Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Rio Rahmawanto
Abstrak :
Tulisan ini membahas tentang pencemaran debu batu bara di Pelabuhan Marunda Jakarta yang muncul akibat adanya pelanggaran pada aktivitas bongkar muat batu bara yang dilakukan oleh PT. Karya Citra Nusantara. Thesis statement karya akhir ini adalah aktivitas bongkar muat batu bara yang dilakukan oleh PT. KCN di Pelabuhan Marunda ini dapat disebut sebagai corporate environmental crime karena disebabkan oleh korporasi dan membawa dampak buruk terhadap lingkungan, khususnya bagi masyarakat yang terkena dampak. Tulisan ini menggunakan perspektif green criminology dalam pembahasannya. Perspektif green criminology mampu memberikan definisi kejahatan, terutama yang berkaitan dengan kerusakan lingkungan, yang lebih komprehensif. ......This paper discusses coal dust pollution at Marunda Port, Jakarta, which arose as a result of transgression in coal loading-unloading activities carried out by PT. Karya Citra Nusantara (KCN). The thesis statement in this work is that activity of loading-unloading coal carried out by PT. KCN at Marunda Port can be called corporate environmental crime because it is caused by corporations and has negative impacts on the environment, especially for the affected communities. This paper uses a green criminology perspective in its discussion. The green criminology perspective is able to provide a more comprehensive definition of crime, especially related to environmental damage.
Depok: Fakultas Ilmu Sosial dan Ilmu Politik Universitas Indonesia, 2023
TA-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Sitorus, Bobby Robson
Abstrak :
Penelitian ini berupa analisis penyebab coal dust explosion accident di PLTU X tahun 2011 yang terjadi pada tanggal 14 Desember 2011 mengakibatkan kerugian yang berupa kerusakan coal feeder dan panel instrumen boiler, dan kerugian akibat terhentinya pembangkitan energi listrik selama masa perbaikannya. Penelitian dilakukan dengan pendekatan kualitatif untuk menganalisis data primer dan data sekunder untuk menganalisis penyebab langsung, penyebab tidak langsung dan penyebab dasar. Penyebab langsung adalah interaksi bahan, alat dan proses sehingga terpenuhinya 5 kriteria dust explosion pentagon dan menciptakan ledakan. Penyebab tidak langsung terdiri dari prilaku tidak aman dan kondisi tidak aman. Prilaku tidak aman yang dilakukan adalah mengoperasikan mill saat terjadi gangguan blocking, membuka damper cold air terlalu cepat sehingga menciptakan terpenuhinya 5 kriteria coal dust explosion diakibatkan oleh pengetahuan akan resiko coal dust explosion, tidak tersedianya SOP, pengaturan mode operasi yang belum sesuai, dan kerusakan damper cold air. Sedangkan kondisi tidak aman terdiri dari gangguan blocking, kerusakan peralatan, dan desain coal feeder. Penyebab dasar adalah komunikasi yang sulit antara operator dan kontraktor EPC, ketidakjelasan mengenai tanggung jawab perbaikan, kurangnya pengalaman personel, dan tidak ada pengawasan mengenai K3 operasi. Risk assessment khusus pengoperasian mill perlu dilaksanakan untuk mendapatkan langkah-langkah pencegahan insiden coal dust explosion yang paling tepat. ......This study analyzes the causes of a coal dust explosion accident at Steam Power Plant ?X? in 2011 which occurred on December 14, 2011 caused in losses such as damage to the instrument panel coal boiler feeder, and losses due to interruption of electric energy generation during repairs. The study was conducted with a qualitative approach to analyze primary data and secondary data to analyze the direct cause, indirect cause and basic cause. The direct cause is the interaction of materials, tools and processes that fulfill 5 criteria and creating a dust explosion pentagon explosion. Indirect causes consist of unsafe actions and unsafe conditions. Unsafe action consisted of operate mill during disturbances blocking, open the damper cold air too fast, creating the five criteria of coal dust explosion caused by the knowledge of the risks of coal dust explosion, unavailability of SOP, the setting is not appropriate mode of operation, and damage damper cold air. While unsafe conditions consisted of interference blocking, damage to equipment, and design of coal feeder. The basic cause consisted of a difficult communication between the operator and EPC contractors, uncertainty regarding the repair responsibilities, lack of personnel experience, and there is no oversight of the safety operation. Risk assessment should be carried out special operation of the mill to get the preventive measures coal dust explosion incidents are most appropriate.
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2013
T35326
UI - Tesis Membership  Universitas Indonesia Library
cover
Mona Lestari
Abstrak :
Salah satu penyebab terjadinya gangguan fungsi paru yaitu pajanan debu batubara. Penelitian ini bertujuan untuk menjelaskan hubungan pajanan debu batubara dan gangguan fungsi paru pada pekerja. Metode yang digunakan desain Cross Sectional dengan sampel 72 pekerja. Gangguan fungsi paru diperoleh dari data kesehatan perusahaan. Hasil penelitian menunjukkan bahwa gangguan fungsi paru restriksi 8,3%, obstruksi 2,8%, dan kombinasi 2,8%. Analisis bivariat menunjukkan gangguan fungsi paru berhubungan dengan masa kerja (p = 0,46). Namun pajanan debu batubara, umur, dan penggunaan alat pelindung pernapasan, ada kecenderungan untuk menjadi faktor risiko terjadinya gangguan fungsi paru. ...... One of the causes of lung function disorder in health problems is coal dust exposure. This study aims to describe the relationship of coal dust exposure and lung function disorder in workers. The method used cross-sectional design with a sample of 72 workers. Lung function disorder data is obtained from the company health data. The results of this research showed that the restriction of pulmonary function disorder 8.3%, obstruction 2,8%, and a combination of restriction and obstruction 2.8%. Bivariate analysis showed lung function disorder associated with year of work experience (p=0,46). However, coal dust exposure, age, and the using of respiratory protective equipment showed there is a tendency to get risk for lung fungtion disorders.
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2014
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library