Abstrak :
ABSTRACT
We proposed a method for measuring the temperature by using Mach - Zehnder Interferometer, one arms of Mach - Zehnder Interferometer was used as a test arms which was disturbed by an object, it's temperature was to be measured. In our experiment, we used a combustion flame and a heated welder with temperature variation as a testing object.

System, contains He - Ne laser source, two beams splatters and two mirrors which form two arms of interferometer, with a length of 1,06 meter.

The experiment results shows that the variation of temperature could give the difference of fringe spacing at the screen. Several photographs of fringe pattern on the screen have been successfully taken on both under temperature disturbance and normal condition.

The comparison between the fringe spacing under those two conditions could give the information about temperature of the testing objects.

This result was also compared with the measurement using thermocouple with digital display. This comparison gives us a good agreement.
1992
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Reza Putra Setyawan
Abstrak :
Urbanisasi yang cepat terutama di daerah tropis telah menjadi perhatian serius akhir-akhir ini. Pembangunan tipe "sprawl" telah ditemukan di beberapa negara dimana pembangunan perumahan dan komersial dengan kepadatan rendah meluas hingga ke pinggiran luar kota. Karena keadaan ini, sebagian besar ruang hijau pada akhirnya akan mengalami degradasi yang menyebabkan fenomena yang disebut Urban Health Island (UHI) dan heat stress. Selain itu, peningkatan populasi perkotaan juga akan mempengaruhi peningkatan pembangunan gedung. Lebih dari sepertiga dari total kebutuhan konsumsi energi yang diperlukan untuk menyediakan kondisi ruangan yang nyaman dengan sistem pendingin, pemanas, dan ventilasi, menjadi tanggung jawab sektor bangunan. Penggunaan sistem pendingin ruangan yang berlebihan pada sebuah bangunan dapat menyebabkan peningkatan konsumsi energi, emisi gas, dan juga polusi udara di luar ruangan. Karena negara-negara di daerah tropis memiliki iklim yang panas dan lembab, sebagian besar bangunan di daerah tersebut membutuhkan sistem pengkondisian ruangan terutama dengan pendinginan dan dehumidifikasi. Suhu dan kelembaban di dalam ruangan tergantung pada seberapa banyak panas yang masuk ke dalam ruangan. Istilah ini disebut sebagai perolehan panas, dimana sebagian besar berasal dari radiasi matahari yang masuk melalui atap. Salah satu cara terbaik untuk mengurangi heat gain tanpa mempengaruhi konsumsi energi dan lingkungan adalah dengan menggunakan Closed Loop Pulsating Heat Pipe (CLPHP). Pada penelitian ini, kinerja sistem atap CLPHP diuji dengan menggunakan dua jenis fluida kerja, yaitu air murni dan etanol murni. Sistem atap CLPHP kemudian dibandingkan dengan kondisi ketika sistem atap tidak menggunakan CLPHP dengan menggunakan metode eksperimen. Hasil eksperimen menunjukkan bahwa pada 113 W/m2, sistem atap CLPHP dengan etanol FR 55% memiliki resistansi termal terendah yaitu 0,224 K/W dan akan memberikan penurunan temperatur loteng sebesar 2,4◦C. Pada 270 W/m2, sistem atap CLPHP dengan air FR 70% memiliki resistansi termal terendah sebesar 0,160 K/W dan dapat memberikan pengurangan suhu loteng sebesar 3,1◦C. Pada 355 W/m2, sistem atap CLPHP dengan air FR 70% memiliki resistansi termal terendah sebesar 0,095 K/W dan dapat memberikan pengurangan suhu loteng sebesar 3,4◦C. CLPHP dengan etanol FR 55% telah terbukti bekerja lebih baik pada masukan panas rendah untuk pengurangan suhu. CLPHP dengan air FR 70%, di sisi lain, telah terbukti memiliki kinerja pengurangan suhu yang lebih besar dalam input panas sedang dan tinggi. ......A rapid urbanization especially in tropical regions have becoming a serious concern recently. A “sprawl” type development has been found in several countries whereas low-density residential and commercial development are expanding into the outer edges of cities and towns. Due to these circumstances, most of the green spaces will eventually degrade causing a phenomenon called Urban Health Island (UHI) and heat stress. Moreover, an increase in urban population will also affect the increase in building construction. Over one third of the total demand of energy consumption required to provide comfortable room condition with cooling, heating and ventilation system, is becoming the building sector’s accountability. An excessive use of air conditioning system in a building could lead to an increase in energy consumption, gas emission and also outdoor air pollution. Since countries in tropical areas have a hot and humid climate, most of the building in that regions require a room conditioning system especially by cooling and dehumidification. Temperature and humidity inside the room depend on how much heat enters the room. This term is called as heat gain, whereas it is mostly coming from a solar radiation that enters through the roof. One of the best ways to reduce heat gain without affecting energy consumption and environment is by using a Closed Loop Pulsating Heat Pipe (CLPHP). In this study, the performance of the CLPHP roofing system was tested using two types of fluids, pure water and pure ethanol. The CLPHP roof system was then compared with the condition when the roof system did not use CLPHP using the experimental method. The results of the experiment showed that at 113 W/m2, the CLPHP roofing system with ethanol FR 55% has the lowest thermal resistance of 0.224 K/W and will provide a 2.4◦C reduction in attic temperatures. At 270 W/m2, the CLPHP roofing system with water FR 70% has the lowest thermal resistance of 0.160 K/W and can give a 3.1◦C reduction in attic temperatures. At 355 W/m2, the CLPHP roofing system with water FR 70% has the lowest thermal resistance of 0.095 K/W and can deliver a 3.4◦C reduction in attic temperatures. CLPHP with ethanol FR 55% has been shown to work better in low heat input for temperature reduction. CLPHP with water FR 70%, on the other hand, has been shown to have greater temperature reduction performance in medium and high heat input.
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Childs, Peter R.N.
Oxford: Butterworth-Heinemann, 2001
536.502 87 CHI p
Buku Teks  Universitas Indonesia Library
cover
New York: John Wiley & Sons, 2000
536.502 87 TEM
Buku Teks  Universitas Indonesia Library
cover
Sharon Hanandi
Abstrak :
Pengembangan pengisian form dalam bentuk digitalisasi adalah salah satu hal yang penting untuk memudahkan pengisian serta pemantauan pengisian form oleh penanggung jawab. Hal ini khususnya diperlukan pada pemantauan suhu cold room di luar jam operasional karena produk rantai dingin merupakan produk yang memiliki persyaratan khusus yang harus dipenuhi sebagai standar, meliputi aturan yang berkaitan dengan pemantauan suhu pada saat penerimaan, penyimpanan, dan pengiriman. Usulan digitalisasi pengisian form pada PT. Anugerah Pharmindo Lestari dilakukan melalui aplikasi “InformU” yang dapat diakses staff security untuk mengisi form dan BRQA (Branch Regulatory and Quality Assurance) untuk me-review hasil pengisian form. Digitalisasi pengisian form pemantauan suhu di luar jam operasional diharapkan dapat membuat pencatatan dan pemantauan suhu menjadi lebih efisien, terintegrasi, dan mudah diakses bagi PT. Anugerah Pharmindo Lestari serta dapat menghindari kemungkinan pencatatan form yang tidak dilakukan secara real time. ......The development of filling out forms in digitized form is one of the important things to facilitate filling and monitoring of forms by the person in charge. This is especially necessary for cold room temperature monitoring outside of operating hours because cold chain products are products that have specific requirements that must be met as standards, including rules relating to temperature monitoring during admission, storage and delivery. Proposed digitization of filling out forms at PT. Anugerah Pharmindo Lestari is carried out through the "InformU" application which can be accessed by security staff to fill out the form and BRQA (Branch Regulatory and Quality Assurance) to review the results of the filled out form. Digitalization of filling out temperature monitoring forms outside of operating hours is expected to make temperature recording and monitoring more efficient, integrated and easily accessible for PT. Anugerah Pharmindo Lestari and can avoid the possibility of recording forms that are not done in real time.
Depok: Fakultas Farmasi Universitas Indonesia, 2023
PR-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Wahidun Adam
Abstrak :
Alat berat membutuhkan kualitas dan kehandalan yang tinggi untuk menunjang produktivitas dan kepuasan pelanggan. Konstruksi utama rangka pada alat berat terbuat dari material baja pelat dan coran yang disambungkan melalui proses pengelasan Gas Metal Arc Welding (GMAW). Kondisi saat ini, produsen belum melihat tegangan sisa dari proses manufaktur sebagai pertimbangan khusus terhadap kualitas produk. Pada penelitian ini, pelat baja SM490 berukuran 200x100 mm disambungkan dengan pengelasan robot GMAW secara butt joint single V 45. Kawat las AWS A5.18-05 ER70S-G berdiameter 1,4 mm digunakan dengan polaritas DCEP bersama gas pelindung CO. Masukan panas, tebal spesimen, dan perlakuan pengelasan divariasikan untuk mengetahui efeknya terhadap tegangan sisa dan sifat mekanik yang dihasilkan. Tegangan sisa diukur tanpa merusak menggunakan mesin portabel berbasis X-Ray Diffraction (XRD). Nilai kekerasan diuji dengan mesin uji keras Microvickers, kekuatan tarik diuji dengan mesin Universal Testing Machine (UTM), serta struktur mikro diamati dengan mikroskop optik strereo dan Electron Probe Micro Analyzer (EPMA). Hasil pengujian menunjukkan kenaikan masukan panas sebesar 350 J menit meningkatkan tegangan sebesar 50-90 MPa pada arah x. Peningkatan ketebalan hingga 30 mm, tidak memberikan perbedaan tegangan sisa yang signifikan. Namun, tebal 40 mm, tegangan sisa justru turun 250 MPa. Ketebalan spesimen hingga 40 mm memberikan penurunan tegangan sisa arah y hingga 400 MPa. Proses gerinda memberikan tegangan sisa tarik hingga 800 MPa lebih tinggi dari tegangan sisa spesimen 2 (tanpa perlakuan). Penambahan preheat dan postheat 150oC tidak memberikan efek terhadap tegangan sisa. Proses gerinda menurunkan tegangan sisa hingga 480 MPa. Hanya jet chisel yang konsisten memberikan tegangan sisa kompresi hingga 480 MPa pada arah x dan y. Kenaikan masukan panas hingga 350 J menit menyebabkan nilai kekerasan HAZ dan logam las turun hingga 50 HB. Ketebalan spesimen hingga 30 mm, cenderung meningkatkan kekerasan hingga 30 HB. Perlakuan preheat dan postheat mengurangi nilai kekerasan hingga 10 HB. Kebalikan dari itu, perlakuan jet chisel mampu meningkatkan kekerasan hingga 12 HB, terutama pada kampuh las. Berbagai variasi masukan panas, ketebalan, dan perlakuan pengelasan tidak memberikan perbedaan yang signifikan kekuatan tarik. Peningkatan ketebalan hingga 40 mm cenderung menurunkan kekuatan hingga 70 MPa. Perlakuan jet chisel memberikan tegangan sisa dan sifat mekanik paling optimal di antara preheat, postheat, dan gerinda.
Heavy equipment requires high quality and reliability to support productivity and customer satisfaction. The main frame construction on the machine is made of steel plate and castings which are connected through the Gas Metal Arc Welding (GMAW) process. Current conditions, manufacturers have not seen the residual stress from the manufacturing process as a special consideration to product quality. In this study, a 200x100 mm SM490 steel plate was connected by GMAW robots welding with a single V 45 butt joint. AWS A5.18-05 ER70S-G welding wire 1.4 mm in diameter is used with DCEP polarity and CO2 protective gas. Heat input, specimen thickness, and welding treatment are varied to determine their effect on residual stresses and mechanical properties. Residual stress is measured using a non destructive portable machine based on X-Ray Diffraction (XRD). Hardness values were tested with Microvickers Hardness Tester, tensile strengths with Universal Testing Machine (UTM), and microstructure was observed with optical strereomicroscope and Electron Probe Micro Analyzer (EPMA). The test results show an increase in heat input of 350 J / min increases the stress by 50-90 MPa in the x direction. Increased thickness up to 30 mm, does not provide a significant residual stress difference. However, 40 mm thick, the residual stress would drop 250 MPa. Specimen thicknesses of up to 40 mm provide a reduction in the residual stress in the y direction up to 400 MPa. The grinding process provides tensile residual stresses of up to 800 MPa higher than specimen 2 residual stress (without treatment). The addition of preheat and postheat 150oC had no effect on residual stress. The grinding process reduces the residual stress to 480 MPa. Only jets chisel that consistently provide compression residual stresses of up to 480 MPa in the x and y directions. Increase in heat input up to 350 J/min causes the HAZ hardness value and weld metal to decrease to 50 HB. Specimen thickness up to 30 mm, tends to increase hardness up to 30 HB. The preheat and postheat treatments reduce the value of hardness to 10 HB. In contrast, jet chisel treatment can increase the hardness to 12 HB, especially in weld joints. Various variations in heat input, thickness, and welding treatment do not provide a significant difference in tensile strength. Increasing thickness up to 40 mm tends to reduce strength up to 70 MPa. Jet chisel treatment provides the most optimal residual stress and mechanical properties between preheat, postheat and grinding.
Depok: Fakultas Teknik Universitas Indonesia, 2019
T55180
UI - Tesis Membership  Universitas Indonesia Library
cover
Tania Paramita
Abstrak :
Latar belakang: Pengukuran suhu tubuh sebenarnya (core body temperature) tidak lazim dilakukan pada anak karena invasif dan sulit, sehingga pengukuran suhu aksila dan membran timpani lebih disukai. Namun sampai saat ini ketepatan hasil pengukuran suhu membran timpani dan aksila masih diperdebatkan. Tujuan: Membandingkan ketepatan hasil pengukuran suhu membran timpani dan aksila dengan rektal, mengetahui metode terbaik pengukuran suhu tubuh, dan cut off demam pada anak berdasarkan masing-masing metode pengukuran suhu. Metode: Penelitian diagnostik potong lintang pada anak demam berusia 6 bulan ? 5 tahun yang dipilih secara konsekutif di Poliklinik Anak, IGD Anak, dan Ruang Perawatan Anak Gedung A RSCM antara bulan Desember 2014 ? Januari 2015. Hasil: Dengan cut off demam suhu aksila 37,4oC dan membran timpani 37,6oC didapatkan sensitivitas 96% (IK 95% 0,88-0,98) dan 93% (IK 95% 0,84-0,97), spesifisitas 50% (IK 95% 0,47-0,84) dan 50% (IK 95% 0,31-0,69), NDP 90% (IK 95% 0,81-0,95) dan 85% (IK 95% 0,75-0,91), NDN 83% (IK 95% 0,61-0,94) dan 69% (IK 95% 0,44-0,86). Cut off optimal demam suhu membran timpani dan aksila pada penelitian ini adalah 37,8oC (AUC 0,903 dan 0,903). Simpulan: Hasil pengukuran suhu aksila sama baik dengan membran timpani dalam mendeteksi demam dan dapat digunakan dalam praktik klinis sehari-hari maupun di rumah. Dengan cut off demam 37,8oC didapatkan sensitivitas 81% dan 88%, spesifisitas 86% dan 73%, NDP 95% dan 91%.
Background: Core body temperature measurement is not common in pediatric population because it is invasive and difficult. Therefore tympanic and axillary temperature measurement are prefereble but their accuracy still debated. Objective: To compare the accuracy of axillary and tympanic temperature to rectal temperature in children with fever and measure the cut off point for fever based on each temperature measurement method. Methods: A cross-sectional diagnostic study was conducted among children age 6 months ? 5 years which was selected consecutively at Pediatric Out-patient clinic, Pediatric emergency unit, and the in-patient wards in building A RSCM from December 2014 to January 2015. Results: With the cut off for fever on axilla 37,4oC and tympanic membrane 37,6oC the sensitivity was 96% (95% CI 0,88-0,98) and 93% (95% CI 0,84-0,97), specificity 50% (95% CI 0,47-0,84) and 50% (95% CI 0,31-0,69), NDP 90% (95% CI 0,81-0,95) and 85% (95% CI 0,75-0,91), NDN 83% (95% CI 0,61-0,94) and 69% (95% CI 0,44-0,86). Optimal cut off of tympanic membrane and axilla temperature was 37,8oC (AUC 0,903 dan 0,903). Conclusions: Axillary temperature measurement is as good as the tympanic membrane temperature measurement and can be used at the daily clinical practice or at home. By increasing the optimum fever cut off point for axilla temperature and tympanic membrane to 37,8oC, we found sensitivity 81% and 88%, specificity 86% and 73%, NDP 95% and 91%.
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2015
T58925
UI - Tesis Membership  Universitas Indonesia Library
cover
Tri Kowara
Abstrak :

ABSTRAK
Sebagian besar konstruksi jalan di Indonesia dibangun dengan menggunakan struktur perkerasan lentur, yaitu struktur yang menggnnakan lapisan aspalan sebagai lapisan permukaan Lapisan aspalan itu terdiri dari campuran aspal dengan agregat yang menjadi satu dan berfungsi sebagai perisai dari kekuatan konstruksi tersebut. Oleh karena itu diperlukan aspal yang memiliki daya tahan kuat terhadap hal-hal yang dapat merusak konstruksi seperti pengaruh cuaca, aliran air, panas matahari, beban kendaraan dan sebagainya. Aspal adalah suatu bahan yang thermoplastik yaitu akan menjadi lunak jika dipanaskan dan menjadi keras jika didinginkan atau dengan kata lain sifat fisik aspal sangat ditentukan oleh kondisi temperatur yang dialaminya. Kondisi iklim di Indonesia yang tropis dimana temperatur lapangan dapat berkisar antara 40°C sampai dengan 55°C, menuntut daya tahan aspal terhadap temperatur yang tinggi. Untuk itu diperlukan suatu penelitian mengenai perilaku aspal berhubungan dengan sifatnya yang thermoplastik atau kepekaan aspal terhadap temperatur yang terjadi. Salah satu metoda yang dapat dilakukan adalah dengan mengetahui nilai Indeks Penetrasi yang diperoleh dengan menggunakan formula Pfeiffer dan Van Doormaal sehingga dapat diketahui tingkat kepekaan aspal terhadap temperatur. Penelitian yang dilakukan terdiri dari Pemeriksaan Titik Lembek, Pemeriksaan Peneuasi untuk Temperatur yang bervariasi dan Pemeriksaau Kehilangan Berat. Penelitian dilakukan di Laboratoriurn Perkerasan Jalan & Survey FTUI dengan mengacu pada standar ASTM dan AASHTO uutuk penguj ian Aspal. Serangkaian pengujian dan analisa yang dilakukan dapat menyimpulkan tingkat kepekaan dari aspal yang dilakukan pemeriksaan dan membuktikan bahwa pemakaian bahan aditif atau memodiiikasi aspal Cement menjadi aspal Polymer dan aspal I-IBA telah mengurangi tingkat kepekaan aspal terhadap Temperatur.
Depok: Fakultas Teknik Universitas Indonesia, 1997
S34676
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abstrak :
Penentuan konduktivitas kalor pada AUKK (Alat Uji Konduktivitas Kalor) telah banyak dilakukan dengan metode ogawa seiki. Kali ini akan dicoba pendekatan lain, yaitu dengan menentukan bcr}a-temperatur di benda uji dengan pendekatan grafik. Sehingga dengan demikian nilai Konduklivitas Termal bisa didapat dengan metode yang berbeda berdasarkan perbedaan perbedaan temperatur tersebut.

Pengujiaan dilakukan dengan benda uji polyurethane. Tetapi setelah diketahui data- data temperatumya lemyata alat ini tidak akurat menguji benda yang memiliki konduktivitas termal rendah.

Pendekatan yang dilakukan adalah dengan melihat kecenderuugan aliran kalor setiap benda uji. Sehingga dari kecenderungan itu akan didapatkan beda temperatur pada benda uji yang merupakan persamaan yang menunjukkan hubungan antara benda uji dan temperalur didekatnya.
Fakultas Teknik Universitas Indonesia, 2004
S37469
UI - Skripsi Membership  Universitas Indonesia Library
cover
Tarigan, Akor
Abstrak :
Rancang bangun pengendali temperatur pada chamber simulasi Inkubator bayi yang diajukan pada tugas akhir ini adalah sistim pengendali menggunakan komponen Rele sebagai penggerak akhir untuk heater dan komponen elektronik untuk mengontrol bekerjanya rele tersebut,dan Sensor temperatur digunakan NTC (Negative Temperature Coeficient). Stabilitas temperatur pada chamber simulasi dapat diperoleh sesuai dengan besaran setpoint Dengan menggunakan blower sebagai sirkulasi panas akan diperoleh respon time cepat pada temperatur yang dinginkan. Harga konduktivitas panas dengan menggunakan blower lebih baik dibandingkan tanpa blower, dimana : Dengan blower = 10 menit ; H = 30.6 (w/cmzoC) Tanpa blower = 16 menit ; H = 19.15(w/cm*’C) Sebagai chamber simulasi dibuat dari pelat dan acrylic berukuran P = 29 Cm,L = 11 Cm, T = 16 Cm dan element pemanas berupa lampu pijar 220 Volt 100 watt serta sebuah blower 12Vdc/4w.
Depok: Fakultas Teknik Universitas Indonesia, 1996
S38870
UI - Skripsi Membership  Universitas Indonesia Library