Sentot Novianto
Abstrak :
An investigation into flow boiling void fraction was conducted to observe its characteristics and to develop a new correlation of void fraction based on the separated model. The study used a natural refrigerant of R-290, flowed in a horizontal tube of 7.6 mm inner diameter under experimental conditions of 3.7 to 9.6oC saturation temperature, 10 to 25 kW/m2 heat flux, and 185 to 445 kg/m2s mass flux. The void fraction, calculated by the present experimental data, was used for comparison with 31 existing correlations, including model types as follows: homogeneous, slip ratio, K?h correlation, drift flux, and a model based on the Lockhart-Martinelli correlation (Xtt). A new void fraction correlation, as a function of liquid and vapor Reynolds numbers, was proposed, based on the data. The measured pressure drop was compared with some pressure drop correlations that use the newly developed void fraction combination. The best prediction was shown by the homogeneous model.
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:2 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Sentot Novianto
Abstrak :
Saat ini penggunaan refrigran yang ramah lingkungan menjadi kebutuhan manusia. Penelitian tentang refrigran pengganti, salah satunya R-290 menjadi kebutuhan untuk mengetahui karakteristik didih alir. Penelitian penurunan tekanan, dan pertukaran kalor R-290 diharapkan dapat menggantikan posisi R-22 sebagai refrigran alami. Dalam percobaan aliran didih R-290 dan R-22 sebagai pembanding dilakukan dalam pipa konvensional berdiameter 7,6 mm. Variasi fluks kalor dari 5,9 kW/m2 sampai 25,04 kW/m2, fluks massa dari 282 kg/m2.s sampai 630 kg/m2.s, dan temperature saturasi dari -0,42°C sampai 11,97°C untuk R-22, sedangkan variasi 9,89 kW/m2 sampai 25,04 kW/m2, fluks massa dari 185 kg/m2.s sampai 445 kg/m2.s dan temperature saturasi dari 3,73°C sampai 9,56°C untuk R-290. Hasil yang diperoleh adalah penurunan tekanan dipengaruhi oleh fluks massa, fluks kalor dan temperature saturasi, dimana R-22 mempunyai penurunan tekanan lebih rendah dari R-290. Sedangkan untuk perpindahan kalor dipengaruhi oleh fluks kalor dan temperature saturasi, sedangkan fluks massa tidak menunjukkan perubahan nilai perpindahan kalor baik untuk R-22 dan R- 290. R-290 mempunyai nilai perpindahan kalor lebih besar dari R-22. Persamaan prediksi paling baik untuk penurunan tekanan R-22 oleh Mishima-Habiki (1996), sedangkan R-290 oleh Homogenous (1960). Persamaan prediksi paling baik untuk perpindahan kalor R-22 oleh Shah (1982), sedangkan R-290 oleh Kwang II Choi (2009). ...... To day the use of environmentally friendly refrigran into human needs. Research on refrigran substitutes, one of which R-290 being the need to know the characteristics of flow boiling. Study pressure drop and heat exchange R-290 is expected to replace the R-22 as a natural refrigran. In the experiment the flow boiling of R-290 and R-22 as the comparison is done in a conventional pipe diameter of 7.6 mm. The variation of the heat flux of 5.9 kW/m2 to 25.04 kW/m2, mass fluxes from 282 to 630 kg/m2.s kg/m2.s, and the saturation temperature of - 0.42°C to 11.97°C to R-22, while the variation of 9.89 kW/m2 to 25.04 kW/m2, mass fluxes from 185 to 445 kg/m2.s kg/m2.s and saturation temperature of 3.73°C to 9.56°C to R-290. The result is a pressure drop is influenced by the mass flux, heat flux and saturation temperature, where the R-22 has a lower pressure drop than R-290. As for the heat transfer is affected by the heat flux and saturation temperature, while the mass flux showed no change in the value of a good heat transfer for R-22 and R-290. R-290 has a value greater heat transfer than R-22. The best prediction equation for the pressure drop of R-22 by Mishima-Habiki (1996), while the R-290 by homogenous (1960). The best prediction equation for the heat transfer of R-22 by Shah (1982), while the R-290 by Kwang II Choi (2009).
Depok: Fakultas Teknik Universitas Indonesia, 2014
T41876
UI - Tesis Membership  Universitas Indonesia Library
cover
Ulfi Khabibah
Abstrak :
Penggunaan refrigeran HFCs dan hydrocarbon mulai banyak digunakan untuk menggantikan refrigeran HCFCs, karena memiliki nilai Ozon Depletion Potential (ODP) 0.0. Salah satu contohnya adalah R-290 (propane) yang termasuk golongan refrigeran hydrocarbon dengan struktur molekul C3H8. Pada penelitian ini, perpindahan kalor pada proses didih alir terjadi dalam pipa kanal mini berdiameter dalam 7.6 mm dan panjang 1.07 m. Untuk menentukan nilai koefisien perpindahan kalor, penelitian ini dilakukan dengan variasi fluks massa dari 200 kg/m2.s sampai 400 kg/m2.s, fluks kalor dari 5 kW/m2 sampai 20 kW/m2 , dan temperatur saturasi dari 5 oC sampai 15 oC. Koefisien perpindahan kalor pada R-290 dipengaruhi oleh fluks kalor, fluks massa, dan temperatur saturasi. Semakin tinggi fluks kalor, fluks massa dan temperatur saturasi maka koefisien perpindahan kalor akan meningkat. Pada perbandingan koefisien perpindahan kalor dengan korelasi dari beberapa peneliti sebelumnya, korelasi dari Shah (1982) memiliki nilai deviasi rata-rata paling kecil, yaitu 32.20%. Korelasi baru didapatkan dari pengembangan faktor F dengan metode regresi dan diperoleh nilai daviasi rata-rata yang lebih kecil, yaitu 22.46%.
The use of HCFCs refrigerants are gradually being replaced by HFCs and hydrocarbons refrigerants that has 0.0 ODP (Ozon Depletion Potential). One of which is R-290 (propane), which is a hydrocarbon refrigerant with C3H8 molecular structure. In this research, the flow boiling heat transfer occurs inside small tube with diameter of 7.6 mm and length of 1.07 m. In order to determine the value of heat transfer coefficient, the experiment were carried out for mass fluxes ranging from 200 kg/m2s to 400 kg/m2s, heat fluxes ranging from 5 kW/m2 to 20 kW/m2, and saturation temperatures from 5 oC to 15 oC. The study analyzed the heat transfer, through the local heat transfer coefficient along the flow, under the variation of these different parameters. The boiling heat transfer coefficient of R-290 is influenced by heat flux, mass flux, and saturation temperature. In comparison to previous boiling heat transfer correlations, the correlation of Shah (1982) best fitted the experimental result with the mean deviation of 32.20%. The new correlation for boiling heat transfer coefficient was developed by modification of F factor with regression method. The new correlation has smaller mean deviation in comparison with the experimental result, that is 22.46%.
Depok: Fakultas Teknik Universitas Indonesia, 2014
T43346
UI - Tesis Membership  Universitas Indonesia Library
cover
Edo Widi Virgian
Abstrak :
Kebutuhan terhadap refrigeran alternatif untuk sistem refrigerasi semakin meningkat. Salah satu refrigerant alternatif yang umum digunakan terutama dalam keperluan sistem tata udara pemukiman adalah propana. Propana atau R290 memiliki keunggulan karena selain mudah didapatkan, juga memiliki sifat properti termodinamika dan perpindahan kalor yang cukup baik antara lain viskositas dinamik serta rapat massa jenis yang kecil dan stabil sehingga memiliki kemampuan penyerapan kalor yang baik meskipun membutuhkan perhatian terutama di dalam penannganan potensi bahaya ledakan. Salah satu metode yang umum digunakan di dalam analisis performa sistem refrigerasi adalah aliran dua fasa. Perhitungan korelasi perhitungan tekanan dilakukan dengan menggunakan basis data yang berasal dari penelitian Pamitran, et. al (2011) yang terdiri dari fluks kalor q = 5-20 kW/m2, G = 50-180 kg/m2. s; temperatur saturasi 0-11 oC, dan fraksi massa atau kualitas uap 0-1. Hasil menunjukkan bahwa fluks laju aliran massa, fluks kalor, dan bilangan Reynolds fasa campuran berbanding lurus terhadap penurunan tekanan aktual, persamaan korelasi Friedel (1979) memberikan nilai yang lebih akurat untuk memprediksi penurunan tekanan dengan nilai MAE (Mean Absolute Error) sebesar 59,12 % dan regim aliran yang terbentuk adalah regim aliran plug (kantong udara), slug, dan transition menuju wavy-annular menurut peta pola aliran Zhuang, et.al (2016). ......The need for alternative refrigerants for refrigeration system is increasing. One of the alternative refrigerants that commonly used, especially in residential air conditioning systems, is propane. Propane or R290 has the advantage because in addition to being easy to obtain, it also has good thermodynamic properties and heat transfer, including small and stable dynamic viscosity and density so that it has good heat absorption ability although it requires attention, especially in potential explosion hazards. One of the methods that commonly used in refrigeration system performance analysis is two-phase flow. Calculation of the correlation of pressure drop is carried out using a database derived from Pamitran, et. al (2011) which consists of parameters range such as heat flux q = 5-20 kW/m2, G = 50-180 kg/m2. S, saturation temperature 0-11 oC, and mass fraction or vapor quality 0-1. The results show that the mass flow rate flux and heat flux are directly proportional to the actual pressure drop with a greater effect of mass flow rate flux and Friedel's (1979) correlation equation provides a more accurate value for predicting pressure drop with MAE (Mean Absolute Error) value of 59,12 %. On the flow pattern map of Zhuang, et.al (2016) a plug-slug and transition flow condition to wavy-annular is formed.
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Fajri Octadiansyah Umar
Abstrak :
Berbagai percobaan pressure drop aliran dua fasa pada pipa minichannel telah dilakukan. Selain mendapatkan data eksperimental, banyak peneliti juga membandingkan data eksperimen mereka, bahkan menambahkan data peneliti lain ke korelasi yang ada. Tujuan pada eksperimen ini untuk mengenal karakteristik pressure drop pada aliran dua fasa dengan menggunakan pipa horizontal minichannel dan refrijeran propane (R290), eksperimen ini menggunakan 18 korelasi yang ada dimana terbagi menjadi dua metode untuk mencari nilai pressure drop, yaitu metode separated dan homogeneous. Kondisi eksperimen ini menggunakan pipa horizontal dengan diameter dalam 3 mm, untuk mass flux divariasikan dari 50 hingga 180 kg/m2s, sedangkan untuk heat flux divariasikan 5 hingga 20 kW/m2, temperature saturasi divariasikan 10 hingga 11 oC dan vapor quality 0 hingga 1. Hasil pada eksperimen ini berhasil mendapatkan korelasi terbaik dalam memprediksikan data eksperimen, yaitu korelasi milik Sun dan Mishima (2008) dengan mean absolute error sebesar 27,64 % ......Various experiments on the pressure drop of the two-phase flow boiling in the mini channel tube has been carried out. In addition to obtaining data on experimental pressure drop, many researchers have also compared their experimental data, and even added the data of other researchers to existing correlations. The purpose of this experiment is to identify the characteristics of the pressure drop in a two-phase flow using a horizontal minichannel pipe and a propane refrigerant (R290), this experiment uses 18 existing correlations which are divided into two experiments using a horizontal pipe with an inner diameter of 3 mm, for mass flux. varied from 50 to 180 kg / m2s, while for heat flux it was varied from 5 to 20 kW/m2, saturation temperature was varied from 10 to 11 oC and vapor quality was 0 to 1. This experiment managed to get the best correlation in predicting experimental data,the correlation of Sun and Mishima (2008) with a mean absolute error of 27.64%
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library