Abstrak :
Studi ini menyajikan metode analisis eksergi, dengan melakukan pengambilanserta perhitungan data untuk menara pendingin di pabrik urea Pusri I-B. Studi ini bertujuanmenganalisis kinerja menara pendingin dengan mengkaji besarnya irreversibilitas danefisiensi eksergi. Dari hasil penelitian di dapat irrevesibilitas dari proses pendinginan dimenara pendingin selama 24 jam bervariasi antara 614,09 kW hingga 731,202 kW. Dimanapada pukul 21:00 irreversibilitas terendah dan pukul 15.00 irrevesibilitas tertinggi yaitusebesar 614,09 kW dan 731,202 kW. Nilai efisiensi eksergi diketahui antara 41,12% sampai59,04%.Kata kunci: menara pendingin, irreversibilitas, efisiensi eksergi.
Palembang: Fakultas teknik Universitas tridinanti palembang, 2014
600 JDTEK 2:1 (2014)
Artikel Jurnal  Universitas Indonesia Library
cover
Yudho Hartanto
Abstrak :
Untuk mendapatkan skema terbaik dalam manajemen BOG dan pemanfaatan potensi eksergi LNG di fasilitas terminal regasifikasi Arun sebagai pembangkit energi listrik, maka dilakukan penelitian untuk membandingkan secara teknis dan komersial skema terbaik  pemanfaatan potensi exergi LNG dari proses regasifikasi.  Manajemen pemanfaatan BOG dengan laju  9.8 ton/jam dan pemanfaatan potensi exergi LNG dengan laju 150 ton/jam dengan teknologi Rankine Cycle (RC), Direct Expansion (DE)  atau kombinasi RC+DE untuk  pembangkit listrik diteliti dalam tesis ini.  Energi listrik yang dihasilkan dijual kepada PLN dengan skema jual beli listrik dengan harga maksimal 90% dari BPP sebesar Rp 1,673/kWh untuk Aceh dan Sumatera Utara. Data dari hasil penelitian dan simulasi sistem, didapatkan bahwa pemanfaatan potensi exergi LNG skema DE menghasilkan daya bersih listrik sebesar 2,703 kW, skema RC menghasilkan 3,916 kW, dan  skema DE+ RC menghasilkan 5,849 kW. Pendapatan dari penjualan daya listrik yang dihasilkan akan meningkatkan pendapatan operasional perusahaan. ......To get the best scheme in BOG management and utilization of LNG exergy potential in the Arun LNG regasification facility to generate electricity, this research is conducted to compare the best technical and commercial schemes for utilization of LNG potential exergy from the regasification process. The management system is required to manage  BOG  flow rate 9.8 ton / hour and LNG cold energy utilization with flowrate 150 ton/hour during  regasification process to generate electricity using Direct Expansion (DE), Rankine Cycle (RC) or combined Direct Expansion + Rankine Cycle (DE+RC)  technologies are studied in this thesis. The electricity produced is sold to PLN under a power purchase scheme at a maximum price  90% from the BPP tariff Rp 1,673/kWh for Aceh dan Sumatera Utara.  Data from the results of research and system simulations, it is found that the utilization of the LNG exergy  in the DE scheme produces a net electric power of 2,703 kW, the RC scheme produces 3,916 kW, and the DE + RC scheme produces 5,849 kW.  The income from the sale of the electric power generated will increase Company's income.
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
R. Dandy Yusuf Maynardi
Abstrak :
ABSTRAK PT. X telah melakukan studi kelayakan untuk rencana konversi dengan penggunaan 60 bahan bakar LNG pada salah satu lini kapalnya dengan trayek Tanjung Priok ndash; Makassar dengan memanfaatkan LNG Isotank tipe T75 ukuran 20 kaki 1 TEU , namun hanya terbatas pada kajian secara ekonomis. Untuk melakukan verifikasi bahwa rencana konversi ini benar-benar menguntungkan, penulis merasa perlu untuk melakukan kajian dari sudut pandang akademis, khususnya analisis karakteristik exergy fisik yakni laju perpindahan dan penghancuran exergy melalui dinding tangki akibat perpindahan kalor, serta karakteristik boil-off rate BOR dan boil-off gas BOG dari LNG yang dimuat, dilakukan dengan pendekatan closed system exergy balance dengan parameter kondisi pelayaran yang telah ditentukan, menggunakan persamaan empiris dari literatur dan model fisik dari tiga opsi tangki yang ditawarkan, dirancang dengan menggunakan COMSOL Multiphysics 5.1. Hasil analisis menunjukkan hubungan berkorelasi positif antara laju penghancuran exergy dengan nilai BOR dan BOG, bergantung pada nilai hambatan termal total Rtot akibat variasi material kulit dan insulasi dinding tangki yang mempengaruhi nilai kebocoran panas heat leak pada permukaan dalam dan luar dinding tangki. Skala kualitas disajikan di akhir pembahasan untuk meringkas parameter analisis yang bisa diukur dengan harga, yakni exergy cost dan biaya pengoperasian yang diperlukan forced vaporizer untuk mencapai BOR yang dibutuhkan.
ABSTRACT
PT. X has conducted a feasibility study for conversion plans with the use of 60 LNG fuel on one of its ship lines with Tanjung Priok Makassar route using LNG Isotank type T75 size 20 feet 1 TEU , but only limited to economical study. To verify that the conversion plan is really profitable, analysis of physical exergy characteristics i.e. the rate of exergy transfer and destruction through tank wall due to heat transfer, boil off rate and boil off gas from stored LNG is conducted by a closed system exergy balance approach with specified shipping conditions parameters, using the empirical equations of the literature and physical model of the three tank options offered, designed using COMSOL Multiphysics 5.1. The results show a positive correlation between exergy destruction rate with BOR and BOG values, depending on the total thermal resistance value Rtot due to material variation of shell and insulation of tank wall affecting the value of heat leak on the inner and outer surface of the tank wall. Quality scale is presented to summarize the analysis parameters that can be measured by cost, i.e. the exergy cost and operating costs required by forced vaporizer to achieve the required BOR.
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Agus Noor Sidiq
Abstrak :
Pemanfaatan hasil panas buang suatu sistem pembangkit dapat meningkatkan nilai efisiensi sistem. Siklus Kalina dapat menyediakan solusi untuk membangkitkan daya dari hasil buangan panas pada suatu system pembangkit listrik ataupun dari sumber panas bumi dengan temperature rendah. Untuk mempelajari aplikasi dan perancangan sistem termal yang menggunakan Siklus Kalina digunakan suatu aplikasi pemodelan sistem energi. Proses studi ini dilakukan dengan pembuatan simulasi sistem yang dibantu oleh software Cycle Tempo 5.0 untuk mengetahui efisiensi dan energi yang dapat dibangkitkan dari suatu sumber panas. Suatu campuran fluida ammonia-water dimanfaatkan sebagai fluida kerja dalam proses sistem siklus Kalina (KCS) 11. Untuk memperoleh daya dan efisiensi maksimum yang dihasilkan sistem dilakukan proses optimasi pada fraksi massa campuran fluida kerja ammonia-water dan tekanan keluar turbin. Dari hasil pemodelan dan simulasi maka didapatkan suatu system KCS 11 yang memiliki nilai tertinggi pada daya pembangkitan dan efisiensi. ......The utilization of waste heat produced by power plant system will gain the efficiency value for the system it self. Kalina cylce system gives a solution to generate power from wasted heat or from geothermal with low temperature. The modeling application on energy system is use to study the design of thermal system that using Kalina cycle. The study of this process is done by using Cycle Tempo 5.0, a simulating software, to get the data of the efficiency and the energy that could be generated from heat source. An ammonia-water mixture is used as a working fluid on Kalina cycle system (KCS) 11. To get maximum power output and maximum efficiency, the system will be optimize on the mass fraction of working fluid, ammoniawater, and also the turbine output pressure. The result of the simulation is to get the best performance of KCS 11 that have high power output and efficiency.
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37338
UI - Skripsi Open  Universitas Indonesia Library
cover
Muhammad Syafaat
Abstrak :
Pembangunan PLTU memerlukan bahan bakar. Oleh karena itu, perlu dilakukan suatu analisa energi agar efisiensi penggunaan bahan bakar meningkat. Berkaitan dengan hal tersebut maka dalam penulisan skripsi ini akan dilakukan suatu analisa exergi pada penentuan konfigurasi Feedwater Heater yang digunakan pada sistem air-uap PLTU. Analisis dilakukan dengan menghitung besar efisiensi exergi dari tiap konfigurasi Feedwater Heater. Perhitungan exergi dari sistem dilakukan dengan menggunakan bantuan cycle tempo 5.0. Diharapkan hasil analisa exergi ini dapat digunakan sebagai informasi teknis dalam pembangunan proyek PLTU kelas 1 x 25 MW ......Due to the requirements of steam power plant construction which is going to spend a large amount of fuel and cost, energy and economy analysis are needed to improve the efficiency of fuel and total capital investment. Because of that, in this final assignment, exergy analysis will be used to choose feedwater heater configuration in water-steam system of steam power plant. The analysis will be done by calculating the amount of the efficient exergy from each of feedwater heater configuration. The calculation exergy of the system was done by using cycle tempo 5.0. The result of exergy are expected to be used as the technical information in contructing the 1 x 25 MW steam power plant.
Depok: Fakultas Teknik Universitas Indonesia, 2007
S37888
UI - Skripsi Membership  Universitas Indonesia Library
cover
Schmidt, Achim
Abstrak :
Thermodynamics is a subject that all engineering students have to face and that most of them treat with great respect. This makes it all the more important to offer a good and easy-to-understand approach to the laws of energy conversion. This is what this textbook is intended to do: It covers the basics of classical technical thermodynamics as they are typically taught at universities: The first and second law of thermodynamics as well as equations of state are explained for idealized and real fluids which are subject to a phase change. Thermodynamic mixtures, e.g. humid air, are treated as well as chemical reactions. Components and thermodynamic cycle that convert energy are presented. The book attaches great importance to drawings and illustrations, which should make it easier to comprehend complex matter. Technical applications and apparatus are presented and explained. Numerous exercises and examples conclude the book and contribute to a better understanding of the theory.
Switzerland: Springer Cham, 2019
e20503227
eBooks  Universitas Indonesia Library
cover
Awaludin Martin
Abstrak :
The performance of a 20 MW gas turbine power plant was described by using the exergy analysis and data from the plant’s record books. The first and second laws of thermodynamics, as well as the mass and energy conservation law, were applied in each of the components. The results show that more exergy destruction occured in the combustion chamber up to 71.03% or 21.98 MW. Meanwhile, the lowest exergy occured in the compressor at 12.33% or 3.15 MW. Thermal efficiency of the gas turbine power plant, according to the first law, was 33.77%, and exergy efficiency was 32.25%.
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:5 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Bakhrul Ulum
Abstrak :
Excellence in skilled operation is vital for the efficiency of geothermal power plants. Mount Salak geothermal power plant unit 1-2-3 has consistently produced no less than 180 MWe to the Java-Bali grid since its first commercial operation in 1994, with an equivalent availability factor (EAF) average of 96%. Owing to this long operation period, power plant efficiency must be improved for the sustainable production of electricity. In this study, energy and exergy analysis has been undertaken to ascertain the amount of energy that is used in the power plant’s current condition, and to determine the plant’s overall system losses. Research was carried out by collecting data relating to temperature, pressure, and mass flow rate. Data were analyzed using the control volume to assess the thermal and mass balance and ascertain the value of exergy. Analysis was conducted theoretically and compared with results calculated by Engineering Equation Solver (EES) software. The results showed that from 1069.90 MWe in steam energy entering the system, the total amount of exergy was 302.42 MWe. Mount Salak geothermal power plant unit 1-2-3 had an overall first law efficiency of 16.75% and an overall second law efficiency of 59.27%. The greatest losses - 27.84% of the total exergy - were in the condensers. This was caused by the quality of cooling water entering condensers, which was in turn a result of cooling tower performance. Results suggest that turbine unit 1 should be investigated further to determine causes of decreased capacity.
Depok: Faculty of Engineering, Universitas Indonesia, 2017
UI-IJTECH 8:7 (2017)
Artikel Jurnal  Universitas Indonesia Library
cover
Felix Pratama
Abstrak :
ABSTRAK
Tujuan dari penelitian ini adalah untuk melakukan simulasi dan optimisasi berdasarkan energi dan eksergi dari kepala sumur ke pembangkit listrik and membandingkan apakah analisis berdasarkan energi dan eksergi memberikan hasil yang sama. Perubahan kondisi fluida panas bumi yang mengalir dari kepala sumur ke pembangkit listrik melalui perpipaan diperhitungkan. Siklus flash-binary diajukan sebagai siklus pembangkit listrik dengan Organic Rankine Cycle (ORC) sebagai siklus binary. Beberapa kombinasi campuran zeotropik digunakan sebagai fluida kerja ORC. Siklus yang diajukan dibandingkan dengan siklus yang sudah ada di Sibayak, yakni siklus single flash, dari segi ekonomi dan performa termodinamika. Sumur panas bumi disimulasikan menggunakan WellSim, sementara perpipaan dan pembangkit listrik disimulasikan menggunakan UniSim Design. Hasil simulasi yang diperoleh dioptimisasi dengan metode Genetic Algorithm (GA) di MATLAB untuk memaksimumkan Net Present Value (NPV) dan meminimumkan Levelized Cost per Unit Exergy of Overall System . Analisis parametrik dilakukan untuk menguji pengaruh tekanan kepala sumur, tekanan separator, dan komposisi fluida kerja terhadap fungsi objektif. Sebagai perbandingan antara ekonomi dan performa termodinamika, optimisasi untuk memaksimumkan produksi listrik dan efisiensi eksergi dilakukan. Optimisasi NPV dan memberikan hasil yang sama di mana siklus flash-binary dengan R601 murni sebagai fluida kerja ORC adalah siklus yang paling ekonomis. Dari performa termodinamika, campuran zeotropik sebagai fluida kerja ORC menghasilkan produksi listrik dan efisiensi eksergi yang maksimum. Hasil optimisasi menunjukkan bahwa sistem yang paling ekonomis tidak dapat memperoleh sistem dengan performa termodinamika terbaik dan berlaku sebaliknya. Penggunaan ORC sebagai bottoming cycle siklus single flash memberikan NPV yang lebih tinggi dan yang lebih rendah dibandingkan siklus single flash, Selain itu, penggunaan ORC dapat mengurangi kehilangan eksergi oleh brine dari 30,65 menjadi 17,85 dari total eksergi yang masuk ke sistem. Efisiensi energi dan eksergi dari pembangkit listrik juga meningkat masing-masing dari 8,47 menjadi 10,05 dan 33,37 menjadi 39,60. Hasil analisis merekomendasikan siklus flash-binary untuk pembangkit listrik di Sibayak.
ABSTRACT
The purposes of this research are to conduct simulation and optimization based on energy and exergy from wellhead to power plant and compare whether analysis based on energy and exergy give the same results. Changes of geothermal fluid condition that transmitted from wellhead to power plant by pipelines are also considered. A flash-binary cycle is proposed as geothermal power plant cycle with organic Rankine cycle (ORC) as the binary cycle. Various combinations of zeotropic mixtures are used as ORCs working fluid. The proposed cycle is compared to existing cycle in Sibayak, that is single flash cycle, from economic and thermodynamic performance. The geothermal wells are simulated using WellSim, while the pipelines and power plant are simulated using UniSim Design. The obtained results are optimized with Genetic Algorithm (GA) method in MATLAB for maximizing Net Present Value (NPV) and minimizing Levelized Cost per Unit Exergy of Overall System . Parametric analysis is performed to examine the effects of wellhead pressure, separator pressure, and working fluid composition on the objective function. As a comparison between economic and thermodynamic performance, optimization to maximize net power output and exergy efficiency are also conducted. The NPV and optimizations give a same result where a flash-binary cycle with pure R601 as ORCs working fluid is the most economic cycle. From thermodynamic performace, zeotropic mixtures as ORCs working fluid give maximum net power output and exergy efficiency. Optimization results implied that the most economically effective system cant obtain the best system thermodynamic performance and vice versa. Utilization of ORC as bottoming cycle of single flash cycle gives higher NPV and lower compared to single flash cycle. Moreover, utilization of ORC can reduce exergy loss caused by brine from 30,65 to 17,85 of overall exergy input. The energy and exergy efficiency of power plant is also increased from 8,47 to 10,05 and 33,37 to 39,60, respectively. The results of analysis recommend a flash-binary cycle for Sibayak power plant.
2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Maulana Rifaldi
Abstrak :
Pemanfaatan hasil panas buang suatu sistem pembangkit dapat meningkatkan nilai efisiensi sistem. Siklus Kalina dapat menyediakan solusi untuk membangkitkan daya dari hasil buangan panas pada suatu sistem pembangkit listrik ataupun dari sumber panas bumi dengan temperatur rendah. Untuk mempelajari aplikasi dan perancangan sistem termal yang menggunakan Siklus Kalina digunakan suatu aplikasi pemodelan sistem energi. Proses studi ini dilakukan dengan pembuatan simulasi sistem yang dibantu oleh software Cycle Tempo 5.0 untuk mengetahui efisiensi dan energi yang dapat dibangkitkan dari suatu sumber panas. Suatu campuran fluida ammonia-water dimanfaatkan sebagai fluida kerja dalam proses sistem siklus Kalina (KCS) 34. Untuk memperoleh daya dan efisiensi maksimum yang dihasilkan sistem dilakukan proses optimasi pada fraksi massa campuran fluida kerja ammonia-water dan tekanan keluar turbin. Dari hasil pemodelan dan simulasi maka didapatkan suatu sistem operasi termal yang memiliki nilai tertinggi pada konfigurasi efisiensi dan daya terbaik. ......The utilization of waste heat produce by power plant system will gain the efficiency value for the system it self. Kalina cylce system gives a solution to generate power from wasted heat or from geothermal with low temperature. The modeling application on energy system is use to study the design of thermal system that using Kalina cycle. The study of this process is done by using Cycle Tempo 5.0, a simulating software, to get the data of the efficiency and the energy that could be generate from heat source. An ammonia-water mixture is use as a working fluid on Kalina cycle system (KCS) 34. to get maximum power output and maximum efficiency, the system will be optimize on the mass fraction of working fluid, ammoniawater, and also the turbine output pressure. The result of the simulation is to get the best performance of KCS 34 that have high power output and efficiency.
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37335