Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Abstrak :
The book provides a detailed, up-to-date account of the basics, the technology, and the clinical use of ion beams for radiation therapy. Theoretical background, technical components, and patient treatment schemes are delineated by the leading experts that helped to develop this field from a research niche to its current highly sophisticated and powerful clinical treatment level used to the benefit of cancer patients worldwide. This book consists of related chapters. It is a common achievement by 76 experts from around the world. Their expertise reflects the diversity of the field with radiation therapy, medical and accelerator physics, radiobiology, computer science, engineering, and health economics. The book addresses a similarly broad audience ranging from professionals that need to know more about this novel treatment modality or consider to enter the field of ion beam therapy as a researcher. However, it is also written for the interested public and for patients who might want to learn about this treatment option.
Berlin : Springer, 2012
e20425204
eBooks  Universitas Indonesia Library
cover
Fitriyani
Abstrak :
Treatment Planning System (TPS) merupakan kunci dalam keberhasilan pengobatan radioterapi eksternal, yang secara langsung berdampak pada kualitas rencana perawatan dan ketepatan perhitungan dosis dalam perencanaan. Keluaran dari hasil perencanaan pada TPS berupa kurva DVH. DVH menjadi acuan dalam melihat penyebaran dosis pada target maupun organ sehat. Dalam penelitian ini, dilakukan perbandingan antara DVH hasil dari TPS dengan DVH hasil dari perhitungan analitik. Perbandingan DVH dilakukan dengan langkah awal membuat objek simulasi berupa fantom virtual menggunakan program Matlab dengan berbagai bentuk geometri, yaitu bola, kubus, dan silinder. Perencanaan terhadap objek simulasi dilakukan dengan menggunakan TPS Eclispe. Dari hasil perencanaan dengan menggunakan TPS Eclispe dan hasil perhitungan analitik, diperoleh perbedaan nilai tertinggi terdapat pada objek simulasi kubus untuk penyinaran 1 lapangan, dan pada objek simulasi silinder pada penyinaran 4 lapangan. Sementara pada perbandingan nilai Dmaks dan Dmin, perbedaan terbesar terdapat pada nilai Dmin dengan penyimpangan tertinggi berada pada objek simulasi kubus dan silinder. Tidak terdapat nilai yang sama pada perencanaan ini untuk semua objek simulasi.
Treatment Planning System (TPS) is the key to success of external radiotherapy treatment, which directly impacts the quality of treatment planning and the accuracy of dose calculation in planning. The output of the planning results at the TPS consists of the DVH curve. DVH is the target in looking at the distribution of doses to target and organ at risk. In this study, an experiment was conducted between DVH results from TPS and DVH results from analytical calculation. DVH comparison is done with the initial step of making simulation objects using virtual phantoms using the Matlab program with various geometric shapes, namely are sphere, cube, and cylinder. Planning of the simulation object is done using Eclispe TPS. From the results of planning using TPS Eclispe and analytical calculation results, the value of the assessment of the cube simulation object is obtained for 1 field illumination, and for cylinder simulation objects in 4 fields irradiation. While in determining the value of Dmax and Dmin, the biggest difference is the value of Dmin with the highest deviation in the comparison object of the cube and the cylinder. There are no equal values in this plan for all simulation objects.
Depok: Universitas Indonesia, 2019
T55297
UI - Tesis Membership  Universitas Indonesia Library
cover
Risayanti
Abstrak :
Telah dilakukan pengukuran PDD, faktor keluaran dan profil dosis pada lapangan kecil dengan teknik penyinaran setengah lapangan menggunakan Film Gafchromic EBT3, bilik ionisasi Exradin A16, dan detektor matriks PTW 2D-Array 729. Tujuan dari penelitian ini adalah mengetahui karakteristik berkas foton lapangan kecil menggunakan teknik penyinaran setengah lapangan, dan membandingkan hasil pengukuran dengan data referensi yang menggunakan teknik penyinaran lapangan penuh full-beam . Evaluasi pengukuran PDD dilakukan dengan menentukan nilai dmax dan menghitung nilai TPR20,10. Profil dosis dianalisa berdasarkan nilai FWHM dan penumbra. Hasil pengukuran menunjukkan bahwa nilai dmax, TPR20,10, FWHM, penumbra, dan faktor keluaran menghasilkan pola yang sama dengan hasil pengukuran teknik penyinaran lapangan penuh full-beam . Deviasi FWHM terbesar menggunakana Film Gafchromic EBT3 dan Exradin A16 adalah -10.99 dan -33.14 terjadi saat pengukuran pada luas lapangan 0.8 0.8 cm2 dan kedalaman 1.5 cm, sedangkan deviasi FWHM terbesar menggunakan detektor matriks PTW 2D-Array 729 adalah -46.25 terjadi saat pengukuran pada luas lapangan 1.6 1.6 cm2 dan kedalaman 1.5 cm. Persentase deviasi faktor keluaran terbesar adalah -54.22 yaitu saat pengukuran menggunakan detektor matriks PTW 2D-Array 729 pada kondisi pengukuran luas lapangan 0.8 0.8 cm2 dan kedalaman 10 cm. ...... PDD measurements, output factor, and dose profile have been conducted in small field with half beam irradiation technique using Gafchromic EBT3 Film, Exradin A16 ionization chamber, and PTW 2D Array 729 matrix detector. This study was aimed to determine the characteristic of small field photon beam using half beam irradiation technique and compare the measurement results with reference data that performed full beam irradiation technique. PDD measurements evaluation has been done by determining the value of dmax and calculate the TPR20,10 value. Dose profile was analyzed based on the value of FWHM and penumbra. The measurement results showed that the value of dmax, TPR20,10, FWHM, penumbra, and output factor have similar pattern with the measurement results of full beam irradiation technique. The highest FWHM deviation value that can be obtained using Gafchromic EBT3 Film and Exradin A16 are 10.99 and 33.14 occurred when measurements were conducted in the field size of 0.8 0.8 cm2 and depth of 1.5 cm. The highest deviation percentage of output factor that can be obtained using PTW 2D Array 729 matrix detector is 54.22 occured in the field size of 0.8 0.8 cm2 and depth of 10 cm.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2016
S66624
UI - Skripsi Membership  Universitas Indonesia Library