Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 7 dokumen yang sesuai dengan query
cover
Ika P. Wijaya
Abstrak :
Hemostatic disorders, which could cause (venous or arterial) thrombosis or bleeding, are often found during hospital care. Common manifestations of thrombosis arc inner vein thrombosis, cardiac infarct, stroke, or even recurrent miscarriage. In addition to hemorrhological detect, certain clinical conditions such as diabetes mellitus or hypercholesteroJemia are risk factors that also play a role in the hemostasis system. The hemostasis system depends on vascular en-dothelial conditions, platelet function (in this case platelet aggregation), coagulation function, anti-coagulation, fibrinolysis, and anti-fibrinolysis. If one of these conditions or functions is disturbed, the hemostatic system may also be disturbed.
[Place of publication not identified]: Acta Medica Indonesiana, 2002
AMIN-XXXIV-4-OktDes2002-155
Artikel Jurnal  Universitas Indonesia Library
cover
Muhammad Begawan Bestari
Jakarta: University of Indonesia. Faculty of Medicine, 2019
610 UI-IJIM 51:1 (2019)
Artikel Jurnal  Universitas Indonesia Library
cover
Gde Ngurah Irfan Bhaskara
Abstrak :

Pendahuluan: Fibrilasi atrium (FA) adalah tipe aritmia yang paling sering ditemukan. Selama berjalannya waktu, FA telah menunjukan peningkatan dalam prevalensi dan insidens. Namun angka mortalitas tersebut lebih terkait dengan komplikasinya, yaitu gagal jantung dan stroke. Untuk itu, pencegahan komplikasi FA, terutama stroke, dalam bentuk terapi antikoagulan oral (TAK), adalah sama pentingnya dengan pengobatan FA lainnya seperti kendali laju dan kendali irama. Studi ini bertujuan untuk mendapatkan karakteristik klinik pasien FA dan pola penggunaan TAK di RSCM.

Metode: Data dari rekam medis dikumpulkan dan dianalisis menggunakan aplikasi SPSS. Karakteristik klinik pasien FA akan disediakan dalam bentuk frekuensi, dan rata-rata.

Hasil: Rata-rata umur pasien FA di RSCM adalah 56.37±14.69 tahun dan distribusi jenis kelamin hampir seimbang. Pasien FA yang overweight dan obese ada 23 (45.1%) secara total. Klasifikasi FA paling sering adalah FA persistent (37.3%). Tipe FA yang paling sering ditemukan adalah FA non-valvular (64.7%). Gejala tersering ditemukan adalah sesak nafas (56.9%). Penyakit jantung coroner (PJK) adaalah komorbiditas tersering (39.2%), sedikit lebih tinggi dari hipertensi (37.3%) di populasi pasien FA di RSCM. Komplikasi FA tersering adalah gagal jantung (60.8%). Strategi kendali laju paling sering digunakan (94.1%) untuk pasien FA di RSCM. Kebanyakan pasien FA di RSCM memiliki skor CHA2DS2VASc ≥2 (82.4%). Warfarin paling sering digunakan (84.3%) sebagai TAK untuk pasien FA di RSCM.

Kesimpulan: Hasil dari studi ini memiliki perbedaan dan kesamaan dengan negara Asia lainnya dalam distribusi variabel. Pola penggunaan TAK berada diluar ekpektasi, mungkin dikarenakan harga yang mahal dalam meresepkan NOAC

 


Introduction: Atrial fibrillation (AF) is the most common type of arrythmia which has shown increasing prevalence and incidence throughout the years. However, the mortality of AF cases is related to its complication which are stroke and heart failure. Therefore, in the attempt to prevent complication of AF, particularly stroke, anticoagulant treatment, which has developed by time, is considered when encountering AF cases just as importantly as the rate control and rhythm control management of AF. This study aims to provide the clinical characteristics of patients with AF and the pattern of anticoagulant therapy in RSCM.

Methods: Data from medical records from RSCM were collected and were analyzed using SPSS, where the frequency and mean or median of the variables were explored where appropriate.

Results: The average age of AF patients in RSCM was 56.37±14.69 years old with an almost equal distribution of gender. AF patients who were overweight and obese was 23 (45.1%) in total. The most common classification of AF was persistent AF (37.3%). Non-valvular AF was the most common type of AF (64.7%). The most common symptom in the population was dyspnea (56.9%). Coronary artery disease was the most frequent comorbidity (39.2%), slightly higher than hypertension (37.3%). The most frequent complication found was heart failure (60.8%). Rate control was mostly used (94.1%). Most AF patients in RSCM had CHA2DS2VASc score ≥2 (82.4%). Vitamin K Antagonists (VKA) was mostly used (84.3%) as oral anticoagulant of choice in RSCM.

Conclusion: This study had differences and similarities with studies from other Asian countries. The pattern of oral anticoagulant treatment was commonly VKA, which is unexpected, might be due to high cost in prescribing NOAC.

 

Depok: Fakultas Kedokteran Universitas Indonesia, 2020
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lista Roro Marsudi
Abstrak :
ABSTRAK
Metformin HCl merupakan golongan biguanid yang dapat menurunkan kadar gula darah dan digunakan untuk kondisi serius, sehingga termasuk obat yang memerlukan respon pasti dan wajib uji bioekivalensi. Penelitian ini bertujuan untuk memperoleh metode tervalidasi serta mengevaluasi pengaruh perbedaan jenis antikoagulan pada analisis metformin HCl dalam plasma. Kondisi kromatografi optimum menggunakan detektor photodiode array yang dideteksi pada panjang gelombang 234 nm; kolom C18 SunfireTM 5 m, 250 x 4,6 mm ; suhu 40 C; fase gerak SDS 10 mM dan dapar fosfat 10 mM dalam air ndash; asetonitril 60:40 v/v ; pH 7,0; dan laju alir 1,0 mL/menit dengan kalsiu atorvastatin sebagai baku dalam. Ekstraksi dilakukan dengan metode pengendapan protein menggunakan plasma 300 l dan asetonitril 600 l 1:2 v/v . Metode yang diperoleh linear pada rentang konsentrasi 20,0 ndash; 5000,0 ng/mL dengan r > 0,9998. Data stabilitas dan perolehan kembali metformin HCl dalam plasma dengan antikoagulan berbeda tidak menunjukkan perbedaan yang signifikan p > 0,05; ANOVA , namun untuk rasio respon luas puncak menunjukkan perbedaan yang signifikan p < 0,05 yaitu antikoagulan sitrat dengan EDTA dan antikoagulan heparin dengan EDTA. Secara keseluruhan, metode analisis yang diperoleh memenuhi persyaratan validasi baik untuk penggunaan antikoagulan sitrat, heparin, maupun EDTA berdasarkan EMEA Bioanalytical Guideline tahun 2011.
ABSTRACT
Metformin HCl is one of biguanid medicine which decreasing glucose level in plasma and used for critical used drug, it includes drugs that require a definite response and a mandatory of bioequivalence test. The aim of this study is to validate the analytical method and evaluate the effect of anticoagulant types for analyzing metformin HCl in human plasma. Optimal analytical condition was obtained using photodiode array detector which was detected at wavelength of 234 nm C18 SunfireTM column 5 m, 250 x 4.6 mm , temperature 40 C the mobile phase contains 10 mM SDS and 10 mM phosphate buffer in water ndash acetonitrile 60 40 v v pH 7.0 flow rate was 1.0 mL min and using atorvastatin calcium as internal standard. The plasma extraction was carried out by protein precipitation method using human plasma 300 l and acetonitrile 600 l 1 2 v v . The method was linear at concentration range of 20.0 ndash 5000.0 ng mL with r 0.9998. Based on stability and recovery of metformin HCl in plasma, there was no significant difference ANOVA p 0.05 , but it showed significant difference for peak area ratio response p 0.05 between citrate with EDTA and heparin with EDTA anticoagulants. Overall, this analytical mehod fulfill the accepteance criteria of validation based on EMEA Bioanalytical Guideline 2011.
2017
S69846
UI - Skripsi Membership  Universitas Indonesia Library
cover
Usi Sukorini
Abstrak :
Akurasi pemeriksaan profil lekosit dipengaruhi beberapa faktor preanalitik diantaranya konsentrasi antiokoagulan. Antikoagulan yang paling sering dipakai pada pemeriksaan darah rutin adalah EDTA. Ketidaksesuaian perbandingan konsentrasi EDTA dengan bahan darah berefek terhadap hasil pemeriksaan darah tepi diantaranya parameter lekosit. Penelitian ini bertujuan untuk mengetahui apakah terdapat perbedaan antara hasil pemeriksaan profil lekosit pada bahan darah dengan berbagai konsentrasi antikoagulan Na2EDTA yang berbeda. Penelitian ini merupakan penelitian potong lintang. Bahan penelitian berupa 33 sampel darah vena mahasiswa Fakultas Kedokteran UGM Yogyakarta. Dua mL darah dibagi ke dalam 4 tabung Na2EDTA. Tabung pertama berisi Na2EDTA konsentrasi standar, 2 mg/dl, tabung yang lain secara berurutan berisi Na2EDTA dengan konsentrasi 4 mg/dl, 6 mg/dl, and 8 mg/dl. Sebelumnya dibuat sediaan hapus langsung dari setetes darah tanpa antikoagulan (sebagai kontrol). Darah dalam keempat tabung tersebut segera dilakukan pembuatan sediaan hapus dan diperiksa profil hematologi lekositnya menggunakan SYSMEX SE-9500 automatic analyzer. Terdapat perbedaan yang bermakna dari hitung lekosit, hitung jenis lekosit absolut dan prosentase monosit pada konsentrasi Na2EDTA yang berlebihan. Prosentase netrofil relatif meningkat dan terdapat perbedaan yang bermakna. Prosentase limfosit, eosinofil dan basofil tidak berbeda secara bermakna. Pemeriksaan morfologi lekosit menunjukkan perubahan yang bermakna berupa tepi sitoplasma yang irreguler, vakuolisasi, dan lobus nukleus yang irreguler akibat pengaruh konsentrasi Na2EDTA yang belebihan. Disimpulkan bahwa penggunaan konsentrasi Na2EDTA yang berlebihan pada preparasi spesimen darah menyebabkan perubahan profil lekosit sesuai peningkatan konsentrasinya. Konsentrasi standar tidak mempengaruhi hitung lekosit dan hitung jenis lekosit serta morfologinya, kecuali berpengaruh terhadap tepi sitoplasma yang irreguler dan lobus nukleus yang irreguler. (Med J Indones 2007; 16:168-75)
Accuracy of leukocytes profile assessment is influenced by several pre analytical factors, among others, the anticoagulant concentration. EDTA is one of the most frequently used anticoagulant in peripheral blood examination. Several references stated that inappropriate concentration of EDTA anticoagulant in blood sample may affect the result of leukocytes profile in peripheral blood examination. The aim of this study was to evaluate whether there are differences among leukocytes profile in peripheral blood examination specimens, which were prepared with excessive Na2EDTA anticoagulant in different concentration. This study was conducted in Faculty of Medicine, Gadjah Mada University. Blood samples from 30 subjects were taken using vein puncture. Two millimeters blood was divided into 4 Na2EDTA-containing tubes. Before that, one drop of blood without Na2EDTA anticoagulant was used to make blood film right after vein puncture, as control. Each tubes contained different concentration of anticoagulant. The first tube contained Na2EDTA in standard concentration 2 mg/ml; the remaining tubes contained 4 mg/ml, 6 mg/ml, and 8 mg/ml respectively. These samples were immediately examined using SYSMEX SE-9500 automatic cell counter to measure the total and differential leukocytes count; and were stained with Wright staining for morphological examination under the microscope. These procedures were done before 20 minutes of vein puncture. There were significant decrement of total leukocytes count, absolute differential leukocytes count and monocyte percentage following excessive Na2EDTA administration. Neutrophil percentage was found to be relatively increased and the difference was significant. Lymphocyte, eosinophil and basophil percentages were not significantly different. Morphological examination showed significant increment in irregular cytoplasm margin, vacoulation and irregular nuclei lobes following excessive Na2EDTA administration. It is concluded that excessive concentration of Na2EDTA used in blood specimen preparation, will lead to changes in leukocytes profile as the concentration increased. Standard Na2EDTA anticoagulant concentration did not alter any leukocytes count and morphology, except for irregular cytoplasm margin and irregular nuclei lobes. (Med J Indones 2007; 16:168-75)
Medical Journal of Indonesia, 2007
MJIN-16-3-JulySept2007-168
Artikel Jurnal  Universitas Indonesia Library
cover
Firda Zakiatun Nufus
Abstrak :
Etinil estradiol dan levonorgestrel merupakan salah satu kombinasi kontrasepsi oral gabungan dosis rendah yang banyak digunakan di masyarakat. Namun, obat ini memiliki konsentrasi yang rendah dalam plasma, sehingga dibutuhkan metode analisis yang tepat dan sensitif. Saat ingin mendapatkan plasma dari darah dibutuhkan adanya penambahan antikoagulan. Ketika melakukan studi in vitro untuk pengembangan metode dan validasi metode analisis, antikoagulan yang digunakan yaitu sitrat. Namun, antikoagulan yang umum digunakan untuk studi in vivo adalah EDTA dan heparin, sehingga perlu dilakukan validasi parsial. Penelitian ini bertujuan untuk mengevaluasi pengaruh jenis antikoagulan terhadap analisis etinil estradiol dan levonorgestrel dalam plasma menggunakan kromatografi cair kinerja ultra tinggi tandem spektrometer massa. Kondisi analisis optimal diperoleh menggunakan kolom BEH C18 1,7 m; 50 x 2,1 mm fase gerak 0,1 asam formiat dalam air - asetonitril; metode elusi gradien; laju alir 0,3 mL/menit; suhu kolom 40 C volume penyuntikkan 10,0 L waktu analisis 5 menit dan prednison sebagai baku dalam. Aliquot diperoleh dengan kombinasi metode preparasi pengendapan protein dan ekstraksi cair-cair. Metode yang diperoleh mendapatkan hasil yang linear pada rentang konsentrasi 5-500 pg/mL untuk etinil estradiol dan 100-10.000 pg/ml untuk levonorgestrel. Hasil menunjukan tidak ada perbedaan yang signifikan untuk parameter stabilitas dan recovery p > 0,05; ANOVA, namun peak area ratio menunjukkan adanya perbedaan yang signifikan p < 0,05 Kruskal Wallis untuk sitrat, heparin, dan EDTA. Secara keseluruhan, analisis dengan plasma sitrat dan heparin memberikan hasil yang lebih baik dari plasma EDTA. ......Ethinyl estradiol and levonorgestrel is one of low dose oral contraception combinations that commonly used. However, this medication is known to have low concentration in plasma therefore an appropriate and sensitive analysis to identify it, should be taken into account. In order to obtain plasma from blood, an addition of anticoagulant is needed. A research about in vitro study for method development and validation method analysis used citrate as anticoagulant. But, anticoagulants that regularly used for in vivo study are EDTA and heparin, therefore partial validation is needed. This research objective is to evaluate the different types of anticoagulant to ethinyl estradiol and levonorgestrel in plasma by using ultra performance liquid chromatography tandem mass spectrometry. Optimal analysis condition is obtained with column BEH C18 1,7 m 50 x 2,1 mm mobile phase consisting 0.1 formic acid in water ndash acetonitrile gradient elution method flow rate of 0.3 mL minute column temperature of 40 C injection volume of 10,0 L 5 minutes analysis time and prednisone as internal standard. Aliquot is resulted by combining preparation method of protein precipitation and liquid liqud extraction. There was a linear result with the range of 5 500 pg mL concentration of ethinyl estradiol and 100 10.000 pg ml concentration of levonorgestrel. There was no significant difference for stability and recovery of ethinyl estradiol and levonorgestrel in citrate, heparin, and EDTA plasma p 0.05 ANOVA, but it showed significant difference for peak area ratio p 0.05 Kruskal Wallis, between citrate, EDTA, and heparin plasma. In general, citrate and heparin plasma analysis had better result than EDTA plasma analysis.
Depok: Fakultas Farmasi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Anisa Maulidina
Abstrak :
ABSTRAK
Klopidogrel merupakan prodrug dengan onset aksi lambat yang konsentrasinya dalam plasma sangat kecil sehingga diperlukan metode analisis yang sensitif dan selektif. Pada analisis dalam plasma in-vivo seringkali digunakan jenis antikoagulan yang berbeda dengan analisis in-vitro. Perbedaan antikoagulan memungkinkan dapat mengganggu analisis sehingga diperlukan suatu evaluasi. Penelitian ini bertujuan untuk melakukan optimasi dan validasi metode analisis klopidogrel dalam plasma menggunakan kromatografi cair kinerja ultra tinggi tandem spektrometer massa. Kondisi analisis optimal diperoleh menggunakan kolom BEH C18 (1,7 µm; 100 x 2,1 mm); fase gerak asam formiat 0,1% dalam air-asam formiat 0,1% dalam asetonitril (30:70); laju alir 0,2 mL/menit; suhu kolom 35ºC; volume penyuntikkan 5,0 µL; waktu analisis 4 menit; dan irbesartan sebagai baku dalam. Aliquot diperoleh secara ekstraksi cair-cair menggunakan amonium asetat dan dietil eter. Akurasi dan presisi pada analisis plasma sitrat, heparin, dan EDTA memenuhi persyaratan dan kurva kalibrasi linear pada rentang konsentrasi 0,02-5,0 ng/mL. Stabilitas dan peak area ratio masing-masing plasma dievaluasi menggunakan ANOVA. Hasil stabilitas menunjukkan tidak terdapat perbedaan signifikan (p>0,05) sedangkan peak area ratio menunjukkan perbedaan signifikan (p<0,05) pada ketiga plasma. Secara keseluruhan, analisis dengan plasma sitrat atau heparin memberikan hasil yang lebih baik dari plasma EDTA.
ABSTRACT
Clopidogrel is a prodrug with a very slow onset and whose concentration in plasma is so small that a sensitive and selective analysis method is required. In the analysis of plasma in-vivo, different types of anticoagulants is often used, for example citrate, heparin, and EDTA. The anticoagulant difference allows it to interfere with the analysis so that an evaluation is needed. This research is aimed to the optimization and validation of clopidogrel analysis method in plasma using ultra-high performance liquid chromatography tandem mass spectrometer. The optimal analysis conditions were obtained using BEH C18 column (1,7 μm; 100 × 2,1 mm); formic acid 0,1% in water-formic acid 0,1% in acetonitrile (30:70); 0.2 mL/min flow rate; 35ºC column temperature; inject volume 5,0 μL; 4 minute of analysis time; and irbesartan as internal standard. Aliquots were obtained by liquid-liquid extraction using ammonium acetate and diethyl ether. The accuracy and precision of the analyisis of citrate, heparin, EDTA plasma met the requirements and linear calibration curve at range concentrations 0,02-5,0 ng/mL. The stability and peak area ratio of the respective plasma area responses were evaluated using ANOVA. Results on stability showed no significant differences (p>0,05) while peak area ratio showed significant differences (p<0.05). As a whole, analysis using citrate or heparin plasma produce a better result than EDTA plasma.
2017
S69340
UI - Skripsi Membership  Universitas Indonesia Library