV) yaitu konsistensi nilai SDNR obyek terhadap perubahan ukuran. Selain itu, Modulation Transfer Function (MTF) juga dievaluasi sebagai parameter tambahan. Pengambilan citra dilakukan dengan empat variasi filter (0 mm Al, 1 mm Al + 0.1 mm Cu, 1 mm Al + 0.2 mm Cu, dan 2 mm Al) juga dengan dan tanpa antiscatter grid. Penelitian ini menunjukan desain dari fantom in-house dapat digunakan untuk Quality control (QC) pada sistem DR tetapi penggunaannya tidak dapat digeneralisasi pada semua DR dikarenakan setiap alat memiliki karakteristik masing-masing.

This study aims to discuss the characteristics of two digital radiography systems, namely Mobile Diagnosis WDR and Essenta DR Compact using in-house phantoms and Pro-Digi in terms of image quality. Proposed image quality parameters are linearity coefficients (CL), namely the correlation between the Signal Difference to Noise Ratio (SDNR) and the depth of the object, and the coefficient of variation (CV), namely the consistency of the SDNR value of an object to size change. In addition, Modulation Transfer Function (MTF) was also evaluated as additional parameter. Phantom images were taken with four filter variations (0 mm Al, 1 mm Al + 0.1 mm Cu, 1 mm Al + 0.2 mm Cu, and 2 mm Al) with and without antiscatter grid. This study shows that the in-house phantom can be utilized for Quality Control (QC) in the DR system but its use cannot be generalized to all DRs due to unique characteristics of each devices."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rhesa Almerzada Shah Putera
"Pada era globalisasi yang sangat pesat berkembang, terdapat sebuah cetusan dalam bidang teknologi informasi yaitu media sosial. Dewasa ini, media sosial memiliki peran penting untuk membangun citra manusia sebagai penggunanya, khususnya melalui media visual berupa foto. Latar dari setiap foto yang diunggah adalah faktor yang sangat mendukung untuk pembangunan citra, sehingga bertambahnya angka penciptaan ruang berfoto yang biasa dikenal dengan istilah photogenic space. Salah satu yang menunjang segi estetika dari sebuah photogenic space adalah cahaya.
Peran cahaya untuk menciptakan pengalaman dan persepsi visual pada ruang akan sangat mempengaruhi suasana dan kualitas pada foto. Pada penulisan ini, diharapkan akan mendapatkan indikator yang jelas terkait pencahayaan dalam foto sehingga apa yang membentuk sebuah photogenic space bisa lebih jelas terukur. Perbedaan kontras antara subjek dengan latarnya akan menjadi penilaian objektif yang akan diukur pada penulisan ini.
Metode pengumpulan data yang digunakan dalam penulisan skripsi ini adalah studi literatur dengan mempelajari teori dari jurnal dan buku tentang pencahayaan, ruang komersil, dan pembangunan citra di media sosial. Sintesis teori yang didapatkan akan ditinjau melalui studi kasus untuk membuktikannya. Studi kasus akan dilakukan menggunakan simulasi dan kuesioner untuk memperkuat argumen.
Berdasarkan hasil penelitian didapatkan bahwa penciptaan photogenic space di era ini akan memiliki pengaruh yang besar di media sosial. Dan untuk menciptakan sebuah photogenic space dibutuhkan peran pencahayaan yang bisa menghasilkan kontras antara subjek foto dengan latarnya. Kondisi ini bisa didapatkan dengan mengatur intensitas paparan cahaya serta temperatur warna pada subjek dan latarnya.

"
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Desy Natalia Marjaya
"Penelitian ini bertujuan untuk membuat fantom payudara yang menerapkan analisis kontras detail dengan latar berstruktur untuk uji kualitas citra pada modalitas Mamografi dan Digital Breast Tomosynthesis. Penelitian ini dibagi menjadi 3 tahap, yakni; pembuatan, validasi, dan studi aplikasi fantom. Tahap pembuatan fantom mencakup pemilihan material fantom serta desain dan fabrikasi fantom. Pada tahap validasi, faktor eksposi dan nilai piksel dari citra fantom dibandingkan dengan mamogram klinis. Pada tahap studi aplikasi, fantom untuk menguji kualitas citra Mamografi dan DBT dengan mengukur signal-to-difference noise ratio (SDNR), dan ketajaman citra (Full width half maximum (FW HM) dan artifact spread function (ASF)) pada 3 level dosis (1/2 automatic exposure setting (AEC), AEC dan 2 AEC). Contrast detail structured phantom berhasil diproduksi dengan variasi ukuran dan posisi objek mikrokalsifikasi. Nilai piksel target memiliki kesamaan 85,34 %, dengan nilai piksel mikrokalsifikasi mamogram klinis, sedangkan latar fantom memiliki kesamaan 86,07 % dengan jaringan payudara pasien. Studi aplikasi menunjukkan bahwa fantom dapat digunakan untuk menguji kualitas citra khususnya terkait detail mikrokalsifikasi. Perbedaan posisi target dan level dosis mempengaruhi hasil pengukuran. Contrast detail structured phantom telah berhasil diproduksi dan diujicobakan; fantom ini dapat digunakan untuk menguji kualitas citra pesawat mamografi dan DBT dengan mempertimbangkan struktur heterogen pada jaringan payudara


This work is aimed to construct a contrast detail structured phantom for mammography and Digital Breast Tomosynthesis. The study was divided into 3 stages: production, validation and application. Production stage covered materials preparation, design and fabrication phantom. In validation stage, the phantom was compared to clinical mammogram in terms of exposure settings used in the image acquisition and their pixel values. Last stage was to study the application of the phantom to assess the image quality of mammography and DBT systems in terms of signal difference-to-noise ratio (SDNR), and sharpness (fullwidth half maximum, FWHM and artifact spread function, ASF) at 3 dose level (1/2 × automatic exposure control (AEC), AEC and 2 × AEC settings). The contrast detail structured phantom was successfully created with variations on microcalcification object size and position. In comparison with clinical mammogram, maximum pixel value of Sn sphere shows 85,34 % similarity while their background tissue had 86,07 % similarity. The study of applications of the phantom shows that the phantom can be used to assess the image quality particularly to detail of microcalcifications. The position of targets and dose level settings afflicted the measured parameters. The contrast detail structured phantom has been successfully construct and studied; this phantom allows assessing image quality of digital mammography and DBT by including the presence of structured breast tissue -like

"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jimmy Sunny
"Latar belakang: MRCP merupakan teknik pencitraan tidak invasif untuk mengevaluasi anatomi dan mendeteksi kelainan sistem bilier. Cairan di saluran bilier akan memperlihatkan sinyal yang tinggi pada MRCP. Salah satu keterbatasan pemeriksaan MRCP ialah cairan di saluran gastrointestinal juga memberikan sinyal tinggi yang dapat mengganggu evaluasi saluran bilier. Sari buah nanas dapat menjadi kontras oral negatif untuk menurunkan sinyal di gastrointestinal. Belum terdapat penelitian penggunaan sari buah nanas pada pemeriksaan MRCP di Indonesia dan belum terdapat penelitian yang menilai visualisasi cabang-cabang duktus intrahepatikus setelah pemberian sari buah nanas. Tujuan: Mengukur perbedaan SNR gaster dan duodenum serta perubahan tingkat visualisasi cabang-cabang duktus bilier intrahepatikus sesudah pemberian sari buah nanas pada pemeriksaan MRCP. Metode: Dilakukan pemeriksaan MRCP sebelum dan sesudah pemberian sari buah nanas pada subjek penelitian. Mengukur perbedaan rerata SNR gaster dan duodenum serta mengukur perubahan tingkat visualisasi cabang-cabang duktus bilier intrahepatikus sebelum dan sesudah pemberian sari buah nanas. Perbedaan rerata SNR gaster dan duodenum dianalisis menggunakan uji Wilcoxon dan perubahan tingkat visualisasi dianalisis dengan uji McNemar untuk menilai diskordans. Hasil: Didapatkan 25 subjek penelitian yang menjalani pemeriksaan MRCP sebelum dan sesudah pemberian sari buah nanas. Terdapat penurunan bermakna SNR gaster dan duodenum setelah pemberian sari buah nanas, 127,1 (18,7-1194,6) menjadi 42.2 (4,2-377,1) untuk gaster dan 64,1 (3,8-613.4) menjadi 44,6 (6,5-310,3) untuk duodenum (p < 0,05). Terdapat perubahan bermakna tingkat visualisasi duktus bilier intrahepatikus (p < 0,05, diskordans >50%) dengan peningkatan tingkat visualisasi duktus intrahepatikus kanan segmen anterior pada 66% pengamatan, duktus intrahepatikus kanan segmen posterior pada 58% pengamatan, dan 70% pengamatan untuk duktus intrahepatikus kiri. Simpulan: Pemberian sari buah nanas dapat menurunkan sinyal gaster dan duodenum pada pemeriksaan MRCP dan mempengaruhi tingkat visualisasi cabang-cabang duktus bilier intrahepatikus.

Background: MRCP is a non-invasive imaging technique for evaluating anatomy and detecting abnormalities of the biliary system. Fluid in biliary tract will show high signal on MRCP. One of the limitations of MRCP is high signal in gastrointestinal fluid which can interfere biliary tract evaluation. Pineapple juice as negative oral contrast can reduce signal in gastrointestinal tract. There have been no studies on the use of pineapple juice for MRCP in Indonesia, and no studies assessed the visualization of intrahepatic ductal branches after administration of pineapple juice. Objective: Measuring difference in gastric and duodenal SNR and changes of visualization of intrahepatic biliary ductal branches after administration of pineapple juice on MRCP. Methods: MRCP before and after administration of pineapple juice were performed on subjects. Gastric and duodenal SNR mean difference were measured, and analysis were done with Wilcoxon test. Level of visualization of intrahepatic biliary ductal branches were also measured and analysed with McNemar test for discordances. Results: There were 25 subjects underwent MRCP. Gastric and duodenal SNR were statistically decreased after administration of pineapple juice, 127.1 (18.7-1194.6) vs 42.2 (4.2-377.1) and 64.1 (3.8-613.4) vs 44.6 (6.5-310.3) respectively (p <0.05). Statistically significant difference was observed in visualization of intrahepatic ductal branches (p<0,05), discordance >50%) with increase in visualization of right duct anterior segment in 66% observation, right duct posterior segment in 58% observation, and 70% observation in left intrahepatic bile duct. Conclusion: Use of pineapple juice as negative oral contrast significantly reduce gastric and duodenal signal in MRCP also affect visualization of the intrahepatic biliary duct branches.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2020
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Jimmy Sunny
"Latar belakang: MRCP merupakan teknik pencitraan tidak invasif untuk mengevaluasi anatomi dan mendeteksi kelainan sistem bilier. Cairan di saluran bilier akan memperlihatkan sinyal yang tinggi pada MRCP. Salah satu keterbatasan pemeriksaan MRCP ialah cairan di saluran gastrointestinal juga memberikan sinyal tinggi yang dapat mengganggu evaluasi saluran bilier. Sari buah nanas dapat menjadi kontras oral negatif untuk menurunkan sinyal di gastrointestinal. Belum terdapat penelitian penggunaan sari buah nanas pada pemeriksaan MRCP di Indonesia dan belum terdapat penelitian yang menilai visualisasi cabang-cabang duktus intrahepatikus setelah pemberian sari buah nanas. Tujuan: Mengukur perbedaan SNR gaster dan duodenum serta perubahan tingkat visualisasi cabang-cabang duktus bilier intrahepatikus sesudah pemberian sari buah nanas pada pemeriksaan MRCP. Metode: Dilakukan pemeriksaan MRCP sebelum dan sesudah pemberian sari buah nanas pada subjek penelitian. Mengukur perbedaan rerata SNR gaster dan duodenum serta mengukur perubahan tingkat visualisasi cabang-cabang duktus bilier intrahepatikus sebelum dan sesudah pemberian sari buah nanas. Perbedaan rerata SNR gaster dan duodenum dianalisis menggunakan uji Wilcoxon dan perubahan tingkat visualisasi dianalisis dengan uji McNemar untuk menilai diskordans. Hasil: Didapatkan 25 subjek penelitian yang menjalani pemeriksaan MRCP sebelum dan sesudah pemberian sari buah nanas. Terdapat penurunan bermakna SNR gaster dan duodenum setelah pemberian sari buah nanas, 127,1 (18,7-1194,6) menjadi 42.2 (4,2-377,1) untuk gaster dan 64,1 (3,8-613.4) menjadi 44,6 (6,5-310,3) untuk duodenum (p < 0,05). Terdapat perubahan bermakna tingkat visualisasi duktus bilier intrahepatikus (p < 0,05, diskordans >50%) dengan peningkatan tingkat visualisasi duktus intrahepatikus kanan segmen anterior pada 66% pengamatan, duktus intrahepatikus kanan segmen posterior pada 58% pengamatan, dan 70% pengamatan untuk duktus intrahepatikus kiri. Simpulan: Pemberian sari buah nanas dapat menurunkan sinyal gaster dan duodenum pada pemeriksaan MRCP dan mempengaruhi tingkat visualisasi cabang-cabang duktus bilier intrahepatikus.

Background: MRCP is a non-invasive imaging technique for evaluating anatomy and detecting abnormalities of the biliary system. Fluid in biliary tract will show high signal on MRCP. One of the limitations of MRCP is high signal in gastrointestinal fluid which can interfere biliary tract evaluation. Pineapple juice as negative oral contrast can reduce signal in gastrointestinal tract. There have been no studies on the use of pineapple juice for MRCP in Indonesia, and no studies assessed the visualization of intrahepatic ductal branches after administration of pineapple juice. Objective: Measuring difference in gastric and duodenal SNR and changes of visualization of intrahepatic biliary ductal branches after administration of pineapple juice on MRCP. Methods: MRCP before and after administration of pineapple juice were performed on subjects. Gastric and duodenal SNR mean difference were measured, and analysis were done with Wilcoxon test. Level of visualization of intrahepatic biliary ductal branches were also measured and analysed with McNemar test for discordances. Results: There were 25 subjects underwent MRCP. Gastric and duodenal SNR were statistically decreased after administration of pineapple juice, 127.1 (18.7-1194.6) vs 42.2 (4.2-377.1) and 64.1 (3.8-613.4) vs 44.6 (6.5-310.3) respectively (p <0.05). Statistically significant difference was observed in visualization of intrahepatic ductal branches (p<0,05), discordance >50%) with increase in visualization of right duct anterior segment in 66% observation, right duct posterior segment in 58% observation, and 70% observation in left intrahepatic bile duct. Conclusion: Use of pineapple juice as negative oral contrast significantly reduce gastric and duodenal signal in MRCP also affect visualization of the intrahepatic biliary duct branches."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2020
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Nurul Aini
"Pada penelitian ini telah dilakukan studi karakter fantom pada sistem computed radiography (CR) Fuji dalam beberapa parameter kualitas citra yang direpresentasikan dalam evaluasi koefisien linearitas (CL), koefisien variasi (CV), dan modulation transfer function (MTF). Penelitian ini menggunakan tiga fantom yang berbeda sebagai pembanding dengan representasi tubuh abdomen. Koefisien linearitas merupakan nilai yang menunjukkan linearitas perubahan kontras terhadap perubahan kedalaman objek, sedangkan koefisien variasi menunjukkan nilai konsistensi kontras terhadap perubahan ukuran objek.
Hasil MTF menunjukkan resolusi spasial yang dievaluasi menggunakan metode slanted edge dengan menggunakan lempengan tembaga yang terdapat pada in-house phantom Hasil yang diperoleh dari penelitian ini adalah pada fantom in-house nilai yang direkomendasikan adalah 75 kV dengan filter 1 mm Al + 0.1 mm Cu untuk linearitas kontras, 65 kV dengan filter 2 mmAl untuk konsistensi kontras, dan 70 kV dengan filter 1 mm Al + 0.2 mm Cu untuk MTF. Sedangkan untuk fantom in-house diperoleh nilai 60 kV dengan filter 1 mm Al + 0.2 mm Cu untuk linearitas kontras dan 60 kV dengan filter 0 mm Al untuk konsistensi kontras.

This study was performed to characterize in-house phantoms on computed radiography (CR) systems in terms of image quality parameters that represented coefficient of linearity (CL), coefficient of variation (CV), and modulation transfer function (MTF). This study used three different phantoms as a comparison, combined with abdominal anatomy representation. The CL is a value that shows the changes of contrast linearity to the changes of object depth, while the coefficient of variation shows the value of contrast consistency to changes of object size.
MTF showed the spatial resolution that evaluated using the slanted edge method using copper slabs in the in-house phantoms. The results obtained from this study are that in-house phantom 1.0 is recommended to be used at 75 kV with filters 1 mm Al + 0.1 mm Cu for contrast linearity, 65 kV with 2 mmAl filters for contrast consistency and 70 kV with 1 mm Al filter + 0.2 mm Cu for MTF. As for the in-house phantom 2.0 the recommended conditions are 60 kV value with a filter of 1 mm Al + 0.2 mm Cu for contrast linearity and 60 kV with a 0 mm Al filter for contrast consistency.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aida
"Kontrol kualitas adalah proses penting dalam pencitraan kedokteran nuklir. Tujuan kontrol kualitas (QC) adalah untuk mendeteksi degradasi dari performa sistem peralatan pencitraan seperti Single Photon Emisssion Computed Tomography (SPECT). Evaluasi parameter kontrol kualitas SPECT menggunakan fantom Jaszczak dan fantom in-house. Fantom Jaszczak untuk evaluasi citra uniformitas, kontras dan resolusi spasial dan fantom in-house untuk evaluasi citra hot. Evaluasi uniformitas menunjukkan konsentrasi aktivitas rendah 0.068 MBq/ml menunjukkan standar deviasi tinggi ±18.6 sedangkan konsentrasi aktivitas tinggi 0.235 MBq/ml menunjukkan standar deviasi rendah ±14.2.
Hasil evaluasi kontras pada citra cold menunjukkan standar deviasi rendah ± 21.8 pada konsentrasi aktivitas terendah 0.068 MBq/ml dan standar deviasi tinggi ± 25.1 ditunjukkan pada konsentrasi aktivitas tinggi 0.235 MBq/ml, dan pada evaluasi citra hot standar deviasi rendah ±29.45 pada konsentrasi aktivitas terendah 0.5 MBq/ml dan standar deviasi tinggi ± 32.2 pada konsentrasi aktivitas tinggi 6.0 MBq/ml. Evaluasi pada standar deviasi menunjukkan kontras citra. Citra dengan standar deviasi tinggi menunjukkan kontras tinggi.

Quality control is an important process in imaging nuclear medicine. The aim of quality control (QC) is to detect degradation of the performance of imaging equipment systems such as Single Photon Emisssion Computed Tomography (SPECT). Evaluation QC SPECT parameters using Jaszczak phantom and in-house phantom. Jaszczak phantom for evaluation of uniformity, contrast and spatial resolution and in-house phantom for hot image evaluation. Uniformity evaluation showed a low activity concentration of 0.068 MBq/ml showed high standard deviation of ± 18.6 with high activity concentration of 0.235 MBq/ml showed low standard deviation ± 14.2.
The results contrast evaluation on cold images showed low standard deviation ± 21.8 at the lowest activity concentration of 0.068 MBq / ml and a high standard deviation of ± 25.1 was shown at a high activity concentration of 0.235 MBq/ml, and low standard standard deviation image evaluation ± 29.45 at the lowest activity concentration 0.5 MBq/ml and high standard deviation ± 32.2 at high activity concentration of 6.0 MBq/ml. Evaluation standard deviation shows image contrast. Images with high standard deviation showed high contrast.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
T52332
UI - Tesis Membership  Universitas Indonesia Library
cover
Khairunnisa Nazhifah Yudyawati
"ABSTRACT
Pada tahun 2016, Koulali et al., Menyelidiki tingkat kesalahan aktif di Jawa, dan dikatakan bahwa ada kesalahan aktif Baribis yang melintasi dan melewati beberapa kecamatan di Jakarta Selatan. Selain itu, Jakarta adalah salah satu kota metropolitan dan memiliki populasi dan infrastruktur yang padat, sehingga keamanan kota perlu dipertimbangkan terutama untuk potensi bencana alam. Salah satu cara adalah untuk mengidentifikasi potensi adanya kesalahan di Jakarta dengan fokus pada identifikasi adalah kesalahan Baribis yang dikatakan berada di seberang Jakarta Selatan. Penelitian dengan data gravitasi primer menggunakan metode MS-SVD yang didukung oleh metode MS-HDVD adalah metode yang baik untuk mengidentifikasi kesalahan. Penelitian ini juga melakukan metode pemodelan ke depan 2D untuk menentukan gambar cross-sectional dari permukaan bawah tanah dan besarnya atau kontras kepadatan di wilayah Jakarta. Sesar Baribis diperkirakan relatif Timur-Barat, sehingga jalur yang dibuat adalah Utara-Selatan. Pemrosesan dilakukan dengan membuat peta CBA kemudian melanjutkan ke atas kemudian melakukan metode SVD. Mengiris data diambil di peta SVD. Dengan MS-SVD, karakteristik patahan juga dikenal sebagai arah dan besarnya kemiringan. Metode MS-HDVD juga mendukung adanya kesalahan dalam data MS-SVD. Dengan metode MS-SVD dan MS-HDVD, ada atau tidaknya Baribis diketahui. Seperti halnya model 2D Jakarta, dapat dilihat juga potensi bahaya DKI Jakarta dengan melihat kontras kepadatannya.

ABSTRACT
In 2016, Koulali et al., Investigated the level of active error in Java, and it was said that there was an active Baribis error that crossed and passed through several sub-districts in South Jakarta. In addition, Jakarta is a metropolitan city and has a dense population and infrastructure, so city security needs to be considered especially for potential natural disasters. One way is to identify potential mistakes in Jakarta with a focus on identification is Baribis errors which are said to be across from South Jakarta. Research with primary gravity data using the MS-SVD method supported by the MS-HDVD method is a good method for identifying errors. This study also conducted a 2D forward modeling method to determine cross-sectional images of the underground surface and the magnitude or contrast density in the Jakarta area. The Baribis Fault is estimated to be relatively East-West, so the route made is North-South. Processing is done by making a CBA map then proceed to the top then do the SVD method. Slicing data is taken on SVD maps. With MS-SVD, the fault characteristic is also known as the direction and magnitude of the slope. The MS-HDVD method also supports errors in MS-SVD data. With the MS-SVD and MS-HDVD methods, the presence or absence of Baribis is known. Like the Jakarta 2D model, it can also be seen the potential danger of DKI Jakarta by looking at its contrast density."
2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arkan Tanriwa
"Shifu Semakin Lama Semakin Konyol adalah sebuah cerpen karya Mo Yan Cerpen ini bercerita tentang Ding Shikou seorang pekerjapabrik teladan yang mengalami PHK sebulan sebelum masa pensiunnya Dibantu dengan L Xiaohu anak buahnya ketika di pabrik Ding membangun sebuah bisnis kamar sewaan jam jaman yang kemudian menghantui dirinya akibat prinsip prinsip moralnya sendiri Melalui analisis tokoh alur latar serta judul makalah ini mengungkap kontras kepribadian antargenerasi yang tampak antara Ding dan L melalui reaksi mereka terhadap bisnis kamar sewaan Kemungkinan sumber perbedaan ini juga diteliti dengan melihat catatan sosiologis mengenai keadaan sosial yang telah dilalui serta membentuk Ding dan L
Shifu You rsquo ll do Anything for A Laugh is a short story by Mo Yan This story centers on Ding Shikou a model factory worker who was forced to resign a month before starting his retirement Helped by L Xiaohu his disciple while in factory Ding built a love hotel business that eventually haunted him due to his own moral values Through an analysis of characters plot setting as well as title this paper reveals the intergenerational contrast between Ding and L through their reactions to the love hotel business The possibilities for the source of the differences are also investigated through looking at notes about the social conditions that Ding and L may have been portrayed to go through"
Depok: Fakultas Ilmu Pengetahuan Budaya Universitas Indonesia, 2016
MK-pdf
UI - Makalah dan Kertas Kerja  Universitas Indonesia Library
cover
Muthiara Maharani Azis
"ABSTRAK
Analisa pengaruh pemilihan region of interest (ROI) telah dilakukan secara kuantitatif menggunakan citra fantom 3D mamografi dari 4 pesawat mamografi (Siemens Mammomat Inspiration, Hologic Selenia Dimensions, Philips MicroDose L50 dan Agfa CR) dengan faktor eksposi pada pengaturan AEC. Empat model konfigurasi ROI diinvestigasi berdasarkan variasi bentuk dan ukuran dari lesi target dan latar. Dilakukan kalkulasi terhadap parameter nilai piksel (PV), kontras, dan signal difference to noise ratio (SDNR). Hasil menunjukkan bahwa variasi ROI memberikan pengaruh signifikan pada nilai PV untuk deteksi massa berspikula dan mikrokalsifikasi, namun tidak berpengaruh signifikan pada deteksi massa tidak berspikula. Variasi ROI tidak memberikan pengaruh pada parameter kontras untuk deteksi semua jenis target. Pada parameter SDNR, variasi ROI hanya berpengaruh signifikan untuk deteksi mikrokalsifikasi.

ABSTRACT
A quantitative analysis on the influence of Region of Interest (ROI) selection was conducted using images of 3D structured phantom from four different digital mammography systems (Siemens Mammomat Inspiration, Hologic Selenia Dimensions, Philips MicroDose L50 and Agfa CR) under Automatic Exposure Control (AEC) setting. Quantitative assessment was done by measuring the given parameters; (1) pixel value (PV), (2) contrast, and (3) signal different to noise ratio (SDNR) under four models of ROI configuration varied by shape and size of lesion, as well as background. Results shown that varying the ROI gives significant effect on detection of spiculated masses and microcalcifications in term of its PV. The variation of ROI does not give significant effect in term of image contrast. For SDNR, the variation of ROI only gave significant effect on detection of microcalcifications.;"
2016
S65288
UI - Skripsi Membership  Universitas Indonesia Library