Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 228 dokumen yang sesuai dengan query
cover
Drysdale, Dougals
Abstrak :
"A new edition of the leading introduction to the science of fire phenomena, complete with the latest research, data and additional problemsThis book is unique in that it identifies fire science and fire dynamics and provides the scientific background necessary to the development of fire safety engineering as a professional discipline. It is essential reading for all involved in the field from fire safety engineering students to fire prevention officers. After 21 years as a bestseller, Dougal Drysdale's classic introduction has been brought up-to-date with the latest data and research in a third edition. Features numerical problems with answers illustrating the quantitative applications of the concepts presented. Includes quantitative experimental data regarding material properties. Successfully course-tested at Massachusetts' Worcester Polytechnic Institute and the University of Edinburgh, and widely adopted throughout the world. Of relevance to those working in building design, fire physics and chemistry. "-- "This book is unique in that it identifies fire science and fire dynamics and provides the scientific background necessary to the development of fire safety engineering as a professional discipline"--
Chichester, West Sussex: Wiley, 2011
541.361 DRY i
Buku Teks SO  Universitas Indonesia Library
cover
Achmad Firdaus
Abstrak :
Bangunan tinggi dapat menjadi tempat beraktivitas yang aman dan selamat apabila dilindungi oleh sistem proteksi kebakaran yang handal dan berfungsi baik. Sistem proteksi kebakaran merupakan fungsi sistematis keselamatan kebakaran untuk memastikan bangunan tinggi dapat menjadi tempat beraktivitas yang aman dan selamat. Penelitian tentang proteksi kebakaran, umumnya berfokus pada sistem proteksi aktif dan pasif, sarana penyelamatan jiwa dan evakuasi. Penelitian ini mencoba melihat sistem proteksi kebakaran dilihat dari perspektif Fire Safety Officer dari sistem manajemen keselamatan kebakaran gedung. Pengelolaan sistem proteksi kebakaran dan sebagai responder awal pada kejadian kebakaran gedung memerlukan peran aktif dari petugas pemadam kebakaran gedung (Fire Safety Officer/FSO) dari Sistem Manajemen Keselamatan Kebakaran Gedung. Metode pengumpulan data dan studi literatur dilakukan untuk mengidentifikasi fungsi-fungsi dan aktivitas yang mempengaruhi peran FSO. Penelitian ini menggunakan data primer dan sekunder. Data primer didapat dengan menyebarkan kuesioner dengan responden dari Dinas Penanggulangan Kebakaran dan Penyelamatan DKI Jakarta dan unit pengelola keselamatan kebakaran di beberapa gedung bertingkat di DKI Jakarta. Sebanyak 50 kuesioner disebar, dan 38 kuesioner diterima dan dianalisis menggunakan MS Excel untuk mendapatkan pengukuran dan indikator yang valid dan relevan. Pengolahan data menunjukkan beberapa fungsi dan indikator pada pengelolaan keselamatan kebakaran gedung terdiri dari fungsi Pencegahan Kebakaran, fungsi Monitoring Fungsi Perpipaan, Pompa Kebakaran dan peralatan lainnya, fungsi Penanggulangan Kebakaran, dan Aktivitas pasca terjadinya kebakaran. Hasil penelitian dapat memberikan informasi tentang daftar aktivitas yang harus dilakukan seorang FSO terhadap kehandalan sistem proteksi kebakaran gedung untuk meminimalkan dampak kerugian properti dan korban jiwa. ......High-rise building is a safe and comfortable place of activities when protected by a fireprotection system that is reliable and functioning properly. Fire Protection System is a systematic function of fire safety management to ensure that high rise building to be a safe place for activities. The researches of fire protection are mostly focused on active and passive fire protection systems, life-saving and fire egress. This study aims to examine fire protection systems from the perspective of fire safety officer as an important part of fire safety management to ensure the fire protection system performance properly. The management of fire protection system an as initial responder needs the active role of building fire safety officer (FSO) as a part of building fire safety management. Data collection and literature review are conducted to identify functions and activities factors needed that influence the role of FSO through the primary and secondary datas. Primary datas are conducted by spreading questionaire to several responder from DKI Jakarta Fire and Rescue Department and several high-rise building in DKI Jakarta. 50 questionaire were spreaded and 38 questionaire received and analyzed using MS Excel to have the relevant and valid indicators. Data result showed several functions and activities consist of the functions of fire protection, functions of firepump and other fire equipment monitoring, functions of fire management, and activities of post-fire. The results of research are to provide informations for the activities of FSO significantly to building fire protection systems to minimize the impact of property losses and casualties.
Depok: Fakultas Teknik Universitas Indonesia, 2019
T53061
UI - Tesis Membership  Universitas Indonesia Library
cover
Erdi Aron Primariawan
Abstrak :
Kebakaran adalah suatu peristiwa tidak terduga dan menimbulkan banyak kerugian. Hal ini dapat terjadi pada gedung-gedung yang tidak memiliki sistem perlindungan serta manajemen kebakaran dan keselamatan. Para pengelola gedung khususnya gedung tinggi perkantoran, harus memiliki beberapa standar kebakaran, salah satunya adalah design sistem proteksi pasif. Design sistem proteksi pasif sangat penting bagi bangunan sebagai sistem untuk menahan penjalaran asap dan api dalam bangunan saat terjadi bahaya kebakaran. Penelitian ini digunakan untuk meneliti komponen kinerja design sistem proteksi pasif apa saja yang mempengaruhi keandalan bangunan dalam hal keselamatan terhadap bahaya kebakaran. Penelitian ini menggunakan data primer dan sekunder. Data primer didapat dengan menyebarkan 90 kuesioner ke gedung-gedung tinggi perkantoran di DKI Jakarta. 34 kuesioner telah diterima dan kemudian 27 kuesioner dianalisa dengan menggunakan program statistik SPSS 11.00 untuk mendapatkan pengukuran dan indikator-indikator yang relevan. Pengolahan data menunjukkan beberapa parameter design sistem proteksi pasif yang terdiri dari (1) design tanda-tanda penunjuk jalan keluar=56,6%, (2) design pintu penyekat api=20% dan design tempat parkir=6,3%. Hasil dari penelitian ini dapat digunakan sebagai persyaratan design bangunan tinggi perkantoran dalam mengurangi dampak bahaya kebakaran.
The fire damage occurs in unpredictable time and can cause losses to owner because of damage. It can occur in buildings that do not have Fire Protection and Fire Safety Management System in the building. A building management, especially for high-rise office building, should meet certain standards; one of them is fire prevention through a passive protection system design. The existence passive protection system design is important for building as a system for containing fire and smoke in case of fire. This research is used to observe factor of passive protection system design that influence the reliability of building in preventing and controlling the damages used by fire in high-rise office building. This research uses primary and secondary data. Distributing 90 questionners gather primary data to various high-rise offices building in DKI Jakarta. 34 responses were received to be viable for in, dept analysis, 27 data gathered is then analyzed by using statistic program SPSS 11.00 to obtain measurable and relevant indicators. Data analysis shows same parameters in Fire Safety Management, which are (I) design of exit sign = 56,6%, (2) design of fire resisting doors = 20% and design of parking area = 6,3%. The result at this research can be used as a minimum design requirement for high-rise office building design, for its reliability in fire safety design.
Depok: Fakultas Teknik Universitas Indonesia, 2004
T14747
UI - Tesis Membership  Universitas Indonesia Library
cover
Nur Septiana Wulandari
Abstrak :
Kasus kebakaran yang terjadi pada gedung perkuliahan/kampus masih sering terjadi, padahal gedung perkuliahan/kampus merupakan pusat berlangsungnya proses kegiatan belajar-mengajar serta kegiatan administrasi. Skripsi ini bertujuan untuk mengevaluasi penerapan keselamatan kebakaran gedung dengan menggunakan software Computerized Fire Safety Evaluation System (CFSES) di FMIPA dan FF Universitas Indonesia yang terletak di Kampus UI, Depok. Metodologi menggunakan desain studi deskriptif dengan pendekatan semi kuantitatif dan dibantu dengan perangkat lunak Computerized Fire Safety Evaluation System (CFSES)yang mengacu pada 12 parameter keselamatan yang ada pada NFPA 101A Guide on Alternative Approaches to Life Safety. Sampel gedung yang dievaluasi terdiri dari tiga gedung yaitu gedung F (Fisika) dan I (Dekanat) FMIPA UI serta gedung Fakultas Farmasi UI. Berdasarkan hasil penelitian pada 10 gedung di FMIPA dan 1 gedung di Fakultas Farmasi dengan melihat kesesuaian 12 safety parameters, tidak ada gedung yang memenuhi standar NFPA 101 : Life Safety Code ®. Rekomendasi yang dapat diberikan adalah memasang sistem proteksi kebakaran seperti sprinkler, menutup semua bukaan vertikal, membuat gudang khusus penyimpanan barang, dan mengadakan pelatihan tanggap darurat secara berkala. ......Cases of fires that occurred in the lecture building/campus still common, whereas the lecture building/campus is central to the process of teaching and learning activities as well as administrative activities. Purpose this study is to evaluate implementation of fire safety in FMIPA and FF University of Indonesia buildings. Methodology of this study is using observational design with semiquantitatives approaches and assisted with Computerized Fire Safety Evaluation System (CFSES) software that refers to 12 of parameters in NFPA 101A Guide on Alternative Approaches to Life Safety. Building sample that evaluated consist of three buildings, F (Physics) building and I (Dean) building FMIPA UI and Faculty of Pharmacy of UI building. Based on the results of research in the FMIPA UI building at 10 and 1 building at the Faculty of Pharmacy of UI to see the suitability of 12 safety parameters, there are no buildings that meet the standards of NFPA 101: Life Safety Code ®. Recommendation that can be given is to install fire protection systems such as sprinklers, close all vertical openings, make special warehouse storage of goods, and conduct periodical fire emergency response training.
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2014
S55213
UI - Skripsi Membership  Universitas Indonesia Library
cover
Chicago: the International City Managers’ Association, 1936
352.309 73 MUN
Buku Teks  Universitas Indonesia Library
cover
Windy Noermala Prawira
Abstrak :
Skripsi ini membahas mengenai evaluasi APAR di gedung A FKM UI dengan membandingkan antara kondisi yang ada dengan peraturan-peraturan terkait. Selain itu, juga dijelaskan mengenai analisis konsekuensi yang ditimbulkan dari hasil evaluasi tersebut, sehingga diketahui keefektifan APAR untuk memadamkan api.. Penelitian ini adalah penelitian kualitatif dengan analitik deskriptif menggunakan metode event tree analysis. Hasil penelitian menunjukan bahwa APAR digedung A FKM UI hanya mempunyai keefektifan 5.7%. Hal ini dikarenakan Pemasangan APAR yang terkunci dalam kotak box tanpa palu pemukul kaca sehingga mempersulit seseorang untuk memperoleh, selain itu juga dikarenakan tidak adanya pemeriksaan secara berkala yang memastikan bahwa APAR berada dalam kondisi yang dapat dioperasikan. Dan konsekuensi yang akan ditimbulkan adalah ketidakefektifan APAR pada saat digunakan untuk memadamkan kebakaran kecil.
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2009
S-Pdf
UI - Skripsi Open  Universitas Indonesia Library
cover
Harman, Thomas L.
New Jersey: Prentice-Hall, 1981
R 343.73 Har g
Buku Referensi  Universitas Indonesia Library
cover
Muhammad Fahmy Kautsar
Abstrak :
Penilitian ini bertujuan untuk mengevaluasi penerapan keselamatan kebakaran gedung dengan menggunakan perangkat lunak Computerized Fire Safety Evaluation System (CFSES) di Fakultas Psikologi Universitas Indonesia. Evaluasi dilakukan dengan menilai 12 Safety Parameter dan persyaratan tambahan yang terdapat pada NFPA 101A: Alternate Approach to Life Safety dIsesuaikan dengan standard dari NFPA 101: Life Safety Code. Gedung Fakultas Psikologi Universitas Indonesia yang dievaluasi adalah gedung A, C, D, dan H. Didapatkan kesimpulan bahwa tidak satupun gedung yang dievaluasi memenuhi nilai persyaratan keselamatan minimum pada NFPA 101: Life Safety Code. ......This study has the purpose to evaluate the fire safety of buildings using software Computerized Fire Safety Evaluation System (CFSES) at the Faculty of Psychology, University of Indonesia. Evaluation is done by assessing 12 Safety parameters and additional requirements contained in NFPA 101A: Alternate Approach to Life Safety adjusted to the standard of the NFPA 101: Life Safety Code. Faculty of Psychology, University of Indonesia, which is evaluated is building A, C, D, and H. Obtained conclusion that none of the evaluated buildings meet minimum safety requirements on the value of NFPA 101: Life Safety Code.
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2014
S57100
UI - Skripsi Membership  Universitas Indonesia Library
cover
Wahyu Aditya
Abstrak :
Lapangan minyak Kotabatak merupakan salah satu lapangan minyak yang dikelola oleh production area Kotabatak Petapahan (Kopet) Sumatra Light South PT CPI. Lapangan minyak Kotabatak memberikan kontribusi sebesar 80% terhadap produksi harian minyak mentah production area Kotabatak Petapahan dan memberikan kontribusi sebesar 20% terhadap produksi harian minyak sub operation unit Sumatra Light South. Di lapangan minyak Kotabatak terdapat stasiun pengumpul Kotabatak. Penelitian mengenai bahaya kebakaran belum membahas secara terperinci peristiwa kebocoran hidrokarbon dan dampak peristiwa kebakaran hidrokarbon. Perusahaan PT CPI memiliki komitmen untuk melindungi masyarakat dan lingkungan sekitar serta melaksanakan kegiatan operasi dengan handal dan efisien. Oleh karena itu perlu dilakukan penelitian untuk mengetahui bentuk kebakaran hidrokarbon dan dampak kebakaran hidrokarbon yang dapat terjadi di stasiun pengumpul Kotabatak. Penelitian ini memiliki tujuan umum untuk mengetahui bentuk dan dampak kebakaran hidrokarbon yang mungkin terjadi di stasiun pengumpul Kotabatak Sumatra Light South PT CPI. Tujuan khusus Penelitian ini ini adalah mengetahui bentuk kebakaran yang dapat teljadi di stasiun pengumpul Kotabatak, mengetahui dampak kebakaran hidrokarbon jenis kebakaran tangki pada wash tank T-2B dan peristiwa bola api pada separator V-5 terhadap manusia yang berada wilayah di stasiun pengumpul Kotabatak, mengetahui dampak kebakaran hidrokarbon jenis kebakaran tangki pada wash tank T-2B dan peristiwa bola api pada separator V-5 yang dapat terjadi terhadap aset yang terdapat di stasiun pengumpul Kotabatak. Manfaat penelitian ini adalah memberikan informasi mengenai bentuk dan dampak kebakaran hidrocarbon di stasiun pengumpul Kotabatak, memberikan bagi Sumatra Light South PT CPI, mcnambah pengetahuan peneliti mengenai proses analisis dampak kebakaran serta dapat menjadi dasar bagi penelitian selanj utnya. Dcsain penelitian ini adaiah anaiisis dampak kcbakaran dengan menggunakan metode penilaian bahaya kebakaran. Pendekatan yang digunakan adalah pemodelan matematika. Analisis dampak kcbakaran dilakukan untuk mengetahui dampak kebakaran hidrokarbon tcrhadap rnanusia dan aset yang berada di dalam wilayah stasiun pengumpul Kotabatak. Dampak kebakaran yang dinilai adalah radiasi panas. Hasil yang didapatkan dari penelitian ini adalah bentuk kebakaran yang dapat teijadi di stasiun pengumpui minyak Kotabatak adalah kebakaran tangki, trench jire, kebakaran kolam, jetfire/torch fire, flash fire, vapor cloud explosion, dan peristiwa bola api. Dampak kebakaran terhadap manusia akibat peristiwa kebakaran tangki pada wash tank T-2B adalah rasa sakit pada radius sampai dengan 40 meter dari titik tengah tangki setelah paparan panas selama 1 detik. Luka bakar tingkat 1 pada radius sampai dengan 16 meter setelah paparan panas selama l detik. Luka bakar tingkat 2 pada radius sampai dengan 26 meter sampai dengan 30 meter dari titik tengah tangki seteiah paparan panas selama 2 detik. Luka bnkar tingkat 3 dan kematian pada jarak 14 meter sarnpai dengan 18 meter dari titik tengah tangki setelah paparan panas selama 6 detik. Dampak peristiwa bola api terhadap manusia adalah manusia yang berada pada jarak antara 5 meter sampai dengan '7 meter dari titik tengah separator V-5 akan mengalarni Iuka bakar tingkat tiga dan dapat menyebabkan kematian. manusia yang berada pada jarak antara 9 meter sampai dengan 11 meter dari titik tengah separator V-5 akan mengalami Iuka bakar tingkat dua. Pengamat yang berada pada jarak antara 14 meter sampai dengan 16 meter mengalami luka bakar tingkat satu dan merasakan sakit akibat radiasi panas. Dampak kebakaran tangki wash tank T-2B terhadap peralatan dan fasilitas adalah tangki dan pipa yang berada pada radius 24 meter dari titik tengah akan mengalami kerusakan bahan dan rncngalami distorsi. Tangki dan pipa baja yang tidak dilengkapi dengan pelindung panas serta bejana tekan pada radius 40 meter akan mengalami kerusakan bahan. Tangki dan pipa baja dengan ketebalan tipis dan dilengkapi lapisan pelindung panas yang berada pada radius 60 meter akan mengalami kerusakan bahan. Fasilitas pengkabelan yang bemda pada radius 132 meter sampai dengan 182 meter akan mengalami kerusakan. Kayu yang berada pada radius 40 meter akan terbakar. Kayu, kenas, dan cat berada pada radius 60 meter akan mencapai kondisi siap untuk terbakar. Dampak peristiwa bola api di separator V-5 adalah tangki dan pipa yang berada pada radius 8 meter terdistorsi dan mengalami kerusakan bahan. Tangki dan pipa yang berada pada radius 8 meter sampai 10 meter mengalami kerusakan bahan. Tangki dan pipa dengan ketebalan tipis yang berada pada radius 14 meter akan mengalami kenrsakan bahan. Fasilitas pengkabelan yang berada pada radius 32 meter sampai dengan 44 meter akan mengalami kerusakan. Bahan yang dapat terbakar yang berada pada radius 2 meter dari titik tengah separator V-5 akan terbakar. Bahan yang dapat terbakar yang berada pm radius 16 meter mencapai kondisi siap untuk terbakar. ......Kotabatak oilfield is operated by operated by Kotabatak Petapahan (Kopet) production area under the responsibility of Sumatra Light South, Kotabatak oilfield contribute to 80 % of Kotabatak Petapalran production area daily oil production and contribute to 20 % of Sumatra Light South sub operation unit daily oil production. Kotabatak gathering station is located at Kotabatak oiltield. Current research performed about tire hazard at Kotabatak Gathering station, does not specifically analyze hydrocarbon tire and consequences of hydrocarbon tire. Chevron Pacific Indonesia has a cormnitment to protect the people and the environment and to perform their activity excellently and ehiciently. So it is needed to perform a research to know the type of hydrocarbon fire and consequence of hidrocarbon tire that might be happen at Kotabatak gathering station. The aim of this research is to identify the type of hydrocarbon tire and its consequences which might oecrrr at Kotabatak gathering station. The objective of this research is to identify the type of hydrocarbon fire that might be happen at Kotabatak gathering station, to identify the consequences of tank fire at wash tank T-2B and fireball at separator V-5 to human kind at Kotabatak gathering station and to identify the consequences of tank 'tire at wash tank T-2B and ireball at separator V-5 to asset and facilities at Kotabatak gathering station. The benefit of this research is to give information about the form of hydrocarbon fire and consequence of hydrocarbon tire at Kotabatak gathering station, Sumatra Light South will have a reference for (irrther Kotabatak gathering station development, and will be the basis for further research. The design of this research is tire consequence analysis. This research is using tire hazard assessment method. the approach used in mis research is mathematical modeling. Consequence analysis is performed to know the consequence of hydrocarbon fire to human kind and asset at Kotabatak gathering station. Heat radiation is analyzed as the consequence of fire in this research. The result of this research is the form of hydrocarbon fire that may be happen at Kotabatak gathering station are tank tire, trench tire, pool tire, jet tire/torch tire, ilash Ere, vapor cloud explosion, and fireball. The consequence of tank fire at wash tank T-2B to human kind are pain at a radius up to 40 meters &om the center of wash tank T-2B alier an exposure for l second, first degree burn at a radius up to 16 meters after an exposure for 1 second, second degree bum at a radius from 26 meters up to 30 meters after an exposure for 1 second, and third degree burn at a radius from 14 meters up to 18 meters alter an exposure for 6 second. The consequence of iirebail at separator V-5 to human kind are pain and first degree burn at a radius from 14 meters up to 16 meters from the center of separator V-5 alter, second degree burn at a radius from 9 meters up to 11 meters, and third degree bum at a radius from 5 meters up to 7 meters. Third degree burn may cause direct fatality. The consequence of tank fire at wash tank T -2B to asset at Kotabatak gathering station are tanks and pipes at a radius up to 24 meters will be distorted and damaged, steel tanks and steel pipes which is not protected with heat protective coating at a radius up to 40 meters will be damaged, thin steel tanks and thin steel pipes which is protected with heat protective coating at a radius up to 60 meters will be damaged, wiring at a radius from 132 meter up to 182 meters will be damaged, wood at a radius up to 40 meters will be bum, and combustible at a radius up to 60 meters will be ready to ignite. The consequence of fireball at separator V-5 to asset at Kotabatak gathering station are tanks and pipes at a radius up to 8 meters will be distorted and damaged, tanks and pipes at a radius &om 8 meters up to 10 meters will be damaged, thin steel tanks and thin steel pipes at a radius up to 14 meters will be damaged, wiring 'at a radius from 32 meter up to 44 meters will be damaged, combustible at a radius up to 2 meters will be bum, and combustible at a radius up to I6 meters will be ready to ignite.
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2008
T34383
UI - Tesis Open  Universitas Indonesia Library
cover
Muhammad Rifai Kurniawan
Abstrak :
Kota Depok memiliki tingkat pertumbuhan dan perkembangan yang cukup pesat. Meningkatnya jumlah penduduk yang sejalan dengan meningkatnya kepadatan penduduk, turut menyebabkan timbulnya wilayah permukiman yang padat. Permukiman padat merupakan salah satu ruang yang paling rawan terhadap bahaya kebakaran. Pembentukan wilayah rawan kebakaran diperlukan sehingga diketahuinya wilayah mana saja yang rawan terhadap bencana kebakaran Kota Depok. Tujuan penelitian ini adalah untuk menganalisis pola wilayah kejadian kebakaran dan pola wilayah rawan kebakaran. Data yang digunakan diantaranya kejadian kebakaran, kepadatan penduduk, respon time, kerapatan jaringan jalan, sumber air, lokasi UPT, dan kepadatan bangunan. Penelitian wilayah rawan kebakaran yang terjadi pada tahun 2018 menggunakan metode overlay, network analisis dan menggunakan analisis spasial serta deskriptif. Hasil penelitian ini menunjukan wilayah kejadian kebakaran tinggi berada di utara Kota Depok, dan disebabkan oleh konsleting listrik. Sedangkan wilayah rawan kebakaran tinggi pada umumnya memiliki karakteristik kepadatan penduduk tinggi, kerapatan jaringan tinggi, kepadatan bangunan tinggi, respon time lambat dan sumber air rendah ......Depok City has a fairly rapid growth and development rate. The increase in population in line with increasing population density also contributes to the emergence of dense residential areas. Dense settlements are one of the spaces most vulnerable to fire hazards. The formation of fire-prone areas is needed so that it knows which areas are prone to the Depok City fire disaster. The purpose of this study was to analyze the patterns of the area of fire and the pattern of areas prone to fire. Data used include fire incidents, population density, response time, road network density, water source, UPT location, and building density. Research on fire-prone areas that occurred in 2018 using the overlay method, network analysis and using spatial and descriptive analysis. The results of this study showed that the area of high fire was in the north of Depok City, and was caused by electrical short circuit. While high fire-prone areas generally have characteristics of high population density, high tissue density, high building density, slow response time and low water sources
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>