Ditemukan 10 dokumen yang sesuai dengan query
cover
Damawidjaya Biksono
Abstrak :
Penelitian aliran campuran udara-air di dalam pipa spiral horizontal telah dilakukan. Efek aliran di dalam pipa spiral melihat letak lokasi perubahan gelembung udara. Tujuan dari studi ini memperjelas karakteristik aliran campuran udara-air yang mengalir di dalam pipa spiral horizontal. Pengukuran kerugian tekanan dan letak lokasi penyebaran gelembung udara-air pada penampang melintang pipa masing-masing digunakan manometer dan digital video. Hasil koefisien gesek campuran udara-air lebih besar dibandingkan koefisien gesek pada air dan letak posisi udara dapat dijelaskan.
Depok: Fakultas Teknik Universitas Indonesia, 2005
T16149
UI - Tesis Membership  Universitas Indonesia Library
cover
Edo Widi Virgian
Abstrak :
Kebutuhan terhadap refrigeran alternatif untuk sistem refrigerasi semakin meningkat. Salah satu refrigerant alternatif yang umum digunakan terutama dalam keperluan sistem tata udara pemukiman adalah propana. Propana atau R290 memiliki keunggulan karena selain mudah didapatkan, juga memiliki sifat properti termodinamika dan perpindahan kalor yang cukup baik antara lain viskositas dinamik serta rapat massa jenis yang kecil dan stabil sehingga memiliki kemampuan penyerapan kalor yang baik meskipun membutuhkan perhatian terutama di dalam penannganan potensi bahaya ledakan. Salah satu metode yang umum digunakan di dalam analisis performa sistem refrigerasi adalah aliran dua fasa. Perhitungan korelasi perhitungan tekanan dilakukan dengan menggunakan basis data yang berasal dari penelitian Pamitran, et. al (2011) yang terdiri dari fluks kalor q = 5-20 kW/m2, G = 50-180 kg/m2. s; temperatur saturasi 0-11 oC, dan fraksi massa atau kualitas uap 0-1. Hasil menunjukkan bahwa fluks laju aliran massa, fluks kalor, dan bilangan Reynolds fasa campuran berbanding lurus terhadap penurunan tekanan aktual, persamaan korelasi Friedel (1979) memberikan nilai yang lebih akurat untuk memprediksi penurunan tekanan dengan nilai MAE (Mean Absolute Error) sebesar 59,12 % dan regim aliran yang terbentuk adalah regim aliran plug (kantong udara), slug, dan transition menuju wavy-annular menurut peta pola aliran Zhuang, et.al (2016). ......The need for alternative refrigerants for refrigeration system is increasing. One of the alternative refrigerants that commonly used, especially in residential air conditioning systems, is propane. Propane or R290 has the advantage because in addition to being easy to obtain, it also has good thermodynamic properties and heat transfer, including small and stable dynamic viscosity and density so that it has good heat absorption ability although it requires attention, especially in potential explosion hazards. One of the methods that commonly used in refrigeration system performance analysis is two-phase flow. Calculation of the correlation of pressure drop is carried out using a database derived from Pamitran, et. al (2011) which consists of parameters range such as heat flux q = 5-20 kW/m2, G = 50-180 kg/m2. S, saturation temperature 0-11 oC, and mass fraction or vapor quality 0-1. The results show that the mass flow rate flux and heat flux are directly proportional to the actual pressure drop with a greater effect of mass flow rate flux and Friedel's (1979) correlation equation provides a more accurate value for predicting pressure drop with MAE (Mean Absolute Error) value of 59,12 %. On the flow pattern map of Zhuang, et.al (2016) a plug-slug and transition flow condition to wavy-annular is formed.
Depok: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Lazuardy Akbar
Abstrak :
Sebuah experiment telah dilakukan untuk penggunaan refrigeran ramah lingkungan menjadi kebutuhan manusia. Dalam percobaan aliran mendidih R-22, diameter pipa konvensional 7,6 mm digunakan. Variasi fluks panas dari 5,9 kW / m2 hingga 25,04 kW / m2, fluks massa 282 kg / m2.s hingga 630 kg / m2.s, dan suhu saturasi dari -0,42 ° C hingga 11,97 ° C untuk hasil R- 22. Hasil tersebut dipengaruhi oleh penurunan tekanan di fluks massa, fluks panas dan temperature saturasi. Adapun perpindahan kalor dipengaruhi oleh fluks kalor dan temperatur, sedangkan fluks massa menunjukkan tidak ada perubahan dalam perpindahan kalor untuk nilai R-22. Dalam rangka untuk mencari dan membandingkan hasil, Computational Fluid Dynamics (CFD) telah menjadi pendekatan untuk desaindan evaluasi kinerja. Pada penelitian ini, simulasi numerik untuk internal pipa dilakukan dengan menggunakan model Eulerian dengan paket CFD, ANSYS Fluent 12.1. Turbulensi di fase cair dan gas dijelaskan menggunakan model k-ε. Parameter hidrodinamika global seperti fluks masa dan kecepatan cairan telah diteliti untuk berbagai dangkal uap dan kecepatan gas, dengan simulasi 3D. Selain itu, studi geometri dan skala pengaruh pada pipa horisontal telah dipertimbangkan. Hasil penelitian menunjukkan fluks massa dan fluks panas memiliki efek signifikan pada parameter hidrodinamik, yang dapat menyebabkan efek besar pada hasil penurunan tekanan. Perhitungan numerik dengan sistem aliran dua fase gas-cair telah dilakukan untuk mengetahui pengaruh penurunan tekanan, perbedaan suhu, dan massa penurunan fluks pada karakteristik hidrodinamika fluks massa yang berbeda dan fase atau jenis arus. Hasil ini diproduksi mengungkapkan bahwa CFD memiliki potensi yang sangat baik untuk mensimulasikan dua-fase sistem aliran. ...... An experiment has been done previously to the use of environmentally friendly refrigerants into human needs. In the experiment of boiling flow conditions, R-22 is done in a conventional pipe diameter of 7.6 mm. Variation of heat flux of 5.9 kW / m2 to 25.04 kW / m2, the mass flux of 282 kg / m2.s up to 630 kg / m2.s, and the saturation temperature of -0.42 ° C to 11.97 ° C for R-22.The results are influenced by the pressure drop in the mass flux, heat flux and temperature saturation. As for the heat, transfer is affected by the heat flux and temperature saturation, whereas the mass flux showed no change in the heat transfer value for R-22. In order to find and compare results, Computational Fluid Dynamics (CFD) has become an approach for design, scale-up and performance evaluation. In the present work, numerical simulations for internal-pipe were performed using the Eulerian model with CFD package, ANSYS Fluent 12.1. The turbulence in the liquid and vapor phase are described using the k-ε model. Global hydrodynamic parameters like mass flux and liquid velocity have been investigated for a range of superficial vapor and gas velocities, only with 3D simulations. Moreover, the study of geometry and scale influence on the horizontal pipe have been considered. The results suggest mass flux and heat flux have significant effects on the hydrodynamic parameters, which may lead to substantial effects on the pressure drop results. Numerical calculations with gas-liquid two-phase flow system have been carried out to investigate the effect of mass flux and heat flux on the hydrodynamic characteristics of two-phase flows. These produced results reveal that CFD have excellent potential to simulate two-phase flow system.
Depok: Fakultas Teknik Universitas Indonesia, 2016
S63202
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Hanan Thomas
Abstrak :
Dalam penilitian ini akan dibahas tentang penurunan tekanan yang terjadi pada aliran evaporasi dua fasa pada kanal mini horizontal dengan menggunakan refrigeran alternatif R-290. Pada penilitian ini akan dicari nilai prediksi penurunan tekanan secara teoritis yang didapatkan melalui pendekatan Lockhart-Martinelli dan Chisolm dengan bantuan program Matlab. Program Fluent juga digunakan untuk mendapatkan prediksi penurunan tekanan aliran evaporasi dua fasa berdasarkan simulasi CFD. Hasil dari prediksi tersebut kemudian akan dibandingkan dengan nilai penurunan tekanan dari hasil pengukuran menggunakan alat uji refrigerasi dengan sistem pemutaran tertutup untuk mendapatkan nilai deviasi untuk masing-masing pendekatan teoritis dan dari hasil simulasi CFD.
This study will examine the pressure drop for two phase flow boiling in horizontal mini channel using refrigerant R-290. This study will look into obtaining theoretical pressure drop prediction using Lockhart-Martinelli and Chisolm correlations with the help of Matlab software. The Fluent software will also be used to obtain the two phase flow boiling pressure drop prediction using CFD simulation. These prediction results will then be compared to the pressure drop from experiment data using closed loop refrigeration system experiment apparatus to obtain the deviation values for each theoretical correlations and from the CFD simulation.
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50936
UI - Skripsi Open  Universitas Indonesia Library
cover
Samuel Agustinus Adam
Abstrak :
[Pada paper ini void fraction dari R-290 di investigasi. Penggunaan R-290 ditujukan untuk menggantikan R-22, dikarenakan R-22 memiliki nilai ODP (Ozone Depletion Potential) sebesar 0.05 dan nilai GWP (Global Warming Potential) sebesar 1700. Nilai void fraction dibutuhkan karena berhubungan dengan prediksi nilai dari jatuh tekanan, yaitu pada jatuh tekanan akibat akselerasi. Sehingga, merupakan suatu kebutuhan untuk melakukan studi komprehensif mengenai void fraction pada aliran didih dua fase pada pipa konvensional berdiameter dalam 7.6 mm. Data primer didapatkan dengan melakukan eksperimen pada kondisi: Fluida kerja R-290, pipa horizontal berdiameter dalam 7.6 mm, temperatur saturasi pada rentang 5 hingga 15ºC, fluks kalor pada rentang 9 hingga 20 kW/m2 dan fluks massa pada rentang 300 hingga 420 kg/m2.s. Hasil jatuh tekanan eksperimen yang di dapatkan kemudian dibandingkan dengan jatuh tekanan prediksi., In this present paper the void fraction of R-290 was investigated. The use of R-290 is to replace R-22, since R-22 has 0.05 Ozone Depletion Potential (ODP) and 1700 Global Warming Potential (GWP). The relevancy to obtain the void fraction was related to predict the value of pressure drop, especially accelerational pressure drop. Therefore, it is a necessity to conduct a comprehensive study about void fraction in two-phase flow boiling in conventional pipe with 7.6 mm inner diameter. To obtain the primary data, the experiment was conducted with the experimental conditions of R-290 working fluid, 7.6 mm inner diameter horizontal tube, 5 to 15ºC saturation temperature, 9 to 20 kW/m2 heat flux, and 300 to 420 kg/m2.s mass flux. The recent results of pressure drop were compared to some existing method of pressure drop calculations]
2015
T44149
UI - Tesis Membership  Universitas Indonesia Library
cover
Washington: Hemisphere Pub., 1981
620.106 TWO
Buku Teks  Universitas Indonesia Library