Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 4 dokumen yang sesuai dengan query
cover
Boca Raton: CRC Press, Taylor & Francis Group, 2009
621.366 APP
Buku Teks  Universitas Indonesia Library
cover
Kurnia Lahna
Abstrak :
A special interferometric technique with high sensitivity has been devised on the basis of rainbows refractometer without the use of an additional and delicate amplitude-splitting setup. This new technique was use for the characterization of shock wave plasma induced by a Q-sw Nd-YAG laser on various kinds of metal samples under reduced gas pressures. An unmistakable signal of density jump was detected simultaneously with the emission front signal. It is proved that at the initial stage of the secondary plasma expansion, the front of the emission and the front of the blast wave was coincide and move together with time. However, at a later stage, the front of the emission will separate from that of the blast wave induced in the surrounding gas at low pressures. Using Cu and Zn samples, the experimental result showed that the separation of the emission front and blast wave front took place at 4 mm above sample surface for the laser energy of 140 mJ.
2000
T4004
UI - Tesis Membership  Universitas Indonesia Library
cover
Hari Nurcahyadi
Abstrak :
ABSTRAK
Saat ini teknologi nuklir berkembang dengan baik di Indonesia dan pemanfaatannya baik di bidang kesehatan, pertanian, peternakan, industri dan energi digunakan sepenuhnya untuk kesejahteraan seluruh masyarakat Indonesia. Dalam pengembangan dan pemanfaatan teknologi nuklir tentu harus mempertimbangkan dan meminimalisir efek bahaya dari radiasi nuklir, baik untuk pekerja yang berada dilingkungan instalasi nuklir maupun bahaya kontaminasi lingkungan disekitar instalasi nuklir. Untuk itu kegiatan pemantauan, pendeteksian dan pengukuran radiasi mutlak diperlukan. Umumnya kegiatan pemantauan, pendeteksian dan pengukuran radiasi dilakukan dengan perangkat deteksi nuklir. Pada penelitian kali ini dilakukan metode alternatif pengukuran, analisis dan identifikasi unsur radioaktif dengan teknik laser induced plasma spectroscopy LIPS . Penggunaan teknologi LIPS dipilih karena LIPS adalah suatu teknik analisis sampel secara in situ, kualitatif dan kuantitatif yang cepat, dan hampir tanpa preparasi sampel. Analisis dan identifikasi unsur radiaoaktif dilakukan dengan menembakkan laser pulsa NdYAG Q-Switch 355 nm, 10 Hz, durasi pulsa 5.5 ns, f = 100 mm, dengan variasi energi 5.5 mJ - 140 mJ dan dengan variasi tekanan udara 4 Torr ndash; 1 atm pada sampel material radioaktif alamiah atau Naturally Occurring Radioactive Material NORM dengan metoda ablasi laser yang dilanjutkan dengan metoda spectral plasma analisis. Berdasarkan penelitian yang telah dilakukan, secara kualitatif teknik LIPS mampu mengidentifikasi adanya unsur radioaktif Uranium U dan Thorium Th yang terdapat pada sampel uji dengan energi laser optimum sebesar 107 mJ dan secara kuantitatif didapatkan nilai prediksi konsentrasi unsur Uranium sebesar 155 ppm dengan persentase error 11.3 dan nilai batas deteksi sebesar 7.89 ppm, nilai prediksi konsentrasi unsur Thorium sebesar 124 ppm dengan persentase error 8 dan nilai batas deteksi sebesar 12.4 ppm. Dengan kata lain teknik LIPS secara inheren sangat cocok dan sangat memungkinkan digunakan sebagai teknik pengukuran, analisis dan identifikasi keberadaan unsur radioaktif.
ABSTRACT
Nuclear technology is currently well developed in Indonesia and its use in the field of health, agriculture, industry and energy is completely used for the welfare of all the people of Indonesia. In the development and utilization of nuclear technology should certainly consider and minimize the effects of nuclear radiation hazards, both for the workers who are in the environment of nuclear installations and the danger of contamination of the environment around nuclear installations. Therefore monitoring activity, detection and measurement of radiation is absolutely necessary. Generally the monitoring activity, detection and measurement of radiation carried by the nuclear detection devices. In this study, alternative methods of measurement, analysis and identification of radioactive elements is carried out by using laser induced plasma spectroscopy LIPS . The use of LIPS technology is selected since LIPS is a technique in situ sample analysis, qualitative and quantitative fast, and almost no sample preparation. Analysis and identification of the radioactive element is carried out by firing laser pulses NdYAG Q Switch 355 nm, 10 Hz, pulse duration of 5.5 ns, f 100 mm, with a variation of the energy 5.5 mJ 140 mJ and with variations in air pressure 4 Torr 1 atm in a sample of Naturally Occurring Radioactive Material NORM with laser ablation method, followed by plasma spectral analysis method. Based on the research that has been done, LIPS technique is qualitatively able to identify the presence of radioactive elements, i.e. Uranium U and thorium Th contained in the test sample with a laser energy optimum of 107 mJ and quantitatively obtained predictive value of elemental concentrations of Uranium of 155 ppm along with 11.3 of percentage error and 7.89 ppm of detection limit value, also the predictive value of the elemental concentration of thorum of 124 ppm along with 8 of percentage error and 12.4 ppm of detection limit value. In other words, LIPS technique is inherently very suitable and it is possible to use as a measurement technique, analysis and identification of the presence of radioactive materials.
2016
T47405
UI - Tesis Membership  Universitas Indonesia Library
cover
Rinda
Abstrak :
A TEA CO2 laser pulse (50 mJ, 100 ns) was focused under reduced pressure on the silicone grease painted on copper plate as a sub-target with a power density of 6 GW/cm2. The comparison was made on the characteristics of the induced laser plasma between the two cases, with sub-target and without sub-target. It is proved that emission spectrum assigned to silicone atom can be detected only for the case with sub-target. It is also proved that in the absence of the sub-target, the gushing speed of the atoms is very low, while for the case with sub-target, the gushing speed of atoms becomes very fast. It is shown that the setting of sub-target is very effective to make laser-induced shock-wave plasma and it is very effective to realize quantitative analysis of soft material.
Depok: Program Pascasarjana Universitas Indonesia, 1998
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library