Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 103 dokumen yang sesuai dengan query
cover
Alberto Paulo Cercado
"Biodiesel was produced using three different alkali catalysts, namely KOH, NaOH and LiOH. The aim of the study was to determine which of these is the most effective as far as Fatty Acid Methyl Ester (FAME) yield is concerned in producing biodiesel from microalgae. Three different transesterification processes were considered; conventional, microwave-assisted and ultrasound-assisted. The study was able to show that NaOH and KOH generated far better FAME values compared to LiOH in all three transesterification processes. The introduction of microwave or ultrasound in the transesterification slightly increased the FAME yield by 5% and cut the reaction time by 50%. The best FAME yield was attained when the optimum process parameters were a methanol to oil ratio of 12:1; a catalyst load of 2% for NaOH and 3% for KOH; a reaction time of 12 minutes; and a microwave output power rate of 600 watts."
Depok: Faculty of Engineering, Universitas Indonesia, 2018
UI-IJTECH 9:4 (2018)
Artikel Jurnal  Universitas Indonesia Library
cover
Cura, Jose Luís del
"This book offers a practical approach to the world of diagnostic ultrasound. It has been structured in a reader-friendly, case-based format that makes it easy and enjoyable to learn the basics of the applications and interpretation of ultrasound. Each case includes illustrations, descriptions of the imaging findings, and technical details and serves to identify the essential imaging features of the pathology under consideration, thus assisting the reader in the diagnosis of similar cases. The book is divided into 17 short chapters that review the most important areas of ultrasound application and also document the latest advances in the use of contrast and interventional ultrasound. The authors treat every topic from a “how to do it” perspective with the aim of imparting their wide experience in use of the technique. "
Berlin : Springer, 2012
e20426088
eBooks  Universitas Indonesia Library
cover
Niken Wulandari
"Ultrasonografi telah dikenal sebagai suatu modalitas penting dalam dunia kedokteran dan telah memasuki bidang dermatologi klinis. Karakteristiknya yang non-invasif membuatnya mudah digunakan dan sepenuhnya aman. Ultrasonografi menghasilkan informasi diagnostik yang penting pada evaluasi tumor kulit. Selain itu juga dapat menerangkan lesi-lesi subkutan dan hubungannya dengan jaringan sekitarnya. Teknik ultrasonografi lainnya dengan menggunakan Doppler berwarna berguna untuk menilai vaskularisasi pada lesi kulit. Dalam tulisan ini, kami ingin menggambarkan aplikasi ultrasonografi pada sejumlah kasus terpilih dari institusi kami. (Med J Indones 2007; 16:113-6).

Ultrasonography has been recognized as an important diagnostic modality in medicine and has entered the area of clinical dermatology. Its non-invasive characteristics have made it easily use and completely safe. It provides important diagnostic information in evaluating skin tumors. It also outlines the subcutaneous lesions and their relation to its adjacent tissue. Another ultrasound technique is color Doppler which is useful to assess vascularization of skin lesion. In this article, we would like to report ultrasound imaging in some selected cases from our institution. (Med J Indones 2007; 16:113-6)."
Medical Journal of Indonesia, 2007
MJIN-16-2-AprJun2007-113
Artikel Jurnal  Universitas Indonesia Library
cover
Michelle Nasseri
"ABSTRAK
Latar belakang: Mamografi merupakan pemeriksaan baku emas dan merupakan modalitas satu-satunya untuk skrining payudara perempuan. Namun efektivitas mamografi menurun terutama pada payudara berdensitas padat. Handheld ultrasonography (HHUS) sering diperlukan sebagai pelengkap mamografi dan dapat meningkatkan sensitivitas dan spesifisitas untuk deteksi kanker payudara berdensitas padat. Automated breast ultrasound (ABUS) merupakan modalitas relatif baru dengan beberapa kelebihan dibandingkan dengan HHUS antara lain reproducible, variabilitas yang rendah, waktu akuisisi lebih singkat dan konsisten, serta ukuran transduser yang lebar sehingga mencakup payudara lebih menyeluruh dan dapat melakukan karakterisasi lesi yang ukurannya melebihi lebar transduser HHUS dengan lebih baik. Saat ini penggunaan ABUS belum merata di rumah sakit di Indonesia, dan penelitian mengenai ABUS masih terbatas, sehingga perlu dilakukan penelitian mengenai ABUS dibandingkan dengan modalitas lain secara lebih obyektif. Tujuan : Penelitian ini bertujuan untuk mengetahui kesesuaian temuan, morfologis, dan lokasi lesi di payudara berdasarkan densitas mamografi dan HHUS dengan densitas mamografi dan ABUS. Metode: Dilakukan pemeriksaan payudara menggunakan mamografi, HHUS GE tipe Logic S8 dengan transduser linear 7-12 MHz, dan ABUS GE Invenia dengan transduser konkaf linear 6-12 MHz. Seluruh pemeriksaan HHUS dan ABUS dilakukan sendiri oleh peneliti di Departemen Radiologi RSCM, dan dikonfirmasi oleh Dokter Spesialis Radiologi konsultan payudara bersertifikasi ABUS untuk menentukan ada atau tidaknya lesi, morfologis, dan lokasi lesi. Kesesuaian hasil pemeriksaan mamografi-ABUS dan mamografi HHUS dianalisis menggunakan uji Mc Nemar. Hasil: Terdapat 30 subyek penelitian dan diperoleh 48 sampel payudara, dengan rentang usia 36-66 tahun (rerata ± SD 51,4 ± 8,5 tahun). Dalam menentukan ada tidaknya lesi, pemeriksaan mamografi-HHUS dan mamografi-ABUS memiliki kesesuaian dengan level sedang (moderate agreement), nilai Kappa 0,43 dan 0,49 (p 0,002 dan p 0,001); dalam menentukan morfologis lesi memiliki kesesuaian dengan level sedang (moderate agreement) dengan nilai Kappa 0,51 dan 0,43 (p 0,000 dan 0,000); serta dalam menentukan lokasi lesi memiliki kesesuaian dengan level fair agreement dengan nilai Kappa 0,37 dan 0,36 (p 0,000 dan 0,000). Simpulan: Kombinasi mamografi-HHUS memiliki kesesuaian dengan level relatif setara dalam menentukan ada tidaknya lesi dan lokasi lesi, namun sedikit lebih tinggi dalam menilai morfologis lesi dibandingkan dengan kombinasi mamografi-ABUS.

ABSTRACT
Background: Mammography is the gold standard and well known to be a powerful screening tool in the detection of breast cancer. However its sensitivity is reduced in women with dense breasts. Additionally, women with dense breasts have an increased risk of developing breast cancer while mammography has a lower sensitivity.
Handheld ultrasonography (HHUS) is often needed as a adjunction to mammography, can increase sensitivity and specificity for detection of cancer in dense breast breasts. Automated breast ultrasound (ABUS) is a relative new modality with several advantages compared to HHUS including reproducible, low variability, shorter and consistent acquisition time, and a wide transducer size that covers the breast more thoroughly and can characterize lesions whose size exceeds the width of the transducer HHUS better. At present the use of ABUS is not evenly distributed in hospitals in Indonesia, and research on ABUS is still limited, so it is necessary to conduct research on ABUS compared to other modalities more objectively. Objective : This study aims to determine the alternative selection of HHUS and ABUS examination to detect abnormalities in the breast based on mammographic density. Method: Breast examination using mammography, HHUS GE Logic S8 with 7-12 MHz linear transducer, and GE Invenia ABUS with 6-12 MHz linear concave transducer. All HHUS and ABUS examinations are carried out solely by researchers in the Radiology Department of the RSCM, and are confirmed by an ABUS certified breast consultant radiologist to determine the presence, morphology, and location of the lesion. The suitability of ABUS mammography and HHUS mammography results were analyzed using the Mc Nemar test. Result: There were 30 subjects and 48 breast samples were obtained, with an age range of 36-66 years (mean ± SD 51.4 ± 8.5 years). In determining the presence or absence of lesions, examination of mammography-HHUS and mammography-ABUS is in accordance with moderate agreement and Kappa values 0.43 and 0.49 (p 0.002 and p 0.001); in determining the morphology of the lesion is in accordance with moderate agreement and Kappa value 0.51 and 0.43 (p 0,000 and 0,000); and in determining the location of the lesion is in accordance with fair agreement and Kappa values ​​of 0.37 and 0.36 (p 0,000 and 0,000). Conclusion : The mammographic-HHUS combination is compatible with a relatively equal level in determining the presence or absence of the lesion and location of the lesion, but is slightly higher in assessing the morphology of the lesion compared with the mammographic-ABUS combination."
2019
SP-PDF
UI - Tugas Akhir  Universitas Indonesia Library
cover
Michelle Nasseri
"Mamografi merupakan pemeriksaan baku emas dan merupakan modalitas satu-satunya untuk skrining payudara perempuan. Namun efektivitas mamografi menurun terutama pada payudara berdensitas padat. Handheld ultrasonography (HHUS) sering diperlukan sebagai pelengkap mamografi dan dapat meningkatkan sensitivitas dan spesifisitas untuk deteksi kanker payudara berdensitas padat. Automated breast ultrasound (ABUS) merupakan modalitas relatif baru dengan beberapa kelebihan dibandingkan dengan HHUS antara lain reproducible, variabilitas yang rendah, waktu akuisisi lebih singkat dan konsisten, serta ukuran transduser yang lebar sehingga mencakup payudara lebih menyeluruh dan dapat melakukan karakterisasi lesi yang ukurannya melebihi lebar transduser HHUS dengan lebih baik. Saat ini penggunaan ABUS belum merata di rumah sakit di Indonesia, dan penelitian mengenai ABUS masih terbatas, sehingga perlu dilakukan penelitian mengenai ABUS dibandingkan dengan modalitas lain secara lebih obyektif. Tujuan : Penelitian ini bertujuan untuk mengetahui kesesuaian temuan, morfologis, dan lokasi lesi di payudara berdasarkan densitas mamografi dan HHUS dengan densitas mamografi dan ABUS. Metode: Dilakukan pemeriksaan payudara menggunakan mamografi, HHUS GE tipe Logic S8 dengan transduser linear 7-12 MHz, dan ABUS GE Invenia dengan transduser konkaf linear 6-12 MHz. Seluruh pemeriksaan HHUS dan ABUS dilakukan sendiri oleh peneliti di Departemen Radiologi RSCM, dan dikonfirmasi oleh Dokter Spesialis Radiologi konsultan payudara bersertifikasi ABUS untuk menentukan ada atau tidaknya lesi, morfologis, dan lokasi lesi. Kesesuaian hasil pemeriksaan mamografi-ABUS dan mamografi HHUS dianalisis menggunakan uji Mc Nemar. Hasil: Terdapat 30 subyek penelitian dan diperoleh 48 sampel payudara, dengan rentang usia 36-66 tahun (rerata ± SD 51,4 ± 8,5 tahun). Dalam menentukan ada tidaknya lesi, pemeriksaan mamografi- HHUS dan mamografi-ABUS memiliki kesesuaian dengan level sedang (moderate agreement), nilai Kappa 0,43 dan 0,49 (p 0,002 dan p 0,001); dalam menentukan morfologis lesi memiliki kesesuaian dengan level sedang (moderate agreement) dengan nilai Kappa 0,51 dan 0,43 (p 0,000 dan 0,000); serta dalam menentukan lokasi lesi memiliki kesesuaian dengan level fair agreement dengan nilai Kappa 0,37 dan 0,36 (p 0,000 dan 0,000). Simpulan: Kombinasi mamografi-HHUS memiliki kesesuaian dengan level relatif setara dalam menentukan ada tidaknya lesi dan lokasi lesi, namun sedikit lebih tinggi dalam menilai morfologis lesi dibandingkan dengan kombinasi mamografi- ABUS.

Background: Mammography is the gold standard and well known to be a powerful screening tool in the detection of breast cancer. However its sensitivity is reduced in women with dense breasts. Additionally, women with dense breasts have an increased risk of developing breast cancer while mammography has a lower sensitivity. Handheld ultrasonography (HHUS) is often needed as a adjunction to mammography, can increase sensitivity and specificity for detection of cancer in dense breast breasts. Automated breast ultrasound (ABUS) is a relative new modality with several advantages compared to HHUS including reproducible, low variability, shorter and consistent acquisition time, and a wide transducer size that covers the breast more thoroughly and can characterize lesions whose size exceeds the width of the transducer HHUS better. At present the use of ABUS is not evenly distributed in hospitals in Indonesia, and research on ABUS is still limited, so it is necessary to conduct research on ABUS compared to other modalities more objectively. Objective : This study aims to determine the alternative selection of HHUS and ABUS examination to detect abnormalities in the breast based on mammographic density. Method: Breast examination using mammography, HHUS GE Logic S8 with 7-12 MHz linear transducer, and GE Invenia ABUS with 6-12 MHz linear concave transducer. All HHUS and ABUS examinations are carried out solely by researchers in the Radiology Department of the RSCM, and are confirmed by an ABUS certified breast consultant radiologist to determine the presence, morphology, and location of the lesion. The suitability of ABUS mammography and HHUS mammography results were analyzed using the Mc Nemar test. Result: There were 30 subjects and 48 breast samples were obtained, with an age range of 36-66 years (mean ± SD 51.4 ± 8.5 years). In determining the presence or absence of lesions, examination of mammography- HHUS and mammography-ABUS is in accordance with moderate agreement and Kappa values 0.43 and 0.49 (p 0.002 and p 0.001); in determining the morphology of the lesion is in accordance with moderate agreement and Kappa value 0.51 and 0.43 (p 0,000 and 0,000); and in determining the location of the lesion is in accordance with fair agreement and Kappa values of 0.37 and 0.36 (p 0,000 and 0,000). Conclusion : The mammographic-HHUS combination is compatible with a relatively equal level in determining the presence or absence of the lesion and location of the lesion, but is slightly higher in assessing the morphology of the lesion compared with the mammographic- ABUS combination. "
Depok: Fakultas Kedokteran Universitas Indonesia, 2019
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Rondonuwu, Cherry Alisa Lidya
"ABSTRAK
Kejang pada neonatus merupakan gejala yang paling sering ditemukan dari gangguan neurologis pada periode neonatus. Kejang pada neonatus dapat terjadi sebagai akibat dari etiologi yang beragam dan ini sering menandakan adanya kerusakan atau malfungsi dari sistem saraf pusat yang belum berkembang sempurna. Penelitian bertujuan untuk mengetahui profil dan luaran kejang pada neonatus serta faktor-faktor yang memengaruhinya. Studi retrospektif dari data sekunder rekam medis Unit Perinatologi RS Cipto Mangunkusumo (RSCM) pada periode Januari 2015 sampai Juni 2019. Semua neonatus di RSCM dengan usia kronologis ≤ 28 hari pada neonatus aterm atau ≤ 44 minggu sejak konsepsi pada neonatus prematur, dengan riwayat kejang atau mengalami kejang minimal satu kali selama perawatan, diikutkan dalam penelitian ini. Subjek dieksklusi bila terdapat kecurigaan kelainan bawaan dan rekam medis tidak lengkap. Pencatatan terhadap subjek meliputi riwayat antenatal, gejala klinis, hasil EEG dan neuroimaging, serta luaran. Studi dilakukan terhadap 108 subjek dan didapatkan jenis kelamin lelaki sebesar 59,3%, usia gestasi aterm sebesar 55,6%, serta berat lahir normal sebesar 52,8%. Kematian terjadi pada 38 (35,2%) subjek. Insidens kejang pada neonatus di Unit Perinatologi RSCM sebesar 3,3%. Karakteristik neonatus yang mengalami kejang adalah jenis kelamin lelaki, aterm, persalinan dengan bedah kaisar, riwayat resusitasi aktif, dan respons dengan pemberian obat anti kejang tunggal. Luaran meninggal pada penelitian ini sebesar 35,2% dengan faktor-faktor yang memengaruhinya yaitu usia gestasi, berat lahir, frekuensi kejang, dan penyakit penyerta sepsis.

ABSTRACT
Neonatal seizures are the most common manifestation of neurological disorders in the newborn period. Neonatal seizures may arise as a result of diverse etiologies and these events frequently signify serious damage or malfunction of the immature developing central nervous system. The study is aimed to determine neonatal seizures profile and factors that influence its outcome. This was a retrospective cohort study from secondary medical record data at Neonatology Unit of Cipto Mangunkusumo General Hospital (CMGH) between January 2015-Juni 2019. All neonates in CMGH with a chronological age of ≤ 28 days in a term infant or ≤ 44 weeks from conception in a preterm infant, with seizure or history of seizure were included in the study. Subjects were excluded if they were suspected of having congenital disorders or incomplete medical records. Data collected from the subjects include antenatal history, clinical symptoms, EEG findings, neuroimaging results, and outcome at discharge. A total of 108 subjects were included in the study and among neonates with seizures, 59,3% were male, 55,6% were born term, and 52,8 % had normal birth weight. Death occurred in 38 cases (35,2%). Incidens of neonatal seizure in Neonatology Unit of CMGH was 3,3%. Neonates who developed seizure characterized by male gender, term birth, delivered by section cesarean, history of active resuscitation, and respons to single antiepileptic drug. The mortality rate in this study was 35,2% with gestational age, birth weight, frequency of seizure, and sepsis being the factors that influence the outcome."
Depok: Fakultas Kedokteran Universitas Indonesia, 2019
SP-PDF
UI - Tugas Akhir  Universitas Indonesia Library
cover
Ratna Moniqa
"ABSTRAK
Latar belakang dan tujuan : Artropati hemofilia merupakan salah satu komplikasi yang terjadi pada penyandang hemofilia dengan predileksi pada sendi siku, lutut dan pergelangan kaki. Deteksi dini artropati hemofilia dapat memperbaiki evaluasi dan tatalaksana. Ultrasonografi metode HEAD-US merupakan metode yang dapat digunakan untuk mendeteksi dini kelainan sendi penyandang hemofilia menggunakan sistem skoring yang cepat dan relatif mudah. Evaluasi sendi secara klinis pada artropati hemofilia dilakukan dengan pemeriksaan skor HJHS. Ultrasonografi metode HEAD-US dapat menjadi penunjang evaluasi artropati hemofilia .Metode : Uji korelatif dengan pendekatan potong lintang pada skor ultrasonografi metode HEAD-US dengan skor HJHS. Kedua pemeriksaan dilakukan pada 120 sendi penyandang hemofilia yaitu siku, lutut dan pergelangan kaki. Pemeriksaan HEAD-US dan HJHS dilakukan pada hari yang sama. Hasil : Rerata umur subyek penelitian adalah 9,3 tahun sebaran 5-14 tahun . Pemeriksaan HEAD-US memiliki median 8 dengan sebaran 1-28 dan mayoritas kelainan pada pergelangan kaki. Pemeriksaan HJHS memiliki sebaran skor 0-35 dengan median 3, mayoritas kelainan pada lutut.Kesimpulan : Terdapat korelasi positif kuat antara pemeriksaan ultrasonografi metode HEAD-US dengan pemeriksaan HJHS. p = 0,002, r= 0,65 . Didapatkan formula regresi linear yaitu : skor HJHS = = ndash; 3,74 0,86 x skor HEAD-US. Untuk memperkirakan skor HJHS setelah diketahui skor HEAD-US.

ABSTRACT
Background and objective Hemophilic artropathy is one of complication of hemophilia. The elbows, knees and ankles are the most affected joints. Detection of early blood induced joint changes may improve monitoring of treatment. HEAD US scanning protocol is a quick and simple method that can be used to detect hemophilic arthropathy. Clinically, hemophilic arthropathy was assessed using HJHS. The aim of this study was to explore the value HEAD US scanning protocol on evaluating hemophilic arthropathy. Methods Cross sectional correlation study between HEAD US and HJHS. Both were done on 120 hemophilic elbow, knee and ankle joints . HEAD US and HJHS were done on the same day. Results Mean age was 9,3 years range 5 14 years . Median score of HEAD US was 8 range 1 28 , mostly on ankles. Median score of HJHS was 3 range 0 35 , mostly on knees. . Conclusion There is strong correlation between HEAD US with HJHS. p 0,002, r 0,65 . Linear regression formula was HJHS score ndash 3,74 0,86 x HEAD US score. This formula can be used to predict HJHS score. "
2016
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Ade Rohmana
"ABSTRAK
Latar Belakang: Penilaian diameter trakea praanestesia merupakan hal yang sangat penting dalam memilih ukuran diameter pipa endotrakea tanpa kaf yang sesuai, untuk meminimalisi penggunaan alat bantu jalan napas yang berlebihan dan risiko trauma jalan napas. Rumus yang paling umum digunakan saat ini di RSUPN Cipto Mangunkusumo dalam memprediksi ukuran diameter pipa endotrakea tanpa kaf pada pasien pediatrik adalah rumus Cole [ usia dalam tahun/4 4 mm]. Rumus Cole memiliki kekurangan yaitu tidak memperhitungkan perbedaan perkembangan fisik dan ras pada pasien pediatrik, sehingga kurang menggambarkan diameter trakea secara aktual. Metode baru untuk memprediksi diameter pipa endotrakea adalah dengan menggunakan teknik ultrasonografi. Pengukuran ultrasonografi memiliki kelebihan mampu memprediksi diameter pipa endotrakea tanpa kaf secara aktual, tidak dipengaruhi oleh perkembangan fisik anak dan ras.Metode: Penelitian ini adalah penelitian observasional analitik komparatif untuk membandingkan ketepatan pengukuran ultrasonografi dengan rumus Cole dalam memprediksi ukuran diameter pipa endotrakea tanpa kaf pada pasien pediatrik ras Melayu usia 1-6 tahun di RSUPN Cipto Mangunkusumo. Setelah mendapatkan persetujuan izin etik dari Komite Etik Penelitian FKUI-RSCM, didapatkan sampel sebanyak 60 subjek. Data yang diperoleh dianalisis dengan menggunakan SPSS dan McNemar.Hasil: Didapatkan proporsi ketepatan pengukuran ultrasonografi dalam memprediksi diameter pipa endotrakea tanpa kaf pada pasien pediatrik ras Melayu usia 1-6 tahun di RSUPN Cipto Mangunkusumo sebesar 95 , sedangkan proporsi ketepatan prediksi berdasarkan rumus Cole hanya sebesar 51,7 populasi. Prediksi diameter pipa endotrakea tanpa kaf berdasarkan pengukuran ultrasonografi secara statistik signifikan lebih tepat dibandingkan prediksi diameter pipa endotrakea berdasarkan rumus Cole p
ABSTRACT
Background Preanesthesia measurement of the diameter of the trachea remains important step to select the appropriate tube size. This aims to minimalize the use of exagerate breathing support and airway trauma. In Cipto Mangunkusumo Hospital, Cole formula is commonly used to predict the uncuffed endotracheal tube size in pediatric patients. However, this formula does not measure the difference in race and physicial development in pediatric patients. Recent method to predict the uncuffed endotracheal tube size is by using ultrasound. Ultrasound is able to predict the actual size for the uncuffed endotracheal tube regardless the race and physical development. Method This was a comparative analytic observational study to compare the accuracy of ultrasound measuremnt in comparison with Cole formula to predict the uncuffed endotracheal tube size in pediatric patients among Malay race age 1 6 years old in Cipto Mangunkusumo Hospital. Following the approval from the Ethical Committee, there were 60 samples obtained. Data were analysed by using SPSS and Mc Nemar test. Result The proportion of ultrasound accuracy to predict the size of the uncuffed endotracheal tube among pediatric patients was 95 , while proportion of Cole formula accuracy was only 51.7 . This reslt was statistically significant p"
2016
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Sergie
"Kombinasi metode ozonasi dan kavitasi ultrasonik diketahui dapat digunakan sebagai alternatif desinfeksi bakteri Escherichia coli. Ozon diketahui dapat menyerang membran sel bakteri dan kavitasi ultrasonik meningkatkan perpindahan massa ozon ke sistem. Variabel penelitian yang diamati seperti intensitas gelombang 30 , 60 dan 100, dosis ozon 84 mg/jam, 157 mg/jam dan 231 mg/jam dan kombinasi keduanya diamati kemampuannya dalam mendesinfeki E.coli. Intensitas gelombang 100 dan konsentrasi ozon 231 mg/jam menghasilkan proses desinfeksi yang terbaik pada kondisi masing-masing, sehingga gabungan keduanya dipilih dalam proses kombinasi kedua metode. Proses kombinasi ini menghasilkan pengurangan jumlah koloni bakteri paling cepat dan juga menurunkan konsentrasi bakteri ke jumlah koloni paling kecil dengan persentase pengurangan konsentrasi sebesar 99,99 dalam waktu 15 menit. Selain itu, desinfeksi dengan menggunakan ozon saja dengan konsentrasi 231 mg/jam menghasilkan persentase desinfeksi sebesar 99,04 dan kavitasi ultrasonik dengan intensitas 100 menghasilkan persentase desinfeksi sebesar 68 pada menit ke 15.

Combination of ozone and ultrasonic cavitation can be used as an alternative process for disinfection of Escherichia coli where the residual of this process is considered to be more safety than the previous one e.g. chlorination. Ozone can attack membrane cell of bacteria and ultrasonic cavitation has an advantage in generation of OH radicals which make an enzyme denaturation on bacteria. This research divided by three kinds of disinfection method to find the best applicable one, which are disinfection using ozone only, ultrasonic cavitation only and combination of ozone and ultrasonic cavitation. The best condition for E.coli disinfection resulted by this research is when a combination of 231 mg L of ozone and 100 wave intensity is used. This condition gave a result of 99,99 percentage of E.coli disinfection in 15 minutes. Other condition where 231 mg L of ozone is used, resulting 99,04 of disinfection and 100 wave intensity gives 68 of disinfection for 15 minutes."
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67262
UI - Skripsi Membership  Universitas Indonesia Library
cover
Edinburgh Churchill Livingstone: Elsevier, 2015
R 616.075 7 GRA
Buku Referensi  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>