Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 4 dokumen yang sesuai dengan query
cover
Dunn, P.D.
Oxford: Pergamon Press, 1982
621.402 5 DUN h
Buku Teks  Universitas Indonesia Library
cover
Reay, D.A.
"Heat pipes, takes a highly practical approach to the design and selection of heat pipes. This new edition has been revised to include new information on the underlying theory of heat pipes and heat transfer, and features fully updated applications, new data sections, and updated chapters on design and electronics cooling. The book is a useful reference for those with experience and an accessible introduction for those approaching the topic for the first time."
Oxford, UK: Butterworth-Heinemann, 2014
e20427040
eBooks  Universitas Indonesia Library
cover
Kristofer Haliansyah
"Seluruh kegiatan manusia tak lepas akan kebutuhannya atas energi. Pemanfaatan sumber energi tak terbarukan secara berlebihan dan meningkatnya kebutuhan manusia akan energi membuat beberapa isu global menjadi marak diperbincangkan. Salah satu pemanfaatan energi terbarukan adalah dengan menggunakan energi matahari melalui solar water heater. Solar water heater terbagi menjadi dua komponen utama, yaitu solar kolektor dan tangki penyimpanan. Pada paper ini akan dibahas pengujian melalui prototipe tabung vakum solar kolektor berbasis heat pipe ganda sebagai instrumen yang melakukan ekstrkasi panas. Panas dari matahari akan disimulasikan dengan menggunakan lampu halogen dengan daya 150 Watt.
Prototipe solar kolektor yang digunakan didesain dengan memanfaatkan satu buah sirip yang menghubungkan kedua buah heat pipe. Pengujian dilakukan dengan menggunakan dinding isolatif dengan menggunakan styrofoam dan tripleks untuk mengurangi pengaruh perpindahan panas dari lingkungan akibat perbedaan temperatur. Variasi yang dilakukan dan diamati pada eksperimen ini adalah pengaruh panjang wick terhadap performa heat pipe dan solar kolektor dimana wick akan mempengaruhi dinamika fluida kerja dan resistansi thermal dari pada heat pipe. Melalui pengujian ini didapatkan bahwa heat pipe dengan wick yang memanjang pada adiabatic zone dan seluruh evaporating zone memiliki resistansi termal yang paling rendah dibandingkan penggunaan heat pipe dengan wick yang menutupi setengah evaporator dan tiga perempat evaporator, yaitu sebesar 0,37 K/W dengan efisiensi sistem tertinggi yaitu sebesar 34,95% sehingga memiliki performa terbaik dibandingkan yang lain.

Every human activity needs energy. The increasing number of non-renewable energy and the rising need of energy caused some global issue. It always be interesting to discuss how human being could create and improve an instrument that can extract energy from renewable energy resources which is clean and applicable. One of the instrument that can extract energy from the sun is solar water heater. Solar water heater is consist of two main component. The first component is called storage tank, and the other is called solar collector. This paper will discuss the experimental result of evacuated tube solar collector based on dual heat pipes as an heat extractor from the sun. The experiment goes with a 150 Watt halogen lamp as a simulator of the sun.
The solar collector prototype which is used in this experiment designed with a fin. A copper fin is being used to collect heat from the sun and trasfer the heat to heat pipes. Adibatic walls made from styrofoam and plywood are used in this experiment to prevent any heat transfer from the environment due temperature difference. Wick length inside heat pipe is the variation that being investigated in this research. The flow characteristic inside the heat pipe depend on the wick length, and thermal resistance of heat pipe will be changed as a result of wick length variation. The experiment result conclude that the full length wick heat pipe has the best performace with 0.37 K/W thermal resistantion and the efficiency of the system reach 34,95%. This is the highest value compared to the half length and three quarter length wick heat pipe.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S53990
UI - Skripsi Membership  Universitas Indonesia Library
cover
Irfan Zidny
"In tropical countries like Indonesia, maintaining comfortable and healthy indoor environments is a significant challenge due to high temperatures and humidity levels. This issue is particularly critical for the Fast-Moving Consumer Goods (FMCG) industry, where specific room ambient conditions are necessary to ensure product safety and quality, especially during processes like beverage filling. This research delves into integrating heat pipes into HVAC systems to improve energy efficiency in regards to ensuring clean room conditions during beverage filling processes. With hopes to align with the United Nations Sustainable Development Goals (SDGs). The research employed two-row U-shaped heat pipes with a wick structure made of sintered copper, filled with water at a 50% ratio. The U-shaped HPHE facilitates both precooling and reheating processes. The evaporator section absorbs heat from incoming air, reducing the compressor's workload. After passing through the cooling coil, the air temperature rises again due to heat release at the condenser side of the HPHE, reducing the energy needed for reheating during dehumidification. Initial characterization of the heat pipe was conducted with an inlet air temperature of 45°C and an air velocity of 1.4 m/s. Our experiments revealed a peak temperature increase of 6.4°C on the condenser side, resulting in a 20.7% reduction in relative humidity. The temperature drop on the evaporator side was 0.7°C. Maximum energy savings of 304.44 W were achieved at this inlet temperature with an air velocity of 2.2 m/s. To understand the performance under lower temperature conditions, further tests were conducted at inlet temperatures of 30°C, 35°C, and 40°C. These variations demonstrated the versatility of the U-shaped HPHE in improving dehumidification efficiency across a range of operating conditions. The highest effectiveness observed was 21.04%, showcasing the potential of U-shaped HPHEs in enhancing energy efficiency in HVAC systems.

Di negara-negara tropis seperti Indonesia, menjaga lingkungan dalam ruangan yang nyaman dan sehat merupakan tantangan besar karena suhu tinggi dan tingkat kelembapan yang tinggi. Masalah ini sangat penting bagi industri barang konsumen cepat saji (Fast-Moving Consumer Goods atau FMCG), di mana kondisi ruangan tertentu diperlukan untuk memastikan keamanan dan kualitas produk, terutama selama proses pengisian minuman. Penelitian ini mendalami integrasi pipa panas ke dalam sistem HVAC untuk meningkatkan efisiensi energi dalam menjaga kondisi ruangan bersih selama proses pengisian minuman. Dengan harapan untuk selaras dengan Tujuan Pembangunan Berkelanjutan Perserikatan Bangsa-Bangsa (SDGs). Studi ini menggunakan pipa panas berbentuk U dengan struktur sumbu yang terbuat dari tembaga sinter, diisi dengan air pada rasio 50%. HPHE berbentuk U ini memfasilitasi proses pendinginan awal dan pemanasan ulang. Bagian evaporator menyerap panas dari udara yang masuk, mengurangi beban kerja kompresor. Setelah melewati koil pendingin, suhu udara naik kembali karena pelepasan panas di sisi kondensor HPHE, mengurangi energi yang dibutuhkan untuk pemanasan ulang selama dehumidifikasi. Karakterisasi awal pipa panas dilakukan dengan suhu udara masuk 45°C dan kecepatan udara 1,4 m/s. Eksperimen ini mengungkapkan peningkatan suhu puncak sebesar 6,4°C di sisi kondensor, menghasilkan pengurangan kelembapan relatif sebesar 20,7%. Penurunan suhu di sisi evaporator adalah 0,7°C. Penghematan energi maksimum sebesar 304,44 W dicapai pada suhu udara masuk ini dengan kecepatan udara 2,2 m/s. Untuk memahami kinerja pada kondisi suhu yang lebih rendah, pengujian lebih lanjut dilakukan pada suhu udara masuk 30°C, 35°C, dan 40°C. Variasi ini menunjukkan fleksibilitas HPHE berbentuk U dalam meningkatkan efisiensi dehumidifikasi di berbagai kondisi operasi. Efektivitas tertinggi yang diamati adalah 21,04%, menunjukkan potensi HPHE berbentuk U dalam meningkatkan efisiensi energi di sistem HVAC."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library