Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 8 dokumen yang sesuai dengan query
cover
Sitorus, Paulus Pardamean Rinaldo
Abstrak :
Preparasi elektroda boron-doped diamond (BDD) termodifikasi platina (Pt) berhasil dilakukan menggunakan teknik wet seeding yang diikut oleh elektrodeposisi. Pt yang terdeposisi pada permukaan BDD dikarakterisasi menggunakan Scanning Electron Microscopy-Energy Dispersive Spectroscopy (SEM-EDS) yang menunjukkan %Pt pada permukaan BDD sebesar 1.54 %. Elektroda ini digunakan untuk sensor As3+ dan As5+ menggunakan teknik Anodic Stripping Voltammetry (ASV). Hasil deteksi As3+ yang diperoleh pada kondisi optimum pada potensial deposisi -500 mV, waktu deposisi 150 detik dan laju deteksi 200 mV/s menunjukkan bahwa linieritas tinggi (R2 = 0.9797) pada rentang konsentrasi 0 sampai 100 ppb dengan limit deteksi (LOD) sebesar 16.50 ppb, sementara hasil deteksi As5+ dengan pre-treatment menggunakan NaBH4 0.1 M pada kondisi optimum yang sama menunjukkan linieritas yang tinggi (R2 = 0.9903) pada rentang konsentrasi 0 sampai 100 ppb memiliki linearitas yang tinggi dengan LOD sebesar 8.19 ppb.
Boron-doped diamond electrode modified by platinum was successfully prepared using wet seeding technique followed by electrodeposition. Pt deposited on the surface of BDD characterized using Scanning Electron Microscopy-Energy Dispersive Spectroscopy (SEM-EDS) which shows %Pt on BDD surface are 1.54%.These modified electrode are used for As3+ and As5+ sensors using the Anodic Stripping Voltammetry (ASV) technique. As3+ and As5+ detection results obtained using the same deposition potential of -500 mV, deposition time of 150 s and detection rate of 200 mV/s, with addition of 0.1 M NaBH4 for As5+ solution, shows that the calibration in the concentration range 0 to 100 ppb has high linearity (R2 = 0.9797 and 0.9903, respectively) with LOD at 16.50 and 8.19 ppb, respectively.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
T51884
UI - Tesis Membership  Universitas Indonesia Library
cover
Yuliwarni
Abstrak :
Deteksi secara elektrokimia dari campuran larutan As3+ dan As5+ dalam larutan yang mengandung ion Au3+telah dilakukan dengan Metode Anodic Stripping Voltammetry menggunakan elektroda kerja glassy carbon. Elektroda platina digunakan sebagai elektroda pendukung, dan elektroda reference Ag/AgCl. Metode yang digunakan berdasarkan stripping oksidasi dari As0 yang terdeposit pada elektroda karbon. Kondisi optimum yang diperoleh untuk deteksi As3+ diperoleh pada potensial deposisi -500 mV, waktu deposisi 180 detik, dan scan rate 100mV/s. Sedangkan untuk mereduksi As5+ dibutuhkan potensial yang lebih besar(negatif) untuk memenuhi energi aktifasi As5+. Sehingga kondisi optimum yang digunakan untuk deteksi As5+ adalah pada potensial -1500mV, waktu deposisi 60 s, dan scan rate 200 mV/s. Dengan mengaplikasikan kedua kondisi tersebut As3+ dan As5+ dapat dibedakan dalam campuran dengan perhitungan secara matematis. Respon linier diamati untuk larutan As3+ pada daerah konsentrasi 0- 35 ppm (R2 = 0,985) , dan untuk larutan As5+ pada daerah konsentrasi 0- 250 ppm (R2 = 0,971). Batas deteksi 3,56 dan 31,05 ppm dapat dicapai untuk masing-masing As3+ dan As5+ dalam campuran larutan. Kedapatulangan yang baik diperoleh untuk stripping voltammetry dari As3+ dan As5+ dengan (n = 15) RSD sebesar 3,95 % dan 3,54 %.
Electrochemical detection of mixture solutions of As3+ and As5+ in the presence of Au3+ has been investigated by stripping voltammetry at glassy carbon electrodes. The method was performed based on stripping oxidation of As0 deposited at the electrode surface. Whereas As3+ can be deposited by simple electrochemical reduction of As3+ to As0 at -500m V (vs. Ag/AgCl), much higher potential is required to overcome the activation energy of As5+ reduction. Optimum condition for As3+ deposition observed at the potential of -500 mV, scan rate of 100 mV/s and deposition time of 180 s. On the other hand, optimum condition for As5+ deposition was achieved at the potential of -1500 mV, scan rate of 200 mV/s and deposition time of 60 s. Therefore, to differentiate As3+ and As5+ quantification in a mixture solution, both stripping voltammetry methods should be performed and calculated mathematically. Good linear responses were observed for each standard solution of As3+ and As5+. Linear calibration curve could also be achieved for a series concentrations of 50-250 ppm As5+ (r2 = 0.971) and for a series concentrations of 0?35 ppm As3+(r2 = 0.985). Detection limits of 3,56 ppm and 31,05 ppm can be achieved for As3+ and As5+ in a mixture solution, respectively. Good reproducibility was shown for stripping voltammetry of As3+ and As5+ with an RSD (n = 15) of 3,95% and 3,54%, respectively.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
T29022
UI - Tesis Open  Universitas Indonesia Library
cover
Dian Tri Lestarini
Abstrak :
Elektroda boron doped-diamond BDD termodifikasi emas Au telah berhasil dipreparasi dengan cara seeding diikuti elektrodeposisi larutan HAuCl4 pada permukaan elektroda. Teknik seeding berfungsi untuk membuat bibit benih inti emas pada permukaan elektroda BDD melalui adsorpsi fisik. Sedangkan elektrodeposisi dilakukan untuk menghomogenkan ukuran dan sebaran partikel emas di permukaan elektroda BDD. Partikel Au yang terdeposisi dipermukaan elektroda BDD dikarakterisasi menggunakan Scanning Electron Microscopy-Energy Dispersive Spectroscopy SEM-EDS dan X-Ray Photoelectron Spectroscopy XPS. Deteksi As3, As5, dan campuran As3 dan As5 dilakukan dengan teknik anodic stripping voltammetry ASV. Mula-mula dilakukan pre-treatment menggunakan NaBH4 untuk mereduksi As5 menjadi As3 untuk menurunkan potensial deposisi As3 karena deposisi As5 memerlukan potensial deposisi yang sangat negatif dan dapat menimbulkan evolusi gas hidrogen yang dapat mengganggu pengukuraan. Respon arus terhadap masing-masing larutan standar As3 dan As5 menunjukkan linearitas yang baik pada rentang konsentrasi 0,1-1 ppmdengan R2= 0,97598 untuk As3 dan range konsentrasi 0,048-0,48 ppm dengan R2= 0,98767 untuk As5 . Limit deteksi yang dihasilkan pada pengukuran As3 sebesar 0,1675 ppm, sedangkan As5 0,0574 ppm. Pengukuran pada campuran As3 dan As5 menunjukkan linearitas yang tinggi, mengindikasikan bahwa dimungkinkan untuk mengukur konsentrasi masing-masing As3 dan As5 dalam matriks campuran.
Boron doped diamond BDD electrode modified with gold particles Au has been successfully prepared by seeding followed by electrodeposition of HAuCl4 solutions at the electrode surface. The function of seeding method is to deposite gold seeds onto the electrode surface by physical adsorption. Whereas the electrodeposition was performed to homogenize the size and distribution of the particles at the BDD electrode surface. The deposited gold particles on BDD surface were characterized using Scanning Electron Microscopy Energy Dispersive Spectroscopy SEM EDS and X Ray Photoelectron Spectroscopy XPS . Detection of As3 , As5 , and mixture solutions of As3 and As5 using anodic stripping voltammetry. Initially, pretreatment used NaBH4 was performed to reduce As5 to As3 , therefore the deposition potential can be decreased. It is known that As5 required high negative deposition potential, which can cause hydrogen gas evolution which can affecting the measurements. Good linear responses for each solution were observed in range consentration of 0,1 1 ppm for As3 R2 0,97598 and range concentration of 0,048 0,48 ppm for As5 R2 0,98767. Limit of detections of 0,1675 ppm and 0,0574 ppm can be achieved for As3 and As5 , respectively. Measurements of mixture solutions of As3 and As5 showed high linearity, indicating that detection of each species of As3 and As5 can be performed in mixture As3 and As5.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sri Widayah
Abstrak :
Deteksi 5 ion logam berat secara simultan ( Zn2+, Cd2+, Pb2+, Cu2+, dan Hg2+) dilakukan dengan menggunakan metode anodic stripping voltammetry. Elektroda boron-doped diamond digunakan sebagai elektroda kerja, platina sebagai elektroda pendukung, dan Ag/AgCl sebagai elektroda pembanding. Elektrolit yang digunakan adalah 0,1 M HCl. Kondisi optimum diperoleh pada potensial deposisi -1,3V, waktu deposisi 45 detik, scan rate 0,25 V/s. Batas deteksi untuk logam Zn, Cd, Pb, Cu dan Hg masing-masing sebesar 7,42 ppm, 1,48 ppm, 1,48 ppm, 0,74 ppm, dan 0,42 ppm. Kedapatan ulangan yang baik ditunjukkan melalui pengukuran berulang ( 20 kali berturut-turut) dengan nilai RSD sebesar 3,77%, 3,72%, 2,72%, 2,66%, dan 2,59%. masing-masing untuk logam Zn, Cd, Pb, Cu, dan Hg.
Simultaneous of 5 heavy metal ions, including Zn2+, Cd2+, Pb2+, Cu2+, and Hg2+ using anodic stripping voltammetry method was examined boron-doped diamond was utilized as working electrode, whereas platinum and Ag/AgCl were used as counter and reference electrodes respectively. A solution of 0.1 M HCl was used as the electrolyte. Optimum condition was obtained at the deposition potential of -1.3 V, deposition time of 45 seconds,and scan rate of 0.25 mV/s. Limits of detection of 7.42 ppm, 1.48 ppm, 1.48 ppm, 0.74 ppm and 0.42 ppm could be achieved for Zn, Cd, Pb, Cu, and Hg ions, respectively. Good reproducibility was shown with RSD values of 3.77%, 3.72%, 2.72%, 2.66%, and 2.59%, respectively for Zn, Cd, Pb, Cu, and Hg ions (n=20).
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
T29065
UI - Tesis Open  Universitas Indonesia Library
cover
Tri Yuliani
Abstrak :
Sintesis nanopartikel Ni OH 2 Ni OH 2NP telah berhasil dilakukan menggunakan metode pengendapan kompleks dengan keadaan hidrotermal. Ni OH 2NP dikarakterisasi menggunakan Spektrofotometer UV-Visible, Fourier Transform InfraRed FTIR , X-Ray Diffraction XRD , dan Transmission Electron Microscopy TEM . Metode Anodic Stripping Voltammetry ASV menggunakan elektroda Boron-doped Diamond BDD digunakan untuk penentuan konsentrasi Ni OH 2NP secara elektrokimia. Kondisi optimum yang diperoleh dari hasil penelitian ini adalah potensial deposisi -600 mV, waktu deposisi 90 sekon, scanrate 100 mV/s pada larutan HClO4 pH 1. Kurva kalibrasi menunjukkan bahwa ASV Na OH 2NP linier pada rentang konsenstrasi 5-25 ?M dengan limit deteksi LOD 0,481 ?M. Ni OH 2NP kemudian dikonjugasikan dengan antibodi melamin yang telah dipurifikasi Ni OH 2NP-Ab dan dikarakterisasi dengan spektrofotometer UV-Visible, FTIR, zeta potensial, dan TEM. Ni OH 2NP-Ab kemudian digunakan sebagai pengenal dalam strip test immunokromatografi untuk mendeteksi melamin dengan asumsi konsentrasi melamin berbanding lurus dengan Ni OH 2NP-Ab. Pengujian strip test immunokromatografi sebagai perangkat sensor untuk deteksi melamin secara kuantitatif dilakukan dengan metode ASV menggunakan elektroda BDD dengan kondisi seperti pada pengujian Ni OH 2NP. Strip test yang difabrikasi berhasil mendeteksi melamin secara linier R2 = 0,9605 pada rentang konsentrasi 25 ndash; 250 ppm dengan LOD 53,90 ppm.
The synthesis of Ni OH 2 nanoparticles Ni OH 2NPs has been successfully performed using hydrothermal complexation precipitation method. Ni OH 2NPs were characterized by UV Visible Spectrophotometer, Fourier Transform InfraRed FTIR , X Ray Diffraction XRD , and Transmission Electron Microscopy TEM . Anodic Stripping Voltammetry ASV method at Boron doped Diamond BDD electrode was employed to determine the concentration of Ni OH 2NPs electrochemically. The optimum electrochemical conditions were obtained at the deposition potential of 600 mV, the deposition time of 90 seconds with a scanrate of 100 mV s in HClO4 pH 1 solution. Linear calibration curve showed that the ASV of Ni OH 2NP was linear in the concentration range of 5 25 M with limit of detection LOD of 0.481 M. The Ni OH 2NPs was then conjugated with purified melamine antibodies Ni OH 2NPs Ab and characterized by UV Visible spectrophotometers, FTIR, zeta potential, and TEM. The Ni OH 2NPs Ab was employed as the sensing in immunochromatographic strip test for the detection of melamine with assumption that the melamine concentration will be proportional with Ni OH 2NPs. The quantitative determination was determined by using the ASV method with BDD, which was previously optimized. The strip test can succesfully detect melamine linearly R2 0.9605 in the concentration range of 25 ndash 250 ppm with LOD of 53.90 ppm.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S69227
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rania Umar
Abstrak :
Deteksi adanya As(III) dan As(V) dapat dilakukan dengan metode anodic stripping voltammetry. Elektroda pembanding berupa Ag/AgCl, elektroda pendukung berupa kawat platina, dan elektroda kerja yang digunakan merupakan elektroda glassy carbon dan screen printed electrode termodifikasi nanopartikel emas. Modifikasi kedua elektroda ini dengan nanopartikel emas dilakukan melalui teknik self-assembly menggunakan NH4OH sebagai aktivator. Nanopartikel emas dibuat dengan cara mereduksi HAuCl4 yang telah mengandung sitrat menggunakan pereduksi NaBH4. Kehadiran sitrat berguna untuk menstabilkan ukuran nanopartikel emas yang terbentuk. Karakterisasi dengan PSA menunjukkan ukuran nanopartikel emas sekitar 8-11 nm. Pada penelitian ini telah dilakukan modifikasi elektroda glassy carbon dan screen printed electrode dengan nanopartikel emas serta dilakukan pengujian terhadap larutan As(III) dan As(V). Hasil pengukuran larutan As(III) dan As(V) menggunakan screen printed electrode termodifikasi nanopartikel emas (SPE-AuNP) belum menunjukkan adanya puncak arus oksidasi. Sebaliknya, pengukuran menggunakan elektroda glassy carbon termodifikasi nanopartikel emas (GC-AuNP) memperlihatkan adanya puncak arus oksidasi. Respon arus terhadap As(III) pada elektroda GC-AuNP menunjukkan linearitas yang baik (r2=0,996) pada rentang konsentrasi 5-80 μM. Demikian juga untuk As(V) pada rentang konsentrasi 10-100 μM (r2=0,995). Hal ini menunjukkan bahwa elektroda GC-AuNP dapat digunakan sebagai elektroda kerja menggantikan elektroda Au bare. ...... Detection of arsenic in the form of As(III) and As(V) can be done by anodic stripping voltammetry method. The reference electrode used is Ag/AgCl, with platinum counter electrode, and as a working electrode glassy carbon and screen printed electrodes modified with gold nanoparticle were used. Modification of both working electrode was conducted through self-assembly technique in which gold nanoparticle is attached to the surface of the electrode activated by NH4OH. Gold nanoparticle was synthesized by reduction of HAuCl4 using NaBH4 in the presence of citrate. Citrate is used to prevent aggregation of gold nanoparticles. PSA characterization indicates that the size of gold nanoparticles are 8-11 nm. In this study, we investigate the possibility of modified glassy carbon electrode with gold nanoparticle to analyze As(III) and As(V). The determination of As(III) and As(V) using gold nanoparticle-modified screen printed electrode (SPE-AuNP) did not show the current oxidation peak. On the other hand, the gold nanoparticle-modified glassy carbon electrode (GC-AuNP) show current oxidation peak when used to analyze As(III) and As(V). Current response for the concentration of As(III) on GC-AuNP electrode gives linear response in the range of 5-80 μM (r2=0,996) whereas for As(V) in the range 10-100 μM (r2=0,995). This indicates that GC-AuNP electrode can replace the Au bare as a working electrode.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S1825
UI - Skripsi Open  Universitas Indonesia Library
cover
Ivandini Tribidasari Anggraningrum
Abstrak :
Modifikasi elektroda karbon, glassy carbon (GC) dan boron-doped diamond (BDD), menggunakan nanopartikel emas (AuNP) dilakukan dengan menggunakan teknik self-assembly. Teknik ini dipilih berdasarkan interaksi elektrostatik antara AuNP yang terperangkap ion sitrat dengan gugus amina yang dimodifikasikan pada BDD dan GC. Material yang diperoleh, AuNP-GC dan AuNP-BDD, kemudian digunakan sebagai elektroda pendeteksi As 3+ menggunakan teknik anodic stripping voltammetry (ASV). Anodic stripping voltammograms dari kedua elektroda menunjukkan puncak potensial oksidasi As °pada ~0.21 V (vs. Ag/AgCl) pada kondisi optimum potensial deposisi -500 mV, waktu deposisi 180 s, dan scan rate 100 mV/s. AuNP-BDD memiliki daerah pengukuran yang lebih luas (0-20 mM) dan limit deteksi yang lebih rendah (0.39 μ M atau 4.64 ppb), sedangkan AuNP-GC linier pada daerah konsentrasi 0-10 mM dengan limit deteksi 0.14 μ M (13.12 ppb). Keberulangan yang baik ditunjukkan dengan RSDs (n=20) 2.93% pada AuNP-BDD dan 4.54% pada AUNP-BDD. Meskipun demikian penurunan yang lebih banyak pada pengukuran 6 hari berturut-turut ditemukan pada AuNP-BDD (~20.1%) daripada pada AuNP-GC (~2.8%).
Modification of carbon, including boron-doped diamond (BDD) and glassy carbon (GC), using gold nanoparticle (AuNP) was developed by self-assembly technique. This technique is based on electrostatic interaction between citrate-capped AuNP to amine terminal groups after surface modification of BDD and GC. The fabricated materials, AuNP-BDD and AuNP-GC, were then utilized as electrodes for As 3+ detection using anodic stripping voltammetry (ASV) technique. Anodic stripping voltammograms of both Au NP-BDD and AuNP-GC electrodes showed similar peak potentials of As ° oxidation at ~0.21 V (vs. Ag/AgCl) in optimum conditions of -500 mV, 180 s, and 100 mV/s for deposition potential, deposition time, and scan rate, respectively. AuNP-BDD shows better performances in the case of wide linear concentration range (0-20 mM) and low limit of detection (0.39μM or 4.64 ppb), whereas those of AuNP-GC were linear in the concentration range of 0-10mM with a detection limit of 0.14μ M (13.12 ppb). Excellent reproducibility was shown with RSDs (n=20) of 2.93% and 4.54% at AuNP-BDD and AuNP-GC, respectively. However, decreasing of current responses in 6-concecutive days was found more at AuNP-BDD (~20.1%) than that at AuNP-GC (~2.8%).
Depok: Direktorat Riset dan Pengabdian Masyarakat UI; Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
J-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
Adha Masfufa
Abstrak :
Paper Electroanalytical Devices (PeAD) merupakan salah satu perangkat sensor kimia yang mulai banyak dikembangkan karena luasnya bidang aplikasi, salah satunya adalah untuk mendeteksi logam berat. Prinsip kerja dari PeAD yaitu dengan mengukur konsentrasi logam dari hasil reaksi reduksi dan oksidasi menggunakan metode potensiometri. Pada penelitian ini PeAD dikembangkan dengan adanya elektrodeposisi logam Bismut secara in situ pada elektroda, dengan menggunakan voltametri pelucutan anodik gelombang persegi (SWASV), logam Bismut dideposisi dengan membetuk film lapis tipis Bi pada permukaan elektroda dan dilakukan pemindaian dengan mikroskop elektron. Logam Bismut digunakan sebagai modifikator elektroda karena memiliki kapasitas untuk membentuk paduan dengan logam berat, seperti Pb dan Cd, selain itu juga karena sifatnya yang kurang beracun dan memiliki jendela potensial negatif yang besar sehingga proses pembentukan ikatan dengan logam dapat terjadi. Pengujian variasi pH, variasi potensial deposisi, dan variasi konsentrasi penambahan Bismut, dilakukan untuk mendapatkan hasil pengujian yang optimum, dan diperoleh kondisi optimum pada pH larutan 4,6 dengan potensial deposisi -1,2 V, dan penamabahan 1 mg/L Bismut. PeAD. Yang berhasil di fabrikasi kemudian dikarakterisasi dengan menggunakan Scanning Electron Micsroscopy (SEM), Fourier-Transform Infra Red (FTIR), Contact Angle Meter (CAM). Uji performa analisis PeAD terhadap ion logam berat Pb dan Cd dilakukan dengan pengukuran linearitas, Limit of Detection (LOD), Limit of Quantification (LOQ), interferensi, presisi, dan akurasi. Persamaan yang didapat dari uji linearitas, dengan y = 1.4508 + 0.1723 [Cd (II)] dengan R2 = 0.9839 dan y = 0.6789 + 0.1218 [Pb (II)] dengan R2 = 0.9851, yang menunjukkan bahwa nilai sensitivitas PeAD untuk logam Cd sebesar 1.4508 μA dan logam Pb sebesar 0.6434 μA, dan LOD untuk logam Cd dan Pb yaitu 6.43 µg/L dan 7.01 µg/L, dengan LOQ yaitu 22.07 µg/L dan 23.39 µg/L. ......Paper Electroanalytical Devices (PeAD) is one of the chemical sensor devices that has been widely developed due to its wide application in various field, one of which is detecting heavy metals. The working principle of PeAD is to measure the metal concentration from the reduction and oxidation reactions using the potentiometric method. In this study, PeAD was developed by the presence of in situ electrodeposition of Bismuth metal on the electrode, using square wave anodic stripping voltammetry (SWASV). Bismuth metal was deposited by forming a thin layer of Bi film on the electrode surface and then scanning with an electron microscope. Bismuth metal is used as an electrode modifier because it has the capacity to form alloys with heavy metals, such as Pb and Cd, as well as because it is less toxic and has a large negative potential window so that the process of bonding with metals can occur. Test for Variations in pH, variations in the deposition potential, and variations in the concentration of addition of Bismuth, were carried out to obtain optimum test results. The optimum conditions were obtained at a solution pH of 4.6 with a deposition potential of -1.2 V, with the addition of 1 mg/L Bismuth. The PeAD that were successfully fabricated were then characterized using Scanning Electron Microscopy (SEM), Fourier-Transform Infra-Red (FTIR), and Contact Angle Meter (CAM). Analysis performance test of PeAD for heavy metal ions Pb and Cd was carried out by measuring linearity, Limit of Detection (LOD), Limit of Quantification (LOQ), interference, precision, and accuracy. The equation obtained from the linearity test, with y = 1.4508 + 0.1723 [Cd (II)] with R2 = 0.9839 and with y = 0.6789 + 0.1218 [Pb (II)] with R2 = 0.9851, which shows that the metal sensitivity value of PeAD is 1.4508 µA for Cd and 0.6434 µA for Pb, and the LOD for Cd and Pb were 6.43 µg/L and 7.01 µg/L, with LOQ 22.07 µg/L and 23.39 µg/L.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library