Abstrak :
Danau Kenanga direncanakan akan menjadi salah satu sumber air baku untuk Instalasi Pengolahan Air (IPA) yang akan dibangun berdasarkan dokumen Rencana Induk Sistem Penyediaan Air Minum (RISPAM) Universitas Indonesia. Namun, berdasarkan dokumen RISPAM, konsentrasi pencemar amonia dan nitrit tidak memenuhi baku mutu kelas I PP No. 22 Tahun 2021. Penelitian ini ditujukan untuk mengidentifikasi sumber pencemar, menganalisis konsentrasi, menganalisis beban pencemar, menyimulasi dinamika pencemar, dan menyusun strategi intervensi guna meningkatkan kualitas air Danau Kenanga untuk parameter amonia, nitrit, dan nitrat. Parameter amonia, nitrit, dan nitrat akan diukur konsentrasinya dengan pengujian lab dan disimulasikan transpor, reaksi, dan skenario perbaikan kualitas air menggunakan metode numerik Runge-Kutta orde keempat berbasis kesetimbangan massa. Pengambilan sampel air akan dilakukan pada 4 titik untuk mendapatkan kualitas air eksisting Danau Kenanga. Sampel air diambil pada waktu pagi, siang, dan sore pada hari Minggu, Senin, dan Selasa. Berdasarkan hasil pengujian, air Danau Kenanga tidak memenuhi baku mutu kelas I PP No. 22 Tahun 2021 untuk parameter amonia dan nitrit karena memiliki konsentrasi amonia berkisar antara 0,487 – 1,013 mg/L dan konsentrasi nitrit berkisar 1 – 3,667 mg/L, sedangkan konsentrasi nitrat yang berkisar 0,667 – 2,467 mg/L memenuhi baku mutu. Hasil simulasi kondisi eksisting menunjukkan konsentrasi amonia, nitrit, dan nitrat memiliki tren menurun. Hasil validasi model menunjukkan bahwa model dikatakan valid untuk variabel relatif tidak terkontrol. Skenario perbaikan kualitas air dibuat sebanyak 5 buah dengan mengendalikan sumber pencemar dari inlet Danau Kenanga. Skenario 1 menggunakan constructed wetland dan pengaturan debit, Skenario 2 menggunakan fitoremediasi dan pengaturan debit, Skenario 3 merupakan gabungan Skenario 1 dan 2, Skenario 4 merupakan intervensi oleh pemerintah dengan membangun IPAL komunal, dan Skenario 5 merupakan gabungan Skenario 3 dan Skenario 4. Skenario 5 merupakan skenario terpilih karena dapat meningkatkan kualitas air Danau Kenanga dan mengurangi konsentrasi amonia dan nitrit sehingga dapat memenuhi baku mutu kelas I PP No.22 Tahun 2021. Peningkatan kualitas air pada Skenario 5 terjadi pada hari ke 5 untuk amonia dan hari ke 7 untuk nitrit. ......Kenanga Lake was planned to be one of raw water source for Water Treatment Plant (WTP) that will be build based on University of Indonesia Drinking Water Supply System Master Plan (RISPAM). However, based on RISPAM the concentration of ammonia and nitrite pollutant doesn’t meet the quality requirements of class I water standard, as stated in PP No. 22 of 2021. This study is conducted to identify pollutant sources; analyze the concentrations and loadings, simulate pollutant dynamics, and develop intervention strategies to improve Kenanga Lake water quality for ammonia, nitrite, and nitrate parameters. Ammonia, nitrite, and nitrate concentrations will be measured by laboratory testing and simulated transport, reactions, and water quality improvement scenarios using the Runge-Kutta numerical method based on mass balance. Water sampling will be carried out at 4 points to obtain the existing water quality of Kenanga Lake. Water samples were taken in the morning, afternoon, and evening on Sunday, Monday, and Tuesday. Based on the test results, Kenanga Lake water did not meet the quality requirement of class I water standard from PP No. 22 of 2021 for ammonia and nitrite because it has ammonia concentrations ranging from 0.487 – 1.013 mg/L and nitrite concentrations ranging from 1 – 3.667 mg/L, while nitrate concentrations ranging from 0.667 – 2,467 mg/L meet the quality standards. The simulation results of the existing conditions show that the concentration of ammonia, nitrite, and nitrate has a downward trend. The results of model validation indicate that the model is said to be valid for relatively uncontrolled variables. Five scenarios for improving water quality were made by controlling the pollutant sources from the Kenanga Lake inlet. Scenario 1 uses constructed wetlands and discharge regulation, Scenario 2 uses phytoremediation and discharge regulation, Scenario 3 is a combination of Scenarios 1 and 2, Scenario 4 is an intervention by the government by building a communal WWTP, and Scenario 5 is a combination of Scenario 3 and Scenario 4. Scenario 5 is the selected scenario because it can improve the water quality of Kenanga Lake and reduce the ammonia and nitrite concentrations to meet the class I from PP No.22 of 2021 water quality standard. The water quality improvement in Scenario 5 occurs on day 5 for ammonia and day 7 for nitrite.
[Depok, Depok]: [Fakultas Teknik Universitas Indonesia, Fakultas Teknik Universitas Indonesia], 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hana Nur Arifah
Abstrak :
Danau Kenanga merupakan salah satu dari enam danau UI yang berperan sebagai daerah resapan air. Namun danau ini telah tercemar oleh berbagai jenis sampah organik dan anorganik, sedimen, residu pestisida, dan kontaminan lainnya, sehingga dapat menurunkan kualitas air. Oleh karena itu, penelitian ini bertujuan untuk mengoptimalkan proses pengolahan air Danau Kenanga dengan menerapkan metode Hybrid Ozonation-Coagulation (HOC), dengan fokus pada variasi pH dan dosis koagulan. Metode HOC diharapkan dapat meningkatkan efisiensi penghilangan polutan organik dan memastikan air memenuhi baku mutu kesehatan lingkungan. Analisis parameter seperti kandungan logam besi, mangan, pH, Total Dissolved Solid (TDS), total koliform, dan jumlah lumpur dilakukan untuk mengevaluasi efektivitas HOC. Hasil penelitian menunjukkan bahwa HOC merupakan metode yang paling efektif dibandingkan metode koagulasi dan ozonasi dalam pengolahan air Danau Kenanga dengan persentase perubahan TDS sebesar 18,18% dan persentase penyisihan kekeruhan sebesar 93,7%, logam Fe 84,75%, total coliform 99,69% , nilai logam Mn sebesar 0,1 mg/L, jumlah lumpur yang terakumulasi sebesar 1,4708 g pada pH 8 dan dosis koagulan Fe sebesar 50 ppm. ......Lake Kenanga is one of the six UI lakes which acts as a water catchment area. However, this lake has been polluted by various types of organic and inorganic waste, sediment, pesticide residues, and other contaminants, which can reduce water quality. Therefore, this research aims to optimize the Lake Kenanga water treatment process by applying the Hybrid Ozonation-Coagulation (HOC) method, with a focus on variations in pH and coagulant dosage. The HOC method is expected to increase the efficiency of removing organic pollutants and ensure that water meets environmental health quality standards. Analysis of parameters such as iron metal content, manganese, pH, Total Dissolved Solid (TDS), total coliform, and amount of sludge was carried out to evaluate the effectiveness of HOC. The results of the research show that HOC is the most effective method compared to coagulation and ozonation methods for treating Kenanga Lake water with a TDS change percentage of 18.18% and a turbidity removal percentage of 93.7%, Fe metal 84.75%, total coliform 99.69%, and the Mn metal value is 0.1 mg/L at pH 8 and the Fe coagulant dose is 50 ppm.
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alfandi Kurnianto
Abstrak :
ABSTRACT
Eutrofikasi menyebabkan kualitas air mengalami penurunan. Danau Kenanga yang dimiliki Universitas Indonesia UI memiliki inputan air limbah yang berasal dari aliran Sungai Ciliwung dan bangunan di sekitarnya. Pencemar nitrogen dominan dalam air limbah yang masuk ke danau ini. Kelebihan nitrogen di badan air dapat menyebabkan eutrofikasi. Untuk melihat perilakunya di badan air, maka dibuat suatu pemodelan konsentrasi total nitrogen terhadap waktu dengan pertimbangan denitrifikasi serta pola persebaran konsentrasinya. Dalam pembuatan model, mekanisme yang diperhitungkan adalah peluruhan, pengendapan dan denitrifikasi. Asumsi sistem danau dibagi menjadi 4 segmen dengan tipe CSTR Continuously Stirred Tank Reactor , asumsi loading berasal dari saluran Pondok Cina dan saluran Masjid UI dengan menggunakan step-loading termodifikasi. Perhitungan penurunan konsentrasi total nitrogen terhadap waktu menggunakan metode numerik runge-kutta orde keempat. Pemetaan pola distribusi total nitrogen dilakukan menggunakan surfer 13.0. Laju peluruhan total nitrogen sebesar 0,192 /hari, simulasi model memiliki kesalahan relatif terhadap observasi sebesar 15,2 dengan nilai MAE 0,15. Mekanisme denitrifikasi mereduksi total nitrogen selama seminggu pada Sistem A, B, C, D masing-masing sebesar 0,015 mg/l, 0,0065 mg/l, 0,905 mg/l dan 0,92 mg/l. Denitrifikasi mampu mengurangi nitrogen dalam badan air namun dalam jumlah yang relatif kecil. Pola sebaran konsentrasi yang terdapat pada danau sangat dipengaruhi oleh intervensi debit dan hujan.
ABSTRACT
Eutrophication can causes low water quality. Lake Kenanga owned by University of Indonesia UI has its wastewater input from the Ciliwung River and its surrounding buildings. Nitrogen contaminants are dominant in its wastewater input. Rising nitrogen in water bodies can cause eutrophication. Therefore, to see its behavior in the lake, modeling concentration of total nitrogen with time consider denitrification model and its pattern distribution concentration. This model mechanisms include decay, settling and denitrification. The lake system was divided into 4 segment with CSTR Continuously Stirred Tank Reactor type, the loading assumed comes from 2 channel Pondok Cina and Masjid UI using modified step loading. The concentration changes with time was calculated using numerical method runge kutta 4th order. Mapping distribution concentration of total nitrogen using surfer 13.0 Decay rate of total nitrogen is 0,192 day, model simulation has a relative error 15,2 and MAE value is 0,15. Denitrification mechanism reduced total nitrogen in System A, B, C, D up to 0,015 mg l, 0,0065 mg l, 0,905 mg l and 0,92 mg l respectively. Denitrification can reduce nitrogen in water bodies though in relatively small amounts. The intervention from inputs and rain greatly influence changes of the pattern distribution concentration on the lake.
2017
S67771
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ricky Emarpasha
Abstrak :
Pada tahun 2019, RISPAM UI memaparkan wacana untuk menggunakan Danau Kenanga sebagai sumber air baku air minum di kawasan Kampus Universitas Indonesia, Depok. Oleh karenanya, Danau Kenanga perlu memenuhi syarat kualitas dari air baku mutu kelas I, sebagaimana tercantum pada PP No. 22 Tahun 2021. Guna memenuhi syarat kualitas tersebut, DO dan BOD, selaku parameter organik, perlu memenuhi standar baku mutu. Penelitian ini bertujuan untuk menganalisis konsentrasi, mengidentifikasi sumber pencemar, menganalisis beban pencemar, menyimulasi skenario, dan menyusun strategi untuk meningkatkan kualitas air pada Danau Kenanga. Simulasi dilakukan berbasis prinsip kesetimbangan massa Metode Runge-Kutta orde 4 dengan menggunakan Microsoft Excel. Model dibangun menggunakan kualitas eksisting danau yang diambil dari 4 titik pada Danau Kenanga. Sampel air diambil pada hari Minggu, Senin, dan Selasa, masing-masing pada waktu pagi, siang, dan sore hari. Berdasarkan temuan lapangan, terdapat 2 sumber pencemar pada Danau Kenanga, yaitu dari aliran Kali Baru dan dari bangunan sekitar danau. Hasil uji lapangan menunjukan konsentrasi DO pada Danau Kenanga sudah memenuhi baku mutu kelas I PP No. 22 Tahun 2021 dengan konsentrasi sebesar 4,63 – 6,8 mg/L, namun hasil uji laboratorium konsentrasi BOD tidak memenuhi baku mutu dengan nilai sebesar 5,9 – 10,8 mg/L. Hasil simulasi selama 10 hari menunjukan konsentrasi DO Danau Kenanga memenuhi baku mutu pada hari ke-9 dengan konsentrasi akhir hari ke-10 sebesar 6,05 mg/L. Sedangkan hasil simulasi BOD Danau Kenanga selama 10 hari memiliki tren turun dengan nilai akhir sebesar 3,65 mg/L pada hari ke-10, di mana angka tersebut tidak memenuhi baku mutu. Peneliti membuat 5 skenario yang merupakan kombinasi dari 3 strategi untuk meningkatkan kualitas air Danau Kenanga, khususnya BOD. Strategi 1 merupakan pengurangan debit inlet dan outlet Danau Kenanga sehingga beban pencemar yang masuk juga berkurang, strategi 2 melalui pembangunan constructed wetland pada inlet danau sehingga konsentrasi pencemar masuk danau akan berkurang, dan strategi 3 yaitu bioremediasi menggunakan tanaman teratai sehingga memperbesar tingkat degradasi BOD pada danau. Skenario 2 yang terdiri dari kombinasi strategi 1 dan strategi 2 dapat meningkatkan kualitas air Danau Kenanga dengan ekonomis, efektif, dan efisien serta dapat memenuhi baku mutu kelas I PP No. 22 Tahun 2021. ...... In 2019, a plan to use Kenanga Lake as a source of raw water for drinking in the University of Indonesia Campus area, Depok, was presented in RISPAM UI. As such, Kenanga Lake needs to meet the quality requirements of class I standard water, as stated in PP No. 22 of 2021. In order to meet these quality requirements, DO and BOD need to meet the required standards as organic parameters. This study aims to analyze concentrations, identify pollutant sources, analyze pollutant loads, simulate scenarios, and develop strategies to improve Kenanga Lake’s water quality. The simulation was carried out based on the principle of mass balance of the Runge-Kutta 4th Order Method using Microsoft Excel. The model was built using Kenanga Lake's real-time quality taken from 4 locations within the lake. Water samples were taken on Sunday, Monday, and Tuesday in each morning, afternoon, and evening. Based on field findings, there are 2 sources of pollution in Kenanga Lake, namely from the Kali Baru stream and from buildings around the lake. Results show that the DO concentration in Kenanga Lake has met the class I standard as stated in PP No. 22 of 2021 with a concentration of 4.63 – 6.8 mg/L, although laboratory results show that the BOD concentration does not meet the quality standard with a value of 5.9 – 10.8 mg/L. The simulation results for 10 days showed that the DO concentration of Kenanga Lake met the quality standard on the 9th day with a final concentration of 6.05 mg/L at the end of the 10th day. Meanwhile, the results of the Kenanga Lake BOD simulation for 10 days showed a downward trend with a final value of 3.65 mg/L on the 10th day, in which this figure did not meet the quality standard. The researcher suggests 5 scenarios, which are a combination of 3 strategies, to improve the water quality of Kenanga Lake, namely its BOD. Strategy 1 is to reduce the inlet and outlet discharge of Kenanga Lake so that the incoming pollutant load is also reduced, strategy 2 is through the growth of constructed wetlands at the lake inlet so that the concentration of pollutants entering the lake will be reduced, and strategy 3 is through bioremediation using lotus plants so as to increase the BOD degradation in the lake. Scenario 2, which is a combination of strategy 1 and strategy 2, can improve the water quality of Kenanga Lake economically, effectively, and efficiently to meet the class I standard of PP No. 22 of 2021.
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ratu Nayasza Atikah Mangkuprawira
Abstrak :
Air Danau Kenanga merupakan salah satu sumber yang dapat diolah untuk memenuhi tingginya kebutuhan air higiene dan sanitasi seiring dengan berkembangnya populasi masyarakat di Indonesia. Metode pengolahan yang digunakan adalah hybrid ozonation-coagulation (HOC) menggunakan koagulan poly aluminium chloride (PAC). Metode gabungan ini dipilih karena keterbaruannya dan memiliki efektivitas yang lebih tinggi dibandingkan dengan metode konvensional. Pada penelitian ini, variasi yang digunakan adalah pH (6,7,8) dan dosis koagulan (100 ppm, 300 ppm, 500 ppm). Parameter yang ditinjau terdiri dari perubahan pH, penyisihan logam berat, perubahan TDS, penyisihan kekeruhan dan perubahan total koliform. Hasil terbaik yang diperoleh pada metode gabungan adalah pH 7 dengan dosis koagulan PAC 100 ppm yang dapat memenuhi seluruh nilai pada standar baku mutu air higiene dan sanitasi sesuai Peraturan Menteri Kesehatan Republik Indonesia Nomor 2 Tahun 2023. Nilai-nilai yang didapatkan di tiap parameter adalah 6,79 untuk pH, 111 mg/L untuk TDS, 0,015 mg/L untuk Fe, 0,1 mg/L untuk Mn, 0 NTU untuk kekeruhan, dan 0 CFU/100 mL untuk total koliform. Sedangkan di metode konvensional (koagulasi-flokulasi dan ozonasi), tidak seluruh parameter memenuhi standar baku mutu yang ditentukan. ......Kenanga Lake’s water is one of the sources that can be treated to meet the high demand for hygiene and sanitation water along with the growing population in Indonesia. The treatment method used is hybrid ozonation-coagulation (HOC) using poly aluminum chloride (PAC) coagulant. This combined method was chosen because of its novelty and has higher effectiveness compared to conventional methods. In this study, the variations used were pH (6,7,8) and coagulant dosage (100 ppm, 300 ppm, 500 ppm). The parameters reviewed consisted of changes in pH, heavy metal removal, changes in TDS, turbidity removal and changes in total coliform. The best result obtained in the combined method is pH 7 with a coagulant dose of 100 ppm PAC which can meet all values in the hygiene and sanitation water quality standards according to the Regulation of the Minister of Health of the Republic of Indonesia Number 2 of 2023. The values obtained in each parameter are 6.79 for pH, 111 mg/L for TDS, 0.015 mg/L for Fe, 0.1 mg/L for Mn, 0 NTU for turbidity, and 0 CFU/100 mL for total coliform. While in the conventional method (coagulation-flocculation and ozonation), not all parameters meet the specified quality standards.
Depok: Fakultas Teknik Universitas Indonesia, 2024