Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 284 dokumen yang sesuai dengan query
cover
Casey , T. J.
Chichester: John Wiley & Sons, 1996
628.162 CAS u
Buku Teks  Universitas Indonesia Library
cover
Schroeder, Edward D.
New York: McGraw-Hill, 1977
628.16 SCH w
Buku Teks  Universitas Indonesia Library
cover
Fair, Gordon Maskew
New York : John Wiley & Sons, 1968
628.1 FAI w
Buku Teks  Universitas Indonesia Library
cover
New York, N.Y.: VCH, 1996
628.166 CHE
Buku Teks  Universitas Indonesia Library
cover
Devi Dwiyanti Suryono
"Limbah domestik merupakan salah satu pencemar yang sangat berpotensi untuk menimbulkan pencemaran lingkungan, terutama limbah domestik yang berasal dari tangki septik. Beberapa penelitian menunjukkan bahwa kota-kota besar di Indonesia sudah tercemar oleh buangan toilet (black Water), yang diperkirakan 70-80% dari limbah ini langsung mencemari air tanah dangkal.
Berdasarkan kenyataan tersebut kebutuhan fasilitas pengolahan limbah tangki septik harus diperhatikan, karena kualitas efluen hasil pengolahan di dalam tangki septik ternyata masih berpotensi untuk mencemari lingkungan. Oleh karena itu, diperlukan suatu alternatif penyelesaian untuk memperbaiki kualitas efluen limbah tangki septik.
Penelitian pengaruh bahan starter terhadap efektivitas pengolahan limbah tangki septik ini dilakukan sebagai alternatif untuk menyelesaikan masalah pengolahan limbah tangki septik. Dengan penambahan bahan starter, berarti ada penambahan sejumlah mikroorganisme ke dalam sistem pengolahan limbah tangki septik yang bertujuan untuk meningkatkan efektivitas pengolahannya.
Tujuan penelitian ini adalah untuk mengetahui pengaruh bahan starter M-Bio dan isi rumen terhadap efektivitas penurunan kadar parameter COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli, serta untuk membandingkan pengaruh kedua bahan starter tersebut dalam berbagai variasi dosis.
Hipotesis yang diajukan dalam penelitian ini adalah:
1. Penambahan bahan starter M-Bio dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap parameter COD, P043- N03-, N02-, padatan tersuspensi, dan E. coli,
2. Penambahan bahan starter isi rumen dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap parameter COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli.
Penelitian eksperimental dilakukan dalam skala laboratorium dengan rancangan penelitian acak lengkap yang disusun secara faktorial, yang dilakukan di Laboratorium Lingkungan, FTUI. Pengamatan dilakukan dengan interval waktu pengamatan 8 jam, yaitu 0, 8, 16, 24, 32, 40, dan 48 jam, serta pengamatan dilakukan hingga 72 dan 96 jam. Variasi dosis bahan starter,yakni M-Bio dan isi rumen adalah 2,5 ml/L, 5 ml/L, dan 7,5 ml/L, kemudian setiap pengamatan dibandingkan terhadap kontrol. Sampel limbah tangki septik diambil dari asrama mahasiswa UI, Depok. Parameter utama yang diukur adalah COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli. Data hasil pengamatan dianalisis menggunakan uji statistik ANOVA, dan rumus kinetika reaksi biokimia M-Bio dan isi rumen.
Berdasarkan hasil penelitian ternyata bahan starter M-Bio meningkatkan efektivitas pengolahan limbah tangki septik yang ditunjukkan dengan penurunan bermakna terhadap konsentrasi parameter COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli. Sedangkan bahan starter isi rumen tidak dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap parameter COD, PO43-, N03-, NO2-, padatan tersuspensi, bahan starter isi rumen hanya dapat meningkatkan efektivitas penurunan parameter E. coli.
Perhitungan konstanta kinetika reaksi biokimia M-Bio menghasilkan laju penguraian bahan organik (rsu) antara 6,7552-90,4693 mg/L/jam, dan pertumbuhan bersih mikroorganisme antara 0,0852-0,4011 sel/jam. Sedangkan, perhitungan konstanta kinetika reaksi biokimia isi rumen menghasilkan laju penguraian bahan organik (rsu) antara 1,6735-10,6951 mg/L/jam, dan pertumbuhan bersih mikroorganisme antara 0,0078-0,0852 sel/jam.
Kesimpulan dari penelitian ini adalah:
1. Penambahan bahan starter M-Bio dapat meningkatkan efektivitas pengolahan limbah tangki septik yang ditunjukkan oleh penurunan terhadap konsentrasi parameter COD, P043-, N03-, N02-, padatan tersuspensi, dan E. coli.
2. Penambahan bahan starter M-Bio memberikan tingkat efisiensi penurunan konsentrasi parameter COD sebesar 83,06%, P043- sebesar 86,76%, N03- sebesar 65,14%, N02- sebesar 73,40%, padatan tersuspensi sebesar 71,15%, dan E. coli sebesar 83,78%.
3. Penambahan bahan starter M-Bio pada dosis 5 ml/L menunjukkan tingkat penurunan yang paling tinggi dibandingkan dosis lainnya pada parameter COD, P043-, N03-, N02-, dan padatan tersuspensi, sedangkan tingkat penurunan parameter E. coli yang paling tinggi ditunjukkan oleh bahan starter M-Bio dosis 7,5 ml/L.
4. Penambahan bahan starter isi rumen tidak dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap konsentrasi parameter COD, P043-, N03-, NO2-, padatan tersuspensi, tetapi hanya efektif untuk menurunkan jumlah E. coli.
5. Laju Pertumbuhan bersih mikroorganisme (µ) dan laju penguraian substrat (rsu) pada pengolahan limbah tangki septik dengan dosis 5 ml/L adalah µ = 0,4011/jam dan rsu = 90,4693 mg/L/jam.

Starter Influence on Domestic Wastewater Treatment Affectivity (A Case Study on Septic Tank Wastewater of Indonesia University Dormitory, Depok) Domestic wastewater is one of the pollutants that caused environmental pollution, especially septic tank wastewater. The surveys show that some of city of Indonesia has been polluted by septic tank wastewater (black water), that estimated 70-80% polluted directly the ground water.
Based on this condition, the necessity of septic tank wastewater treatment facility should be attended, because the effluent quality as result of a treatment in septic tank still have chance to pollute the environment. So that, the solving alternative is needed to make septic tank wastewater effluent quality better. This research about starter influence on septic tank wastewater treatment affectivity was conducted as an alternative to solve septic tank wastewater treatment problem. By the starter addition, it means there are a number of microorganisms were added into septic tank wastewater treatment system to increase that treatment affectivity.
The aim of this research is to understand the starter influence of M-Bio and paunch manure on removal affectivity of parameters COD, P043 N03, N02-, suspended solid, and E. coil, and to compare the various dose of both of starter influence.
The hypotheses of this research are:
1. The addition of M-Bio starter increase the treatment affectivity of septic tank wastewater on parameters COD, P043-, N03-, N02-, suspended solid, and E. coli
2. The addition of paunch manure starter increase the treatment affectivity of septic tank waste on parameters COD, PO43-, N03-, N02-, suspended solid, and E coli.
The experimental study with factorial testing used complete random design and was conducted in the Environmental Laboratory of Engineering, University of Indonesia. The experiment was conducted with interval time of observation 8 hours, that is 0, 8,16, 24, 32, 40, and 48 hours, and the observation was still conducted until 72 and 96 hours. The various dose of both of starter, that is M-Bio and paunch manure is 2,5 ml/L, 5 ml/L, and 7,5 ml/L, and then each observation was compared with control. Septic tank waste samples were taken from Indonesia University dormitory, Depok. The main parameters that were measured were COD, P043-, N03-, N02-, suspended solid, and E. coli. The data were analyzed using analysis of variance (ANOVA) and standard formula to find kinetic constants of M-Bio and paunch manure biochemical reactions.
The final result of both of starter influenced indicate, that M-Bio starter increase the affectivity of septic tank wastewater treatment on parameters COD, PO43-, NO3-, NO2-, suspended solid, and E. coli. While, paunch manure starter not increase the affectivity of septic tank wastewater treatment on parameters COD, PO43-, NO3-, NO2-, suspended solid, paunch manure starter just can increase parameters E. coli. The calculation for kinetic constant of M-Bio biochemical reactions obtained the result that the rate of decomposition of organic material (rsu) was between 6,7552-90,4693 mg/L/hour, and the net growth rate of microorganism was between 0,0852-0,4011 cells/hour. While, the calculation for kinetic constant of paunch manure biochemical reactions obtained the result that the rate of decomposition of organic material (rsu) was between 1,6735-10,6951 mg/L/hour, and the net growth rate of microorganism was between 0,0078-0,0852 cells/hour.
The conclusions of this study are:
1. M-Bio starter increase the affectivity of septic tank wastewater treatment on parameters COD, PO43-, N03-, NO2-, suspended solid, and E. coli.
2. The removal efficiency of COD result in 83,06%, PO43- = 86,76%, NO3- = 65,14%, N02- = 73,40%, suspended solid = 71,15%, and E. coli = 83,78%.
3. The most effective dose for parameters COD, PO43-, NO3-, NO2-, suspended solid is 5 ml/L. And, the most effective dose for parameter E. coli is 7,5 ml/L.
4. The addition of paunch manure starter can not increase the treatment affectivity of septic tank waste on parameters COD, PO43-, NO3-, NO2-, suspended solid, but paunch manure effectively increase on E. coli.
5. The rate of decomposition of organic material (r) for dose 5 ml/L is 90,4693 mg/L/hour, and the net growth rate of microorganism (µ) is 0,4011 cell/hours. While, The rate of decomposition of organic material (rsu) for dose 7,5 ml/L is 6,7552 mg/L/hour, and the net growth rate of microorganism (µ) is 0,1582 cells/hour."
2001
T7118
UI - Tesis Membership  Universitas Indonesia Library
cover
Ririh Yudhastuti
"Sungai Ciliwung selain berperan dalam urat nadi perdagangan dan pintu pertahanan kota Jakarta. Juga berperan sebagai sumber air minum bagi penduduk yang bertempat tinggal disekitar aliran sungai Ciliwung. Pada saat ini keadaan sungai tersebut cenderung demikian. Dimana penduduk yang berada di kelurahan Manggarai masih mempergunakan air Ciliwung sebagai sumber kehidupan. Selama periode tahun 1983 - 1986 sungai Ciliwung dikatakan tercemar berat akibat buangan limbah domestik, Pabrik dan pencemaran oleh industri kecil sepanjang tepi sungai. Menghadapi masalah tersebut perlu diusahakan suatu teknologi sederhana yang dapat digunakan untuk memperbaiki kualitas air menjadi bersih terutama bagi nasyarakat yang tinggal di sekitar sungai.
Salah satu alternativ pembersihan yang dapat menghasilkan air bersih (dalam hal mikrobiologi) yaitu penggunaan zeolit. Cara ini bisa dilakukan perorangan ataupun bersama-sama dalam waktu relatif singkat untuk menghasilkan air bersih. Zeolit banyak ditemukan di Negara kita dan harganya tidak jauh berbeda dengan pasir, atau bubuk arang aktif, tetapi mempunyai efektifitas yang lebih tinggi dalam adsorpsi kuman-kuman.
Dalam penelitian ini telah dilakukan suatu eksperimen yang menggunakan zeolit alam tanpa diaktifasi tetapi dibuat butiran-butiran agar mudah dimasukkan dalam colum / tabung kaca yang dibawahnya terdapat kran pengatur aliran air, untuk mengetahui dosis dan kecepatan aliran air yang optimum untuk mendapatkan jumlah sisa kuman-kuman dalam sampel air.
Hasil penelitian menunjukkan bahwa pemberian zeolit sangat baik untuk menurunkan jumlah kuman-kuman dalam air limbah domestik sungai Ciliwung. Pemerian zeolit dipengaruhi oleh dosis dan kecepatan aliran air, Yaitu semakin, tinggi dosis yang diberikan makin sedikit sisa kuman demikian pula semakin lambat kecepatan aliran air semakin sedikit sisa jumlah kuman dalam air. Hal ini dikarenakan adsorpsi zeolit terhadap kuman-kuman dalam air membutuhkan waktu dan kontak lebih lama."
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 1993
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Abdullatief
"Air adalah nomor satu lingkungan. Kualitas air dapat dirubah dengan cara diencerkan atau diolah. pH Air dan tanah dapat diperbaiki dengan proses pencucian.
Tujuan penelitian ini adalah untuk mengetahui perubahan pH air dan pH tanah karena adanya pengembangan rawa dengan sistem pencucian (leaching). Selain itu Pula hubungannya dengan penempatan penduduk transmigrasi dan lokal yang membuang limbahnya ke dalam saluran-saluran pematusan sehingga perubahan pH air tidak banyak, karena dicemari oleh limbah domestik dari penduduk tersebut.
Penelitian ini telah dilaksanakan dari, bulan Juni 1987 sampai bulan Desember 1987.
Selanjutnya diteliti juga persepsi masyarakat Karang Agung Hulu terhadap pengaruh perubahan pH air dan pH tanah dalam kaitannya dengan kesuburan dan produktifitas tanaman.
Metodologi yang digunakan untuk mengetahui pH air dan pH tanah adalah dengan pengukuran dan analisis laboratorium serta pengambilan sampel dengan Cara stratified random sampling. Daerah penelitian dibagi atas 4 strata yaitu strata I sepanjang saluran primer I, strata II sepanjang saluran primer II, strata III sepanjang saluran primer IV dan strata IV sepanjang saluran primer III dan V.
Jumlah titik pengukuran pH air dan tanah adalah 22 titik pada.lokasi.yang dikembangkan dan.sebagai pembanding 17 titik di lokasi yang tidak dikembangkan. Untuk analisa laboratorium diambil masing-masing 5 sampel air dan 5 sampel tanah.
Selanjutnya untuk mengetahui persepsi masyarakat tentang pengaruh perubahan pH digunakan pengambilan data dengan kuesioner sebagai instrumen sebanyak 107 responden secara acak (random sampling).
Baku mutu air yang digunakan mengacu kepada:
1. Keputusan Gubernur Kepala Daerah Tingkat 1 Sumatera Selatan No: 407/SK/XI/Tahun 1991,
2. Peraturan Menteri Kesehatan RI No: 173/Men.Kes/Per/ VIII/'77 Tahun 1977,
3. Peraturan Menteri Kesehatan RI No: 01/BIRHUKMAS/11 1975.
4. Baku mutu kesuburan tanah mengacu kepada ketentuan Lembaga Penelitian Tanah Bogor, 1970.
Metoda statistik yang dipakai untuk mengetahui pengaruh pengembangan rawa terhadap pH air dan pH tanah digunakan uji T untuk dua kelompok.
Hasil dari penelitian ini dapat disimpulkan sebagai berikut:
1. Perbedaan yang signifikan pada pH air dan tanah antara daerah sebelum dikembangkan dan setelah dikembangkan, yaitu diperoleh T hitung sebesar: 4,3822 untuk pH air, dan 3,3666 untuk pH tanah.
2. Dari perhitungan di atas dapat kita ketahui bahwa pH pada daerah yang telah dikembangkan adalah lebih tinggi dari daerah yang tidak dikembangkan. Sebagai contoh pH air dari 4,1136 berubah menjadi 4,6277. Sedangkan pH tanah dari 3,7000 berubah menjadi 3,888.
Dari hasil analisa tersebut, dapat diambil kesimpulan bahwa hipotesa satu dan dua adalah terbukti (signifikan).
Dengan demikian, maka hipotesa 1 yang mengatakan ada pengaruh pengembangan rawa pasang surut terhadap pH air dan pH tanah di daerah Karang Agung Hulu terbukti. Perhitungan rata-rata (mean) dari 107 kuesioner diperoleh sebesar 26,168 dari skor tertinggi sebesar 60. Maka dapat disimpulkan bahwa hipotesa 2, yaitu masyarakat di daerah Karang Agung Hulu belum mengetahui akibat perubahan pH air dan pH tanah terhadap kesuburan tanah dan produktifitas tanaman, juga terbukti.

Water is number one of importance in the Environment. The water quality can change due to dilution or treatment. Soil and water pH can improve by the leaching process.
The objectives of this research are as follows:
1. To study the changes of soil and water pH as the result of swamp development through the leaching process and their correlation with the domestic waste from the transmigration and local population.
2. The community perception about the impact of changes of soil and water pH, correlation with the soil fertility and productivity.
The study of impact of the swamp development to the environmental quality at Karang Agung Hulu was carried out from June 1987 until December 1987. The project area was divided into four strata. Stratum I, located on the sides of the Primary Canal I. Stratum II, located on the sides of the Primary Canal II. Stratum III, located on the sides of the Primary Canal IV, and Stratum IV on the sides of the Primary Canals III and V.
In this study is used the incite measurement and laboratory analysis method of pH. Sampling was carried out by stratified random sampling.
Data pH collecting with pH measurement. 22 sample point of soil and water pH were measured at the swamp development area and 17 sample point at the swamp not developed area, as comparison. 5 Soil and water sample are taken for laboratory analysis.
Data collected was conducted by way of observation, interview and questionnaires of 107 respondents. The water quality standard used was issued by the:
1. The South Sumatera Governor Decree No:407/SK/XI/1991,
2. Ministry of Health Decree No: 173/Men.Kes/Per/VIII/1977,
3. Ministry of Health Decree No. Ol/BIRHUKMAS/I/1975.
4. The soil fertility standard used was issued by the: Lembaga Penelitian Tanah Bogor.
Statistical method used in this research is the T test. The results of the research can be summarized as follows:
1. The significant differences of soil and water pHs between the area before development and after development with T test = 4,3822 for water pH and 3,3666 for Soil pHI;
2. From the above calculations we can know the average pH, that at the developed area is higher than the area that was not developed, namely: water pH = 4,1136 changes to 4,6277 and Soil pH from 3,700 be-came 3,888. From the results of the study we conclude that first and second hypothesis are significant;
The mean calculation from the questioner is 26,168 from the highest score is 60. It is mean that the transmigration community didn't know the impact of changes of soil and water pHs to drinking water and soil fertility, so the third hypothesis is also significant.
"
Jakarta: Program Pascasarjana Universitas Indonesia, 1992
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Komalasari
"Peraturan Menkes RI No.416 tahun 1990 dalam standar kualitas Air Minum menyatakan bahwa air minum tidak boleh terdapat bakteri Eschericia coil dalam 100 ml contoh air. Adanya bakteri Coliform merupakan indikasi air tercemar kuman pathogen, sehingga bakteri Coliform merupakan indikator pencemaran air secara mikrobiologis. Bakteri E. coil dapat menyebabkan Gastroenteristis. Salah satu cara mengurangi bakteri bakteri E. coil pada proses pengolahan air adalah dengan proses koagulasi (penggumpalan) yang diikuti proses flokulasi (pembentukan flok) dan sedimentasi (pengendapan flok). Salah satu faktor yang menentukan keberhasilan koagulan adalah penggunaan koagulan yang tepat untuk tingkat kekeruhan air baku yang sudah ditentukan (dalam hal ini kekeruhan tinggi). Koagulan yang umum digunakan adalah A12(SO4), yang biasa disebut tawas atau alum, karena cukup murah dan mudah didapat dipasaran. Kenyataan menunjukkan tingkat kekeruhan air baku (dalam hal ini sungai Ciliwung) semakin tinggi sehingga diperlukan koagulan altematif yang lebih efektif. Penggunaan koagulan PAC (Poly Aluminum Chlorida) sebagai koagulan alternatif yang lebih efektif untuk air baku kekeruhan tinggi.
Metode penelitian ini adalah true eksperimental. Sebagai kelompok eksperimen adalah sampel air baku yang diberi koagulan PAC, sedangkan kelompok pembanding adalah sampel air bake yang diberi koagulan Alum atau Tawas. Penelitian ini dilakukan dalam skala laboratorium, yaitu melalui analisa jartes untuk menentukan dosis optimum koagulan. Percobaan dilakukan di laboratorium pusat PAM Jaya dengan mengambil sampel air baku kekeruhan tinggi (100 - 500 NTU) dan melakukan lima kali percobaan dengan total sampel 30. Dosis koagulan yang digunakan adalah 20, 25, 30, 35, 40, 45 ppm.
Hasil yang diperoleh adalah Reduksi Eschericia coils rata-rata oleh PAC adalah 88.3166 dengan reduksi maksimum 99.97 % dan oleh Alum adalah 73.30 % dengan reduksi maksimum 96.67%. Secara statistik beda reduksi PAC terhadap Alum adalah perbedaan bermakna dengan nilai p < 0,05. Dosis optimum rata-rata PAC adalah 20 ppm dengan rata-rata reduksi 89.01 %. Dosis optimum rata-rata Alum adalah 30 ppm dengan rata-rata reduksi 81.60 %. Melihat kualitas air yang dihasilkan terhadap parameter pH, kekeruhan, dan E. coil lebih baik menggunakan PAC. Nilai rata-rata kualitas air pada pemberian dosis optimum PAC adalah : kekeruhan 7.2 NTU, pH akhir 7.08 dan reduksi E. coil 97.29%. Nilai rata-rata kualitas air pada pemberian dosis optimum Alum adalah : kekeruhan 16.2 NTU, pH 6.8 dan reduksi E. coil 95.06%.
Secara ekonomis didapat penghematan yang cukup besar, yaitu dengan pemakaian PAC dapat dihemat biaya Rp 47.740.400/bulan untuk Instalasi I PAM DKI Jaya. Perhitungan ini diambil dari penghematan penggunaan dosis koagulan dan dosis kapur tohor, dimana dengan PAC tidak diperlukan pemakaian kapur tohor untuk menaikkan pH.
Dari hasil ini disarankan untuk air baku kekeruhan tinggi PAC dapat dijadikan koagulan pengganti Alum, karena dan segi teknis lebih menguntungkan, yaitu tidak perlu penambahan kapur tohor untuk menetralkan pH dan mengurangi dosis Kaporit pada proses desinfeksi serta waktu digunakan lebih pendek, dari segi biaya lebih hemat, dan dari segi kualitas air yang dihasilkan lebih baik.

In general, raw water which comes from the river has been contaminated by human or animal feces which are shown by the existing of an organism society called Coli form such as Bacterium cola, Bacillus coil or Escherichia cola which are the ones of microbiologies parameter. The existent of Coli form bacteria is an indicator of pathogenic bacteria, so the Coli form bacteria is an indicator of microbiological water contamination. Ministry of health regulation no.416 1990 for standardization of drinking water states that the drinking water mustn't contain the Escherichia coil bacteria in 100 ml the sample of water.
The E. cola bacteria may cause Gastroenteritis. One way of reducing E.coli bacteri in the water treatment is by coagulation process which is followed by flocculation and sedimentation. One factor which determined the success of coagulation is the use of the right coagulant for determined standard turbid raw water (in high turbid level matter). The most commonly used coagulant is the AI2(SO,), called "Tawas" or "Alum", it is quite cheap and can be found easily. The fact shows that the high turbid level of raw water (in Ciliwung river matter) is getting higher, so an alternative of more effective coagulant is needed. Use of the PAC (Poly Aluminum Chloride) coagulant is more effective for high turbid level raw water.
Method used in this research is true experimental. The experiment group consists of samples of raw water with the PAC coagulant, compared with samples of raw water with Tawas or Alum coagulant. Research was done in a laboratory scale, through jartest analysis to decide the optimum dose of coagulant. The experiment was done at the PAM Jaya laboratory by taking samples of high turbid of raw water (100-500 NTU) and doing 5 times experiment with total samples of 30. The coagulant doses used of are 20, 25, 30, 35, 40, 45 ppm.
Average reduction of E. cola by the PAC is 88.32%, with maximum reduction of 99.97%, and by the Alum is 73.3% with the maximum reduction of 96.67%. Statistically, the reduction difference between PAC and Alum is (15.02 ± 5.33) % with p 0.05 in CI 95% of significant difference. The average optimum dose of PAC is 20 ppm with average reduction of 89 %. The average optimum dose of Alum is 30 ppm with average reduction of 81.6%. If we see the produced water quality the parameters like : pH, turbidity, and E.coli, it would be better for us to use the PAC. The average values of water quality with PAC optimum dose given are: the turbidity is 7.2 NTU, the last pH is 7.08 and the E. coil reduction is 97.29%. Conditions with Alum are: the turbidity is 16.2 NTU, the PH is 6.8 and the E.coli reduction is 95.06%.
Economically, by using the PAC we can save costs for about Rp 47.740.0001month. This calculation was done by savings in coagulant dose and in quick-lime dose, which by using the PAC we do not need the quick-lime to increase the pH anymore.
Using the results obtained, it's recommended, for the high level turbidity of the raw water, to use the PAC as a substitution of Alum. Technically, it gives more revenues by not using the quick-lime addition to neutralize the pH, reduces the "Kaporit" dose in the disinfection process, and shortens the process time. We can also reduce costs, because it's cheaper, and we can get better water quality than before.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 1996
T3944
UI - Tesis Membership  Universitas Indonesia Library
cover
Rahmania Hanifa
"Air lindi sampah merupakan cairan yang merembes atau keluar dari timbunan sampah. Dalam mengolah air lindi diperlukan proses yang dapat mendegradasi polutan organik salah satunya dengan proses Fenton. Pada penelitian ini kebaruan penelitian yang ingin ditunjukan adalah konsep ekonomi sirkular dengan cara penggunaan katalis Fenton heterogen dari limbah. Hal tersebut sejalan dengan agenda Pilot Project PLTSa Merah Putih yang ingin mengkaji pemanfaatan residu insinerasi. Tujuan dari penelitian ini adalah [1] menganalisis kinerja IPAS objek studi dari aspek tren kualitas air, efisiensi penyisihan, dan parameter desain, [2] menganalisis potensi pemanfaatan abu terbang PLTSa sebagai katalis proses Fenton untuk pengolahan air lindi, dan [3] menganalisis efektivitas proses Fenton heterogen sebagai post-treatment proses biologis pada instalasi pengolahan air lindi. Metode penelitian yang digunakan yaitu observasi, wawancara, pengambilan sampel dan karakterisasi air lindi IPAS 3 TPST Bantargebang, preparasi dan karakterisasi abu terbang Pilot Project PLTSa Merah Putih TPST Bantargebang, dan eksperimen Fenton. Eksperimen Fenton menggunakan air influen polishing pond IPAS 3 TPST Bantargebang. Hasil asesmen kinerja IPAS, kualitas air memiliki tren fluktuatif dan beberapa parameter tidak memenuhi baku mutu PermenLHK No. 59/2016, efisiensi penyisihan tergolong rendah dan terdapat sejumlah unit tidak memenuhi kriteria desain. Kemudian, abu terbang PLTSa berpotensi dimanfaatkan sebagai katalis proses Fenton untuk pengolahan air lindi dengan kandungan besi 157,86 mg/g. Hasil optimum proses Fenton berbasiskan katalis abu terbang PLTSa yaitu dengan konsentrasi katalis 1 g/L; rasio H2O2 0,25x; dan pH 3. Hasil proses Fenton dikombinasikan dengan ozon dapat menaikkan efisiensi penyisihan warna dan COD mencapai 82,25% dan 69,53%.

Landfill leachate is known as liquid seeps or comes out of the landfill. The Fenton method is one option for treating leachate since it may decompose organic contaminants. The novelty of the research to be shown in this study is the circular economy concept by using heterogeneous Fenton catalysts derived from waste. This is in accordance with the Pilot Project Municipal Solid Waste Incineration (MSWI) Merah Putih’s goal of studying the utilization of incineration residues. This study aimed to [1] analyze the performance of the leachate treatment plant from the aspect of removal efficiency and design parameters, [2] analyze the potential utilization of MSWI fly ash as a catalyst for the Fenton process for leachate treatment, and [3] analyze the efficiency of the heterogeneous Fenton process as a post-treatment biological process in a leachate treatment plant. The research method used were observation, interviews, sampling and characterization of Leachate Treatment Plant (LTP) 3 TPST Bantargebang’s leachate, preparation, and characterization of the Pilot Project MSWI Merah Putih’s fly ash, and Fenton experiment. According to the LTP evaluation, water quality has a fluctuating trend and certain parameters do not satisfy the quality standards of PermenLHK No. 59/2016, removal efficiency is low, and a number of units do not fulfill the design parameters. MSWI fly ash has the potential to be used as a Fenton process catalyst for leachate treatment with an iron content of 157.86 mg/g. The optimum results of the Fenton process were achieved with a catalyst concentration of 1 g/L; H2O2 ratio 0.25x; and pH 3. The results of the Fenton process combined with ozone can increase the efficiency of color and COD removal reaching 82.25% and 69.53%."
Depok: Fakultas Teknik Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Lendrawati
"ABSTRAK
Flotasi merupakan salah satu proses pemisahan, dan telah banyak diaplikasikan dalam industri logam, non logam dan proses pengolahan maupun pemurnian air. Penelitian mengenai flotasi dan aplikasinya telah banyak dilakukan dalam skala laboratorium untuk selanjutnya dapat dipakai dalam skala industri.
Penelitian ini mencoba memanfaaatkan fiotasi guna menurunkan warna air sungai lahan gambut agar Iayak konsumsi. Logam yang digunakan yaitu Ca dan Mg. Penelitian dilakukan melalui dua tahap, tahap pertama adalah mengetahui apakah flotasi dapat digunakan untuk menurunkan kadar warna air gambut, dengan menentukan kondisi optimum flotasi larutan kompleks logam-humat yaitu, pH dengan variasi 5, 6, 7, 8, 9 dan konsentrasi surfaktan dengan variasi konsentrasi dodesilamin; 0, 5, 10, 20, 30, 40, 50, 60, 70, dan 80 ppm. Tahap kedua adalah menerapkan flotasi dalam kondisi optimum untuk menurunkan warna air gambut Sungai Dumal, Riau. Sebelum masuk tahap pertama, harus ditentukan dulu berat molekul rata-rata asam humat dan perbandingan stoikiometri logam-humat. Pada fIotsi sampel, dilakukan variasi konsentrasi logam dan variasi berat kapur tohor. Parameter air yang diukur adalah kadar wama, kekeruhan, kadar logam, DHL, pH, bilangan KMn04, dan kesadahan. Parameter tersebut diukur sebelum dan sesudah flotasi.
Berat molekul rata-rata asam humat ditentukan dengan menggunakan viscometer ostwald dan data menunjukkan bahwa asam humat yang dipakai pada penelitian mi memiliki berat moekuI sebesar 109.406 g/mol. Perbandingan
stoikiometri Ca: Humat sekitar 55: 1 sedangkan Mg : Humat sekitar 36: 1. Flotasi Ca-Humat dapat berjalan secara optimum pada pH 6 dan [dodesilamin] = 50 ppm
dengan penurunan warna ±89% sedangkan untuk flotasi Mg-Humat, pH 7 dan [dodesilamin] = 40 ppm dengan penurunan warna ±92%. Flotasi sampel air gambut
Sungai Dumai dengan menambahkan logam sebesar 10 ppm dapat menurunkan kadar warna ±96% (flotasi dalam kondisi optimum Ca-Humat) dan ±81% (flotasi dalam kondisi optimum Mg-Humat). Flotasi dengan menggunakan kapur tohor
sebanyak 0,20 g untuk 250 ml sampel, menghasilkan penurunan warna sebesar ±95%.
Selain mempengaruhi kadar warna, flotasi juga mempengaruhi parameter air lainnya yaitu DHL, kekeruhan, kadar logam, kesadahan, dan bilangan KMn04. Diantara parameter tersebut, bilangan KMn04 air hasil flotasi belum memenuhi standar baku mutu air minum."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1999
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>