Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 38 dokumen yang sesuai dengan query
cover
Nizhamul Latif
"Dalam penelitian ini dilakukan study tentang pengaruh ion chlorida terhadap pemanfaat inhibitor nitrit dan betz didalam air pendingin. Dari penelitian tersebut diketahui bahwa :
1. Pemakaian inhibitor nitrit, efektif untuk air baku tanpa NaCl dan yang mengandung NaCl 20,200 & 400 ppm setelah konsentrasi inhibitor masing-masing melebihi 150 ppm, 200 ppm, 300 ppm dan 500 ppm.
2. Pemakaian inhibitor betz, efektif untuk air baku tanpa NaCl dan yang mengandung NaCl 20,200 & 400 ppm setelah konsentrasi inhibitor masing-masing melebihi 100 ppm, 150 ppm, 400 ppm dan 600 ppm.
3. Pada konsentrasi NaCl yang rendah pemakaian inhibitor Betz lebih efektif dibanding inhibitor nitrit.
4. Sedangkan pada konsentrasi NaCl yang tinggi pemakaian inhibitor nitrit lebih efektif dibanding inhibitor betz."
Depok: Universitas Indonesia, 1993
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Budi Utomo
"Nanofluida adalah jenis fluida baru, yaitu pencampuran partikel nano dalam fluida dasar (air), dimana partikel nano ini tetap tersuspensi secara permanen dalam fluida dasarnya, akibat adanya gerakan Brownian dari partikel nano tersebut. Dalam menentukan karakteristik operasi dari alat penukar kalor dengan metoda grafik, penelitian dilakukan pada air-air dan menjelaskan hubungan kalor antara yang hilang dengan parameter - parameter lainnya, seperti aliran fluida dan sifat-sifat termal pada alat double pipe heat exchanger. Penelitian dilakukan pada nanofluida A1203, hasilnya menunjukkan peningkatan dalam koefisien perpindahan kalor konveksi dibandingkan dengan fluida dasarnya 2.1%-11.86% untuk konsentrasi partikel nano 1% dan 4.2% 17.38% untuk konsentrasi partikel nano 4%. Rasio peningkatan koefisien perpindahan kalor konveksi dari nanofluida juga meningkat, seiring dengan peningkatan temperatur (40°C - 60°C).

Nano fluids are a new kind of fluids; they are dispersion if nano particles in liquids that are permanently suspended by Brownian motion. To assign operation characteristic from heat exchanger with graphic method, Research shown at water to water assignment shows correlation between heat loss and other parameters, such as: fluids flow and thermal characteristic in double pipe heat exchanger. Research shown at nano fluid A1203 water 1% and 4%, the result shown the enhancement of heat transfer convective coefficient compared to the base fluids 2.1%- 11.86% for 1% particles concentration and 4.2% -17.38% for 4% particles concentration. The rate of increase of enhancement shows adrainatic increase with elevated temperature (40°C-60°C)."
Depok: Fakultas Teknik Universitas Indonesia, 2003
T14739
UI - Tesis Membership  Universitas Indonesia Library
cover
New York: McGraw-Hill, 1974
621.4022 HEA
Buku Teks  Universitas Indonesia Library
cover
cover
Universitas Indonesia, 1993
S27924
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Experimental investigation on two-phase flow boiling heat transfer of R-410A and R-134A in horizontal small tubes is reported. The pressure drop and local heat transfer coefficients were obtained over heat flux range of 5 to 40 kW/m2, mass flux range of 70 to 600kg/ m2s, saturation temperature range of 2 to 12°C, and quality up to 1.0 in test section with inner tube diameters of 3.0 and 0.5mm, and lengths of 2000 and 330mm, respectively. The section was heated
uniformly by applying a direct electric current to the tubes. The effects of mass flux, heat flux, and inner tube diameter on pressure drop and heat transfer coefficients are presented. The
experimental results are compared against several existing correlations. A new boiling heat transfer coefficient correlation based on the superposition model for refrigerants in small tubes
is also presented."
[Fakultas Teknik UI, Chonnam National University. Department of Refrigeration and Air Conditioning Engineering], 2011
pdf
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Andi Bakhtiar
Depok: Fakultas Teknik Universitas Indonesia, 1994
S36328
UI - Skripsi Membership  Universitas Indonesia Library
cover
Calim
Depok: Fakultas Teknik Universitas Indonesia, 1994
S36338
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhamad Reza Dirgantara
"ABSTRAK
Perhitungan perancangan alat penukar kalor pelat bersirip dengan metode
konvensional (integral) di mana suatu alat penukar kalor dianggap sebagai satu
keseluruhan, dan sifat-sifat aliran di evaluasi pada lemperatur rata-rata aliran, tidak
menunjukkan kondisi yang sebenarnya terjadi sepanjang alat penukar kalor
tersebut, sehingga hasil perhitungan ini memungkinkan terjadinya ketidak cocokan
dengan kondisi aktual di lapangan saat di operasikan.
Untuk mengatasi permasalahan di alas make suatu alat penukar kalor dapat
di bagi ke dalam banyak segmen, di mana perhitungan di lakukan secara bertahap
pada tiap segmen dengan melibatkan variasi sifat-sifat terrnohidrolis aliran. Metode
ini dinamakan metode diferensial sehingga dengan demiklan seorang pefancang
akan mendapatkan hasil perhitungan yang lebih akurat dan realistis serta dapat
memperkirakan karakteristik kerja alat penukar kalor tersebut sepanjang aliran
fluida.
Sebuah kode program dibuat untuk menerapkan metode perhitungan di atas
dan dilakukan perbandingan dengan metode perhitungan konvensional (integral)
pada bagian studi kasus. Hasil perhitungan menunjukkan bahwa tidak terjadi
perbedaan yang cukup signifikan antara hasil perhitungan metode integral dengan
diferensial pada perhitungan kalor (thermal performance) sedangkan pada
perhitungan jatuh tekan (pressure drop performance) perbedaan yang terjadi cukup
besar.
Dari pembahasan di atas dapat disimpulkan bahwa penggunaan metode
diferensial pada perancangan alat penukar kalor pelat bersirip memiliki tingkat
akurasi yang lebih balk, mengingat perhitungan yang dilakukan di dasarkan pada
pendekatan kondisi operasi alat penukar kalor yang sesungguhnya. Hal ini terlihat
pada perhitungan jatuh tekan di bagian studi kasus, dimana variasi sifat-sifat
termohidrolis cukup besar (khususnya densitas fluida, p) maka akan terjadi
perbedaan cukup besar pada harga jatuh tekan dibandingkan dengan metode
konvensional/integral.

"
1996
S36258
UI - Skripsi Membership  Universitas Indonesia Library