Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 2 dokumen yang sesuai dengan query
cover
Indah Rahma Apriani
Abstrak :
Penelitian ini bertujuan untuk mengembangkan pemodelan physiologically-based pharmacokinetic (PBPK) yang mampu menggambarkan biodistribusi dan sifat farmokinetis dari pembrolizumab dan nivolumab dalam tubuh, dengan menggunakan data biodistribusi dari 89Zr-pembrolizumab dan 89Zr-nivolumab  pada Mencit yang telah dicangkokan periferal limfosit manusia (hu-PBL-SCID) (PMID: 27493273 & PMCID: PMC5700850)serta data biodistribusi 89Zr-pembrolizumab pada pasien Non-small cell lung cancer (NSCLC) (PMID: 34272316). Pemodelan PBPK mencakup kompartmen organ dan jaringan seperti, paru-paru, hati, limpa, ginjal, otak, sumsum tulang, kelenjar ludah, yang secara anatomis dihubungkan melalui aliran darah dan aliran limfatik. Kompartemen organ akan dibagi menjadi tiga sub-kompartemen, yaitu ruang vaskular, ruang interstisial dan ruang endosomal, dengan mempertimbangkan adanya ikatan antara pembrolizumab dengan FcRn pada ruang endosomal. Parameter yang diestimasi dalam pemodelan PBPK merupakan parameter drug-dependent, diantaranya adalah faktor modulasi endositosis (F2) dan modulasi eksositosis (F3) pada ruang endosomal, serta faktor modulasi dari aliran transkapiler antara ruang vaskular dan ruang interstisial (MK). Pemodelan akan dievaluasi menggunakan metode Goodness of Fit, yaitu melalui evaluasi visual grafik pemodelan dan nilai coefficient of variation (CV) dari parameter yang diestimasi (%CV < 50%). Nilai estimasi parameter F2 [%CV] didapatkan untuk pembrolizumab sebesar 0,021 [6,10] dan untuk nivolumab bernilai 0,034 [9,44], sedangkan faktor modulasi eksositosis (F3) tidak mempengaruhi kurva akumulasi konsentrasi hasil pemodelan sehingga nilainya di fiksasi pada angka 1. Meskipun MK merupakan parameter drug-dependent, sesuai dengan literatur yang menyatakan bahwa besar aliran transkapiler pada organ hati dan limpa kemungkinan berbeda dengan organ lainnya, sehingga dalam penelitian didapatkan estimasi nilai MK yang sama untuk hati dan Limpa namun berbeda dengan organ lainnya, untuk pembrolizumab nilai MK [%CV] berada dalam rentang 18,76-28,77 [1,82-4,89], sedangkan untuk nivolumab berada dalam rentang 27,46-30,69 [4,99-5,61]. Untuk menganalisa efek radiofarmaka antibodi pada organ at risk, diperlukan informasi nilai Area under curve (AUC) yang didapatkan melalui pemodelan PBPK final. Dari hasil perbandingan nilai AUC akumulasi nivolumab lebih tinggi  dibandingkan dengan pembrolizumab. ......This study aims to develop a physiologically-based pharmacokinetic (PBPK) model to describe the biodistribution and pharmacokinetic properties of pembrolizumab and nivolumab in the body. The biodistribution data of 89Zr-pembrolizumab and 89Zr-nivolumab in mice that have been grafted with human’s peripheral lymphocytes (hu- PBL-SCID) (PMID: 27493273 & PMCID: PMC5700850) and the 89Zr-pembrolizumab biodistribution data in Non-Small Cell Lung Cancer (NSCLC) patients (PMID: 34272316) were used for PBPK modeling. This modeling was done through the organ and tissue compartments, such as the lung, liver, spleen, kidney, brain, bone marrow, and salivary glands, which were anatomically connected through blood flow and lymphatic flow. The organ compartment was divided into three sub-compartments, namely the vascular space, the interstitial space, and the endosomal space, while considering the binding between the monoclonal antibody (mAb) and FcRn occurred in the endosomal space. The drug-dependent parameters, such as modulation factors of endocytosis (F2) and modulation of exocytosis (F3) in the endosomal space, as well as modulation factors of transcapillary flow between the vascular space and the interstitial space (MK), were estimated in the model. Modeling will be evaluated using the Goodness of Fit method, through visual evaluation of the modeling graph and the coefficient of variation (CV) value of the estimated parameters (%CV <50%). The estimated value of the F2 parameter [%CV] obtained for pembrolizumab was 0.021 [6.10] and nivolumab was 0.034 [9.44], while the exocytosis modulation factor (F3) did not affect the concentration accumulation curve modeled, so its value was fixed at number 1. Even though MK is a drug-dependent parameter, a literature states that the amount of transcapillary flow in the liver and spleen may be different from other organs, so this study also found that the estimated MK value was the same for the liver and spleen but different from other organs. for pembrolizumab the value of MK [%CV] was in the range of 18.76-28.77 [1.82-4.89], while for nivolumab it was in the range of 27.46-30.69 [4.99-5.61]. To analyze the effects of antibody radiopharmaceuticals on Organs at Risk (OARs), the information on the value of the Area Under the Curve (AUC) obtained through the final PBPK modeling is needed. From the comparison results, the accumulated AUC value of nivolumab was higher than that of pembrolizumab.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Indah Rahma Apriani
Abstrak :
ABSTRAK Salah satu faktor yang mempengaruhi kualitas citra SPECT adalah geometri, seperti posisi dan ukuran obyek deteksi, dan juga geometri obyek-detektor dalam akuisisi SPECT. Kualitas citra SPECT dievaluasi dengan FWHM sebagai parameter resolusi citra, dan kontras. Tujun penelitian adalah menganalisa kemampuan SPECT dalam mengatasi pengaruh geometri obyek deteksi. Penelitian dilakukan pada fantom in-house dengan material penyusun berupa gondorukem, lilin cecek malam dan tepung beras. Variasi geometri yang dilakukan selama penelitian berupa variasi posisi dan ukuran obyek deteksi (vial berdiameter 11, 8, 6, 4 mm) yang berupa vial silinder dari pipa akrilik. Dari variasi tersebut akan terlihat seberapa besar pengaruh letak obyek di dalam fantom pada kualitas citra yang didapatkan, serta seberapa baik SPECT dapat meminimalisir efek geometri posisi obyek deteksi. Hasil penelitian yang dilakukan, didapatkan bahwa ukuran obyek minimum untuk semua variasi posisi ialah 11 mm dengan nilai rerata CF sebesar 1,03 ± 0,08. hasil ini terbukti independen terhadap aktivitas obyek deteksi dengan nilai CF yang cenderung konstan pada ketiga variasi rasio konsentrasi aktivitas obyek yang dilakukan terhadap semua posisi obyek.
ABSTRACT One of the factors that influence SPECT image quality is geometry, such as the position and size of the object of detection, as well as the geometry of the objects in the acquisition of SPECT. SPECT image quality is evaluated by FWHM as an image resolution parameter, and contrast. The aim of this research is to analyze the SPECT ability in overcoming the influence of the geometry of the object of detection. The study was conducted on in-house phantoms with constituent materials in the form of gondorukem, evening cecek candles and rice flour. The geometry variations carried out during the study were variations in the position and size of the object of detection (vials 11, 8, 6, 4 mm) in the form of cylindrical vials of acrylic pipes. From these variations will be seen how much influence the location of the object in the phantom on the quality of the image obtained, and how well SPECT can minimize the geometric effects of the position of the object of detection. The results of the research conducted, it was found that the minimum object size for all position variations was 11 mm with an average value of CF of 1.03 ± 0.08. This result is proven independent of the object detection activity with CF values ​​that tend to be constant in all three variations in the concentration of object activity performed on all object positions.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library