Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Agrippina Maria Winardi
"

Latar belakang: Stabilitas sekunder memiliki pengaruh besar terhadap oseointegrasi yang pada akhirnya akan mempengaruhi keberhasilan perawatan implan. Desain thread implan merupakan salah satu faktor penting yang mempengaruhi stabilitas implan. Namun belum banyak penelitian yang menganalisa pengaruhnya terhadap stabilitas sekunder. Metode: Penelitian ini merupakan penelitian kuasi eksperimental yang mengevaluasi stabilitas sekunder 44 buah implan dengan jenis implan BL (Bone Level) dan BLT (Bone Level Tapered) masing-masing berjumlah 22 buah implan. Stabilitas implan diukur sebanyak 3 kali pada setiap implan menggunakan alat RFA (Resonance Frequency Analysis). Rerata nilai ISQ (Implant Stability Quotient) akan didapat pada saat pemasangan implan, 1 bulan, dan 2 bulan setelah pemasangan implan. Hasil: Hasil menunjukkan bahwa terdapat perbedaan nilai ISQ yang signifikan antara nilai saat pemasangan implan dibandingkan nilai saat kontrol 1 bulan serta kontrol 2 bulan setelah pemasangan baik pada kelompok BL maupun BLT dengan nilai p < 0,05. Namun, tidak ada perbedaan nilai ISQ yang signifikan antara implan berdiameter 4,1 mm dan 4,8 mm pada jenis implan BL maupun BLT naik pada saat pemasangan implan, saat kontrol 1 bulan, dan kontrol 2 bulan setelah pemasangan dengan nilai p = 0,21. Kesimpulan: Jenis desain thread implan bone level tidak mempengaruhi stabilitas sekunder. Faktor lain seperti diameter implan juga tidak mempengaruhi nilai stabilitas sekunder baik pada jenis implan BL maupun BLT.

 


Background: Secondary stability greatly influences osseointegration, which ultimately affects the success of implant treatment. Though implant thread design is one important factor influencing implant stability, not many studies have analyzed its impact on secondary stability. Methods: This quasi experimental study involving 44 implants evaluated the biological stability of threaded implants with cylindrical (bone-level; BL) and tapered (bone-level tapered; BLT) designs. Implant stability was evaluated for each implant at 3 time parameters using resonance frequency analysis. A mean implant stability quotient (ISQ) value was calculated for each measurement time. Results: A significant increase in the ISQ value was found at each time parameter consecutively in both implant design groups (P < 0.05). No significant difference was noted in ISQ value between the groups at all 3 time parameters (P = 0.05). There was also no significant difference in the ISQ value at all 3 time parameters between implants with diameters of 4.1 mm and 4.8 mm in the BL and BLT implant groups (P = 0.21). Conclusion: The implant thread designs of BL and BLT implants did not affect the secondary stability. Factors such as implant diameter also did not affect the secondary stability in either implant group.

 

"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2020
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Randi Dias
"Latar belakang: Disfagia merupakan salah satu tanda yang dapat menggambarkan hipofungsi oral pada lansia. Kondisi ini biasanya tidak diperhatikan dan tidak disadari oleh lanjut usia (lansia) serta keluarganya, akibatnya menyebabkan kecacatan dan kematian. Eating Assesment Tool (EAT-10) merupakan alat ukur pemeriksaan awal/skrining terhadap keluhan disfagia. Namun, alat ukur tersebut belum tersedia dalam Bahasa Indonesia. Penelitian hubungan faktor usia, jenis kelamin, pendidikan, dan jumlah penyakit sistemik terhadap disfagia pada lansia masih terbatas sehingga perlu diteliti lebih lanjut. Tujuan: Penelitian ini untuk mendapatkan EAT-10 berbahasa Indonesia (EAT-10-ID) sebagai alat skrining disfagia yang valid dan reliabel pada lansia. Selanjutnya dianalisis hubungan antara faktor sosiodemografi dan jumlah penyakit sistemik dengan disfagia serta mengetahui faktor yang paling berperan terhadap disfagia. Metode: Dilakukan adaptasi lintas budaya EAT-10 dengan metode translate-backward translate. Selanjutnya dilakukan uji validitas dan reliabilitas EAT-10-ID, dianalisis hubungan antara usia, jenis kelamin, pendidikan dan jumlah penyakit sistemik dengan disfagia serta dianalisis faktor yang paling berperan terhadap disfagia pada 121 responden laki-laki dan perempuan berusia ≥ 60 tahun yang mampu berkomunikasi secara lisan atau tulisan dengan bahasa Indonesia. Hasil: Validitas isi dan validitas muka EAT-10-ID terpenuhi dengan baik. Reliabilitas konsistensi internal baik (Cronbach's alpha=0,896) dan reliabilitas konsistensi eksternal sangat baik (ICC =0,935). Hasil uji validitas konvergen menunjukkan nilai yang baik antara EAT- 10-ID dan kualitas hidup (GOHAI) (r =-0,449; p=0,000). Selain itu, EAT-10-ID memiliki hubungan dengan 3 Oz Water Swallow Test sebagai alat ukur gejala klinis disfagia (p=0,00) yang berarti EAT-10-ID memiliki validitas konstruk yang baik dalam membedakan responden yang memiliki risiko dan tidak berisiko disfagia. Titik potong EAT-10-ID yang menunjukkan individu memiliki disfagia dengan skor 3 dengan nilai sensitivitas 94,7% dan spesifisitas 97,1%. Dari keempat variabel yang dianalisis, usia (OR=2,023) dan jumlah penyakit sistemik (OR=2,261) memiliki hubungan bermakna dengan disfagia (p ≤0,05) serta merupakan faktor yang paling berperan terhadap terjadinya disfagia Kesimpulan: EAT-10-ID merupakan alat ukur yang valid dan reliabel untuk pemeriksaan awal/skrining disfagia dengan titik potong 3. Usia dan jumlah penyakit sistemik merupakan faktor yang paling berperan terhadap terjadinya disfagia.

Introduction: Dysphagia is one of the signs that can describe oral hypofunction in the elderly. This condition is usually not noticed nor realized by the elderly and their families, resulting in disability and death. The Eating Assessment Tool (EAT- 10) is an initial examination/screening tool for dysphagia complaints. However, this measurement tool is not yet available in the Indonesian language. Studies on the relationship between age, gender, education, and the number of systemic diseases towards dysphagia in the elderly are still limited, so further research is needed. Objective: To obtain a valid and reliable EAT-10 in the Indonesian language (EAT-10-ID) as a dysphagia screening tool in the elderly and to analyze the relationship between sociodemographic factors and the number of systemic diseases with dysphagia and find out which factors contribute the most to dysphagia. Method: A cross-cultural adaptation of EAT-10-ID was carried out using the backward-translation method. The EAT-10-ID was given to 121 male and female respondents, aged ≥ 60 years who were able to communicate in Indonesian both orally and in writing in order to test for validity and reliability. Subsequently, the EAT-10-ID was analyzed for the relationship between age, sex, education, and the number of diseases with dysphagia. Moreover, factors that contributed the most to dysphagia were also analyzed. Results: The EAT-10-ID had achieved good content validity and face validity. Internal consistency reliability was good value (Cronbach's alpha=0.896) and excellent external consistency reliability (ICC =0.935). The convergent validity test showed a good value between EAT-10-ID and quality of life (GOHAI) (r = -0.449; p= 0.000). In addition, the EAT-10-ID showed a correlation with the 3 Oz Water Swallow Test as the clinical symptom measurement tool for dysphagia (p=0.000), meaning that the EAT-10-ID had a good construct in distinguishing respondents whether they risk having dysphagia or not. The EAT-10-ID cut off score of 3 which indicated an individual had dypshagia, sensitivity value of 94.7% and specificity value of 97.1%. Of the four variables analyzed, age (OR=2.023) and number of systemic diseases (OR= 2,261) had a significant relationship with dysphagia (p ≤0.05) and was the most contributing factor to dysphagia. Conclusion: The EAT-10-ID with cut off score of 3 is a valid and reliable measurement tool for the initial examination/screening of dysphagia. The age and number of systemic diseases are the factors that contribute the most to the occurrence of dysphagia."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2023
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Melati Fitria Putri
"Latar belakang: Indeks Etiologi Gangguan Sendi Temporomandibula (GSTM) sebelumnya dibuat dengan Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) yang merupakan baku emas alat diagnostik TMD. Saat ini baku emas tersebut telah disempurnakan menjadi Diagnostic Criteria for Temporomandibular Disorders (DC/TMD). Belum ada penelitian yang menguji akurasi Indeks Etiologi GSTM dengan baku emas DC/TMD. Tujuan: Mencari nilai titik potong baru Indeks Etiologi GSTM dan menguji akurasinya menggunakan baku emas DC/TMD. Metode: Penelitian ini adalah uji diagnostik dengan desain potong lintang yang dilakukan pada 171 subjek menggunakan pengisian Indeks Etiologi GSTM dan pemeriksaan klinis DC/TMD. Hasil: Analisis kurva Receiver Operating Characteristic (ROC) menghasilkan nilai Area Under the Curve (AUC) sebesar 80,5% (95% CI: 73,7-87,4%). Nilai titik potong optimal yaitu 6 dengan sensitivitas 67,9% dan spesifisitas 86,2%. Nilai Positive Predictive Value (PPV) 82,6%, Negative Predictive Value (NPV) 73,7%, Likelihood Rasio Positive (LR+) 4,92, dan Likelihood Rasio Negative (LR-) 0,37. Kesimpulan: Indeks Etiologi GSTM yang diuji dengan DC/TMD sebagai baku emas memiliki akurasi yang baik untuk digunakan sebagai alat skrining TMD. Nilai titik potong 6 sebagai batas antara risiko tinggi dan risiko rendah GSTM.

Background: The Temporomandibular Etiology Index was previously made with the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) as the gold standard of TMD diagnostic tool. Now the gold standard has been refined to become the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD). There are no studies that have tested the accuracy of the Temporomandibular Etiology Index with the DC/TMD gold standard. Purpose: To determine the new cut-off point of the Temporomandibular Etiology Index and test its accuracy using the DC/TMD gold standard. Methods: This study design was a cross-sectional diagnostic test conducted on 171 subjects using Temporomandibular Etiology Index questionnaires and DC/TMD clinical examination. Results: Receiver Operating Characteristic (ROC) curve analysis resulted in an Area Under the Curve (AUC) value of 80.5% (95% CI: 73.7-87.4%). The optimal cut-off point was 6 with 67.9% sensitivity and 86.2% specificity. Positive Predictive Value (PPV) 82.6%, Negative Predictive Value (NPV) 73.7%, Positive Likelihood Ratio (LR +) 4.92, and Negative Likelihood Ratio (LR-) 0.37. Conclusion: Temporomandibular Etiology Index has been tested with DC/TMD as the gold standard and has a good accuracy to be used as a TMD screening tool. The cut-off point of 6 is the boundary between high and low risk of temporomandibular disorders."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library