Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Gunawan
Abstrak :
Pengaruh penambahan iogam azirkonium (Zr) dan lanthanum (La) terhadap konduktivitas listrik dan ketahanan panas aluminium telah diteliti. Penelitian dilakukan terhadap tiga jenis cuplikan aluminium, yaitu aluminium kemurnian komersial (Cuplikan A), aluminium dengan tambahan Zr (Cuplikan B) serta aluminium dengan tambahan 0.04 % berat Zr dan La dengan kandungan La bervariasi(Cuplikan C). Cuplikan dibuat dengan proses penuangan dan pengerolan menjadi kawat berdiameter 3.52 mm. Konduktivitas listrik aluminium ditentukan dari pengukuran resistivitas listriknya menggunakan alat jembatan ganda Kelvin. Ketahanan panasnya ditentukan dari pengukuran kekuatan tarik cuplikan sebelum dan setelah pemanasan selama 1 jam pada temperatur bervariasi serta pengukuran kurva DSC(Differential Scanning Calforimetry). Untuk menjelaskan pengaruh penambahan unsur Zr dan La terhadap perubahan sifat aluminium, struktur mikro cuplikan juga diamati dengan mikroskop optik maupun elektron dan parameter kisi kristalnya dikonfirmasi dengan difraksi sinar-X. Hasil penetitian menunjukkan bahwa penambahan 0.04% berat Zr meningkatkan ketahanan panas aluminium dari 85.1 % menjadi 91 %, tetapi menurunkan konduktivitas listriknya dari 61.78 % 1ACS (International Annealed Copper Standard) menjadi 60.07 % IACS. Dengan menambahkan lanthanum ke dalam aluminium yang mengandung 0.04 ° berat Zr, konduktivitas listrik cuplikan B dapat ditingkatkan dari 60.07 menjadi 60.80 %IACS. Diperoleh indikasi kuat ?bahwa peningkatan ketahanan panas aluminium disebabkan oleh penghalusan butir dan terbentuknya fasa-fasa kedua di dalam aluminium, sedangkan peningkatan konduktivitas iistrik disebabkan adanya penurunan kelarutan unsur-unsur pengotor di dalam Iogam aluminium akibat penambahan unsur lanthanum. Berdasarkan data penefitian ini, ketahanan panas dan konduktivitas listrik cuplikan aluminium yang optimum dapat diperoleh dengan penambahan 0.04 % berat Zr dan 0.13 % berat La. ......A close study about the effects of the addition of zirconium (Zr) and lanthanum (La) metals on the condutivity and heat resistance of commercial purity aluminium has been carried out on the three kinds of aluminium samples consisting of commercial purity aluminium (Sample A), aluminium with the addition of Zr (Sample B), as well as aluminium with the addition of 0.04 wt % Zr and La (SampleC). The samples were made by casting and rolling processes to form a-3.52 mm wire in diameter. The electrical conductivity of the aluminium samples was determined by measuring the resistivity employing Kelvin double bridge instrument. The heat resistance properties were obtained by measuring their strength before and after heating the sample for one hour at various temperatures, and by measuring their DSC curves. To elucidate the effect of the addition of Zr and La to the properties of aluminium, their microstructures were also observed by the optical as well as electron microscopes and their lattice parameters were confirmed by X-ray diffraction. The results shows that the addition of 0.04 wt.% Zr increased the heat resistance of aluminium from 85.1% to 91.0 %, however it reduces their electrical conductivity from 61.78 % IACS (International Annealed Copper Standard) to 60.07 % IACS. By the addition of La into aluminium containing 0.04 % wt. %Zr, the electrical conductivity of the Sample B can be increased from 60.07 IACS to 60.80 %IACS. There is a strong indication that the increase of the heat resistance was caused by grain refinement and the second phase formation in the aluminium, whereas the increase in the electrical conductivity of aluminium was caused by a decrease in the solid solubility of impurities in the aluminium due to the addition of lanthanum elements. Based on the data from such study, the optimum heat resistance and electrical conductivity were obtainable by the addition of 0.04 wt. °A Zr and 0.13 wt. % La.
Depok: Program Pascasarjana Universitas Indonesia, 2000
T2099
UI - Tesis Membership  Universitas Indonesia Library
cover
Jihan Fajriah Kurniawan
Abstrak :
Indonesia merupakan negara berkembang yang banyak melakukan kegiatan pembangunan yang pada umumnya menggunakan beton dengan jenis OPC sebagai bahan bakunya karena mudah ditemukan di alam, murah dan perawatannya mudah. Namun, bahan OPC ini menimbulkan permasalahan pada lingkungan, yaitu menghasilkan gas emisi CO2 sebesar 6% setiap tahunnya. Semen geopolimer diyakini mampu menggantikan OPC dengan sifatnya yang lebih tahan panas, ramah lingkungan dan tahan korosi. Penelitian ini dilakukan untuk membuktikan ketahanan panas semen geopolimer berbasis metakaolin yang ditambahkan filler zirkon yang kemudian dibandingkan dengan semen refraktori lainnya, yakni semen kalsium aluminat. Sampel uji terdiri dari mortar geopolimer metakaolin (MK) yang telah dicampurkan larutan aktivator serta penambahan pasir zirkon sebanyak 20% dan mortar kalsium aluminat (CAC) sebagai pembandingnya yang selanjutnya dilakukan curing pada suhu ruang selama 28 hari. Kemudian, semua sampel diberikan perlakuan panas pada furnace hingga temperatur 400°C, 600°C dan 900°C selama 2 jam. Selanjutnya, sampel MK dan CAC dilakukan pengujian kuat tekan yang menyatakan bahwa semakin tinggi temperatur, maka nilai kuat tekan akan semakin meningkat, dan menunjukkan bahwa penambahan zirkon dapat meningkatkan kuat tekan sampel. Namun, pada karakterisasi XRD dan TG-DTA, penambahan zirkon ini tidak terlalu berpengaruh karena tidak munculnya fasa baru selain zirkon baik pada sampel MK maupun CAC. Maka, dapat disimpulkan bahwa penambahan zirkon hanya bersifat sebagai filler pengisi ruang kosong dan tidak memberikan efek signifikan terhadap sampel MK dan CAC. ......Indonesia is a developing country that carries out a lot of development activities which generally use OPC concrete as raw material because it is easy to find in nature, cheap and easy to maintain. However, this OPC material causes problems to the environment, which produces 6% CO2 gas emissions every year. Geopolymer cement is believed to be able to replace OPC with its heat resistance, environmental friendliness and corrosion resistance. This study was conducted to prove the heat resistance of metakaolin-based geopolymer cement added with zircon filler which was then compared with other refractory cement, namely calcium aluminate cement. The test samples consisted of metakaolin geopolymer mortar (MK) with 20% activator solution and zircon sand addition and calcium aluminate mortar (CAC) for comparison, which were cured at room temperature for 28 days. Then, all samples were heat treated in a furnace to temperatures of 400°C, 600°C and 900°C for 2 hours. Furthermore, MK and CAC samples were subjected to compressive strength testing which stated that the higher the temperature, the higher the compressive strength value, and showed that the addition of zircon could increase the compressive strength of the samples. However, in the XRD and TG-DTA characterization, the addition of zircon was not very influential because no new phases other than zircon appeared in both MK and CAC samples. So, it can be concluded that the addition of zircon is only a filler to fill the empty space and does not have a significant effect on the MK and CAC samples.
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Intan Hanifa
Abstrak :
Geopolimer pada aplikasinya sebagai material alternatif memerlukan kemampuan ketahanan panas yang baik sebagai bahan bangunan apabila terjadi kebakaran atau bahkan dapat dijadikan sebagai bahan refraktori. Penelitian ini dilakukan untuk mengetahui  ketahanan panas geopolimer berbasis metakaolin (GM) yang ditambahkan filler zirkon terhadap ketahanan panas yang dibandingkan dengan semen tahan api yaitu calcium aluminate cements (CAC). Sampel yang diteliti merupakan mortar geopolimer berbasis metakaolin dengan larutan NaOH + Na2SiO3 dengan ditambahkan sebanyak 20% pasir zirkon dan pasir ottawa sebagai pembanding. Kemudian setelah curing 28 hari sampel dilakukan variasi perlakuan panas yaitu yang tidak dipanaskan dan yang dipanaskan pada suhu 200°C selama 2 jam. Hasil pengujian kuat tekan pada suhu ruang sampel GM-zirkon memiliki kuat tekan lebih tinggi dibandingkan sampel GM-ottawa, hal ini dapat disebabkan karena pasir zirkon berperan sebagai filler yang dapat masuk di antara jaringan polisialat dan mengisi ruang kosong sehingga sifat mekanis GM dapat meningkat. Namun pada penelitian ini, kuat tekan sampel GM-zirkon lebih rendah dibandingkan dengan sampel CAC-zirkon sehingga dibutuhkan formula larutan aktivator yang lebih baik. Hasil pengujian TG-DTA terlihat sampel GM memiliki 3 peak dan sampel CAC memiliki 2 peak yang menggambarkan reaksi eksoterm dan endoterm. Selain itu, sampel GM mengalami penurunan berat dalam % lebih signifikan diakibatkan karena air yang menguap dibandingkan dengan sampel CAC. Hasil XRD juga menunjukkan sampel GM dan CAC dengan tambahan pasir zirkon tidak membentuk fasa baru baik yang di suhu ruang maupun di suhu 400°C. Dengan demikian, pasir zirkon yang ditambahkan tidak terlalu memberikan efek yang signifikan terhadap ketahanan panas geopolimer berbasis metakaolin, tetapi suhu 200°C merupakan pemanasan yang baik untuk mendapatkan nilai kuat tekan yang lebih tinggi dibandingkan dengan yang tidak dipanaskan setelah curing. ......Geopolymers in its application as an alternative material requires good heat resistance ability as a building material in the event of a fire or even as a refractory material. This research was conducted to determine the heat resistance of metakaolin-based geopolymer (GM) with the addition of zircon filler compared to fire-resistant cement, namely calcium aluminate cements (CAC). The samples studied were metakaolin-based geopolymer mortars with NaOH + Na2SiO3 solution, with the addition of 20% zircon sand and Ottawa sand as a comparison. After 28 days of curing, the samples underwent heat treatment variations, namely those not heated and those heated at a temperature of 200°C for 2 hours. The compressive strength test results at room temperature showed that the GM-zircon samples had higher compressive strength compared to the GM-Ottawa samples. This could be due to zircon sand acting as a filler that can enter the polysialate network and fill the voids, thereby improving the mechanical properties of the GM. However, in this study, the compressive strength of the GM-zircon samples was lower compared to the CAC-zircon samples, indicating the need for a better activator solution formula. The TG-DTA test results showed that the GM samples had 3 peaks, while the CAC samples had 2 peaks, indicating exothermic and endothermic reactions. In addition, the GM samples experienced a more significant decrease %weight due to evaporation of water compared to the CAC samples. The XRD results also showed that both the GM and CAC samples with the addition of zircon sand did not form new phases, both at room temperature and at 400°C. Thus, the addition of zircon sand did not have a significant effect on the heat resistance of metakaolin-based geopolymers. However, heating at 200°C was found to be beneficial in achieving higher compressive strength compared to samples that were not heated after curing.
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library