Adi Teguh Purnomo
"Evaluasi dosis radiasi yang diterima pasien dapat dilakukan menggunakan metode dosimetri in-vivo dengan melakukan pengukuran dosis masukan yang didefinisikan sebagai dosis serap pada kedalaman maksimum. Dosimeter in-vivo yang digunakan adalah TLD-100 rod, Film Gafchromic EBT2, dan dioda EDP-153G yang dikalibrasi berdasarkan protokol IAEA dan ESTRO. Hasil faktor kalibrasidetektor dioda sebesar 0.0988 cGy/ADU dan 0.0966 cGy/ADU untuk protokol IAEA dan ESTRO sedangkan Faktor kalibrasidetektor TLD memiliki rata-rata perbedaan sebesar 3.69 ± 0.04 %. Selain itu, faktor koreksi dioda EDP-153G terhadap variasi SSD, luas lapangan, dan linieritas dosis berada dalam rentang nilai 0.99-1.01 untuk protokol IAEA dan ESTRO sedangkan faktor koreksi terhadap sudut sinar datang berada dalam rentang nilai 1.028 - 1.037 dan 1.027-1.057 untuk protokol IAEA dan ESTRO. Pengukuran dosimetri in-vivo dititikberatkan pada kasus kanker paru dan prostat dengan meletakkan dosimeter in-vivo diatas permukaan kulit untuk beberapa titik pengukuran. Dosis masukan yang diperoleh bervariasi untuk setiap titik pengukuran akibat adanya perbedaan fluence. Evaluasi dosis pada organ target juga ditentukan dengan meletakkan film Gafchromic EBT2 pada slab fantom Rando Alderson. Persentase error yang diperoleh terhadap dosis yang direncanakan yakni sebesar 0.03% pada film 1 dan 2.5% pada film 2 untuk kanker paru sedangkan untuk kanker prostat sebesar 5.88% untuk film 1 dan 5.50% untuk film 2.

Evaluation of the radiation dose received by the patient could be performed with the in-vivo dosimetry by mean of the entrance dose measurement which defined as the absorbed dose to the maximum depth. TLD-100 rod, Gafchromic EBT2 film, and diode EDP-153G were used as in-vivo dosimeters and calibrated by the IAEA and ESTRO protocol. The results of calibration factor for diode EDP-153G was 0.0988 cGy/ADU and 0.0966 cGy/ADU for the IAEA and ESTRO, respectively while the differences of mean percentage was 3.69 ± 0.04 % relative to IAEA protocol for TLD. In addition, a correction factor for diode EDP-15­3Gto the variation of SSD, field size, and dose linearity were within the range of0.99-1.01 for the IAEA and ESTRO while the angular correction factor was at 1.028-1.037 and 1.027-1.057 for the IAEA and ESTRO protocol, respectively. The in-vivo dosimetry measurement was concerned in lung and prostate carcinoma by putting the in-vivo dosimeters on skin surface at some points of interest. The entrance dose measurement was varied for each point of measurement due to difference of fluence. The target dose evaluation was also determined by placing the Gafchromic EBT2 Film into slab of Rando Alderson phantom. The percentage error to the planned dose was 0.03% at the film 1 and 2.5%at the film 2 for lung carcinoma while for prostate carcinoma was 5.88% for the film 1 and 5.50% for film 2.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S54915
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gultom, Jannus
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1993
S27943
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dwi Seno Kuncoro S
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2004
T40299
UI - Tesis Membership  Universitas Indonesia Library
cover
Imada Fatma
"Penelitian ini bertujuan untuk memperoleh nilai parameter dosimetri sumber brakhiterapi intrakaviter Cs 137 model CSM40 milik Rumah Sakit Umum Pusat Persahabatan dengan menggunakan software Monte Carlo N Partikel versi 5 (MCNP5). Nilai parameter dosimetri yang ditentukan sesuai dengan rekomendasi AAPM TG43, yang meliputi : faktor geometri, air kerma strength, konstanta laju dosis, fungsi dosis radial, dan fungsi anisotropi. Berdasarkan nilai parameter yang diperoleh, laju dosis dapat dikalkulasi dengan menggunakan persamaan yang tersedia dalam TG43. Selanjutnya laju dosis dalam air sepanjang sumbu transversal (θ=90) ditentukan.
Dari hasil simulasi dan perhitungan diperoleh bahwa air kerma strength dan konstanta laju dosis Cs 137 CSM40 berturut-turut 1840 cGy.h-1.cm2 dan 0.994 cGy.h-1.U-1. Selain itu laju dosis dalam air sepanjang sumbu transversal dikalkulasi dengan metode Sievert. Akhirnya, perhitungan laju dosis sepanjang θ=90 dengan ketiga metode dibandingkan. Diperoleh bahwa ratarata perbedaan antara metode monte carlo dengan Sievert sekitar 11% dan antara monte carlo dengan TG43 sekitar 0.4%.

This study is aimed to calculate dosimetry parameters of brachytherapy intracavitary source Cs 137 CSM40 which is used by RSUP Persahabatan following the recommendation of AAPM TG43 and by using software Monte Carlo N Particle version 5 (MCNP5). The parameters which has been obtained are : geometry factor, air kerma strength, dose rate constant, radial dose function, and anisotropy function. After that, the calculation of dose rate will be enabled using TG43 formalism.
It has been obtained that the value of air kerma strength and dose rate constant are 1840 cGy.h-1.cm2 and 0.994 cGy.h-1.U-1 respectively. The value of dose rate in water along θ=90 also has been calculated using Sievert method and TG43 formalism. Finally, the result of the three methods is compared and it is found approximately 11% difference between monte carlo and Sievert method and 0.4% between monte carlo and TG43 method.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2006
T20876
UI - Tesis Membership  Universitas Indonesia Library
cover
Muhammad Stani Amrullah Andriansyah
"Pada kamera gamma tidak tercantum laju dosis yang diterima oleh pasien, melainkan hanya terdapat satuan count per second (cps), padahal laju dosis radiasi akibat radioisotop menentukan keamanan pasien. Pada penelitian ini dilakukan estimasi dosis permukaan pada simulasi pemeriksaan tiroid : studi fantom dan kalkulasi monte carlo pada kamera gamma. Penelitian ini dilakukan dengan menempatkan sumber Tc-99 m sebesar 2; 2,5; 3; 3,5; 4; 4,5 dan 5 mCi pada Neck Thyroid Phantom yang telah diletakkan Thermoluminiscence Dosimeter (TLD) di atasnya. Selanjutnya kamera gamma mencacah selama 5 menit dan hasilnya dibandingkan dengan hasil dari bacaan TLD. Dari penelitian ini didapatkan hasil dosis rata-rata TLD terhadap cacahan Kamera Gamma 5,77 x 10-8 ± 0,91 x 10-8 mGy/cacah dan dosis Monte Carlo terhadap cacahan Kamera Gamma 7,14 x 10-8 mSv/cacah.

In Gamma camera, there is not listed the dose rate received by the patient, but there is only count per second (cps), while the radiation dose rate due to the radioisotope determine the safety of patients. In this research surface dose estimates on thyroid exam simulation : phantom studies and monte carlo calculations performed on a gamma camera was done. This research was carried out by placing the source of Tc-99 m by 2; 2,5; 3; 3,5; 4​​; 4,5 and 5 mCi on Neck Thyroid Phantom that has been placed Thermoluminiscence Dosimeters (TLD) on it. Furthermore, the radiation was counted with a gamma camera for 5 minutes and the results were compared with the results of the TLD reader. From this research the results of the average dose TLD toward Gamma Camera count 5,77 x 10-8 ± 0,91 x 10-8 mGy/count and dose Monte Carlo toward Gamma Camera count 7,14 x 10-8 mSv/count were obtained.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S45182
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yunita Afrianti
"Penelitian yang bertujuan untuk mengetahui pengaruh energi 10 keV hingga 1500 keV terhadap nilai respon dosis thermoluminisence dosimeter (TLD) LiF : Mg Ti menggunakan simulasi user kode Monte Carlo yaitu DOSXYZnrc telah dilakukan. Pemodelan dilakukan dengan meletakkan TLD di medium udara dengan jarak 100 cm dari sumber radiasi dan luas lapangan radiasi 30 cm x 30 cm dalam simulasi DOSXYZnrc. Dalam simulasi sumber dianggap sebagai berkas paralel dan tegak lurus terhadap permukaan detektor. Pada pengukuran ini, nilai hamburan nilainya kecil sehingga dapat dianggap diabaikan dan tidak mempengaruhi dosis pada TLD 100. Hasil simulasi menunjukkan bahwa respon dosis TLD sangat tergantung pada variasi energi berkas, nomor atom efektif (Zeff),and komposisi material TLD. Selain itu, kemampuan absorpsi TLD juga dipengaruhi oleh ketebalannya.

The study of the influence energy in the range of 10 KeV to 1500 KeV to a dose response of thermoluminescence dosimeter (TLD) 100 LiF : Mg Ti. The study was done using Monte Carlo Simulation with DOSXYZnrc code has been done. The TLD was simulated took placed in the air medium with source to object distance of 100 cm from the radiation source and filed size of 30 cm x 30 cm. The geometry of radiation sources was assumed as parallel beams and perpendicular with detector surface. In the calaculation, the the scattering in air is very small so it was neglected and did not affect the dose to the TLD 100. The simulation results indicated that the TLD’s response depend on the energy of beams, effective atomic number and compound composition of TLD. On the other hand, the absorption of TLD is also affected by its thickness."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S45391
UI - Skripsi Membership  Universitas Indonesia Library
cover
Syaifulloh
"Pengukuran dalam radioterapi untuk perhitungan dosis seperti percentage depth dose (PDD) dilakukan dalam fantom air yang memiliki densitas homogen, dengan densitas hampir sama densitas otot (1 g/cm3). Pada perlakuan radioterapi seperti pada kanker paru, berkas radiasi melewati material yang tidak homogen yaitu otot, tulang dan paru itu sendiri yang berakibat pada perubahan PDD, sehingga perlu pengukuran pada medium inhomogen seperti pada fantom rando.
Tujuan penelitian ini adalah untuk mengukur distribusi dosis pada paru dengan simulasi perlakuan radioterapi pasien kanker paru dengan fantom rando kemudian dibandingkan dengan hasil perhitungan TPS. Pengukuran distribusi dosis menggunakan TLD dan film Gafchromic. Untuk memperoleh distribusi dosis pada paru TLD diletakkan pada titik - titik yang berada pada bidang utama berkas dalam fantom rando. Pengukuran distribusi dosis dengan film dilakukan dengan meletakkan film Gafchromic diantara 2 irisan fantom rando. Pengukuran dilakukan untuk 3 lapangan, 5 x 5 cm2, 10 x 10 cm2, dan 15 x 15 cm2. Hasil pengukuran dengan film dan TLD kemudian dibandingkan dengan hasil perhitungan TPS.
Hasil penelitian menunjukkan persentase dosis pada berbagai kedalaman antara hasil pengukuran film Gafchromic dengan perhitungan TPS berbeda secara signifikan, dan semakin besar lapangan semakin besar deviasi. Hasil pengukuran dengan film gafchromic mendapatkan nilai deviasi persen dosis hingga 6 % untuk lapangan 5 x 5 cm2, 16 % untuk lapangan 10 x 10 cm2, dan 17% untuk lapangan 15 x 15 cm2. Untuk pengukuran dengan TLD deviasi persen dosis hingga 8% untuk lapangan 5 x 5 cm2, 11% untuk lapangan 10 x 10 cm2, 12% untuk lapangan 15 x 15 cm2 masing ? masing pada kedalaman 15 cm.

Measurements in radiotherapy for dose calculation as percentage depth dose (PDD) are done in a water phantom with homogeneous density (1 g/cm3). In the radiotherapy treatment such as lung cancer, the radiation beam passes through inhomogeneous materials i.e. muscle, bone and lung itself, which resulted change in PDD, so necessary measurements on inhomogeneous medium like the rando phantom.
The purpose of this study was to measure dose distribution in the lung with simulated radiotherapy treatment of lung cancer patients with a rando phantom and compared with the TPS calculation. Measurement of dose distributions is using TLD and gafchromic films. To obtain the dose distribution in the lung, TLD placed at the points located on the main field of the beam in the rando phantom. Field measurements were made for 3 field sizes, 5 x 5 cm2, 10 x 10 cm2, and 15 x 15 cm2. The results were then compared with the TPS calculation.
The results show the percentage dose at various depths between the measurement and TPS calculation differ significantly, and the larger the field the greater the deviation. Measurement using gafchromic film resulting in deviation in dose percentage reaching up to 6 % for 5 x 5 cm2 field size, 16 % for 10 x 10 cm2, and 17 % for the 15 x 15 cm2. For TLD measurement, deviation is up to 8% for 5 x 5 cm2 field size, 11% for 10 x 10 cm2, and 12% for 15 x 15 cm2 at 15 cm depth respectively.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
T35528
UI - Tesis Membership  Universitas Indonesia Library
cover
Agustina Dwi Prastanti
"Tujuan penelitian ini adalah untuk menganalisis perbedaan variasi nilai kuat arus tabung terhadap kejelasan anatomi tulang wajah dan dosis radiasi. Jenis penelitian ini adalah penelitian eksperimental. Data diambil dari empat variasi penggunaan nilai arus tabung (mA) 200 mA, 150 mA, 100 mA dan 50 mA dengan parameter yang lain konstan. Dosis radiasi diukur dengan CTDI. Gambar dinilai oleh responden yang terdiri dari 20 (duapuluh) Dokter Spesialis Radiologi yang tidak menyadari tentang pengaturan kuat arus tabung pada gambar yang dihasilkan. Kualitas gambar dianalisis dengan metode skoring pada 8 (delapan) kriteria anatomi. Palatum, struktur trabekula tulang dan kortex, sinus paranasal, dinding orbita lateral dan medial, orbital roof dan orbital floor, zygomatic, nasal cavity dan ethmoid dinilai dengan skor 1 jika tidak jelas, skor 2 jika jelas dan skor 3 jika sangat jelas. Tidak ada perbedaan yang signifikan pada keempat kelompok dalam menentukan kejelasan anatomi tulang wajah berdasarkan sistem skoring yang digunakan dalam penelitian ini. Dosis radiasi dari penilaian CTDI menunjukkan bahwa dosis dapat dikurangi sebesar 75% pada penggunaan kuat arus tabung 50 mA atau 11,40 mGy dari arus protokol standar 200 mA atau 45,61 mGy. Hal ini sangat penting untuk mengurangi resiko kebutaan pada lensa mata.

The purpose of this study was to analyze the differences in the variation of tube current of the clarity of the facial bones anatomy and radiation dose. This research is an experimental study. Data were taken from four variations use the value of tube current (mA) 200 mA, 150 mA, 100 mA and 50 mA with the other parameters constant. CTDI measured radiation dose. Images assessed by respondents consisted of 20 (twenty) Radiology Specialists who are unaware of the settings on the tube current of the resulting image. The image quality was analyzed by the method of scoring in 8 (eight) anatomical criteria. Palate, structure of trabecular bone and cortex, paranasal sinuses, lateral and medial orbital wall, orbital roof and orbital floor, zygomatic, nasal cavity and ethmoid assessed with a score of 1 if it is not obvious, a score of 2 if it is clear and score 3 if very clear. There is no significant difference in the four groups in determining the clarity of the facial bones anatomy based on the scoring system used in this study. Radiation dose from CTDI assessment showed that the dose can be reduced by 75% in the use of tube current of 50 mA or 11.40 mGy of 200 mA current standard protocol or 45.61 mGy. It is very important to reduce the risk of blindness in the eye lens.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2013
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Achmad Faturrahman Jundi
"Dosimetri berbasis pengukuran pencitraan single-time-point (STP) diperlukan dalam terapi radionuklida untuk mengurangi beban kerja dan beban pasien. Meski demikian, metode untuk menghitung simpangan baku dari time-integrated activity coefficient (TIAC) individu dari metode STP belum pernah dilaporkan dalam literatur. Studi ini bertujuan untuk memperkenalkan metode menggunakan Bayesian fitting (BF) untuk menghitung SB TIAC individu dalam dosimetri STP, serta menganalisis penggunaan data biokinetik dari populasi yang berbeda. Data biokinetik 177Lu-DOTATATE ginjal dari tujuh pasien yang diukur menggunakan SPECT/CT pada empat titik waktu diperoleh dari PMID33443063. Persamaan fitting menggunakan fungsi mono eksponensial. Bayesian fitting dengan metode varians relatif (BFr) dan varians absolut (BFa) digunakan untuk memperoleh TIAC kalkulasi (cTIAC) dari dosimetri STP. Performa metode STP dinilai melalui deviasi relatif (RD) antara cTIAC dengan rTIAC. Akurasi cTIAC dari metode BF dibandingkan terhadap akurasi metode STP dari studi Hänscheid. Data biokinetik 111In-DOTATATE dari PMID26678617 dilakukan crossed dan combined dengan data PMID33443063 untuk dianalisis perbedaannya dengan data awal (origin). Inspeksi visual dari fitting ATP menunjukkan hasil yang baik dengan CV dari parameter fitting <50%. Nilai RMSE dari %RD cTIAC untuk BFr, BFa dan metode Hänscheid masing-masing yaitu: 26.2%; 9.3%; dan 8.5%. SB dari cTIAC lebih besar dari rTIAC pada sebagian besar pasien. Nilai RMSE dari %RD untuk BF origin, crossed, dan combined masing-masing yaitu: 20.26%; 26.48%; dan 21.11%. Kesimpulannya, penelitian ini memperkenalkan metode BF untuk menghitung SB dari TIAC individu dalam dosimetri STP dengan tingkat akurasi yang baik. Penggunaan data populasi dari jenis radiofarmaka yang berbeda melalui metode combined tidak signifikan dalam mempengaruhi akurasi dosimetri STP. Metode BF dapat digunakan sebagai metode alternatif untuk analisis ketidakpastian dalam dosimetri STP.

Dosimetry method based on single-time-point (STP) imaging measurement is desirable in radionuclide therapy to reduce the workload and patient burden. Nevertheless, a method to calculate the standard deviation (SD) of the individual time-integrated activity coefficient (TIAC) from the STP method has never been reported in the literature. Therefore, this study aims to present a method based on the Bayesian fitting (BF) framework to calculate the SD of individual TIAC in the STP dosimetry, and to analyze the use of biokinetic data from different populations. Biokinetic data of 177Lu-DOTATATE in kidneys from seven patients measured by SPECT/CT at four-time points were obtained from PMID33443063. The mono exponential function was used for fitting. BF with relative (BFr) and absolute-based (BFa) variance methods were used to obtain the calculated TIACs (cTIACs) from the STP dosimetry. Performance of the STP method with BF methods was obtained by calculating the relative deviation (RD) between cTIACs and rTIACs. The accuracy of the cTIACs from the BF methods was compared to the accuracy of cTIACs from the STP method reported by Hänscheid. The 111In-DOTATATE biokinetic data from PMID26678617 were crossed and combined with PMID33443063 data to analyze the difference with the origin data. The visual inspection of ATP fittings showed a good fit for all patients with a CV of the fitted parameters <50%. The RMSE of cTIAC’s were 26.2% for BFr; 9.3% for BFa; and 8.5% for Hänscheid. The SD from cTIACs was greater than the rTIACs in most of the patients. The RMSE of %RD for BF origin, crossed, and combined were: 20.26%; 26.48%; and 21.11%, respectively. To conclude, this study introduces the BF method to calculate the SD of individual TIACs in STP dosimetry with good accuracy. The use of population data from different types of radiopharmaceuticals through the combined method did not significantly affect the accuracy of STP dosimetry. The BF method can be used as an alternative method for uncertainty analysis in STP dosimetry."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Ani Sulistyani
"Perhitungan dosis radiasi melalui keluaran metrik 3DRA hanya tersedia pada protokol kontrol kualitas pada CBCT untuk radiologi intervensional. Hal ini dianggap belum andal karena perputaran gantry pada prosedur 3DRA tidak satu lingkaran penuh seperti pada Computed Tomography (CT). Penelitian ini bertujuan untuk mengevaluasi distribusi dosis aksial untuk prosedur 3DRA menggunakan tiga dosimeter relatif: thermoluminescence dosimeter (TLD), Film Gafchromic® XR-QA2, dan Film Gafchromic® XR-RV3. Dosimeter yang terkalibrasi diletakan di dalam fantom in house berbentuk silinder dan dilakukan pengukuran pada pesawat angiografi Philips Allura Xper FD20 menggunakan tiga mode preset yang tersedia.
Hasil pengukuran menggunakan dosimeter relatif dibandingkan dengan hasil pengukuran menggunakan dosimeter absolut untuk mengetahui akurasinya. Dari pengukuran didapatkan bahwa distribusi dosis 3DRA tidak homogen pada seluruh penampang fantom in house. Nilai dosis paling besar berada posisi jam 3 dan jam 9 sedangkan nilai dosis paling rendah berada pada posisi jam 12. Di antara dosimeter yang digunakan, distribusi dosis aksial yang paling akurat diperoleh melalui pengukuran menggunakan Gafchromic® XR-RV3, yang ditunjukkan dengan nilai diskrepansi rata-rata sebesar 33,82%. Selain itu, pengukuran mode Cranial Stent pada posisi jam 12 menunjukkan diskrepansi terkecil, dengan nilai 9,10%.

The calculation of radiation dose for 3DRA output metrics is currently only available in quality control for cone-beam computed tomography (CBCT). This method is considered unreliable because the gantry rotation in the 3DRA procedure is not a full 360 degrees like in CBCT. The objective of this study is to determine the axial dose distribution during the 3DRA procedure using three different relative dosimeters: thermoluminescence dosimeter (TLD), Gafchromic® XR-QA2 Film, and Gafchromic® XR-RV3 Film. The calibrated dosimeters were placed within a cylindrical in-house phantom, and measurements were performed using a Philips Allura Xper FD20 angiography system (in three preset modes).
The output of measurements using a relative dosimeter were compared to those using an absolute dosimeter, with the aim of assessing the accuracy.  It was found that the axial dose distribution in the 3DRA procedure is not evenly distributed across the cross-sectional area of the in-house phantom. The highest dose values were observed at the 3 and 9 o'clock positions, while the lowest dose values were recorded at the 12 o'clock position. Among the dosimeters used, the most accurate axial dose distribution was obtained through measurements using Gafchromic® XR-RV3, as indicated by an average discrepancy value of 33.82%. Additionally, the cranial stent mode measurements at the 12 o'clock position showed the smallest discrepancy, with a value of 9.10%.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library