Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 6 dokumen yang sesuai dengan query
cover
Abstrak :
The purpose of this research is to find supporting capacity of the industry to the field work of SMK Negeri 27 Jakarta students and also to provide a clear picture of how SMK Negeri Jakarta has performed the apprentice program. This research was conducted at SMK 27 Jakarta Industrial partners Data collecting was conducted in July-November 2007 from 20 industrial partners who were randomly selected. Executives of these industrial partners were interviewed and the result indicated that :(1) Majority of industrial partners executives were in favor of the apprentice program (2) Their support materialized in : making apprentice program a permanent one in their company, conducting apprentice program in 5 batches each year to accomodate more students, actively inform schools of such apprentice opportunities (3) apprentice program in those industrial partners have been performing well as indicated by: student placement by their expertise, supervisory and guidance from assigned officer where the apprentice took place, allowing school to monitor the implementation of industrial apprenticeship and allowing apprentice students to work by themselves, evaluation and certificates issued by company at the of apprenticeship.
JUPEKEB
Artikel Jurnal  Universitas Indonesia Library
cover
Riward DH
Abstrak :
Perencanaan struktur gedung tahan gempa tidak terlepas dari faktor daktilitas yang dimiliki oleh struktur tersebut. Penelitian tesis ini adalah tentang evaluasi daktilitas pada stuktur ganda. Struktur ganda merupakan gabungan dari dua subsistem yang berkerja secara bersama-sama, subsistem tersebut adalah frame dan shearwall, dimana masing-masing mempunyai nilai R (faktor reduksi gempa). Berdasarkan SNI 03-1726-2002, apabila kedua subsistem digabungkan menjadi sebuah sistem ganda, maka digunakan nilai R rata-rata berbobot. Tujuan tesis ini adalah untuk mengetahui nilai R yang realistis untuk digunakan, apakah nilai R terkecil, terbesar atau rata-rata berbobot, dari kedua nilai R subsistem. Dari hasil berbagai simulasi didapatkan bahwa nilai R yang paling realistis yaitu nilai R terkecil dari kedua subsistem tersebut.
Seismic design of a building structure is not separate from ductility factor of that structure. This thesis reaseach about ductility evaluation for dual system. Dual system is combination from two subsistem and working together. Those subsystems are frame and shearwall. Each subsystems have R (seismic reduction factor) value. Based on SNI 03-1726-2002, if two subsystems are merged become a dual system, then we use average value of seismic reduction factor R. Purpose of this thesis is to know realistic value of seismic reduction factor R , is use the minimum R value, maximum or average R value, from two subsystems R values. From output many simulations are got that the most of realistic R value is minimum value of seismic reduction factor R from those subsystems.
Depok: Fakultas Teknik Universitas Indonesia, 2009
T25269
UI - Tesis Open  Universitas Indonesia Library
cover
Riward DH
Abstrak :
Perencanaan struktur gedung tahan gempa tidak terlepas dari faktor daktilitas yang dimiliki oleh struktur tersebut. Penelitian tesis ini adalah tentang evaluasi daktilitas pada stuktur ganda. Struktur ganda merupakan gabungan dari dua subsistem yang berkerja secara bersama-sama, subsistem tersebut adalah frame dan shearwall, dimana masing-masing mempunyai nilai R (faktor reduksi gempa). Berdasarkan SNI 03-1726-2002, apabila kedua subsistem digabungkan menjadi sebuah sistem ganda, maka digunakan nilai R rata-rata berbobot. Tujuan tesis ini adalah untuk mengetahui nilai R yang realistis untuk digunakan, apakah nilai R terkecil, terbesar atau rata-rata berbobot, dari kedua nilai R subsistem. Dari hasil berbagai simulasi didapatkan bahwa nilai R yang paling realistis yaitu nilai R terkecil dari kedua subsistem tersebut.
Seismic design of a building structure is not separate from ductility factor of that structure. This thesis reaseach about ductility evaluation for dual system. Dual system is combination from two subsistem and working together. Those subsystems are frame and shearwall. Each subsystems have R (seismic reduction factor) value. Based on SNI 03-1726-2002, if two subsystems are merged become a dual system, then we use average value of seismic reduction factor R. Purpose of this thesis is to know realistic value of seismic reduction factor R , is use the minimum R value, maximum or average R value, from two subsystems R values. From output many simulations are got that the most of realistic R value is minimum value of seismic reduction factor R from those subsystems.
Depok: Fakultas Teknik Universitas Indonesia, 2009
T40773
UI - Tesis Open  Universitas Indonesia Library
cover
Alexandra Patricia Andriani
Abstrak :
Post-tensioned (PT) flat slab merupakan salah stau sistem struktur yang banyak digunakan di beberapa negara seperti Amerika Serikat, Australia, Afrika Selatan, Thailand, dan India. Dibanding negara lain, penggunaan PT flat slab di Indonesia masih tergolong sedikit, umumnya hanya pada basement. Hal ini dapat diakibatkan oleh struktur flat slab yang rentan terhadap pengaruh gaya lateral, khususnya di Indonesia dengan potensi gempa tinggi. Namun, penggunaan flat slab masih memungkinkan untuk digunakan di daerah dengan potensi gempa tinggi dengan menerapkan Separated Gravity Lateral Resisting System (SGLR System) yaitu desain yang memisahkan antara penahan lateral dan penahan beban gravitasi. Dalam penelitian ini, beban lateral akan dipikul oleh SRPMK dan dinding geser sedangkan flat slab hanya menahan gravtasi. Melalui penelitian ini diharapkan informasi terkait PT flat slab di Indonesia dapat bertamba. ......Post-tensioned (PT) flat slab is one of the structural systems widely used in several countries such as the United States, Australia, South Africa, Thailand, and India. Compared to other countries, the use of PT flat slab in Indonesia is still relatively small, generally only in basements. This can be caused by the flat slab structure which is vulnerable to the influence of lateral forces, especially in Indonesia with high earthquake potential. However, the use of flat slabs is still possible to be used in areas with high earthquake potential by implementing the Separated Gravity Lateral Resisting System (SGLR System), a design that separates lateral resistance and gravity load resistance. In this study, the lateral load will be resist by the special moment resisting frames and shear walls while the flat slab only resists gravity. Through this study, it is hoped that information related to PT flat slabs in Indonesia can be increased.
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Achmad Damar Al Chamid
Abstrak :
Penelitian ini membahas mengenai metode desain sistem ganda dari struktur portal - dinding geser beton bertulang akibat beban gempa dan kebutuhan tulangan yang diperlukan untuk masing-masing metode perhitungan. Dalam penentuan sistem ganda sesuai peraturan SNI 03-1726-2002, pada penelitian ini dilakukan tiga metode desain, struktur portal - dinding geser yang berinteraksi, struktur portal dengan boundary element dinding geser, dan struktur portal dengan dengan dinding geser yang di non-aktifkan. Dalam metode portal - dinding geser yang berinteraksi, struktur bangunan di desain berdasarkan analisis dinamik dan analisis statik, tetapi untuk dua metode lainnya dilakukan dengan analisis statik. Pada penelitian ini ditinjau bangunan 8 lantai pada lokasi gempa di Jakarta dengan tanah lunak dianalisis sebagai sistem ganda. Simulasi numerik menunjukkan bahwa pendekatan portal ? dinding geser saling berinteraksi dengan faktor reduksi R = 6,5 (SRPMM) menghasilkan tulangan paling besar dibandingkan dengan dua metode lainnya. ......This thesis discussed about method of design of a reinforced concrete shear wall - frame structure as dual system due to earthquake load and the requirement of rebar for each methods. In determining dual system structure based on SNI 03-1726-2002, some methods of design such as interaction of shear wall - frame structure, frame with boundary element, and frame with deactivated shear wall is considered in this thesis. In interaction of shear wall - frame structure method, building structure was designed based on dynamic and static analysis, however for two other methods static approach was employed. In this thesis an 8-story building located in Jakarta and built on soft soil was analyzed as dual system. Numerical simulations show that interaction of shear wall ? frame structure approach with reduction factor R = 6,5 (IMRF) results the biggest required rebar compared with other methods.
Depok: Fakultas Teknik Universitas Indonesia, 2012
S43568
UI - Skripsi Open  Universitas Indonesia Library
cover
Audi van Shaf
Abstrak :
Keterbatasan lahan dikota-kota besar di Indonesia menyebabkan banyak dibangunnya gedung-gedung bertingkat tinggi untuk memenuhi kebutuhan akan ruang. Namun lokasi Indonesia yang terletak pada daerah pertemuan lempengan kerak bumi menyebabkan gedung-gedung tersebut rawan terhadap gempa bumi. Dilain pihak, tentu saja tidak ekonomis apabila membangun gedung bertingkat tinggi tahan gempa dengan dimensi yang sangat besar. Oleh karena itu diperlukan suatu konsep tertentu agar bangunan kuat terhadap beban gempa kuat dan strukturnya cukup ekonomis. Jawaban atas kondisi tersebut adalah dengan mereduksi beban gempa dan membuat system struktur yang tepat. Salah satu sistem struktur yang kuat terhadap beban gempa adalah struktur gedung sistem ganda (dual system structure). Struktur sistem ganda berupa gabungan rangka dengan dinding geser yang dapat bekerja sama dalam menahan beban gempa. Penerapan lainnya, adalah dengan memanfaatkan faktor reduksi gempa (R) untuk sistem ganda, seperti tercantum dalam Standar Perencanaan Ketahanan Gempa untuk Bangunan Gedung SNI 03-1726-2002. Permasalahan yang timbul dalam menggunakan faktor reduksi gempa (R) adalah pemilihan jenis rangka, dimana terdapat Sistem Rangka Pemikul Momen Khusus (SRPMK) dan Sistem Rangka Pemikul Momen Menengah (SRPMM), serta metode penggunaannya. Metode penggunaan faktor reduksi gempa dapat secara langsung ataupun dihitung dengan motode pembobotan. Untuk itu, pada Tugas Akhir ini akan dibahas kedua hal tersebut dengan cara membuat model-model struktur sistem ganda rangka ruang dan menganalisa model-model tersebut, sehingga diperoleh rasio berat tulangan per volume beton (kg/m3 beton). Model-model struktur yang dibuat adalah struktur rangka beton bertulang dengan dinding geser kantilever pada zona gempa 3 tanah lunak (wilayah DKI Jakarta). Model-model tersebut memiliki variasi ketinggian 8 lantai, 12 lantai, 16 lantai dan 20 lantai. Dari hasil analisa, diperoleh kesimpulan bahwa desain sistem ganda dengan menggunakan metode penggunaan faktor reduksi gempa secara langsung memiliki rasio berat tulangan per volume beton (kg/m3 beton) yang lebih besar bila dibandingkan dengan metode pembobotan. Sedangkan rasio berat tulangan per volume beton (kg/m3 beton) SRPMK lebih besar dari SRPMM. ......The lack of space in large cities in Indonesia has supported the construction of tall buildings to fulfill the needs for urban space. The location of Indonesia on plate-meeting earth crust has rendered such construction to be bound to the risk of seismic disaster. In addition, it would be considered non-economic to build a tall building in a land with high risk of earthquake. Thus a certain concept is required to enable a construction of rigorous building with an economic structure. The answer to the condition is by reducing seismic load and constructing the adequate structure required. One of the robust structures against seismic load is a combination of frame using shear wall which may support the load of earthquake. Other alternative is by using seismic reduction factor (R) in dual system structure. For the dual system structure, as described in the Indonesian Building Code for Seismic Resistance Design (Standar Perencanaan Ketahanan Gempa untuk Bangunan Gedung) SNI 03-1726-2002. The problem arising due to the implementation of seismic reduction factor (R) is the selection of frame's types, whereas Special Moment Resisting Frame (SMRF) and Intermediate Moment Resisting Frame (IMRF), as well is method of implementation is used. The method of seismic reduction factor implementation may be used directly or calculated based on the weighting method. For that matter, this Final Assignment shall discuss both matters by constructing models of dual system space frame's structure and analyzing the models, which acquired a ratio of reinforced frame's weigh per volume of concrete (kg/m3 concrete). The structure's models made are reinforced frame with cantilever shear wall on 3rd seismic zone on soft soil (DKI Jakarta region). The models varied from 8, 12, 16 and 20 stories. From the analysis, the author arrive at a conclusion that dual system design using method of seismic reduction factor implementation has a direct ratio of reinforced frame weight per volume of concrete (kg/m3 concrete) which is bigger than the weighting method. While the ratio of reinforced frame's weigh per volume of concrete (kg/m3 concrete) SMRF is bigger than IMRF.
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50465
UI - Skripsi Open  Universitas Indonesia Library