Design couch spect gamma camera. Design has been carried out couch spect gamma camera. This plan aims to complement the patient's bed gamma camera of fiber glass materials. Methods of making fiber by fiber glass casting. The shape of the bed made curved in the middle to add strength. From the result of design gain is expected to be on the couch spect gamma camera is made of fiber glass.
Artikel Jurnal  Universitas Indonesia Library
cover
Abstrak :
Design couch spect gamma camera. Design has been carried out couch spect gamma camera. this plant aims to complement the patlent's bed gamma camera of fiber glass materials. Methods of making fiber by fiber glass casting. The shape of the bed made curved in the middle to add strength. From the result of design gain is expected to be on the couch spect gamma camera is made of fiber glass.
Artikel Jurnal  Universitas Indonesia Library
cover
Aditya Tri Oktaviana
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
T52314
UI - Tesis Membership  Universitas Indonesia Library
cover
Ismir Fahri
Abstrak :
Terapi reperfusi dengan IKPP pada pasien IMA-EST bertujuan menyelamatkan miokard dan menurunkan angka kematian. Kembalinya patensi arteri koroner epikardial dengan aliran TIMI derajat 3 tidak selalu berarti terjadinya aliran yang adekuat pada tingkat mikrovaskular, fenomena ini dikenal dengan istilah no reflow atau obstruksi mikrovaskular. Beberapa alat bantu diagnostik untuk mendeteksi kejadian obstuksi mikrovaskular telah banyak dikembangkan, namun sampai saat ini belum didapatkan baku emas. Mengetahui korelasi penilaian myocardial blush kuantitatif dengan program QuBE terhadap ukuran infark, fraksi ejeksi, volume akhir sistolik dan diastolik ventrikel kiri menggunakan SPECT Tc99m Tetrofosmin dalam 4-6 minggu paska IKPP pada pasien IMA-EST. Penelitian ini merupakan studi potong lintang. Gambaran angiografi pasien IMA-EST yang menjalani reperfusi dengan IKPP dari bulan Juli-Desember 2011 dievaluasi keberhasilannya mengunakan program ?QuBE?, dan pada minggu ke 4-6 paska IKPP dievaluasi dengan pemeriksaan SPECT Tc99m Tetrofosmin, untuk menilai ukuran infark, fraksi ejeksi, volume akhir sistolik dan diastolik ventrikel kiri. Dari 36 pasien didapatkan proporsi terbanyak berjenis kelamin laki-laki sebesar 94,4%, rata-rata usia pasien 54,3±7,9 tahun. Sebanyak 69,4% pasien dengan diagnosis IMA-EST anterior. Uji Spearman menunjukkan korelasi yang cukup antara nilai QuBE terhadap ukuran infark (-0,594 dan p < 0,001) dan fraksi ejeksi (r 0,531 dan P 0,001), volume akhir sistolik (r -0,496 dan P 0,002) dan volume akhir diastolik (r -0,435 dan P 0,008) ventrikel kiri. Sub analisis pada ATI LAD juga memberikan korelasi yang cukup pada keempat variabel tersebut, namun tidak pada ATI RCA. Uji multivariat parsial mengunakan kontrol variabel; usia, waktu iskemik, ATI, multivessel disease, faktor risiko PJK, kategori killip dan IMT, tetap menunjukkan nilai QuBE berkorelasi cukup dengan ukuran infark (r -0,441 dan p 0,019). Penilaian myocardial blush kuantitaif dengan program QuBE memiliki korelasi yang cukup terhadap ukuran infark, namun tidak menunjukkan korelasi terhadap fraksi ejeksi, volume akhir sistolik dan diastolik ventrikel kiri menggunakan SPECT Tc99m Tetrofosmin pada minggu ke 4-6 paska IKPP pada pasien IMAEST. ......Primary PCI as a reperfusion therapy in STEMI patients is aimed to salvage myocardium and reduce mortality. Successful restoration epicardial coronary artery patency with TIMI 3 flow has not always lead to adequate flow at microvascular level, these phenomena is known as no reflow or microvascular obstruction. Several diagnostic tools were developed to detect MVO, but until now there is no gold standard. knowing correlation between Quantitative Myocardial blush using QuBE program with infarct size, ejection fraction, systolic and diastolic volume of the left ventricle using SPECT Tc99m Tetrofosmin at 4-6 weeks after PPCI of STEMI patients. This study is designed as a cross sectional study. Selected angiographic result of STEMI patients that underwent primary PCI from July?December 2011 at The National Cardiac Center Harapan Kita were evaluated directly with the QuBE program. The infarct size, ejection fraction, end systolic and end diastolic volume of left ventricle were evaluated using SPECT Tc99m Tetrofosmin at 4-6 weeks after PPCI. Thirty six consecutive patients were enrolled. Proportion of men is 94.4% and age average of 54.3±7.9 years old. Most of patients were diagnosed with anterior STEMI (69.4%). Spearmen analysis obtained a moderate correlations between QuBE score and infarct size (r -0.594, p < 0.001), left ventricle ejection fraction (r 0.531, P 0.001), end diastolic volume (r -0.496, P 0.002), end systolic volume (r -0.435, P 0.008). Sub analysis based on IRA at LAD revealed the similar result of the four variables, but not with IRA at RCA. Partial multivariate analysis adjusted with age, ischemic time, IRA, multivessel disease, CAD risk factors, Killip class and BMI consistent showed moderate correlation of QuBE score with infarct size (r -0,441, p 0.019). Quantitative Myocardial blush using QuBE program revealed a moderate correlation with infarct size, but not with ejection fraction, systolic and diastolic volume of the left ventricle using SPECT Tc99m Tetrofosmin at 4-6 weeks after PPCI of STEMI patent.
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2012
T-Pdf
UI - Tesis Open  Universitas Indonesia Library
cover
Aida
Abstrak :
Kontrol kualitas adalah proses penting dalam pencitraan kedokteran nuklir. Tujuan kontrol kualitas (QC) adalah untuk mendeteksi degradasi dari performa sistem peralatan pencitraan seperti Single Photon Emisssion Computed Tomography (SPECT). Evaluasi parameter kontrol kualitas SPECT menggunakan fantom Jaszczak dan fantom in-house. Fantom Jaszczak untuk evaluasi citra uniformitas, kontras dan resolusi spasial dan fantom in-house untuk evaluasi citra hot. Evaluasi uniformitas menunjukkan konsentrasi aktivitas rendah 0.068 MBq/ml menunjukkan standar deviasi tinggi ±18.6 sedangkan konsentrasi aktivitas tinggi 0.235 MBq/ml menunjukkan standar deviasi rendah ±14.2. Hasil evaluasi kontras pada citra cold menunjukkan standar deviasi rendah ± 21.8 pada konsentrasi aktivitas terendah 0.068 MBq/ml dan standar deviasi tinggi ± 25.1 ditunjukkan pada konsentrasi aktivitas tinggi 0.235 MBq/ml, dan pada evaluasi citra hot standar deviasi rendah ±29.45 pada konsentrasi aktivitas terendah 0.5 MBq/ml dan standar deviasi tinggi ± 32.2 pada konsentrasi aktivitas tinggi 6.0 MBq/ml. Evaluasi pada standar deviasi menunjukkan kontras citra. Citra dengan standar deviasi tinggi menunjukkan kontras tinggi.
Quality control is an important process in imaging nuclear medicine. The aim of quality control (QC) is to detect degradation of the performance of imaging equipment systems such as Single Photon Emisssion Computed Tomography (SPECT). Evaluation QC SPECT parameters using Jaszczak phantom and in-house phantom. Jaszczak phantom for evaluation of uniformity, contrast and spatial resolution and in-house phantom for hot image evaluation. Uniformity evaluation showed a low activity concentration of 0.068 MBq/ml showed high standard deviation of ± 18.6 with high activity concentration of 0.235 MBq/ml showed low standard deviation ± 14.2. The results contrast evaluation on cold images showed low standard deviation ± 21.8 at the lowest activity concentration of 0.068 MBq / ml and a high standard deviation of ± 25.1 was shown at a high activity concentration of 0.235 MBq/ml, and low standard standard deviation image evaluation ± 29.45 at the lowest activity concentration 0.5 MBq/ml and high standard deviation ± 32.2 at high activity concentration of 6.0 MBq/ml. Evaluation standard deviation shows image contrast. Images with high standard deviation showed high contrast.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
T52332
UI - Tesis Membership  Universitas Indonesia Library
cover
M. Roslan Abdul Gani
Abstrak :
Dugaan penyakit jantung secara klinis dapat diketahui salah satunya dengan mengamati fungsi otot jantung ventrikel kiri dengan teknik kardiologi nuklir. Dengan metode ini, penyumbatan pembuluh darah koroner ditentukan untuk mengetahui kondisi fungsi otot jantung penyebab iskemik atau infark. Dalam penelitian ini dievaluasi fungsi otot jantung berdasarkan hasil prosentase perfusi, total skor perfusi dan fraksi ejeksi. Subjek yang dipilih adalah 31 pasien yang menjalani pemeriksaan MPI di Rumah Sakit Angkatan Darat Gatot Soebroto Jakarta, menggunakan radiofarmaka 99mTc-sestamibi. Pemeriksaan dilakukan dengan kamera gamma SPECT dual head yang dilengkapi dengan program QPS/QGS. Akuisisi data dilakukan dengan kondisi pasien pada saat stres dan istirahat. Dari hasil evaluasi data menggunakan statistik metode Pearson dan Spearman, diperoleh untuk semua segmen menunjukan korelasi kuat-positif. Berdasarkan data nilai prosentase perfusi pada kondisi stres dan istirahat, diperoleh hasil 8 orang normal dan diperkirakan 11 orang telah mengalami iskemia parsial, 8 orang iskemia total dan 4 orang infark parsial. ...... Suspicion on heart disease can be confirmed by observing the function of the left ventricle heart muscle with nuclear cardiology techniques. In this method, blockage of coronary arteries is determined by finding out the condition of heart muscle function causing ischemia or infarction. In this study, cardiac muscle function was evaluated based on the percentage of perfusion, total score of perfusion and ejection fraction. Subjects of thirty-one patients undergoing the MPI examination on Gatot Soebroto Jakarta Hospital using 99mTc-sestamibi radiopharmaceutical were chosen as samples. The examination was carried out with dual head SPECT equipped with QPS/QGS program. Data acquisitions were performed under patient's stress and rest conditions. Evaluation of the data using statistical methods of Pearson and Spearman was performed to all segments, indicating a strong correlation. As a result 11 subjects suspected for having partial ischemia, 8 subjects for total ischemia, 4 subjects for partial infarction, while the remainder 8 subjects normal.
Depok: Fakultas Matematika Dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
S60066
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Sharah Nataz Shilfa
Abstrak :
Penelitian ini bertujuan untuk memperoleh nilai resolusi spasial melalui pengukuran MTF dengan mengajukan model sampel terbarukan untuk metode LSF dan sumber titik pada PSF. Subjek yang digunakan untuk perolehan LSF terdiri atas empat jenis sampel yang direndam dalam larutan radioisotop 18F atau 99mTc 12 mCi dan PSF menggunakan sumber titik 2 mCi. Pencitraan sampel dilakukan menggunakan PET/CT dengan variasi filter terhadap algoritma rekonstruksi dan SPECT/CT dual head dengan variasi jenis kolimator. Hasil evaluasi penelitian ini menunjukkan nilai MTF 10 untuk masing-masing modalitas. Berdasarkan metode preparasi sampel dan konsistensi dari standar deviasi untuk pengukuran MTF pada masing-masing metode, rekomendasi program QC resolusi spasial untuk pesawat pada PET/CT dapat dilakukan berdasarkan metode LSF maupun PSF dan SPECT/CT dengan metode PSF.
This thesis was aim to obtained spatial resolution from MTF measurement by using novel phantom for LSF and point sources for PSF. LSF subject consists of four sample types which were incubated in 18F or 99mTc 12 mCi radioisotope solutions and PSF subject were 2 mCi point sources. PET CT with filters to algorithm reconstructions and dual head SPECT CT with collimator variation were used for scanning. The results given MTF 10 values for each modalities. Based on sample preparation and deviation consistency for MTF measurement per methods, QC recommendation of spatial resolution program in PET CT could be done by using LSF either PSF methods while in SPECT CT by using PSF method.
Depok: Universitas Indonesia, 2017
S67595
UI - Skripsi Membership  Universitas Indonesia Library