Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 14 dokumen yang sesuai dengan query
cover
Handoko Tirta
"Xanthorrhizol yang di isolasi dari Temulawak dapat mempertahankan pH model biofilm in vitro selama 4 jam. Diketahui KBM ekstrak Temulawak terhadap S. mutans 25%.
Tujuan : Menganalisis efek ekstrak Temulawak 25% terhadap demineralisasi email yang terpapar biofilm S.mutans.
Metode : Model biofilm diperoleh dengan mengkultur S.mutans yang sudah ditanam dalam TYS broth selama 24 jam pada 6 well ?plate yang telah dilapisi pelikel. Ekstrak Temulawak dipaparkan pada model biofilm pada berbagai durasi antara 1-48 jam. Pengukuran pH menggunakan pH universal indicator. Model biofilm juga ditumbuhkan pada permukaan sample gigi. Pemaparan Ekstrak Temulawak dilakukan pada jam ke 16-20. Uji kekerasan mikro menggunakan indenter Knoop sebelum dan sesudah perlakuan.
Hasil : Sampai dengan jam ke 4, pH model biofilm yang terpapar Ekstrak Temulawak 25% tidak mengalami penurunan pH. Tidak terlihat efek Ekstrak Temulawak terhadap kekerasan permukaan email.
Kesimpulan : Ekstrak Temulawak 25% mampu menghambat penurunan pH biofilm, tetapi tidak berpengaruh terhadap demineralisasi email.

Xanthorrhizol isolated from Java turmeric is able to maintain the pH of biofilm model in vitro for 4 hours. It was known that MBC of Java turmeric extract was 25%.
Purpose: To analyse the effect of 25% Java turmeric extract on email demineralization exposed to S. mutans biofilm.
Methods: Biofilm model was obtained by culturizing S. mutans which was cultured on TYS Broth during 24 hours on 6 well- plates which was layered by pellicle. Java turmeric Extract was added to biofilm model at various duration between 1-48 hours. pH measurement using pH universal indicator. Biofilm model was also cultured at tooth sample surface. Java turmeric extract was added at 16-20 hours. Micro hardness test was conducted using Knoop indenter before and after the intervention.
Result : After 4 hours, the pH of biofilm model which was exposed to Java turmeric 25% was not decreasing. No difference was found on the enamel micro hardness between experiment and control groups.
Conclusion : Java turmeric 25% is able to prevent reduction of biofilm pH, but does not have effect on enamel demineralization.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2012
T31042
UI - Tesis Open  Universitas Indonesia Library
cover
Annisa Akib
"SIK modifikasi resin dapat mengalami penurunan kekerasan permukaan pada pH kritis rongga mulut 5,5 yang dapat dicegah dengan pemberian ion kalsium dan fosfat. Ion tersebut bersumber dari CPP ACP. Pengaplikasian CPP ACP pada SIK modifikasi resin diketahui mampu mencegah terjadinya penurunan kekerasan permukaan SIK modifikasi resin. Saat ini telah ada penggabungan propolis pada CPP ACP yang bertujuan untuk meningkatkan sifat antibakteri tetapi diketahui penambahan propolis mengurangi pelepasan ion kalsium dan fosfat dari CPP ACP sehingga berpengaruh terhadap kemampuannya dalam melindungi SIK modifikasi resin dari penurunan kekerasan permukaan. Namun belum diketahui efek pengaplikasian CPP ACP yang ditambahkan propolis terhadap kekerasan permukaan SIK modifikasi resin.
Tujuan: penelitian ini bertujuan untuk membandingkan pengaruh aplikasi pasta CPP ACP dengan dan tanpa kombinasi propolis terhadap kekerasan permukaan semen ionomer kaca modifikasi resin.
Metode: Tiga puluh spesimen semen ionomer kaca modifikasi resin berbentuk silinder berukuran 6 x 3 mm, di polimerisasi menggunakan LED curing unit irradiansi 700 mW/cm2, selama 20 detik kemudian disimpan selama 1 hari kering dalam inkubator. Spesimen diuji kekerasan awalnnya dengan Knoop Hardness Tester (50 g selama 15 detik) dengan penjejasan 5 kali di 5 lokasi permukaan yang berbeda kemudian diambil nilai rata-ratanya untuk mempresentasikan permukaan spesimen. Spesimen dibagi menjadi tiga kelompok yaitu spesimen tanpa dan dengan pengolesan CPP ACP yang didiamkan 30 menit dan dengan pengolesan CPP ACP propolis yang didiamkan 30 menit. Seluruh spesimen direndam dalam larutan asam laktat pH 5,5 selama 24 jam dan diuji nilai kekerasan permukaan akhirnya. Data dianalisis menunggunakan uji statistik Kruskal Wallis dan uji Post Hoc Mann Whittney.
Hasil: hasil menunjukkan bahwa kekerasan awal seluruh spesimen adalah 30,68, 0,03 dan setelah diberi perlakuan kelompok A menjadi 24,96, 0,07, kelompok B menjadi 27,9, 0,01 dan kelompok C menjadi 26.5, 0,03. Pengaplikasian CPP ACP propolis pada SIK modifikasi resin menyebabkan penurunan kekerasan permukaan yang lebih besar dibandingkan dengan yang hanya diaplikasikan CPP ACP.

The surface hardness of Resin modified glass ionomer cement can be decrease at the critical pH of the oral cavity 5.5 which can be prevented by giving calcium and phosphate ions. These ions can be sourced from CPP ACP. Aplication CPP ACP is known to be able to prevent a decrease in the surface hardness of resin modified glass ionomer cement. Now there has been the addition of propolis to CPP ACP which functions as an antibacterial but it is known the further addition of propolis reduces ion calcium and phosphate release from CPP ACP which influences its capability in protecting RMGIC from further reduction of surface hardnes. However, the effect of CPP ACP application that added propolis is not yet known on resin modified glass ionomer cement.
Objective: this study aims to compare the effect of CPP ACP paste application with it and without a combination of propolis against the surface hardness of glass ionomer cement modified resin.
Methods: thirty specimens of Resin Modified Glass Ionomer Cement in cylindrical shape (6 x 3 mm), 1 day dray storage in the incubator and the specimen are polymerized for 20 seconds using a 700 mW/cm irradiance LED curing unit. The initial specimens were tested for hardness with Knoop Hardness Tester (50 g for 15 seconds) with 5 times of crushing in 5 different surface locations then the average value was taken to present the specimen surface. The specimens were divided into three groups: without CPP ACP application, CPP ACP and CPP ACP Propolis application which were allowed to stand for 30 minutes. All specimens were immersed in lactic acid pH 5.5 for 24 hours and tested for final surface hardness values. Data obtained analyzed using Kruskal Wallis dan Mann Whittney.
Results: the test showed that the initial hardness of all specimens were 30,68, 0,03 and after treatment group A becomes 24,96, 0,07, group B becomes 27,9, 0,01 and group C becomes 26.5, 0,03. There was a decrease surface hardness of the resin modified glass ionomer cement before and after immersion at all groups. The initial hardness of all specimens were 30,68, 0,03 and after treatment group A becomes 24,96, 0,07, group B becomes 27,9, 0,01 and group C becomes 26.5, 0,03. The application of CPP ACP propolis to RMGIC caused.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jesica Uli Giovani
"Semen Ionomer Kaca (SIK) konvensional dapat mengalami penurunan kekerasan permukaan pada pH 5,5 sehingga membutuhkan pemberian ion kalsium dan fosfat yang dapat ditemukan pada CPP-ACP untuk mencegah penurunan kekerasan. Penelitian terhadap CPP-ACP tengah dilakukan dengan penambahan propolis yang ditujukan untuk menambah sifat antimikroba. Berdasarkan penelitian sebelumnya diketahui bahwa penambahan propolis pada CPP-ACP menyebabkan ion kalsium dan fosfat yang dilepaskan berkurang sehingga mungkin memengaruhi kemampuannya dalam mencegah penurunan kekerasan SIK konvensional. Namun belum diketahui efek CPP-ACP apabila ditambahkan propolis pada SIK konvensional.
Tujuan: Penelitian ini bertujuan untuk membandingkan pengaruh CPP-ACP dengan dan tanpa kombinasi propolis terhadap kekerasan permukaan SIK konvensional.
Metode: Tiga puluh spesimen SIK konvensional berbentuk silinder dengan diameter 6mm dan tebal 3 mm dibuat dan diletakkan dalam inkubator selama 24 jam. Spesimen lalu dilakukan pengujian kekerasan awal menggunakan Vickers Micro Hardness Tester dengan indenter Knoop, setiap spesimen diberikan indentasi dengan beban 50 g selama 15 detik sebanyak 5 kali diposisi berbeda pada permukaan dan diambil rata-rata untuk merepresentasikan seluruh permukaannya. Spesimen kemudian dibagi menjadi tiga kelompok (masing-masing 10 spesimen), yaitu yang tanpa diaplikasikan CPP-ACP, yang diaplikasikan CPP-ACP, dan yang diaplikasikan CPP-ACP propolis. Spesimen yang diaplikasikan CPP-ACP atau CPP-ACP propolis didiamkan selama 30 menit di dalam inkubator. Spesimen kemudian direndam dalam asam laktat pH 5,5 selama 24 jam lalu diuji kekerasan akhirnya.
Hasil: Kekerasan awal didapat sebesar 74,51±1,82KHNdan setelah perendaman pada kelompok tanpa diaplikasikan CPP-ACP menjadi 40,82±0,71KHN, kelompok yang diaplikasikan CPP-ACP menjadi 57,94±1,40KHN dan kelompok yang diaplikasikan CPP-ACP propolis menjadi 52,01±1,23KHN. Terdapat penurunan bermakna (p<0,05) antara kekerasan sebelum dan setelah perendaman di semua kelompok dan terdapat perbedaan bermakna (p<0,05) pada kekerasan antar kelompok dengan uji One-way ANOVA dan post hoc Tamhane.
Kesimpulan: Pengaplikasian CPP-ACP dengan kombinasi propolis pada SIK konvensional menyebabkan penurunan kekerasan permukaan lebih besar dibandingkan dengan yang hanya CPP-ACP.

Conventional glass ionomer cement (GIC) can be decreased in surface hardness at critical pH (5,5) so calcium and phosphate ions, which can be found in CPP-ACP, are needed to prevent it. Research about CPP-ACP were being developed by adding propolis to increase antimicrobial properties. However, study before stated that the addition of propolis into CPP-ACP could be decreasing ions release so probably decreasing its ability to prevent conventional GICs surface hardness reduction. But the effect of CPP-ACP if were added with propolis toward conventional GIC not yet known.
Aims: This study aims to compare the effect of CPP-ACP with and without propolis on conventional GICs surface hardness.
Methods: Thirty specimens of conventional GIC, 6mm in diameter and 3 mm in thick were prepared and saved in incubator for 24 hours. Specimens initial surface hardness were measured by Vickers Micro Hardness Tester with Knoop indenter. Each specimen was indented using 50 g weigh in 15 seconds for five times on different spot to represent all the surface hardness of the specimen and the mean value was calculated. Specimens then divided into three groups (each group contain 10 specimens), which were without CPP-ACP, applicated with CPP-ACP and applicated with CPP-ACP propolis. CPP-ACP or CPP-ACP propolis were applicated to conventional GIC and kept for 30 minutes in incubator. After that, specimens were immersed in lactic acid pH 5,5 for 24 hours and the final surface hardness were tested. The surface hardness values then were analyzed using One Way Anova and Post Hoc Tamhane test.
Result: Initial surface hardness value was 74,51±1,82KHN, and decreased after immersion. The final surface hardness value become 40,82±0, 71KHN on without CPP-ACP group, 57,94±1, 40KHN on with CPP-ACP group, and 52,01±1, 23KHN on with CPP-ACP propolis group. There were statistically significant (p<0.05) in specimens hardness reduction between before and after immersion in all groups and in hardness differences between groups after immersion.
Conclusion: Application of CPP-ACP combined with propolis on conventional GIC caused greater surface hardness reduction compared to CPP-ACP without propolis.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Novira Mutia Safitri
"Pendahuluan: Adanya lesi white spot setelah perawatan ortodonti cekat akan menyebabkan permukaan email semakin kasar. Peningkatan kekasaran permukaan email memudahkan penempelan plak oleh bakteri. Oleh karena itu diperlukan penatalaksanaan lesi white spot dengan teknik abrasi mikro, aplikasi Fluor dan aplikasi CPP-ACP.
Tujuan: Penelitian ini bertujuan untuk menganalisis perbedaan kekasaran permukaan email lesi white spot sebelum dan setelah perlakuan teknik abrasi mikro, abrasi mikro disertai aplikasi Fluor dan abarasi mikro disertai aplikasi CPP-ACP dan menganalisis perbedaan perubahan kekasaran permukaan email diantara ketiga kelompok.
Bahan dan Cara: Penelitian menggunakan 42 buah gigi premolar satu atas yang telah diekstraksi sebagai spesimen penelitian, kemudian spesimen direndam selama 96 jam dalam larutan demineralisasi pH 4, 37 C untuk membentuk lesi white spot buatan. Sampel dibagi secara acak menjadi 3 kelompok perlakuan n= 14 , yaitu A teknik abrasi mikro; B teknik abrasi mikro disertai aplikasi pasta 10 CPP-ACP dan C teknik abrasi mikro disertai aplikasi gel 1.23 APF. Pengukuran kekasaran permukaan email menggunakan alat Surface Roughness Tester merk Mitutoyo SJ-301 dalam dua waktu yaitu sebelum perlakuan dan setelah perlakuan.
Hasil: Hasil penelitian menunjukkan bahwa terdapat perbedaan kekasaran permukaan email lesi white spot secara bermakna pada seluruh kelompok sebelum dan sesudah perlakuan. Ada perbedaan perubahan kekasaran permukaan email secara bermakna antar kelompok setelah perlakuan, namun yang menunjukkan perbedaan perubahan paling besar adalah kelompok teknik abrasi mikro disertai aplikasi CPP-ACP.
Kesimpulan: Metode penatalaksanaan lesi white spot dengan teknik abrasi mikro disertai aplikasi CPP-ACP merupakan metode yang paling efektif menurunkan kekasaran permukaan email dibandingkan kedua metode lainnya.

Introduction The presence of white spot lesions after fixed orthodontic treatment will lead to increase of enamel surface roughness. The increase of enamel surface roughness accomodate the addition of plaque by bacteria. Therefore we need the management of white spot lesions.
Aim: The aim of this study was to analyze the surface roughness of white spot lesion enamel after micro abrasion technique, a combination micro abrasion technique and CPP ACP application and a combination micro abrasion technique and Fluor application.
Materials and Methods: Artificially induced white spot lesion in enamel surface of forty two extracted upper premolar one for fixed orthodontic treatment were randomly assigned into one of three treatment groups n 14 , which were A micro abrasion technique B A combination of the micro abrasion technique and CPP ACP application C a combination of the micro abrasion technique and Fluor application. Mitutoyo SJ 301 was used to measure difference before and after treatment and also the surface roughness changes compared in three groups after treatment.
Results: According to the results of this study, there was a significant difference in surface roughness of white spot lesion enamel after treatment in all groups p 0.05 . There was a significant difference in the result of surface roughness changes compared with three methods of white spot lesion treatment.
Conclusions: A combination of the micro abrasion technique and CPP ACP application significantly reduces the enamel surface roughness greater than micro abrasion alone and a combination of the micro abrasion technique and Fluor application.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2017
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Dwi Retno Anggraeny
"Semen ionomer kaca (SIK) pit and fissure sealantsdapat mengalamipenurunan kekerasan permukaan ketika terpapar kondisi pH kritis (5.5). Hal tersebut dapat dicegah dengan pemberian ion kalsium fosfat yang dapat ditemukan pada CPP-ACP. Saat ini, CPP-ACP dapat dikombinasikan dengan propolis yang bertujuan untuk meningkatkansifat antibakteri, tetapi penambahanpropolis diketahui mengurangi pelepasan ion kalsium dan fosfat dari CPP-ACP. Akan tetapi, belum diketahui efek pengaplikasian CPP-ACPyang dikombinasikan denganpropolis terhadap kekerasan permukaan SIK pit and fissuresealants.
Tujuan: Penelitian ini bertujuan untuk membandingkan pengaruh aplikasi CPP-ACP dengan dan tanpa kombinasi propolis terhadap kekerasan permukaan SIKpit and fissure sealantssetelah perendaman dalam asam laktat pH 5.5.
Metode:Tiga puluh spesimenSIK pit and fissure sealantsdibuat dalam bentuk silinder dengan diameter 6 mm dan tinggi 3 mm, kemudian dibiarkan dalam inkubator selama 24 jam. Spesimen diuji kekerasan permukaan awalnya, lalu spesimen dibagi menjadi tiga kelompok, yaitu tanpa CPP-ACP,diaplikasikan CPP-ACP, dan diaplikasikan CPP-ACP propolis. Spesimen yang diaplikasikanCPP-ACP atau CPP-ACP propolis didiamkan selama 30 menit di dalam inkubator. Masing-masing spesimen direndam dalam asam laktat pH 5.5 selama 24 jam. Setelah itu, dilakukankembali uji kekerasan permukaan akhir. Uji kekerasan permukaan dilakukan dengan menggunakan Vickers Hardness Tester dengan indenter Knoopyang dijejaskan dengan beban 50g selama 15 detik 5 kali di 5 lokasi yang berbeda pada permukaan spesimen, kemudiandiambil nilai rata-ratanya untuk merepresentasikan seluruh permukaan spesimen. Data dianalisa menggunakan One-Way ANOVAdan Post Hoc Bonferroni.
Hasil: Kekerasan awal seluruh spesimenadalah84.87±0.85 KHN dan setelah diberi perlakuan, kekerasan permukaankelompok spesimen yang tanpa CPP-ACP menjadi 37.56±0.70 KHN, spesimen diaplikasikan CPP-ACP menjadi 72.32±0.69 KHN, dan spesimen diaplikasikan CPP-ACP propolis menjadi 55.12±1.30 KHN. Hasil penelitian menunjukkan terjadi penurunan kekerasan permukaan yangbermakna (p<0.05) pada kekerasan permukaan sebelum dan setelah perendaman pada setiap kelompok dan terdapat perbedaan bermakna (p<0.05) pada kekerasan permukaan antar kelompok.
Kesimpulan: Pengaplikasian CPP-ACP propolis pada SIK pit and fissure sealantsmenyebabkan penurunan kekerasan yang lebih besar dibandingkan dengan yang hanya diaplikasikan CPP-ACP.

Glass ionomer cement (GIC) pit and fissure sealants may have decreasedthesurface hardnessat critical pH (5.5)conditionand can beprevented by giving calcium phosphate ionswhich werefound in CPP-ACP.Recently, CPP-ACP can be combined with propolis which aims to improve antibacterial properties, butprevious study showed that the addition of propolis canreduce the release of calcium and phosphate ions from CPP-ACP. However, the effect of CPP-ACP propolis is not yet known on the surface hardness of GIC pit and fissure sealants.
Objectives: To comparethe effect of CPP ACP paste with and without propolis towards surface hardness of GIC pit and fissure sealants when immersed in lactic acid pH 5.5.
Methods: A total of 30 cylindrical specimens of GIC pit and fissure sealants were set in incubator for 24hours. Initial surface hardness value of each specimen was measured, then specimens weredivided into three groups; without CPP-ACP, applied with CPP-ACP, and applied with CPP-ACP propolis. Specimens applied with CPP-ACP or CPP-ACP propolis werekeptfor30minutes in the incubator. Specimens were immersed in lactic acid pH 5.5 for 24 hours and their surface hardness were re-measured. Surface hardnesswere determined using Vickers hardness Tester with Knoopindenter with 50 g weight for 15 seconds 5 timesondifferent points and the mean value were measured to represent the entire surface of specimen. Statistical analysis of the results was then performed usingOne Way ANOVA and Post Hoc BonferroniTest.
Results: Initial surface hardness of all specimens resulted in 84.87±0.85KHN.After immersion, specimens without CPP-ACP resulted in 37.56±0.70 KHN, specimensappliedwith CPP-ACPresulted in 72.32±0.69 KHN, and specimensappliedwith CPP-ACP propolisresulted in 55.12±1.30 KHN. The results showed significantdecrease in surface hardness (p<0.05) before and after immersionin each group and there were significant differences (p<0.05) on surface hardness betweengroups.
Conclusions:Application of CPP-ACP propolis towards GIC pit and fissure sealants caused greater reduction in surface hardness compared with application of CPP-ACP.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aurelia Yasniyati Ndalon
"Resin komposit bulk-fill adalah jenis resin komposit yang dapat menghemat waktu pengerjaan dan mengurangi kemungkinan jebakan udara karena mempunyai kemampuan untuk berpolimerasi secara memadai dengan depth of cure 4-5 mm. Ketahanan resin komposit terhadap keausan dipengaruhi oleh beberapa faktor salah satunya adalah kekerasan permukaan. pH asam adalah salah satu faktor yang bisa menyebabkan terjadinya penurunan tingkat kekerasan resin komposit. Obat kumur herbal adalah salah satu produk dengan variasi pH yang banyak digunakan untuk mengatasi masalah pada rongga mulut. Tujuan: Penelitian ini bertujuan untuk mengetahui pengaruh pH beberapa jenis obat kumur herbal terhadap kekerasan permukaan resin komposit bulk-fill Metode: Tiga puluh dua (32) spesimen resin komposti bulk-fill (Tetric® N-Ceram bulk-fill shade IVA dengan diameter 6 mm dan tinggi 3 mm) dibagi menjadi 4 kelompok dengan masing-masing kelompok terdiri dari 8 spesimen. Masing-masing spesimen akan dilakukan perendaman pada suhu 370 C selama 6 jam dalam 20 ml larutan yang terdiri dari akuades (pH 6,78), pepsodent herbal natural (pH 6,54), total care lemon herbs (pH 5,04), listerine gum care jahe herbal (pH 4,07). Sebelum dan sesudah perendaman masing-masing spesimen akan diukur nilai kekerasan permukaan dengan Knoop Hardness Tester (HMV-G®: G21 Series Micro Vickers Hardness Tester Shimadzu) Hasil: Terjadi penurunan kekerasan permukaan resin komposit Tetric® N-Ceram Bulk-fill setelah direndam dalam semua larutan. Nilai rata-rata kekerasan permukaan sebelum perendaman untuk semua spesimen adalah 37,89±0,50 KHN. Sedangkan nilai rata-rata kekerasan permukaan sesudah perendaman pada masing-masing kelompok adalah akuades (pH 6,78) sebagai kelompok kontrol 36,36±1,01 KHN, obat kumur pepsodent 34,31±0,65 KHN, total care lemon herbs (pH 5,04) 32,41±0,61 KHN, obat kumur listerine gum care jahe herbal 30,68±0,43 KHN. Berdasarkan hasil uji One-Way ANOVA dan uji Post Hoc Post Hoc Tamhane menunjukkan bahwa terdapat perbedaan bermakna (p < 0,05) antar semua kelompok perendaman. Kesimpulan: Terdapat penurunan nilai kekerasan permukaan resin komposit bulk-fill setelah dilakukan peredaman dalam larutan akuades, pepsodent herbal natural, total care lemon herbs, listerine gum care jahe herbal mouthwash selama 6 jam dan penurunan nilai kekerasan permukaan tertinggi terjadi kelompok listerine gum care jahe herbal dan penurunan kekerasan terendah terjadi pada kelompok akuades.

Background: Bulk-fill resin composite is a type of resin composite that not only allows minimal processing time but also minimal possibility of air trapping due to its ability to properly polymerize with the depth of cure 4-5 mm. There are several factors that affect the wear resistance of resin composite, one of which is surface hardness which is highly impacted by the acidity level (pH). Herbal mouthwash is an example of product that offers wide variety of pH content used for oral cavity treatment. Aims: This study aims to determine the impact of pH level of several herbal mouthwash on the surface hardness of bulk-fill resin composite. Methods: There were thirty two (32) bulk fill resin composite specimens prepared (Tetric® N-Ceram bulk-fill shade IVA with a diameter of 6 mm and a thick of 3 mm), which then equally divided into four different groups, based on the solution used for soaking. The first group used 20ml of distilled water that has pH of 6.78. The second group was soaked in 20 ml of pepsodent herbal natural mouthwash solution with slightly lower pH content of 6.52. Group three had 20 ml of total care lemon herbs with even lower pH content of 5.04. Lastly, the last group (group four) used 20ml listerine gum care herbal ginger solution that has the least pH content of 4.07. The soaking process for each specimen was done at temperature of 37 celcius for approximately six hours. The measurement of the specimens’ surface hardness was performed using Knoop Hardness Tester (HMV-G®: G21 Series Micro Vickers Hardness Tester Shimadzu), prior to and after the soaking process. Results: There was a decrease in the surface hardness of the Tetric® N-Ceram bulk-fill composite resin after being immersed in all solutions. The average value of surface hardness before immersion for all specimens was 37.89±0.50 KHN. While the average value of surface hardness after soaking in each group was distilled water (pH 6.78) as the control group 36.36±1.01 KHN, Pepsodent mouthwash 34.31±0.65 KHN, total care lemon herbs (pH 5.04) 32.41±0.61 KHN, mouthwash listerine gum care herbal ginger 30.68±0.43 KHN. Based on the One-Way ANOVA test and the Post Hoc Tamhane test, it can be inferred that there is a significant difference (p<0.05) among the immersion groups. Conclusion: There was a decrease in the surface hardness value of the Bulk-fill composite resin after soaking in a solution of distilled water, natural herbal pepsodent, total care lemon herbs, listerine gum care ginger herbal mouthwash for 6 hours and the highest decrease in surface hardness value occurred in the listerine gum care herbal ginger group and the lowest decrease in hardness occurred in the distilled water group."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lathifa Khaerani
"Latar Belakang: Resin komposit bulk-fill dapat merestorasi kavitas dengan kedalaman 4-5 mm dalam sekali penyinaran sehingga dapat mempersingkat prosedur restorasi, Polimerisasi resin komposit dapat dipengaruhi oleh suhu, termasuk suhu penyimpanan dan preheating resin komposit. Polimerisasi yang adekuat diperlukan untuk mendapatkan kekerasan permukaan yang optimal. Tujuan: Mengetahui pengaruh suhu penyimpanan dan preheating terhadap kekerasan permukaan resin komposit bulk-fill. Metode: Tiga puluh spesimen Tetric® N-Ceram Bulk-Fill shade IVA (diameter 6 mm dan tebal 3 mm) dibuat dari 3 kelompok perlakuan yaitu resin komposit yang disimpan pada suhu ruangan 23±1°C selama 24 jam (kontrol), lemari pendingin 4±1°C selama 24 jam, dan preheating 39°C selama 10 menit. Spesimen dipolimerisasi menggunakan light curing unit LED berintensitas 1100 mW/cm2 selama 10 detik dan disimpan di inkubator pada suhu 37°C selama 24 jam. Uji kekerasan menggunakan Knoop Microhardness Tester. Analisis data dengan uji statistik One-Way ANOVA dan Post Hoc Bonferroni. Hasil: Kekerasan permukaan antara kelompok perlakuan suhu penyimpanan dan preheating menunjukkan terdapat perbedaan bermakna secara statistik (p<0,05). Kesimpulan: Kekerasan permukaan resin komposit bulk-fill pada suhu penyimpanan di lemari pendingin 4±1˚C lebih rendah dibandingkan di ruangan 23±1˚C, sedangkan kekerasan permukaan resin komposit bulk-fill dengan suhu preheating 39˚C lebih tinggi dibandingkan penyimpanan di ruangan 23±1˚C.

Background: Bulk-fill composite resin could be used in 4-5 mm thickness for each photo-polymerization so that it can shorten the restoration procedure time. Polymerization of composite resin can be affected by temperature, including composite resin’s storage temperature and preheating. Adequate polymerization needed to achieve optimal surface hardness or composite resin. Objective: To evaluate the influence of storage temperature and preheating on surface hardness of Bulk-fill Composite Resin. Methods: Thirty specimens of Tetric® N-Ceram Bulk-Fill shade IVA (6 mm of diameter and 3 mm of thickness) were made from 3 groups according to storage temperature and preheating of the composite: (1) room temperature 23±1°C for 24 hours (control), (2) refrigerator temperature 4±1°C for 24 hours, and (3) preheating 39°C for 10 minutes. Each specimen was polymerized using LED Curing Unit for 10 minutes with 1100 mW/cm2 intensity, then immersed in 5 ml of aquadest and kept in 37°C incubator for 24 hours. urface hardness was measured using Knoop Microhardness Tester at the top surfaces. Data were statistically analyzed using One-Way ANOVA and Post Hoc Bonferroni test. Result: There was a statistically significant difference (p0,05) of surface hardness value between all test groups. Conclusion: Surface hardness of bulk-fill composite resin at refrigerator temperature 4±1˚C are lower than room temperature 23±1˚C, while surface hardness of bulk-fill composite resin with preheating 39°C are higher than room temperature 23±1˚C."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rigita Ayu Dyah Prawestiningrum
"Penelitian ini bertujuan untuk mengetahui pengaruh perendaman larutan nanas terhadap kekerasan permukaan resin komposit bulk-fill. Enam puluh spesimen resin komposit Tetric®N-Ceram Bulk-Fill shadeIVB berdiameter 6 mm dan tebal 3 mm dibagi menjadi dua kelompok perlakuan, yaitu perendaman dengan aquades sebagai kontrol dan larutan nanas pH: 3,8±0,1(n= 30). Sebelumnya seluruh kelompok direndam terlebih dahulu dalam aquades selama 24 jam dalam inkubator bersuhu 37oC sebagai baseline. Kemudian masing-masing kelompok tadi akan direndam kembali dalam larutan selama 1 hari, 3 hari dan 7 hari (n= 10). Kekerasan permukaan diukur menggunakan HMV-G SeriesVickers Micro Hardness Tester Shimadzu®dengan indenter Knoop. Setiap spesimen akan diindentasi dengan beban sebesar 50 gf, sebanyak 5 kali indentasi. Hasil penelitian menunjukkan bahwa terdapat perbedaan bermakna (p<0,05)antara perendaman 1 hari, 3 hari dan 7 hari pada kelompok perendaman larutan nanas dengan uji One-way ANOVA. Disimpulkan bahwa larutan nanas dapat menurunkan kekerasan permukaan resin komposit bulk-fill.

This study aims to determine effect of pineapple solution immersion on surface hardness of bulk-fill composite resin. Sixty specimens of Tetric®N-Ceram Bulk-Fill composite resin shade IVB, 6 mm in diameter and 3 mm thick were divided into two groups, with immersion in aquades as a control and pineapple solutionpH: 3,8±0,1 (n= 30). Before immersion, all specimens were immersed in aquades for 24 hours and were saved in incubator at 37oC as a baseline.Each group of immersions would be divided into three groups, with immersion for 1 day, 3 days and 7 days (n= 10). The surface hardness was measured using HMV-G Series Vickers Micro Hardness Tester Shimadzu®with Knoop Indenter. Each specimen was indented with load of 50 gf for 5 times. The results showed that there were statistically significant differences (p <0.05) between pineapple solution immersion for 1 day, 3 days and 7 days with One-way ANOVA test. It can be concluded that pineapple solution can reduce surface hardness of bulk-fill composite resin."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jung, Jumin
"Latar belakang: Light Curing Unit (LCU) LED metode pulsa iradiansi 900 mW/cm2 telah dikembangkan untuk menghasilkan suhu pada ruang pulpa lebih rendah dibandingkan metode kontinu akibat polimerisasi resin komposit Nanofill pada durasi penyinaran 20 detik. Tujuan: menganalisis pengaruh durasi dan metode penyinaran pulsa terhadap kekerasan permukaan dan Depth of Cure resin komposit Nanofill. Metode: Spesimen resin komposit Nanofill (diameter 6 mm dan tebal 2 mm) disinar dengan LCU LED metode pulsa beriradiansi 900 mW/cm2 selama 5, 10, dan 20 detik, lalu direndam di dalam 5 ml akuades (37˚C 24 jam). Setiap spesimen diuji dengan Knoop Microhardness Tester sebanyak 5 kali pada permukaan atas dan bawah dan dihitung depth of cure. Hasil: Terjadi peningkatan kekerasan permukaan yang disinar dengan LCU metode penyinaran pulsa dan kontinu selama 5 hingga 20 detik yaitu 45,9±1,6/26,4±1,6 KHN hingga 68,8±1,8/57,4±1,6 KHN, dan 46,8±1,6/28,2±1,5 KHN hingga 69,3±1,2/57,8±1,1 KHN. Terdapat perbedaan bermakna (p<0,05) pada kekerasan permukaan di kelompok durasi penyinaran dengan uji One-way Anova dan post hoc Tamhane. Pada nilai depth of cure resin komposit Nanofill yang disinar antara kedua metode penyinaran tidak terdapat perbedaan bermakna (p>0,05) secara statistik. Kesimpulan: Resin komposit Nanofill yang disinar pada durasi lebih lama menunjukkan kekerasaan permukaan atas maupun bawah lebih tinggi dibandingkan dengan durasi lebih pendek. Demikian pula, depth of cure pada durasi lebih lama menunjukkan nilai lebih tinggi. Penyinaran metode pulsa iradiansi 900 mW/cm2 dan kontinu iradiansi 900 mW/cm2 menunjukkan kekerasan permukaan dan depth of cure yang sama."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alamsyah Putra
"Latar belakang : Resin komposit bulkfill merupakan resin terbaru yang dapat direstorasi dengan kedalaman 4-5 mm dalam sekali penyinaran. Polimerisasi dipengaruhi oleh durasi penyinaran dan besaran irradiansi lightcuring untuk mendapatkan kekerasan permukaan dan depth of cure yang optimal. Tujuan: Penelitian ini bertujuan untuk mengetahui perbedaan nilai kekerasan resin komposit dan depth of cure resin komposit Tetric® N- Ceram bulk-fill yang disinari lightcure dengan durasi 5 detik, 10 detik dan 15 detik. Metode Penelitian: Dalam penelitian ini digunakan 24 spesimen resin komposit Tetric® N-Ceram bulk-fill berbentuk silinder dengan ukuran diameter 6 mm dan tebal 4 mm. Selembar mylar strip diletakkan diatas permukaan resin komposit sebelum dilakukan proses curing. Polimerisasi dilakukan menggunakan Light Curing Unit (LED DBA iLed) selama 5 detik, 10 detik dan 15 detik dengan irradiansi 1100 mW/cm2. Setelah polimerisasi, spesimen direndam dalam akuades pada suhu 37oC selama 24 jam. Spesimen dibagi menjadi tiga kelompok (n=8) yaitu; kelompok resin komposit dengan penyinaran 5 detik, penyinaran 10 detik dan penyinaran 15 detik. Spesimen diuji menggunakan HMV-G Series Micro Vickers Hardness Tester (Shimadzu, Jepang) dengan beban 100 gram selama 10 detik untuk mendapatkan nilai kekerasan. Data dianalisis dengan uji statistik Kruskall Wallis dan Post-Hoc Mann Whitney. Hasil Penelitian: Hasil uji statistik menunjukkan kenaikan bermakna nilai kekerasan permukaan dan depth of cure pada resin komposit Tetric® N-Ceram bulk-fill. Nilai kekerasan dan depth of cure tertinggi terlihat pada resin komposit Tetric® N-Ceram bulk-fill pada kelompok penyinaran 15 detik, yaitu sebesar 41,61 ± 1,25 KHN dan 72,71 ± 1,88. Kesimpulan: Disimpulkan bahwa semakin bertambah durasi penyinaran lightcure yang disinari, semakin bertambah nilai kekerasan permukaan dan depth of cure resin komposit Tetric® N-Ceram bulk-fill.

Background : Bulkfill composite resin is the newest resin that can be restored to a depth of 4-5 mm in one step. Polymerization is determined by the irradiation time and the amount of light curing irradiance to obtain optimal microhardness and depth of cure. Objective: The aim of this study was to determine the difference in the value of the microhardness of the composite resin and the depth of cure of the Tetric® N-Ceram bulk- fill composite resin irradiated by lightcure with a duration of 5 seconds, 10 seconds and 15 seconds. Method: Twenty four specimens of Tetric® N-Ceram bulk-fill Composite Resin were used in this study. All materials were prepared into disk-shaped specimens of 6 mm in diameter and 4 mm in thickness. A piece of mylar strip was placed on the top of the specimens just before the polymerization.. Polymerization was carried out using a Light Curing Unit (LED DBA iLed) for 5 seconds, 10 seconds and 15 seconds with an irradiance of 1100 mW/cm2. After polymerization, specimens were immersed in 37 aquadest solution for 24 hours. Specimens were divided into three groups (n=8) that is; composite resin group with 5 seconds of irradiation, 10 seconds of irradiation and 15 seconds of irradiation. Specimens were tested with HMV-G Series Micro Vickers Hardness Tester (Shimadzu, Jepang) with 100 gram indentation in 10 seconds. Data were analyzed using Kruskall Wallis and Post-Hoc Mann Whitney to assess the significant differences among groups Result: The results of statistical tests showed a significant increase in the value of microharhardness and depth of cure on Tetric® N-Ceram bulk- fill composite resin. The highest microhardness and depth of cure values were seen in the Tetric® N-Ceram bulk-fill composite resin in the 15 second irradiation group, namely 41.61 ± 1.25 KHN and 72.71 ± 1.88. Conclusion: It was concluded that the longer the duration of irradiation of the irradiated lightcure, the higher the microhardness value and depth of cure of the Tetric® N-Ceram bulk-fill composite resin."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2   >>