Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 4 dokumen yang sesuai dengan query
cover
cover
Dwinugroho Putro Utomo
Abstrak :
Microgrid dituntut untuk dapat mendeteksi kondisi islanding dalam waktu yang cepat untuk dapat mencegah memburuknya gangguan. Dan salah satu metode deteksinya yaitu deteksi pasif yang dapat mendeteksi secara cepat dan sistemnya sederhana tapi mengorbankan akurasi deteksinya. Sehingga digunakan machine learning pada metode pasif untuk meningkatkan akurasi deteksinya. Metode deteksi yang diajukan ini membaca sinyal tegangan yang kemudian diolah dengan Variational Mode Decomposition (VMD) untuk menjadi fitur masukkan machine learning Long Short Term Memory (LSTM) yang digunakan untuk mendeteksi keadaan Islanding. Simulasi metode deteksi ini yang dilakukan pada model microgrid PV-baterai menghasilkan deteksi dengan akurasi sebesar 97.6% dengan waktu deteksi sekitar 0.04 detik ......Microgrid is required to be able to detect islanding conditions as fast as possible to prevent worsening the situation. And one of the detection methods is passive detection which can detect quickly and simple but have low detection accuracy and a non-detection zone (NDZ). Hence, machine learning is used in the passive method to improve the detection accuracy and remove NDZ. The proposed detection method reads grid voltage signal which is then processed with Variational Mode Decomposition (VMD) to become an input feature for Long Short-Term Memory (LSTM) machine learning which is used to detect the Islanding state. The simulation of this detection method on the PV-battery microgrid model resulted in detection with an accuracy of 97.6%, a detection time about 0.04 seconds and almost zero NDZ.
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Natanael Kristian
Abstrak :
Tren perkembangan sumber energi baru terbarukan atau EBT yang terus meningkat dan didukung serta cadangan energi fosil Indonesia yang semakin menipis membuat permintaan terhadap pembangkit listrik EBT semakin tinggi. RUPTL PLN serta regulasi PLN terbaru terus mendukung perkembangan PLTS, salah satunya adalah PLTS Atap dengan memperbolehkan ekspor hingga 65% dari nilai energi yang dihasilkan. Namun, sistem PLTS Atap yang umum dipakai yaitu grid-tie, tidak dapat digunakan saat PLN padam. Maka dari itu, penelitian ini bertujuan untuk membuat sistem proteksi tersebut, melihat pengaruh undervoltage dan overvoltage, variasi waktu tunda, dan meninjau apakah sistem sesuai dengan regulasi-regulasi yang ditetapkan oleh PLN. Rancang bangun sistem proteksi sendiri terdiri dari beberapa komponen utama yaitu Arduino, modul relay elektromagnetis, dan modul sensor tegangan ZMPT101B. Penelitian dilakukan dengan membangun prototipe dan menguji prototipe berdasarkan variasi-variasi pada parameter tegangan dan waktu tunda yang ditentukan. Hasil yang didapatkan menunjukkan waktu pemutusan kurang dari 0.16 detik pada V<50% serta V>120%, kurang dari 2 detik pada 50% ≤ V <88%, dan operasi kontinyu pada 88% ≤ V ≤ 110%. Dari hasil yang ditunjukkan, rancang bangun ini memiliki potensi yang besar sebagai sistem proteksi alternatif karena harganya yang sangat ekonomis dan kemampuan Arduino guna mengintegrasikan smart grid. ......The latest trend development of renewable energy that keep increasing and getting more support along with Indonesia’s backup fossil energy that keep decreasing have increased the demand for renewable power plants. RUPTL PLN as well as PLN’s latest regulation keep supporting the development of solar power plant, one of which is solar home system regulation by allowing export of up to 65% from the power generated. However, the most common used solar home system which is grid-tie, is unusable when there is a blackout. Therefore, this purpose of this research is to create protection system such as that, observe the effect of undervoltage and overvoltage, variation of delay, and review if said system fulfill PLN’s regulations. The design of the protection system is composed of several major device which comprise of Arduino, electromagnet relay module, and ZMPT101B voltage sensor module. The research is conducted by building the prototype and testing said prototype with variations from voltage and delay parameter. The result shows that at V<50% as well as V>120% trip time are lower than 0.16 second, at 50% ≤ V <88% trip time are lower than second, and continuous operation at 88% ≤ V ≤ 110%. From the result showed, this design has a great potention to be an alternative protection system for solar home system for its economic price and the ability of Arduino to integrate the system into smart grid.
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adinda Nindya Wardhanie
Abstrak :
Terjadinya gangguan 4 kabel secara bersamaan pada sistem Jawa-Bali dapat menyebabkan turunnya frekuensi dikarenakan hilangnya suplai daya sebesar 339,9 MW. Penurunan ini dapat berakibat buruk pada kinerja sistem sehingga dibutuhkan pengembalian frekuensi ke kondisi normal. Pengembalian frekuensi ke nilai awal dapat dicapai dengan pelepasan beban dengan skema secara bertahap. Dalam studi ini dilakukan simulasi pelepasan beban secara trial and error menggunakan software DIgSILENT PowerFactory sampai tercapai kondisi ideal yaitu frekuensi mendekati 50 Hz. Dari simulasi yang dilakukan didapat bahwa kondisi terbaik dicapai oleh skema pelepasan beban tiga tahap dengan perbandingan beban pertahapnya bernilai seimbang yaitu pada Skema II, dengan maksimum frekuensi tercapai adalah 49,94 Hz dalam waktu 9,068 detik.
The breakdown of 4 wires simultaneously in the Java - Bali system can cause a decline in the frequency due to the loss of 339,9 MW energy supply. This decrease can adversely impact the performance of the system thus frequency needed to be returned to normal conditions . Returns of the frequency of the initial value can be achieved by a load shedding scheme with gradual step. In this study, load shedding simulation is done by trial and error using DIgSILENT PowerFactory software to achieve ideal frequency conditions, which is approximately 50 Hz. From the simulation, we found that the best condition is achieved by using Scheme II, a 3 steps load shedding scheme with similar ratio per step, which reach a maximum frequency of 49,94 Hz and is reached within 9,068 seconds.
Depok: Fakultas Teknik Universitas Indonesia, 2016
S65431
UI - Skripsi Membership  Universitas Indonesia Library