Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 14 dokumen yang sesuai dengan query
cover
cover
Supriyono
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
T40079
UI - Tesis Membership  Universitas Indonesia Library
cover
Yuris Diksy
Abstrak :
ABSTRAK
Sensor COD dipreparasi dengan menggunakan elektroda kawat Cu dan elektroda pensil grafit C yang dimodifikasi dengan lapisan tipis nanopartikel tembaga nano-Cu . Preparasi dilakukan secara elektrokimia dan morfologi permukaan elektroda nano-Cu/Cu dan nano-Cu/C dipelajari dengan scanning electron microscope SEM dan energy dispersive X-Ray spectrometer EDX menunjukkan ukuran partikel dengan variasi antara 50-750 nm dengan persen Cu sekitar 0,81-14,35 . Aplikasi kedua elektroda dalam analisis COD dipelajari dengan menggunakan glukosa dan glisina sebagai model. Reaksi oksidasi glukosa dan glisina dalam larutan NaOH 0,075 M, dipelajari dengan linear sweep voltammetry menunjukkan puncak oksidasi pada 0,68 V dan 0,67 V vs Ag/AgCl berturut-turut untuk elektroda nano-Cu/Cu dan nano-Cu/C. Pengaruh konsentrasi Cu2 , waktu deposisi, jumlah siklik, dan scan rate dipelajari untuk menentukan kondisi optimum percobaan. Kedua elektroda kerja yang dimodifikasi memberikan hasil deteksi amperometrik standar COD glukosa-glisina dengan linearitas yang baik R2 > 0,990 pada rentang konsentrasi 17,25-176,00 mg/L COD. Limit deteksi didapatkan sebesar 15,28 mg/L untuk elektroda nano-Cu/Cu dan 15,07 mg/L untuk elektroda nano-Cu/C. Sensor COD yang dibuat memberikan presisi yang baik dengan akurasi pada rentang 85,54- 102,42 dan 85,45-107,86 . Dibandingkan dengan nilai COD teoritis sensor yang dibuat memberikan nilai 95,33 dan 90,00 untuk elektroda nano-Cu/Cu dan elektroda nano-Cu/C. Kata kunci: chemical oxygen demand, sensor, kawat tembaga, nano-Cu, glukosa dan glisina
ABSTRACT
AbstractCOD sensor was prepared by using Cu wire electrodes and graphite pencil electrode C modified with a thin layer of copper nanoparticles nano Cu . The sensor was prepared by electrochemical method. The surface morphology of the prepared nano Cu Cu and nano Cu C electrodes was investigated by scanning electron microscope SEM and energy dispersive X Ray spectrometer EDX showed that the particle size was varied between 50 750 nm and percentage of Cu about 0.81 14.35 . The applications of electrodes in the COD analysis were studied using glucose and glycine as the models. The oxidation reaction of a mixture solution of mg L glucose and mg L glycine in 0.075 M NaOH solution was investigated using linear sweep voltammetry showed an oxidation peaks at 0.68 V and 0.67 V vs. Ag AgCl respectively for nano Cu Cu and nano Cu C electrodes. The effects of the Cu2 concentration, deposition time, cyclic amount, and scan rate were studied to determine the optimum conditions of the experiment. The amperometric detection of COD in prepared electrodes showed a good linearity R2 0.990 in the concentration range of 17.25 176 mg L COD. The estimated detection limit was obtained at 15.28 mg L for the nano Cu Cu electrode and 15.07 mg L for the nano Cu C electrode. COD sensors showed good precision and accuracy in the range 85.54 ndash 102.42 and 85.45 ndash 107.86 . Compared with theoretical COD values the sensors made provided 95.33 dan 90.00 value respectively for nano Cu Cu and nano Cu C electrodes.Keywords chemical oxygen demand, sensor, copper wire, nano Cu, glucose and glycine
Depok: Fakultas Ekonomi dan Bisnis Universitas Indonesia, 2018
T50461
UI - Tesis Membership  Universitas Indonesia Library
cover
Aldo Raventio Adam
Abstrak :
TPST (Tempat Pengolahan Sampah Terpadu) Bantargebang memiliki IPAS (Instalasi Pengolahan Air Sampah) yang dapat mengolah air lindi hingga 150 m3/hari. Air lindi yang dihasilkan IPAS III Bantargebang Bekasi mengandung zat atau kontaminan berbahaya yang perlu diolah agar memenuhi baku mutu lingkungan sebelum dapat dialirkan ke badan air. Tujuan utama penelitian ini adalah menganalisis efektivitas proses Fenton Heterogen dan Foto-Fenton Heterogen sebagai pengolahan lanjutan (Advanced Oxidation Process - AOP) air lindi. Reaksi Fenton Heterogen yang merupakan reaksi yang menghasilkan hydroxyl radical (*OH) untuk mengoksidasi senyawa organik maupun anorganik dapat meningkat berkali lipat apabila diradiasikan dengan UV / cahaya tampak yang biasa disebut sebagai Foto-Fenton. Parameter warna meningkat setelah proses Fenton akibat leaching besi dari katalis. Desain eksperimen menggunakan analisa tren grafik digunakan untuk menganalisis pengaruh parameter operasional yaitu pH, ORP, Warna, COD, besi, dan residu H2O2. Kondisi eksperimen diatur agar pH 4, rasio konsentrasi H2O2 : COD adalah 1:1, waktu detensi 60 menit, dan rasio P/V 32 W/L. Hasil eksperimen menunjukan bahwa reaksi Fenton Heterogen (FH) memberikan penyisihan warna mencapai 43% dan penyisihan COD mencapai 69%. Reaksi Foto(UV)-Fenton Heterogen dapat memberikan penyisihan warna mencapai 33% dan penyisihan mencapai COD 84%. Reaksi Foto(VIS)-Fenton Heterogen dapat memberikan penyisihan warna mencapai 67% dan penyisihan COD mencapai 84%. Keseluruhan hasil eksperimen menunjukan bahwa reaksi Foto(VIS)-Fenton Heterogen dapat memiliki efisiensi penyisihan warna dan COD yang lebih tinggi dibanding reaksi Fenton lainnya. Maka dari itu, reaksi Foto(VIS)-Fenton Heterogen merupakan metode pengolahan lindi paling optimal yang dapat diterapkan di IPAS III Bantargebang. ......Bantargebang TPST (Tempat Pembuangan Sampah Terpadu) has an IPAS (Instalasi Pengolahan Air Sampah, leachate water treatment plant) which treats leachate up to 150 m3/day. The leachate treated by IPAS III Bantargebang Bekasi contains hazardous substances or contaminants that must be treated to meet environmental quality standards before being discharged into water bodies. This study's main objective is to analyze the effectiveness of Heterogeneous Fenton and Heterogeneous Photo-Fenton processes as an Advanced Oxidation Process (AOP) of leachate. Heterogeneous Fenton reaction, which is a reaction that produces hydroxyl radicals (*OH) to oxidize organic and inorganic compounds, can increase many times when irradiated with UV / visible light, which is commonly referred to as Photo-Fenton. Color increase after Fenton reaction because leaching process if catalyst. The experimental design using graph trend analysis was used to analyze the effect of operational parameters, namely pH, ORP, Color, COD, iron, and H2O2 residue. The experimental conditions were set to pH 4, the concentration ratio of H2O2: COD was 1:1, the detention time was 60 minutes, and the P/V ratio was 32 W/L. The experimental results showed that the Heterogeneous Fenton reaction (FH) gave a colour removal of 43% and a COD removal of 69%. Heterogeneous Photo(UV)-Fenton reaction can provide colour removal up to 33% and removal up to 84% COD. Heterogeneous Photo(VIS)-Fenton reaction can provide colour removal of up to 67% and COD removal of up to 84%. Overall experimental results show that the Heterogeneous Photo(VIS)-Fenton reaction can have a higher efficiency of colour removal and COD than other Fenton reactions. Therefore, the Heterogeneous Photo(VIS)-Fenton reaction is the optimal leachate treatment method applied at IPAS III Bantargebang.
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fathya Khalisa Manzis
Abstrak :
Air limbah domestik merupakan air limbah yang berasal dari aktivitas hidup sehari-hari manusia yang berhubungan dengan pemakaian air. Untuk mengetahui karakteristik air limbah diperlukan pengujian segera setelah sampel diambil, namun pada realitanya seringkali sampel tidak dapat langsung diuji dan membutuhkan waktu tunggu penyimpanan sebelum diuji di laboratorium. Penelitian ini bertujuan untuk menganalisis pengaruh waktu tunggu terhadap perubahan konsentrasi dan laju penurunan konsentrasi, serta memprediksi konsentrasi awal berdasarkan perubahan konsentrasi BOD dan COD. Penentuan koefisien laju penurunan dilakukan menggunakan fitur “Trendline” jenis eksponensial dari grafik scatter plot pada Microsoft Excel, sedangkan analisis prediksi konsentrasi awal dilakukan dengan pemodelan menggunakan solusi persamaan diferensial reaksi orde pertama. Hasil penelitian menunjukkan bahwa konsentrasi BOD menurun seiring waktu tunggu, sedangkan konsentrasi COD mengalami peningkatan setelah turun terlebih dahulu. Diperoleh rata-rata koefisien laju penurunan BOD sebesar 0,278/hari pada sampel tanpa pengawetan dan 0,13/hari pada sampel dengan pengawetan, sedangkan rata-rata koefisien laju penurunan COD sebesar 0,046/hari pada sampel tanpa pengawetan dan 0,0185/hari pada sampel dengan pengawetan. Hasil pemodelan untuk memprediksi konsentrasi awal BOD reliabel hingga hari ke-2 penyimpanan pada sampel tanpa pengawetan dan hari ke-2,25 penyimpanan pada sampel dengan pengawetan. Sementara itu, hasil pemodelan untuk memprediksi konsentrasi awal COD reliabel hingga hari ke-21 penyimpanan pada sampel dengan pengawetan, namun tidak reliabel sama sekali pada sampel tanpa pengawetan. ......Domestic wastewater originates from daily human activities involving the use of water. To determine the characteristics of wastewater, testing is required immediately after sample collection. However, samples often cannot be tested immediately and require a holding period before laboratory testing. This study aims to analyze the impact of holding time on the concentration changes and the degradation rate, as well as to predict the initial concentration based on changes in BOD and COD concentrations. The determination of the degradation rate coefficient was performed using the "Trendline" feature with an exponential type from the scatter plot graph in Microsoft Excel, while the analysis of the initial concentration prediction was conducted through modeling using the solution of the first-order reaction differential equation. The results showed that BOD concentration decreases over the holding time, whereas COD concentration increases after initially decreasing. The average degradation rate coefficient for BOD was found to be 0.278/day in samples without preservation and 0.13/day in preserved samples, while the average degradation rate coefficient for COD was 0.046/day in samples without preservation and 0.0185/day in preserved samples. The modeling results for predicting the initial BOD concentration were reliable up to the 2nd day of storage for samples without preservation and the 2.25th day for preserved samples. Meanwhile, the modeling results for predicting the initial COD concentration were reliable up to the 21st day of storage in preserved samples but not reliable at all in samples without preservation.
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Khairina Damara
Abstrak :
Pengolahan air limbah domestik PT GS Battery dengan Bio Kleen Sewage System masih menghasilkan konsentrasi amonia effluen yang melebihi baku mutu. Aerated Submerged Fixed Film Reactor yang diketahui mampu mengolah beban amonia tinggi, diterapkan untuk mengolah air limbah tersebut dan dievaluasi selama 45 hari. Penelitian skala laboratorium dilakukan menggunakan bioreaktor dengan kapasitas 5.6 L yang dioperasikan pada waktu detensi yang berbeda, yaitu 6, 8, dan 10 jam. Lumpur aktif resirkulasi dari instalasi pengoalahan air limbah Jababeka digunakan sebagai lumpur pembibitan. Kualitas influen penelitian memiliki laju beban Chemical Oxygen demand COD dari 1181 sampai 1987 g COD m-3 hari-1 dan laju beban analisis dari 134 sampai 223 g NH3-N m-3 hari-1. Hasil penelitian menunjukkan performa yang lebih baik pada HRT 10 jam, dimana sistem mencapai 90 ndash; 93 dan 94 ndash; 99 pada efisiensi penyisihan COD dan analisis. Data yang diperoleh menunjukkan nilai R-kuadrat 0.87 dan 0.85. Konsentrasi effluen COD dan amonia memiliki rentang 36 ndash; 60 mg/L dan 0.4 ndash; 5 mg/L dimana keduanya telah memenuhi standar baku mutu di Indonesia. Penelitian ini juga menunjukkan dua kondisi aerobik dan anaerobik dapat bekerja dalam satu bioreaktor. ......Domestic wastewater treatment in PT GS Battery using Bio Kleen Sewage System still produced ammonia concentration above effluent discharge standard. Aerated Submerged Fixed Film Reactor which known for its ability to treat high ammonia loading, was used and evaluated during 45 days. Laboratory experiment were conducted using a bioreactor with 5.6 L capacity operated at different hydraulic retention times, which were 6, 8, and 10 hours. Return activated sludge from wastewater treatment plant of Jababeka was taken as seed sludge. The influent of the experiment has Chemical Oxygen Demand COD loading rate from 1181 to 1987 g COD m 3 day 1 and ammonia loading from 134 to 223 g NH3 m 3 day 1. Results indicated better performance at 10 hours rsquo retention time that the system was able to achieve 90 ndash 93 and 94 ndash 99 removal efficiencies of COD and ammonia. Data gained exhibited the R squared value were 0.87 and 0.85. The effluent COD and ammonia concentration ranged between 36 ndash 60 mg L and 0.4 ndash 5 mg L which lower than the Indonesian national discharge standards for both parameters. The present study showed also two conditions of aerobic and anaerobic could be worked in a single bioreactor.
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67608
UI - Skripsi Membership  Universitas Indonesia Library
cover
Zenifer Patricia Lumban Raja
Abstrak :
Tidak seluruh sampah yang diangkut oleh kendaraan pengangkut sampah dibuang ke TPA, bahkan 7,54% dibuang ke badan air. Penelitian ini bertujuan untuk menganalisis pengaruh jenis sampah anorganik spesifik terhadap parameter COD dan amonia pada badan air, yaitu Sungai Ciliwung. Pengambilan sampel air Sungai Ciliwung dilakukan secara grab sampling. Metode yang digunakan untuk mengetahui adanya pengaruh jenis sampah anorganik spesifik dan waktu kontak terhadap konsentrasi COD dan amonia adalah uji normalitas dan kruskal wallis. Sementara itu, metode yang digunakan untuk menganalisis laju degradasi COD dan nitrifikasi amonia menggunakan ODE Linear faktor pengintegrasian. Berdasarkan hasil pengujian normalitas menunjukan data tidak terdistribusi normal, sehingga dilanjutkan dengan uji kruskal wallis yang menunjukakan bahwa jenis sampah anorganik spesifik dan waktu kontak mempengaruhi konsentrasi COD dan amonia. Nilai k1 COD untuk sampah plastik sachet adalah 0,0085 per hari dan 0,005 per hari. Sementara, nilai k2 COD untuk sampah plastik sachet adalah 0,055 per hari. Nilai k1 COD untuk sampah kain polyester adalah 0,0006 per hari dan 0,00032 per hari. Sementara, nilai k2 COD untuk sampah kain polyester adalah 0,055 per hari dan 0,099 per hari. Untuk nilai k1 amonia pada sampah plastik sachet adalah 0,00000075 per hari dan 0,000001 per hari. Sementara, nilai k2 amonia untuk sampah plastik sachet adalah 0,0247 per hari. Nilai k1 amonia untuk sampah kain polyester adalah 0,0000004 per hari dan 0,00000028 per hari. Sementara, nilai k2 amonia untuk sampah kain polyester adalah 0,0247 per hari dan 0,0346 per hari. Pada dasarnya, sampah anorganik membutuhkan waktu yang sangat lama untuk dapat terdegradasi. Oleh karena itu, keberadaannya dapat dikategorikan sebagai cemaran yang berpotensi membahayakan kesehatan masyarakat dan lingkungan. ......Not all of the solid waste transported by waste transport vehicles is disposed to the landfill, even 7.54% is disposed to water bodies. This study aims to analyze the effect of specific inorganic waste types on COD and ammonia parameters in a body of water, namely the Ciliwung River. Sampling of Ciliwung River water was carried out by grab sampling. The method used to determine the effect of specific inorganic waste types and contact time on COD and ammonia concentrations is the normality test and Kruskal Wallis. Meanwhile, the method used to analyze the degradation rate of COD and ammonia uses the ODE Linear integrating factor. Based on the results of the normality test, the data was not normally distributed, so it was continued with the Kruskal Wallis test which showed that the specific type of inorganic waste and contact time affected COD and ammonia concentrations. The k1 COD value for plastic sachet waste is 0.0085 per day and 0.005 per day. Meanwhile, the k2 COD value for plastic sachet waste is 0.055 per day. The k1 COD values for polyester fabric waste were 0.0006 per day and 0.00032 per day. Meanwhile, the value of k2 COD for polyester fabric waste is 0.055 per day and 0.099 per day. For the k1 value of ammonia in plastic sachet waste is 0.00000075 per day and 0.000001 per day. Meanwhile, the k2 value of ammonia for plastic sachet waste is 0.0247 per day. The k1 value of ammonia for polyester fabric waste is 0.0000004 per day and 0.00000028 per day. Meanwhile, the value of k2 ammonia for polyester fabric waste is 0.0247 per day and 0.0346 per day. Basically, inorganic waste takes a very long time to be degraded. Therefore, its presence can be categorized as a contaminant that has the potential to endanger public health and the environment.
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Alem Sinatrya
Abstrak :
Dalam rangka pemenuhan tujuan pengembangan tata kelola air berdasarkan Rencana Induk Master Plan Kampus Baru UI Depok serta konservasi air dalam peningkatan kinerja sumber daya air, kualitas air Danau Mahoni harus memenuhi standar baku mutu Peraturan Pemerintah Nomor 22 Tahun 2021 kelas II untuk air danau. Studi ini dilakukan dengan maksud untuk menganalisis kondisi eksisting beban pencemar organik Danau Mahoni, mengembangkan model terkait pembebanan IPAL pencemar dan memprediksikan pembebanan organik IPAL tersebut sesuai dengan skenario yang digunakan. Salah satu variabel yang paling umum digunakan untuk menggambarkan kualitas badan air adalah Dissolved Oxygen (DO) dan jumlah material organik, yang biasa direpresentasikan dalam parameter Biochemical Oxygen Demand (BOD) dan Chemical Oxygen Demand (COD). Parameter ini diukur dengan pengujian lab dan disimulasikan dalam sistem dinamis menggunakan software Vensim. Berdasarkan pengujian sampel yang telah dilakukan, konsentrasi DO telah memenuhi baku mutu dengan rentang nilai 4,1 – 6,2 mg/L, konsentrasi BOD belum memenuhi baku mutu dengan rentang nilai 5,16 – 8,76 mg/L dan konsentrasi COD belum memenuhi baku mutu di beberapa waktu pengambilan sampel dengan rentang nilai 21 – 31 mg/L. Berdasarkan hasil simulasi kondisi eksisting, konsentrasi DO mengalami fluktuasi dan mencapai keadaan steady state pada konsentrasi 5 mg/L, konsentrasi BOD mengalami fluktuasi dan mencapai keadaan steady state pada konsentrasi 6,71 mg/L dan konsentrasi COD mengalami penurunan dan mencapai keadaan steady state pada konsentrasi 15 mg/L. Berdasarkan hasil validasi model, tingkat akurasi model terhadap sistem nyata termasuk ke dalam kategori baik. Terdapat 2 skenario yang disimulasikan untuk meningkatkan kualitas air Danau Mahoni hingga memenuhi standar baku mutu DO, BOD dan COD untuk air danau. Skenario 1 mengaplikasikan IPAL di setiap fakultas sesuai dengan karakteristik pencemarnya dan Skenario 2 mengaplikasikan IPAL seperti Skenario 1 ditambah floating constructed wetland pada Danau Mahoni. Berdasarkan hasil simulasi kedua skenario, skenario yang memenuhi standar baku mutu DO, BOD dan COD air danau adalah Skenario 2. ......To meet the objective of Universitas Indonesia New Campus Depok Master Plan water use as well as water conservation in improving the performance of water resources, Mahoni Lake water quality must meet the quality standards of Government Regulation No. 22 of 2021 class II for lake water. This study aims to analyze existing organic loading of Mahoni Lake, develop WWTP loading model and predict organic loading on used scenario. The variables that’s commonly used to represent water quality is Dissolved Oxygen (DO) and the amount of organic matter, represented in form of Biochemical Oxygen Demand (BOD) and Chemical Oxygen Demand (COD). These parameters are measured by lab testing and simulated in a dynamic system using Vensim software. Based on the tests, the DO concentration has met the quality standard with the value between 4,1 – 6,2 mg/L, the BOD concentration has not met the quality standard with the value between 5,16 – 8,76 mg/L and the COD concentration has not met the quality standard in several sampling times with the value between 21 – 31 mg/L. Based on the simulation, DO concentration fluctuated and reached a steady state at 5 mg/L, the BOD concentration fluctuated and reached a steady state at 6,71 mg/L and the COD concentration decline and reached a steady state at 15 mg/L. Based on model validation, the level of accuracy of the model on the real system is good. Two scenarios are simulated to improve the water quality of Mahoni Lake to meet the DO, BOD and COD quality standards for lake water. Scenario 1 applies WWTP in each faculty based on the characteristics of the pollutant and Scenario 2 applies WWTP as Scenario 1 and floating constructed wetland in Mahoni Lake. Based on the results of the scenario simulation, the scenario that meets the DO, BOD and COD quality standards for lake water is Scenario 2.
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abstrak :
The qualities of the treated final effluents of a wastewater treatment plant located in a rural community of the Esaterm Cape Province of South Africa were assessed over the duration of 12 months....
Artikel Jurnal  Universitas Indonesia Library
cover
Lady Chair Raza
Abstrak :
Proses produksi industri perminyakan terdiri dari proses primer dan proses sekunder yang menghasilkan limbah dengan kandungan fenol dan COD tinggi dengan konsentrasi berkisar antara 200,23-329,73 mg/L dan 960,24-1.196,58 mg/L. Adsorpsi merupakan salah satu alternatif pengolahan fisik untuk mengurangi zat pencemar di dalam air limbah yang memiliki desain sederhana dan mudah dalam pengoperasiannya. Pada penelitian ini, percobaan adsorpsi dilakukan secara batch dan kontinyu. Dari hasil penelitian, adsorpsi secara batch dapat mengurangi konsentrasi fenol dan COD mencapai 99,93% dan 94,49% dengan kombinasi dosis adsorben dan waktu kontak optimum 40 g/L dan 95 menit. Pada percobaan kontinyu didapatkan persentase penyisihan fenol 100-56%, COD 97-48%, amonia 100-71%, sulfida 100-5% dalam waktu operasi 235 jam. Efisiensi regenerasi dengan ethanol 100% untuk fenol dan 70% untuk COD. Data equilibrium adsorpsi fenol dan COD menunjukkan kecocokan dengan model isotherm Langmuir dan Freundlich. Data kinetika adsorpsi menunjukkan kecocokan dengan pseudo-second order model dengan nilai laju kinetika kfenol=1,247 g/mg/menit dan kCOD=0,0082 g/mg/menit. Aplikasi di lapangan membutuhkan 2 unit kolom adsorpsi dan 1 unit cadangan, dengan diameter 2 m dan tinggi total 6,5 m. ...... The production process of petroleum industry consists of primary processing and secondary processing that produce waste with a high content of phenol and COD concentrations ranging between 200,23-329,73 mg/L dan 960,24-1.196,58 mg/L. Adsorption is a physical treatment alternative for reducing pollutants in wastewater which has a simple design and easy in operation. In this study, the adsorption experiments performed in batch and continuous. From the result of this research, batch adsorption can reduce the concentration of phenol and COD in wastewater of petroleum industry up to 99,93% and 94,49% with a combination of adsorbent dosage and optimum contact time each of 40 g/L and 95 minutes. he continuous experiments removed 100-56% of phenol, 97-58% of COD, 100-71% of ammonia, 100-5% sulfide in 235 hours operation. Efficiency of regeneration using ethanol up to 100% of phenol and 70% of COD. Adsorption equilibrium data of phenol and COD were best fitted by Langmuir and Freundlich isotherm models. Adsorption kinetics data were best fitted by the pseudo-second order kinetics model with a rate value kfenol=1,247 g/mg/menit and kCOD=0,0082 g/mg/menit. Applications in the field required 2 column adsorption units and 1 reserve unit with a diameter of 2 m and a total height of 6,5 m.
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59437
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2   >>