Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Aditya Nugraha Wardhana
Abstrak :
Penelitian dilakukan bertujuan untuk mengetahui perkiraan dampak potensial berbagai skenario ledakan senjata nuklir pada populasi penduduk dan beberapa sungai Jakarta. Pemodelan menggunakan empat skenario daya ledak: 10 kiloton, 500 kiloton, dan 1000 kiloton, dan 5000 kiloton. Skenario yang digunakan dibagi menjadi dua, yaitu dampak langsung dan tidak langsung dari ledakan senjata nuklir. Hasil menunjukkan perluasan wilayah dampak langsung seiring dengan peningkatan daya ledak senjata nuklir; radiasi panas memiliki cakupan wilayah dan laju perluasan tertinggi, sedangkan radiasi nuklir langsung memiliki laju perluasan terendah; dan perubahan arah wilayah dampak tidak langsung mengikuti pola angin musim normal dan musim terpengaruh fenomena atmosfer seperti badai tropis.
The research aims on determining potential effects of several nuclear weapon explosion scenarios on the population and rivers of Jakarta. Modeling used four yield scenarios: 10 kilotons, 500 kilotons, and 1000 kilotons, dan 5000 kilotons. Scenario used were divided into two, direct effects and indirect effects. Results show expansion of direct effects regions follows yield increase; thermal radiation region has the largest area and highest expansion rate, while direct nuclear radiation region has the lowest; and direction changes of non-direct effects regions follow normal seasonal and tropical storm-affected seasonal patterns.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S52910
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rachmat Triharto
Abstrak :
Tesis ini membahas tentang permasalahan kualitas daya listrik yang terjadi pada sistem kelistrikan pada instalasi nuklir. Penelitian dilakukan pada instalasi kelistikan reaktor nuklir RSG-GAS. Pada penelitian ini dilakukan audit kualitas daya listrik pada instalasi tersebut melalui pengukuran dengan menggunakan alat power quality analyzer. Audit kualitas daya listrik dilakukan untuk memastikan bahwa peralatan-peralatan listrik yang sensitif mendapat pasokan daya listrik yang berkualitas sehingga peralatan tersebut dapat bekerja sesuai desainnya, terutama perangkat-perangkat yang terkait dengan sistem keselamatan. Setelah memperoleh data dan informasi yang diperlukan, dilakukan analisa data melalui perbandingan dengan spesifikasi serta standar yang berlaku untuk masing-masing sistem yang terkait. Parameter yang dibahas pada tesis ini yaitu variasi tegangan, frekuensi, ketidakseimbangan tegangan, ketidakseimbangan beban, faktor daya dan harmonisa. Hasil analisis yang didapatkan menunjukkan beberapa temuan antara lain rata-rata tegangan steady state yang diatas 5 serta tingkat harmonisa arus orde ke 5 yang berada di luar batas yang direkomendasikan. Untuk memastikan defence in depth tetap terjaga maka perlu dilakukan mitigasi terhadap temuan yang ada. Teknik mitigasi yang disarankan adalah dengan menyesuaikan tingkat tegangan keluaran trafo dengan penyetelan tap changer, serta pemasangan filter harmonik pada masing masing busbar utama.
This thesis discusses the power quality problems that occur on the electrical system at nuclear installations. The study was conducted on the electricity installation of RSG GAS nuclear reactors. In this research, power quality audit at the plant through measurement using a power quality analyzer tool. Power quality audit performed to ensure that equipment sensitive electrical power supply gets qualified electrician so that the equipment can work according to design, especially the devices associated with safety systems. After obtaining the necessary data and information, to analyze data through comparison with the specifications and standards applicable to each of the related systems. The parameters discussed in this thesis is a variation of voltage, frequency, voltage unbalance, load imbalance, power factor and harmonics. The results of the analysis obtained show some of the findings, among others, the average steady state voltage is above 5 and 5th order harmonic current levels were above the recommended limit. To ensure defense in depth is maintained it is necessary to mitigate the existing findings. Suggested mitigation techniques are to adjust the output voltage level by using the transformer tap changer, and the installation of a harmonic filter at each main busbar.
Depok: Fakultas Teknik Universitas Indonesia, 2017
T47288
UI - Tesis Membership  Universitas Indonesia Library
cover
Ayu Harum Anggraeni
Abstrak :
ABSTRAK
Penelian ini bertujuan untuk melihat kesesuaian organisasi kesiapsiagaan dan penanggulangan kedaruratan nuklir tingkat satker di Pusat Pendayagunaan Informatika dan Kawasan Strategis Nuklir (PPIKSN) BATAN berdasarkan Perka BAPETEN Nomor 01 Tahun 2010 dan Standar IAEA GSR Part. 7. Penelitian kualitatif ini dilakukan dengan observasi lapangan, wawancara, dan telaah dokumen. Metode yang digunakan adalah evaluasi sesuai dengan Peraturan Kepala Badan Pengawas Tenaga Nuklir No. 01 Tahun 2010, dan standar internasional yaitu IAEA Standard No. GSR Part. 7. Hasil dari penelitian ini menunjukkan bahwa sebagian besar elemen organisasi kesiapsigaan dan penanggulangan kedaruratan nuklir tingkat satker di Pusat Pendayagunaan Informatika dan Kawasan Strategis Nuklir (PPIKSN) BATAN telah memenuhi standar. Elemen yang belum semuanya persyaratannya terpenuhi adalah tindakan perlindungan bagi personil kedaruratan. Persyaratan yang tidak terpenuhi dalam elemen tersebut adalah tidak adanya informed consent. Untuk itu diperlukan pengadaan dan perbaikan bagi organisasi kedaruratan nuklir yang belum memenuhi persyaratan, serta pemeliharaan bagi yang sudah terpenuhi.
ABSTRAK
The aim of this study presented to view the organization?s conformance nuclear emergency preparedness and response satker level at the Pusat Pendayagunaan Informatika dan Kawasan Strategis Nuklir (PPIKSN) BATAN based Perka BAPETEN Nomor 01 Tahun 2010 and IAEA Standard GSR Part. 7. The qualitative research was conducted by field observations, interviews, and review the document. The method used is the evaluation in accordance with Peraturan Kepala BAPETEN No.01 Tahun 2010, and international standards, that is the IAEA Standard GSR Part. 7. The result of this study showed that most of the elements of the organization of nuclear emergency preparedness and response satker level at Pusat Pendayagunaan Informatikan dan Kawasan Strategis Nuklir (PPIKSN) BATAN according to the standard. Elements that not all term are appropriate in these element is the absence of informed consent. It required the procurement and the improvement for the nuclear emergency organization which do not appropriate the requirements, as well as maintenance for the already fulfilled.
2016
S64972
UI - Skripsi Membership  Universitas Indonesia Library