Hasil Pencarian

Ditemukan 6 dokumen yang sesuai dengan query
cover
Meidiono Untoro
Abstrak :
Peningkatan taraf hidup dan temperatur rata-rata yang tinggi di Indonesia membuat penggunaan elektronik pengkondisi udara meningkat. Hal tersebut akan bertolak belakang dengan usaha mewujudkan Indonesia hemat energi. Pemerintah mengeluarkan peraturan menteri ESDM nomor 7 tahun 2015 tentang penerapan standar kinerja energi minimum dan pencantuman label tanda hemat energi untuk AC dengan ruang lingkup maksimal 27.000 Btu/h jenis single split wall mounted. Prosedur mendapatkan label tanda hemat energi dengan persyaratan pengujian kinerja piranti pengkondisi udara yang mengacu kepada SNI 19-6713-2002 diadaptasi dari ISO 5151. Metode pengujian kinerja dapat dilakukan menggunakan metode entalpi udara. Rangkaian metode entalpi udara yang digunakan adalah tunnel. Rangkaian tunnel dengan udara dari piranti pengkondisi udara yang diuji dimasukan ke alat pengukur beban pendinginan kemudian udara dilepaskan ke ruang pengkondisian. Ruang pengkondisian merupakan ruang terisolasi dengan alat pengkondisi udara untuk mencapai kondisi standar pengujian. Kondisi standar pengujian untuk ruang pengkondisian piranti pengkondisi udara unit dalam 27°C dan RH 47% dan untuk unit luar 35°C dan RH tidak dipersyaratkan. Ruang pengkondisian dicapai kondisinya menggunakan alat pengkondisi ruangan yang dilengkapi coil pendingin, coil pemanas, dan penambah kelembaban hanya pada ruang unit dalam. Sistem refrigerasi dari alat pengkondisi ruangan pengkondisian menggunakan air cooled chiller dengan sistem heat recovery. Sistem heat recovery sebagai suplai untuk air panas yang digunakan coil pemanas. Sistem kontrol alat pengkondisi udara ruang pengkondisian menggunakan laju aliran air dingin coil pendingin, air panas coil pemanas, dan mist air alat penambah kelembaban sebagai variabel kapasitas pendinginan, pemanasan dan penambah kelembaban. ......Lifestyle and the high average temperature in Indonesia makes use of air conditioning increases. It would be contrary to the energi saving effort towards Indonesia. The government released rules of minister ESDM number 7 2015 about implementation standard of energi efficiency and energi labelling for AC unit with maximum capacity 27.000 Btu/h single split wall mounted type. The procedure to get a label and requirement of testing AC has refer to SNI 19-6713-2002 which adopted from ISO 5151. Method of testing AC can be done using air enthalpy method. Using tunnel air enthalpy test method arrangement. In tunnel air ethalpy, air from testing unit entered to the cooling load measuring instruments and then released into the climatic chamber. Climatic chamber is a insulated chamber with air conditioning apparatus to reach standard test condition. Standard testing condition for climatic chamber for indoor unit in 27 °C with RH 47% and for the outdoor unit 35 °C with RH not required. The condition is achived using a air conditioning apparatus that is equipped with cooling coil, heating coil, and humidifer only for indoor unit testing. Refrigeration system for using air cooled chiller with heat recovery system. Heat recovery system as a supply of hot water used for heating coil. The control system of room air conditining apparatus using a flow rate of chilled water cooling coil, hot water heating coil, and air mist moisture as a variable capacity cooling, heating, and humidification.
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64984
UI - Skripsi Membership  Universitas Indonesia Library
cover
Susan Brades, supervisor
Abstrak :
Kualifikasi kinerja bertujuan untuk memverifikasi bahwa fasilitas, sistem dan peralatan yang telah terpasang dan difungsikan, bekerja secara efektif serta memberikan hasil yang konsisten. Dalam aktivitasnya, industri farmasi wajib menerapkan program kontrol, kualifikasi, dan validasi pada setiap aspek yang dapat berpengaruh terhadap kegiatan produksi dan mutu obat yang dihasilkan termasuk pada sarana penunjang kritis. Adapun salah satu sarana penunjang kritis di industri farmasi yaitu Sistem Tata Udara (HVAC). Laporan ini berisi tentang metode kualifikasi kinerja sistem HVAC terhadap parameter kritis yang dapat mempengaruhi kualitas produk selama proses produksi di Ruang Produksi Steril Non-Cephalosporin PT. Mahakam Beta Farma. ......Performance qualification aims to verify that facilities, systems and equipment that have been installed and functioned, work effectively and provide consistent results. In its activities, the pharmaceutical industry is required to implement control, qualification and validation programs in every aspect that can affect production activities and the quality of drugs produced, including critical supporting facilities. One of the critical supporting facilities in the pharmaceutical industry is the Air Conditioning System (HVAC). This report contains the method of performance qualification of the HVAC system for critical parameters that can affect product quality during the production process in the Non-Cephalosporin Sterile Production Room of PT Mahakam Beta Farma.
Depok: Fakultas Farmasi Universitas Indonesia, 2022
PR-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Edwards, Harry J.
New York: McGraw-Hill, 1980
697 EDW a
Buku Teks  Universitas Indonesia Library
cover
Daniel Wijaya
Abstrak :
Sistem tenaga listrik di seluruh dunia menghadapi masalah teknis dalam pengoperasian, perencanaan, dan pengontrolan agar suplai tenaga listrik menjadi lebih efektif dan efisien. Namun, daya yang dikonsumsi oleh konsumen tidaklah selalu konstan, apalagi khususnya daya yang dipakai oleh pendingin ruangan. Ketika suhu meningkat, tentunya mengakibatkan banyak orang menggunakan pendingin ruangan dengan suhu yang lebih rendah dan ini berarti mengakibatkan daya yang dikonsumsi pun meningkat, begitu juga sebaliknya. Agar mencapai tujuan tersebut, diperlukan suatu peramalan beban yang tepat dengan tingkat kesalahan yang sangat kecil. Peramalan yang akan dilakukan dalam skripsi ini adalah peramalan jangka pendek dengan rentang waktu tiap satu jam dengan membuat pemodelan antara daya yang dikonsumsi konsumen tiap jam sebagai fungsi temperatur dan beban sebelumnya. Data beban dan temperatur yang digunakan untuk membuat pemodelan adalah data selama tahun 2010 yang didapat dari PLN dan BMKG. Pemodelan yang akan dibuat berupa pemodelan linier dengan satu varibel terikat dan empat belas variabel bebas. Koefisien dari pemodelan dicari dengan menggunakan metode kuadrat terkecil analisis regresi berganda. Hasil dari pemodelan yang telah dibuat menunjukan tingkat kesalahan rata-rata yang cukup kecil setiap harinya, yaitu sekitar 2% untuk hari biasa dan 5% untuk libur hari raya. ......Power system in overall the world is facing technique problems in operating, scheduling, and controlling in order power supply can more effective and efficient. In contrast, power consumed by consumers is not constant, especially power used by air conditioner. When the temperature increase, it makes most people use air conditioner by low temperature and it means that power consumed by the air conditioner is increase, and also the reverse. To achieve the purpose, needed an accurate load forecasting with very low error. Forecasting that has been done in this undergraduate thesis is short term forecasting with one hour interval by constructing the model between consumer power consumption every hour as the last temperature and load function. Load and temperature data used to make the modeling is data obtained during 2010 from PLN and BMKG. Modeling that will be made is linear modeling with one independent variable and fourteen dependent variable. The coefficients of modeling were searched using the least squares method of multivariate regression analysis. The result of the modeling that has been created showing the average error rate is small enough each day, about 2% for weekdays and 5% for the holiday feast.
Depok: Fakultas Teknik Universitas Indonesia, 2011
S87
UI - Skripsi Open  Universitas Indonesia Library
cover
Rachmat
Abstrak :
ABSTRAK
Sistem tata udara pada ruang operasi berperan penting dari segi kenyamanan tim bedah dan pasien. Selain dari segi kenyamanan, sistem tata udara juga memiliki fungsi untuk mengurangi jumlah partikel di udara ruang operasi selama proses pembedahan berlangsung. Pada ruang operasi yang diteliti didapat banyak parameter-parameter yang tidak memenuhi standar ruang operasi menurut ASHRAE 170 dan ISO 14644-1 sehingga dibutuhkan perancangan ulang sistem tata udara yang baru. Sistem tata udara yang dirancang harus memenuhi semua standar parameter ruang operasi yang berlaku seperti kebutuhan udara segar, suhu, tekanan, kecepatan udara diatas meja operasi, dan tingkat konsentrasi partikel kontaminan. Pentlitian ini menggunakan program FloVent 8.2 untuk melakukan simulasi terkait parameter ruang operasi baik pada kondisi ruang operasi existing maupun kondisi hasil desain. Hasil simulasi selanjutnya dibandingkan dan terlihat bahwa pola aliran udara pada ruang operasi existing tidak terlalu baik dalam penyapuan partikel keluar ruangan sehingga berdampak pada tingginya konsentrasi partikel yang terdisipasi di udara. Selain pola aliran udara, kondisi suhu dan kenyamanan termal pengguna ruangan masih belum sesuai dengan standar yang berlaku dan telah terjadi penurunan efisiensi HEPA filter menjadi 93 terhadap partikel ukuran 0.3 m. Sedangkan ruang operasi hasil desain menunjukan pola aliran udara laminar yang cukup baik menyapu partikel keluar ruangan. Hasil simulasi juga menunjukan bahwa sistem tata udara hasil desain telah memenuhi parameter ruang operasi yang diatur dalam standar ASHRAE 170 dan ISO 14644-1. Kata kunci: ASHRAE 170; HEPA filter; ISO 14644-1; parameter ruang operasi; pola aliran udara; ruang operasi; sistem tata udara
ABSTRACT
Air conditioning system for operating room has an important rule for surgeon and patient comfortable. Beside from comfortable side, air conditioning system has another function to decrease airborne particle in operating room during operation. At the operating room that researched, there are many parameters that are not appropriate with operating room standard based on ASHRAE 170 and ISO 14644 1, so that we need to design a new air conditioning system for the operating room. The new design has to meet all the operating room parameter standards prevail, such as fresh air needed, temperature, pressure, air speed above operating bed, and airborne contamination level. The research uses FloVent 8.2 software program to do simulation related to the operating room parameters whether in existing condition and also the new design. The simulation results than compared, and we can see that airflow pattern in existing condition operating room is not too good to sweep airborne particles out of the room, so that makes the airborne particle dissipated in the air of the operating room. Beside the airflow pattern, temperature condition and the occupation thermal comfort do not meet the standard too and the HEPA filter efficiency has decline to 93 for particle size 0.3 m. While the new operating room design shows the laminar airflow pattern that good enough to sweep particles out of the room. The simulation results show that the new air conditioning system has statisfy the operating room parameters which regulated in ASHRAE 170 and ISO 14644 1 standard. Keywords Air conditioning system airflow pattern ASHRAE 170 HEPA filter ISO 14644 1 operating room operating room parameters.
2017
S68596
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sandi Mulya
Abstrak :
Listrik merupakan suatu kebutuhan yang tidak dapat dilepaskan dari kehidupan manusia sehari-hari. Untuk itu suatu gedung membutuhkan instalasi listrik. Gedung S Fakultas Teknik Universitas Indonesia merupakan gedung yang diperuntukkan sebagai tempat belajar mengajar bagi mahasiswa dan dosen. Gedung yang sudah berdiri sejak beberapa tahun yang lalu ini dirasa perlu untuk dilakukan audit terutama audit kualitas daya pada panel AC karena merupakan beban terbesar yang ada di gedung S. Audit kualitas daya ini untuk memberikan rekomendasi agar instalasi yang digunakan sesuai yang diharapkan. Hasil audit visual menunjukkan bahwa kondisi panel tidak perlu dilakukan perawatan atau pergantian untuk sekarang ini karena masih terlihat rapi. Hasil pengukuran menunjukkan beberapa parameter kualitas daya telah memenuhi standar seperti tegangan pada rentang 213.03-220.37 V, arus pada rentang 49.6-159.8 A, frekuensi pada rentang 49.867-50.153 Hz, sedangkan beberapa tidak memenuhi standar seperti harmonik dimana IHDi orde 3 bernilai diatas 7% dan faktor daya ≤ 0.85. ......Electricity is a need that cannot be separated from everyday human life. For that a building requires electrical installation. Building S, Faculty of Engineering, University of Indonesia is a building intended as a place of teaching and learning for students and lecturers. The building that has been established since decades ago is deemed necessary to conduct an audit, especially the AC installation audit because it is the biggest burden in the S building. The AC installation audit is to provide recommendations for the installation to be used as expected. The results of monitoring indicate that the panel conditions do not need to be treated or changed for now because it still looks neat. The measurement results show several power quality parameters that meet standards such as voltages in the range 213.03-220.37 V, currents in the range 49.6-159.8 A, frequencies in the range 49.867-50.153 Hz, while some do not meet standards such as harmonics where IHDi is 3 abov power factor ≤ 0.85.
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library