Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 93 dokumen yang sesuai dengan query
cover
Alberto Paulo Cercado
"Biodiesel was produced using three different alkali catalysts, namely KOH, NaOH and LiOH. The aim of the study was to determine which of these is the most effective as far as Fatty Acid Methyl Ester (FAME) yield is concerned in producing biodiesel from microalgae. Three different transesterification processes were considered; conventional, microwave-assisted and ultrasound-assisted. The study was able to show that NaOH and KOH generated far better FAME values compared to LiOH in all three transesterification processes. The introduction of microwave or ultrasound in the transesterification slightly increased the FAME yield by 5% and cut the reaction time by 50%. The best FAME yield was attained when the optimum process parameters were a methanol to oil ratio of 12:1; a catalyst load of 2% for NaOH and 3% for KOH; a reaction time of 12 minutes; and a microwave output power rate of 600 watts."
Depok: Faculty of Engineering, Universitas Indonesia, 2018
UI-IJTECH 9:4 (2018)
Artikel Jurnal  Universitas Indonesia Library
cover
Cura, Jose Luís del
"This book offers a practical approach to the world of diagnostic ultrasound. It has been structured in a reader-friendly, case-based format that makes it easy and enjoyable to learn the basics of the applications and interpretation of ultrasound. Each case includes illustrations, descriptions of the imaging findings, and technical details and serves to identify the essential imaging features of the pathology under consideration, thus assisting the reader in the diagnosis of similar cases. The book is divided into 17 short chapters that review the most important areas of ultrasound application and also document the latest advances in the use of contrast and interventional ultrasound. The authors treat every topic from a “how to do it” perspective with the aim of imparting their wide experience in use of the technique. "
Berlin : Springer, 2012
e20426088
eBooks  Universitas Indonesia Library
cover
Michelle Nasseri
"Mamografi merupakan pemeriksaan baku emas dan merupakan modalitas satu-satunya untuk skrining payudara perempuan. Namun efektivitas mamografi menurun terutama pada payudara berdensitas padat. Handheld ultrasonography (HHUS) sering diperlukan sebagai pelengkap mamografi dan dapat meningkatkan sensitivitas dan spesifisitas untuk deteksi kanker payudara berdensitas padat. Automated breast ultrasound (ABUS) merupakan modalitas relatif baru dengan beberapa kelebihan dibandingkan dengan HHUS antara lain reproducible, variabilitas yang rendah, waktu akuisisi lebih singkat dan konsisten, serta ukuran transduser yang lebar sehingga mencakup payudara lebih menyeluruh dan dapat melakukan karakterisasi lesi yang ukurannya melebihi lebar transduser HHUS dengan lebih baik. Saat ini penggunaan ABUS belum merata di rumah sakit di Indonesia, dan penelitian mengenai ABUS masih terbatas, sehingga perlu dilakukan penelitian mengenai ABUS dibandingkan dengan modalitas lain secara lebih obyektif. Tujuan : Penelitian ini bertujuan untuk mengetahui kesesuaian temuan, morfologis, dan lokasi lesi di payudara berdasarkan densitas mamografi dan HHUS dengan densitas mamografi dan ABUS. Metode: Dilakukan pemeriksaan payudara menggunakan mamografi, HHUS GE tipe Logic S8 dengan transduser linear 7-12 MHz, dan ABUS GE Invenia dengan transduser konkaf linear 6-12 MHz. Seluruh pemeriksaan HHUS dan ABUS dilakukan sendiri oleh peneliti di Departemen Radiologi RSCM, dan dikonfirmasi oleh Dokter Spesialis Radiologi konsultan payudara bersertifikasi ABUS untuk menentukan ada atau tidaknya lesi, morfologis, dan lokasi lesi. Kesesuaian hasil pemeriksaan mamografi-ABUS dan mamografi HHUS dianalisis menggunakan uji Mc Nemar. Hasil: Terdapat 30 subyek penelitian dan diperoleh 48 sampel payudara, dengan rentang usia 36-66 tahun (rerata ± SD 51,4 ± 8,5 tahun). Dalam menentukan ada tidaknya lesi, pemeriksaan mamografi- HHUS dan mamografi-ABUS memiliki kesesuaian dengan level sedang (moderate agreement), nilai Kappa 0,43 dan 0,49 (p 0,002 dan p 0,001); dalam menentukan morfologis lesi memiliki kesesuaian dengan level sedang (moderate agreement) dengan nilai Kappa 0,51 dan 0,43 (p 0,000 dan 0,000); serta dalam menentukan lokasi lesi memiliki kesesuaian dengan level fair agreement dengan nilai Kappa 0,37 dan 0,36 (p 0,000 dan 0,000). Simpulan: Kombinasi mamografi-HHUS memiliki kesesuaian dengan level relatif setara dalam menentukan ada tidaknya lesi dan lokasi lesi, namun sedikit lebih tinggi dalam menilai morfologis lesi dibandingkan dengan kombinasi mamografi- ABUS.

Background: Mammography is the gold standard and well known to be a powerful screening tool in the detection of breast cancer. However its sensitivity is reduced in women with dense breasts. Additionally, women with dense breasts have an increased risk of developing breast cancer while mammography has a lower sensitivity. Handheld ultrasonography (HHUS) is often needed as a adjunction to mammography, can increase sensitivity and specificity for detection of cancer in dense breast breasts. Automated breast ultrasound (ABUS) is a relative new modality with several advantages compared to HHUS including reproducible, low variability, shorter and consistent acquisition time, and a wide transducer size that covers the breast more thoroughly and can characterize lesions whose size exceeds the width of the transducer HHUS better. At present the use of ABUS is not evenly distributed in hospitals in Indonesia, and research on ABUS is still limited, so it is necessary to conduct research on ABUS compared to other modalities more objectively. Objective : This study aims to determine the alternative selection of HHUS and ABUS examination to detect abnormalities in the breast based on mammographic density. Method: Breast examination using mammography, HHUS GE Logic S8 with 7-12 MHz linear transducer, and GE Invenia ABUS with 6-12 MHz linear concave transducer. All HHUS and ABUS examinations are carried out solely by researchers in the Radiology Department of the RSCM, and are confirmed by an ABUS certified breast consultant radiologist to determine the presence, morphology, and location of the lesion. The suitability of ABUS mammography and HHUS mammography results were analyzed using the Mc Nemar test. Result: There were 30 subjects and 48 breast samples were obtained, with an age range of 36-66 years (mean ± SD 51.4 ± 8.5 years). In determining the presence or absence of lesions, examination of mammography- HHUS and mammography-ABUS is in accordance with moderate agreement and Kappa values 0.43 and 0.49 (p 0.002 and p 0.001); in determining the morphology of the lesion is in accordance with moderate agreement and Kappa value 0.51 and 0.43 (p 0,000 and 0,000); and in determining the location of the lesion is in accordance with fair agreement and Kappa values of 0.37 and 0.36 (p 0,000 and 0,000). Conclusion : The mammographic-HHUS combination is compatible with a relatively equal level in determining the presence or absence of the lesion and location of the lesion, but is slightly higher in assessing the morphology of the lesion compared with the mammographic- ABUS combination. "
Depok: Fakultas Kedokteran Universitas Indonesia, 2019
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
I Made Arya Winatha
"Pada tahun 2010 American Venous Forum mengembangkan sebuah sistem skoring Venous Clinical Severity Score (VCSS) untuk menilai tingkat keparahan Insufisiensi Vena Kronik, dimana system ini dikatakan lebih lengkap daripada system CEAP. Tetapi validasi VCSS terhadap uji obyektif masih kurang. Tujuan Penelitian ini adalah untuk menguji VCSS terhadap refluks dan diameter vena tungkai berdasarkan ultrasonografi. Penelitian ini merupakan suatu uji diagnostik potong lintang pada pekerja wanita dengan posisi kerja berdiri sebnyak 114 orang (228 tungkai). Dilakukan penilaian VCSS dan pemeriksaan USG pada semua subjek. Hubungan antara VCSS dengan refluks dan diameter vena tungkai dianalisis menggunakan odd rasio dengan interval kepercayaan 95%. Dari 228 tungkai yang diperiksa didapatkan skor VCSS 0-3 sebanyak 18,4%, skor ≥4sebanyak 81,6%. Refluks didapatkan pada 21,9% tungkai. Terdapat hubungan yang signifikan antara VCSS dengan refluks pada vena tungkai. Sedangkan diameter vena safena magna antara 2,1-12,2mm, vena femoral 7,1-17mm, vena popliteal 3-11,4 dan vena safena parva 1,7-7mm. Ketika VCSS dihubungkan dengan diameter vena, didapatkan hubungan yang signifikan. Sensistivitas VCSS dibandingkan dengan refluks berdasarkan USG didapatkan 78%, spesivitas 98,31%, nilai prediksi positif 92,86% dan nilai prediksi negatif 93,86%. Dari hasil penelitian ini disimpulkan skoring VCSS dapat dipakai sebagi metode untuk menilai insufisiensi vena kronik. Meskipun VCSS dirancang untuk menilai keparahan penyakit vena kronis,  VCSS dapat juga dipaki untuk melakukan skrining karena menujukkan hubungan yang baik dengan refluks dan diameter vena tungkai berdasarkan USG.

In 2010 the American Venous Forum developed a scoring system for the Venous Clinical Severity Score (VCSS) to assess the severity of chronic venous insufficiency, where the system is said to be more complete than the CEAP system. But the VCSS validation of the objective test is still lacking. The aim of this study was to test VCSS for reflux and diameter of leg veins based on ultrasonography. This study is a cross-sectional diagnostic test on female workers with a working position standing at 114 people (228 limbs). VCSS assessment and ultrasound examination were performed on all subjects. The relationship between VCSS and reflux and limb vein diameter was analyzed using odds ratios with a 95% confidence interval. From the 228 limbs examined, the VCSS score of 0-3 was 18.4%, the score ≥4 was 81.6%. Reflux is obtained at 21.9% of the legs. There is a significant relationship between VCSS and reflux in the leg veins. Whereas the diameter of the safena magna vein is between 2.1-12.2mm, 7.1-17mm femoral vein, popliteal vein 3-11.4 and safena parva vein 1.7-7mm. When VCSS is associated with vein diameter, a significant relationship is obtained. The sensitivity of VCSS compared with reflux based on USG was 78%, the specificity was 98.31%, the positive predictive value was 92.86% and the negative predictive value was 93.86%. From the results of this study concluded VCSS scoring can be used as a method to assess chronic venous insufficiency. Although VCSS is designed to assess the severity of chronic venous disease, VCSS can also be cited for screening because it shows a good relationship with reflux and diameter of leg veins based on ultrasound.

"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2018
SP-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Wuwus Ardiatna
"Ultrasound merupakan salah satu modalitas citra yang masih digunakan untuk mendeteksi dini kelainan ginjal. Proses diagnosa abnormalitas pada ginjal pada umumnya masih menggunakan pendekatan morfologi atau istilah radiologi untuk mendeskripsikannya. Tujuan dari penelitian ini adalah melakukan karakterisasi citra medis hasil ultrasound ginjal normal dan abnormal. Statistical Moment Descriptor merupakan teknik yang digunakan untuk mengkarakterisasi berdasarkan distribusi spasial piksel ultrasound B-mode. Teknik yang digunakan adalah dengan menghitung besarnya rerata, standar deviasi, skewness, kurtosis, entropi, median, dan rentang, serta dimensi ginjal pada region of interest ROI dari tiga area, yaitu area ginjal penuh, kortek, dan renal pelvis, dari total 50 data pasien dengan ginjal normal abnormal. Hasil yang diperoleh menunjukkan sebaran nilai piksel area penuh citra ginjal normal untuk parameter rerata 69 12,83, standar deviasi 41,77 5,66, skewness 0,87 0,28, kurtosis 4,12 0,88, entropi 6,02 0,27, nilai piksel median 75 15,77, range 253 3,18, sedangkan untuk citra ginjal abnormal sebaran nilai piksel dengan parameter rerata 103 31,96, standar deviasi 35,76 7,62, skewness 0,62 0,68, kurtosis 5,43 2,02, entropi 5,74 0,50, nilai piksel median 100 34,43, dan range 254 0. Parameter yang sangat signifikan berbeda terhadap nilai rerata dengan menggunakan uji t adalah standar deviasi, median, rentang, rerata, kurtosis, untuk entropi secara statistik berbeda signifikan, sedangkan skewness, secara statistik tidak begitu signifikan berbeda.

Ultrasound is one of the image modality that is still used for detect early kidney abnormalities. Morphological approach or radiology terms are still being used to describe it. The purpose of this research is to characterize normal and abnormal kidney medical ultrasound image. Statistical Moment Descriptor is a techniques that we used to characterize spatial pixels distribution of B Mode by define mean, standard deviation, skewness, kurtosis, entropy, median, range, and dimensions in three region of interest`s, full kidney, cortical, and renal pelvis area, from 50 total patients. The results obtained is that pixel values distribution of full normal kidney area for mean 69 12.83, standard deviation 41.77 5.66, skewness 0.87 0.28, kurtosis 4.12 0, 88, entropy 6,02 0,27, median 75 15,77, and range 253 3,18, for abnormal kidney, mean 103 31,96, standard deviation 35, 76 7.62, skewness 0.62 0.68, kurtosis 5.43 2.02, entropy 5.74 0.50, median 100 34.43, and range 254 0. Standard deviation, median, range, mean and kurtosis differences are considered to be very statistically significant by the t test, entropy is considered as significant, and skewness is considered to be not statistically significant."
Depok: Universitas Indonesia, 2018
T51574
UI - Tesis Membership  Universitas Indonesia Library
cover
Sergie
"Kombinasi metode ozonasi dan kavitasi ultrasonik diketahui dapat digunakan sebagai alternatif desinfeksi bakteri Escherichia coli. Ozon diketahui dapat menyerang membran sel bakteri dan kavitasi ultrasonik meningkatkan perpindahan massa ozon ke sistem. Variabel penelitian yang diamati seperti intensitas gelombang 30 , 60 dan 100, dosis ozon 84 mg/jam, 157 mg/jam dan 231 mg/jam dan kombinasi keduanya diamati kemampuannya dalam mendesinfeki E.coli. Intensitas gelombang 100 dan konsentrasi ozon 231 mg/jam menghasilkan proses desinfeksi yang terbaik pada kondisi masing-masing, sehingga gabungan keduanya dipilih dalam proses kombinasi kedua metode. Proses kombinasi ini menghasilkan pengurangan jumlah koloni bakteri paling cepat dan juga menurunkan konsentrasi bakteri ke jumlah koloni paling kecil dengan persentase pengurangan konsentrasi sebesar 99,99 dalam waktu 15 menit. Selain itu, desinfeksi dengan menggunakan ozon saja dengan konsentrasi 231 mg/jam menghasilkan persentase desinfeksi sebesar 99,04 dan kavitasi ultrasonik dengan intensitas 100 menghasilkan persentase desinfeksi sebesar 68 pada menit ke 15.

Combination of ozone and ultrasonic cavitation can be used as an alternative process for disinfection of Escherichia coli where the residual of this process is considered to be more safety than the previous one e.g. chlorination. Ozone can attack membrane cell of bacteria and ultrasonic cavitation has an advantage in generation of OH radicals which make an enzyme denaturation on bacteria. This research divided by three kinds of disinfection method to find the best applicable one, which are disinfection using ozone only, ultrasonic cavitation only and combination of ozone and ultrasonic cavitation. The best condition for E.coli disinfection resulted by this research is when a combination of 231 mg L of ozone and 100 wave intensity is used. This condition gave a result of 99,99 percentage of E.coli disinfection in 15 minutes. Other condition where 231 mg L of ozone is used, resulting 99,04 of disinfection and 100 wave intensity gives 68 of disinfection for 15 minutes."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67262
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ratna Moniqa
"ABSTRAK
Latar belakang dan tujuan : Artropati hemofilia merupakan salah satu komplikasi yang terjadi pada penyandang hemofilia dengan predileksi pada sendi siku, lutut dan pergelangan kaki. Deteksi dini artropati hemofilia dapat memperbaiki evaluasi dan tatalaksana. Ultrasonografi metode HEAD-US merupakan metode yang dapat digunakan untuk mendeteksi dini kelainan sendi penyandang hemofilia menggunakan sistem skoring yang cepat dan relatif mudah. Evaluasi sendi secara klinis pada artropati hemofilia dilakukan dengan pemeriksaan skor HJHS. Ultrasonografi metode HEAD-US dapat menjadi penunjang evaluasi artropati hemofilia .Metode : Uji korelatif dengan pendekatan potong lintang pada skor ultrasonografi metode HEAD-US dengan skor HJHS. Kedua pemeriksaan dilakukan pada 120 sendi penyandang hemofilia yaitu siku, lutut dan pergelangan kaki. Pemeriksaan HEAD-US dan HJHS dilakukan pada hari yang sama. Hasil : Rerata umur subyek penelitian adalah 9,3 tahun sebaran 5-14 tahun . Pemeriksaan HEAD-US memiliki median 8 dengan sebaran 1-28 dan mayoritas kelainan pada pergelangan kaki. Pemeriksaan HJHS memiliki sebaran skor 0-35 dengan median 3, mayoritas kelainan pada lutut.Kesimpulan : Terdapat korelasi positif kuat antara pemeriksaan ultrasonografi metode HEAD-US dengan pemeriksaan HJHS. p = 0,002, r= 0,65 . Didapatkan formula regresi linear yaitu : skor HJHS = = ndash; 3,74 0,86 x skor HEAD-US. Untuk memperkirakan skor HJHS setelah diketahui skor HEAD-US.

ABSTRACT
Background and objective Hemophilic artropathy is one of complication of hemophilia. The elbows, knees and ankles are the most affected joints. Detection of early blood induced joint changes may improve monitoring of treatment. HEAD US scanning protocol is a quick and simple method that can be used to detect hemophilic arthropathy. Clinically, hemophilic arthropathy was assessed using HJHS. The aim of this study was to explore the value HEAD US scanning protocol on evaluating hemophilic arthropathy. Methods Cross sectional correlation study between HEAD US and HJHS. Both were done on 120 hemophilic elbow, knee and ankle joints . HEAD US and HJHS were done on the same day. Results Mean age was 9,3 years range 5 14 years . Median score of HEAD US was 8 range 1 28 , mostly on ankles. Median score of HJHS was 3 range 0 35 , mostly on knees. . Conclusion There is strong correlation between HEAD US with HJHS. p 0,002, r 0,65 . Linear regression formula was HJHS score ndash 3,74 0,86 x HEAD US score. This formula can be used to predict HJHS score. "
2016
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Ade Rohmana
"ABSTRAK
Latar Belakang: Penilaian diameter trakea praanestesia merupakan hal yang sangat penting dalam memilih ukuran diameter pipa endotrakea tanpa kaf yang sesuai, untuk meminimalisi penggunaan alat bantu jalan napas yang berlebihan dan risiko trauma jalan napas. Rumus yang paling umum digunakan saat ini di RSUPN Cipto Mangunkusumo dalam memprediksi ukuran diameter pipa endotrakea tanpa kaf pada pasien pediatrik adalah rumus Cole [ usia dalam tahun/4 4 mm]. Rumus Cole memiliki kekurangan yaitu tidak memperhitungkan perbedaan perkembangan fisik dan ras pada pasien pediatrik, sehingga kurang menggambarkan diameter trakea secara aktual. Metode baru untuk memprediksi diameter pipa endotrakea adalah dengan menggunakan teknik ultrasonografi. Pengukuran ultrasonografi memiliki kelebihan mampu memprediksi diameter pipa endotrakea tanpa kaf secara aktual, tidak dipengaruhi oleh perkembangan fisik anak dan ras.Metode: Penelitian ini adalah penelitian observasional analitik komparatif untuk membandingkan ketepatan pengukuran ultrasonografi dengan rumus Cole dalam memprediksi ukuran diameter pipa endotrakea tanpa kaf pada pasien pediatrik ras Melayu usia 1-6 tahun di RSUPN Cipto Mangunkusumo. Setelah mendapatkan persetujuan izin etik dari Komite Etik Penelitian FKUI-RSCM, didapatkan sampel sebanyak 60 subjek. Data yang diperoleh dianalisis dengan menggunakan SPSS dan McNemar.Hasil: Didapatkan proporsi ketepatan pengukuran ultrasonografi dalam memprediksi diameter pipa endotrakea tanpa kaf pada pasien pediatrik ras Melayu usia 1-6 tahun di RSUPN Cipto Mangunkusumo sebesar 95 , sedangkan proporsi ketepatan prediksi berdasarkan rumus Cole hanya sebesar 51,7 populasi. Prediksi diameter pipa endotrakea tanpa kaf berdasarkan pengukuran ultrasonografi secara statistik signifikan lebih tepat dibandingkan prediksi diameter pipa endotrakea berdasarkan rumus Cole p
ABSTRACT
Background Preanesthesia measurement of the diameter of the trachea remains important step to select the appropriate tube size. This aims to minimalize the use of exagerate breathing support and airway trauma. In Cipto Mangunkusumo Hospital, Cole formula is commonly used to predict the uncuffed endotracheal tube size in pediatric patients. However, this formula does not measure the difference in race and physicial development in pediatric patients. Recent method to predict the uncuffed endotracheal tube size is by using ultrasound. Ultrasound is able to predict the actual size for the uncuffed endotracheal tube regardless the race and physical development. Method This was a comparative analytic observational study to compare the accuracy of ultrasound measuremnt in comparison with Cole formula to predict the uncuffed endotracheal tube size in pediatric patients among Malay race age 1 6 years old in Cipto Mangunkusumo Hospital. Following the approval from the Ethical Committee, there were 60 samples obtained. Data were analysed by using SPSS and Mc Nemar test. Result The proportion of ultrasound accuracy to predict the size of the uncuffed endotracheal tube among pediatric patients was 95 , while proportion of Cole formula accuracy was only 51.7 . This reslt was statistically significant p"
2016
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Larasati Kusuma Putri
"Latar Belakang: Kanker payudara merupakan keganasan yang dapat bermetastasis ke kelenjar limfe aksila dan/atau organ jauh. Studi-studi sebelumnya menunjukkan terdapat kaitan antara sejumlah morfologi mamogram dan gambar ultrasonografi (USG) payudara dengan adanya metastasis kelenjar limfe. Seringkali pasien dengan kecurigaan kanker payudara diperiksakan di rumah sakit ketika sudah dalam stadium lanjut atau bahkan terdapat metastasis yang seharusnya dapat dideteksi lebih awal. Mamografi dan USG payudara merupakan modalitas radiologis yang mudah untuk dikerjakan untuk diagnosis kanker payudara dan tersedia di banyak rumah sakit. Sampai saat ini, belum ada penelitian mengaitkan secara langsung temuan morfologis mamografi dan USG payudara pada pasien kanker payudara yang mengalami metastasis. Tujuan: Mengetahui perbedaan temuan morfologis mamografi dan USG payudara pada pasien kanker payudara dengan metastasis dengan pasien kanker payudara tanpa metastasis di RSUPN Dr. Cipto Mangunkusumo (RSCM). Metode: Dilakukan pembacaan ulang hasil mamogram dan gambar USG payudara dari 112 pasien yang didapatkan dari sistem Picture Archiving and Communication System (PACS) di Departemen Radiologi RSCM dengan klinis karsinoma payudara berdasarkan patologi anatomi. Data riwayat pasien didapatkan dengan melihat catatan di rekam medis melalui Electronic Health Record (HER) atau Hospital Information System (HIS). Dilakukan analisis pada usia dan karakteristik morfologis lesi meliputi variabel bentuk lesi, ukuran terbesar lesi, jarak tumor ke kutis, adanya kalsifikasi, jenis kalsifikasi, distribusi kalsifikasi, dan adanya distorsi arsitektur pada mamogram, dan bentuk lesi, ukuran terbesar lesi, jarak tumor ke kutis, vaskularisasi lesi, adanya kalsifikasi, dan adanya distorsi arsitektur pada gambar USG payudara menggunakan uji Chi-Square atau Fisher. Dilakukan juga analisis multivariat regresi logsitik pada variabel yang signifikan secara statistik menggunakan metode backward yang disajikan dalam bentuk odds ratio (OR). Hasil: Terdapat perbedaan yang bermakna secara statistik pada variabel usia (p=0,032), ukuran terbesar lesi pada mamogram (p<0,001), jarak tumor ke kutis pada mamogram (p=<0,001), ukuran terbesar lesi pada gambar USG payudara (p<0,001), dan jarak tumor ke kutis pada gambar USG payudara (p=0,001) antara pasien kanker payudara dengan metastasis dengan tanpa metastasis. Pada analisis multivariat gabungan temuan morfologis mamogram dan gambar USG payudara, didapatkan perbedaan bermakna secara statistik pada ukuran terbesar lesi pada mamogram dengan nilai OR 3,73 (p=0,003) dan jarak tumor ke kutis pada mamogram dengan nilai OR 3,34 (p=0,006). Simpulan: Terdapat perbedaan bermakna temuan mamogram dan USG payudara yaitu masing-masing ukuran terbesar lesi>5 cm dan jarak tumor ke kutis ≤0,5 cm dengan adanya metastasis pada kanker payudara. Temuan ukuran terbesar lesi>5 cm dan jarak tumor ke kutis ≤0,5 cm pada mamogram dapat memprediksi kemungkinan terjadinya metastasis pada kanker payudara.

Background: Breast cancer is a malignancy that can metastasize to axillary lymph nodes and distant organs. Previous studies have shown an association between the morphological findings of mammograms and ultrasound images of the breast and the presence of lymph node metastasis. Patients with suspected breast cancer are often examined in the hospital when they are in an advanced stage or even have metastasis that should have been detected earlier. Mammography and breast ultrasound are radiological modalities that are easy to perform to diagnose breast cancer and are available in many hospitals. To date, no studies have directly compared the morphological findings of mammography and breast ultrasound in patients with metastatic breast cancer. Purpose: To identify the differences in the morphological findings of mammography and breast ultrasound in breast cancer patients with metastasis compared to those without metastasis at Dr Cipto Mangunkusumo General Hospital (RSCM). Methods: Mammogram results and breast ultrasound images from 112 patients diagnosed with breast carcinoma based on anatomical pathology were obtained from the Picture Archiving and Communication System (PACS) at the Department of Radiology RSCM. The images were then reviewed. Patient history is obtained from the Electronic Health Record (EHR) or Hospital Information System (HIS). Analyzes were performed on age and morphological characteristics of the lesion, including the shape of the lesion, the largest diameter of the lesion, the distance of the tumor to the skin, the presence of calcification, the type of calcification, the distribution of calcifications, and the presence of architectural distortion on mammograms, and the shape of the lesion, the largest diameter of the lesion, the distance of the tumor to the skin, the vascularity of the lesion, the presence of calcification, and the presence of architectural distortion on breast ultrasound images using Chi-Square or Fisher method. Multivariate logistic regression analysis was also conducted on statistically significant variables using the backward method, which was presented as an odds ratio (OR). Results: There was a statistically significant difference in age (p=0,032), the largest diameter of the lesion on the mammogram (p<0,001), the distance of the tumor to the skin on the mammogram (p<0,001), the largest diameter of the lesion on breast ultrasound (p<0,001), and the distance of the tumor to the skin on breast ultrasound images (p=0,001) between metastatic and non-metastatic breast cancer patients. In the multivariate analysis of the combination of morphological findings of the mammogram and breast ultrasound images, there were statistically significant differences in the largest diameter of the lesion on mammograms with an OR value of 3.73 (p=0,003) and the distance of the tumor to the skin on mammograms with an OR value of 3.34 (p= 0,006). Conclusion: There is a significant difference in mammogram and breast ultrasound findings, such as the largest diameter of the lesion >5 cm and the distance of the tumor to the skin ≤0,5 cm with the presence of metastasis in breast cancer. The findings of the largest diameter of the lesion >5 cm and the distance of the tumor to the skin ≤0,5 cm on the mammogram can predict the probability of metastasis in breast cancer."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2023
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Edinburgh Churchill Livingstone: Elsevier, 2015
R 616.075 7 GRA
Buku Referensi  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>