"Penelitian ini bertujuan untuk merancang sistem distribusi ice slurry pada sistem pendingin distrik pelabuhan menggunakan campuran water-glycol. Penelitian ini secara khusus mengevaluasi pengaruh daya pompa dan jenis aditif terhadap penurunan tekanan (pressure drop) serta merancang sistem distribusi yang efisien. Berdasarkan data eksperimental dan pertimbangan desain, beberapa kesimpulan utama dapat diambil. Dalam proses pemilihan aditif, dua jenis aditif yaitu etanol 20% dan etilen glikol 20% dibandingkan menggunakan daya pompa 60 W dengan berbagai variasi ukuran pipa. Hasil menunjukkan bahwa semakin besar ukuran pipa menghasilkan nilai pressure drop yang lebih kecil, sesuai dengan teori yang dijelaskan. Namun, etilen glikol 20% menunjukkan nilai pressure drop yang lebih rendah dibandingkan dengan etanol 20%, berkaitan dengan karakteristik mesin generator yang digunakan. Oleh karena itu, aditif etilen glikol dipilih untuk studi lebih lanjut mengenai karakteristik aliran ice slurry. Pada variasi daya pompa antara 20W hingga 60W, flow rate aliran ice slurry mempengaruhi besarnya pressure drop. Semakin besar flow rate, semakin besar nilai pressure drop. Hal ini menunjukkan bahwa semakin tinggi pressure drop, semakin besar daya pompa yang diperlukan untuk mengalirkan ice slurry dengan aditif etilen glikol 20% dan fraksi es di bawah 28%. Berdasarkan karakteristik ini, desain untuk skala yang lebih besar dilakukan menggunakan metode ekstrapolasi untuk menentukan kebutuhan daya pompa yang sesuai. Hasil penelitian ini memberikan panduan praktis dalam merancang sistem distribusi ice slurry yang efisien untuk aplikasi pendingin distrik pelabuhan, dengan fokus pada optimasi jenis aditif dan daya pompa untuk mengurangi pressure drop dan meningkatkan efisiensi sistem.

This study aims to design an ice slurry distribution system in the cooling system of the port district using a water-glycol mixture. This study specifically evaluates the influence of pump power and type of additive on pressure drop and designs an efficient distribution system. Based on experimental data and design considerations, several key conclusions can be drawn. In the additive selection process, two types of additives, namely 20% ethanol and 20% ethylene glycol, are compared using a pump power of 60 W with various variations in pipe size. The results show that the larger the size of the pipe results in a smaller pressure drop value, according to the theory described. However, 20% ethylene glycol shows a lower pressure drop value compared to 20% ethanol, related to the characteristics of the generator engine used. Therefore, the ethylene glycol additive was chosen for further study regarding the flow characteristics of ice slurry. At pump power variations between 20W to 60W, the flow rate of the ice slurry affects the amount of pressure drop. The greater the flow rate, the greater the pressure drop value. This shows that the higher the pressure drop, the greater the pump power required to drain the ice slurry with an ethylene glycol additive of 20% and an ice fraction below 28%. Based on these characteristics, the design for a larger scale is carried out using the extrapolation method to determine the appropriate pump power requirements. The results of this study provide practical guidance in designing an efficient ice slurry distribution system for port district cooling applications, focusing on optimizing additive types and pump power to reduce pressure drop and improve system efficiency."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Pangaribuan, Christian Natanael Halomoan
"Teknologi pendinginan menggunakan ice slurry sebagai media pendingin memiliki berbagai kegunaan sebagai sistem pendinginan yang ramah lingkungan. Pertumbuhan populasi sekitar 1,4% dan didorong oleh permintaan sektor industri. Protokol Montreal 1987 yang menghentikan produksi zat yang dapat merusak lapisan ozon termasuk zat CFC (Chlorofluorocarbons) dan HFC (Hydrofluorocarbons). Penelitian ini bertujuan untuk mengetahui pengaruh variasi rasio glikol dan kecepatan RPM motor terhadap mass fraction ice slurry. Penelitian ini juga bertujuan untuk mengetahui kombinasi rasio water glycol dan kecepatan RPM motor optimum untuk menghasilkan ice slurry yang digunakan sebagai media pendingin dan menentukan jumlah ice slurry yang dibutuhkan untuk mendinginkan distrik pelabuhan menggunakan jaringan perpipaan. Sebuah pelabuhan yang ada, berlokasi di Kalimantan Barat, Indonesia, berfungsi sebagai studi kasus. Penelitian ini menggunakan ice slurry generator dengan metode mechanical scraper dengan ethylene glycol. Hasil penelitian ini menunjukan semakin rendah kecepatan RPM motor, semakin besar mass fraction yang dihasilkan dan semakin besar rasio water glycol, semakin kecil mass fraction ice slurry yang dihasilkan. Kombinasi optimum untuk pendinginan distrik pelabuhan menggunakan jaringan perpipaan adalah pada rasio water glycol 20% dengan kecepatan motor 45 RPM dengan mass fraction sebesar 28,311%. Untuk mendinginkan pelabuhan dengan total luas gedung 3 hektar dibutuhkan 1,009 ton ice slurry.

Cooling technology using ice slurry as a cooling medium has various uses as an environmentally friendly cooling system. The population growth of around 1,4% and is driven by demand from the industrial sector. The 1987 Montreal Protocol stopped the production of substances that could damage the ozone, including CFCs (Chlorofluorocarbons) and HFCs (Hydrofluorocarbons). This research aims to determine the effect of variations in the glycol ratio and motor (scraper) speed to produce ice slurry which is used as a cooling medium and determine the amount of ice slurry needed to the port district using a piping network. An existing port, in West Kalimantan, Indonesia, serves as a case study. This reseach uses an ice slurry generator with mechanical scraper method using ethylene glycol. This research shows that the lower the motor (scraper) speed, the greater mass fraction produced, and the greater water glycol ratio, the smaller mass fraction of ice slurry produced. The optimal combination to cooling the port district using a pipe network is a water glycol ratio of 20% with motor (scraper) speed of 45 RPM with a mass fraction of 28,311%. To cool a port with a total building area of 3 hectares, 1,009 tons are needed."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Agung Bagus Verdinan
"Media pendingin menggunakan ice slurry merupakan media yang paling efisien untuk menjaga kualitas ikan pasca tangkap nelayan. Penelitian dan pengembangan mengenai ice slurry generator perlu terus dilakukan. Salah satu pengembangan yang dapat dilakukan adalah dengan penambahan komponen evaporator. Penelitian berbasis eksperimen ini bertujuan untuk menganalisis pengaruh variasi debit pompa dan lama pengadukan terhadap karakteristik produksi ice slurry generator dengan pre-cooler evaporator. Karakteristik produksi tersebut antara lain adalah waktu pendinginan pada evaporator pre-cooler, konsentrasi es, fraksi massa, dan kapasitas produksi generator. Variasi debit pompa yang diambil adalah 7,93 Lpm, 9,6 Lpm, 11,27 Lpm, 12,93 Lpm, 14,6 Lpm, dan 16,27 Lpm. Untuk variasi lama pengadukan yang diambil adalah 20 menit, 30 menit, 40 menit, 45 menit, 50 menit, dan 60 menit. Berdasarkan eksperimen yang dilakukan didapati laju penurunan temperatur paling cepat adalah sebesar minus 0,00412ºC/detik dengan rerata laju perpindahan kalor sebesar -784,817 Joule per detik pada nilai debit pompa 11,27 Lpm. Konsentrasi es tertinggi didapat pada waktu pengadukan 60 menit. Semakin lama pengadukan, fraksi massa akan semakin meningkat. Didapati kapasitas produksi generator sebesar 257,14286 Liter per 24 jam.

Cooling medium using ice slurry is the most efficient medium to maintain fish quality after fishing. Research and development on ice slurry generators need to continue. One of the developments that can be done is by adding an evaporator component. This experimental-based research aims to analyze the effect of variations in pump discharge and stirring time on the production characteristics of an ice slurry generator with a pre-cooler evaporator. The production characteristics include cooling time in the pre-cooler evaporator, ice concentration, mass fraction, and generator production capacity. The pump discharge variations taken were 7.93 Lpm, 9.6 Lpm, 11.27 Lpm, 12.93 Lpm, 14.6 Lpm, and 16.27 Lpm. For variations of stirring time taken are 20 minutes, 30 minutes, 40 minutes, 45 minutes, 50 minutes, and 60 minutes. Based on the experiments conducted, it was found that the fastest temperature drop rate was minus 0.00412ºC/second with an average heat transfer rate of -784,817 Joules per second at a pump discharge value of 11.27 Lpm. The highest ice concentration was obtained at a stirring time of 60 minutes. The longer the stirring, the mass fraction will increase. The generator production capacity was found to be 257,14286 Liters per 24 hours."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Bambang Sutrisna
"Sebagai negara kepulauan terbesar, peranan transportasi laut di indonesia menjadi sangat penting dan vital. Dalam transportasi laut terdapat dua hal pokok yang saling bergantung satu sama lain, yaitu antara sarana (kapal laut) dan prasarana (fasilitas pelabuhan).
Pelabuhan sebagai salah satu hal pokok dalam penyelenggaraan transportasi laut memiliki peran yang sangat penting dan strategis dalam menunjang perekonomian nasional dan daerah, karena merupakan tempat peralihan antarmoda transportasi darat dan laut.
Pelabuhan memiliki fungsi untuk menunjang kelancaran, keamanan dan ketertiban arus lalu lintas kapal, penumpang, barang dan keselamatan berlayar. salah satu pelabuhan yang tergolong cukup besar di indonesia adalah pelabuhan Tanjung Priok. Sebagai pelabuhan yang terbuka untuk perdagangan luar negeri, pelabuhan ini dituntut untuk memberikan pelayanan, utamanya pelayanan bongkar muat kapal yang dapat memuaskan pemilik kapal atau perusahaan pelayaran, beberapa indikdtor pelayanan yang baik adalah kapal tidak harus menunggu berhari-hari untuk mendapatkan pelayanan bongkar muat dan waktu pelayanan bongkar muat yang relatif lehih cepat, terutama di dermaga konvensionl.
Metode penelitian yang digunakan adalah metode penelitian deskriptif jenis studi kasus, sedangkan metode yang digunakan untuk menganalisis data teritung berapa lama kapal harus menunggu dari pelabuhan Tanjung Priok sebelum mendapatkan pelayanan bongkar muat, berapa jumlah antrian kapal di pelabuhan tanjung priok dan berapa lama kapal berada dalam sistem antrian adalah metode analisis sistem antrian. Dengan metode ini pula dapat ditentukan langkah-langkah untuk meningkatkan pelayanan terhadap pengguna jasa.
Hasil analisis data menunjukkan bahwa pelayanan bongkar muat di dermaga konvensional pelabuhan Tanjung Priok dapat dikatakan belum optimal, yaitu dengan rata-rata kedatangan (a.) kapal adalah satu kapal per dua hari dan rata-rata waktu pelayanan nol koma enam ratus tujuh puluh sembilan kapal perhari. dengan kondisi tersebut, kapal harus antri rata-rata selarna dua hari lebih untuk mendapatkan pelayanan.
Untuk itu, pelayanan bongkar muat di dermaga konvensional di pelabuhan Tanjung Priok perlu ditingkatkan sehingga kapal tidak harus menunggu lama untuk mendapatkan pelayanan. hal ini terkait dengan biaya yang harus dikeluarkan dari pemilik kapal atau perusahaan pelayaran yang mengoperasikan kapal tersebut. semakin lama kapal menunggu maka biaya yang dikeiuarkan semakin besar. biaya tersebut meliputi biaya anak buah kapal (abk), perbekalan, biaya anchorage, biaya tambat dan lain-lain."
Depok: Fakultas Ilmu Sosial dan Ilmu Politik Universitas Indonesia, 2004
T14036
UI - Tesis Membership  Universitas Indonesia Library
cover
Ismail
"[ABSTRAK
Penelitian ini mengkaji aspek hukum dari kepelabuhanan berupa Terminal Khusus Tersus dan Terminal Untuk Kepentingan Sendiri TUKS oleh Kementerian Perhubungan Republik Indonesia serta mengkaji permasalahan permasalahan terkait dengan perizinan Tersus dan TUKS di Kotamadya Samarinda Provinsi Kalimantan Timur Penelitian ini dilakukan karena adanya permasalahan adanya ketidaksesuain antara Undang Undang No 17 Tahun 2008 tentang Pelayaran Peraturan Pemerintah No 61 Tahun 2009 tentang Kepelabuhanan dengan ketentuan dalam Pasal 46 dan Pasal 47 Permenhub No PM 51 Tahun 2011 tentang Terminal Khusus dan Terminal Untuk Kepentingan Sendiri Selain itu terdapat perbedaan penafsiran mengenai batas batas Daerah Lingkungan Kerja DLKr dan Daerah Lingkungan Kepentingan Pelabuhan DLKp dari Pelabuhan Samarinda oleh Kantor Syahbandar dan Otoritas Pelabuhan KSOP Samarinda dengan Direktorat Jendral Perhubungan Laut Kementrian Perhubungan Ditjen Hubla serta belum adanya penyesuaian terhadap DLKr dan DLKp Pelabuhan Samarinda sesuai dengan amanat ketentuan dalam Pasal 351 UU No 17 Tahun 2008 Penelitian ini dilakukan di kota Samarinda Provinsi Kalimantar Timur karena Pelabuhan Samarinda merupakan jenis pelabuhan laut yang berada di Sungai Mahakam yang memiliki peranan yang sangat penting terhadap kegiatan perekonomian.

ABSTRACT
This study examines the legal aspects of a port in the form of Special Terminal Tersus and Port for Own Interest TUKS by the Ministry of Transport of the Republic of Indonesia as well as examine issues related to licensing Tersus and TUKS in Samarinda East Kalimantan Province This study was conducted because of problem of the existence of the non conformance between Law No 17 Year 2008 Regarding on Shipping Government Regulation No 61 Year 2009 on Port with the provisions of Article 46 and Article 47 Regulation of Ministry of Transportation No PM 51 of 2011 on Special Terminal and Terminal for Own Interest In addition there are differences in interpretation of the limits of the Regional Working Environment DLKr and the Regional Environmental Interests Ports DLKp from the Port of Samarinda the harbor master 39 s Office and Port Authority KSOP Samarinda the Directorate General of Sea Transportation of Ministry of Transportation DGST and there is no adjustment to DLKr and DLKp Port Samarinda in accordance with the provisions of Article 351 of Law No 17 2008 The research was conducted in the city of Samarinda province of East Kalimantan because the Port of Samarinda is a type of sea port which is located in the Mahakam River which has a very important role on economic activity. ;This study examines the legal aspects of a port in the form of Special Terminal Tersus and Port for Own Interest TUKS by the Ministry of Transport of the Republic of Indonesia as well as examine issues related to licensing Tersus and TUKS in Samarinda East Kalimantan Province This study was conducted because of problem of the existence of the non conformance between Law No 17 Year 2008 Regarding on Shipping Government Regulation No 61 Year 2009 on Port with the provisions of Article 46 and Article 47 Regulation of Ministry of Transportation No PM 51 of 2011 on Special Terminal and Terminal for Own Interest In addition there are differences in interpretation of the limits of the Regional Working Environment DLKr and the Regional Environmental Interests Ports DLKp from the Port of Samarinda the harbor master 39 s Office and Port Authority KSOP Samarinda the Directorate General of Sea Transportation of Ministry of Transportation DGST and there is no adjustment to DLKr and DLKp Port Samarinda in accordance with the provisions of Article 351 of Law No 17 2008 The research was conducted in the city of Samarinda province of East Kalimantan because the Port of Samarinda is a type of sea port which is located in the Mahakam River which has a very important role on economic activity. ;This study examines the legal aspects of a port in the form of Special Terminal Tersus and Port for Own Interest TUKS by the Ministry of Transport of the Republic of Indonesia as well as examine issues related to licensing Tersus and TUKS in Samarinda East Kalimantan Province This study was conducted because of problem of the existence of the non conformance between Law No 17 Year 2008 Regarding on Shipping Government Regulation No 61 Year 2009 on Port with the provisions of Article 46 and Article 47 Regulation of Ministry of Transportation No PM 51 of 2011 on Special Terminal and Terminal for Own Interest In addition there are differences in interpretation of the limits of the Regional Working Environment DLKr and the Regional Environmental Interests Ports DLKp from the Port of Samarinda the harbor master 39 s Office and Port Authority KSOP Samarinda the Directorate General of Sea Transportation of Ministry of Transportation DGST and there is no adjustment to DLKr and DLKp Port Samarinda in accordance with the provisions of Article 351 of Law No 17 2008 The research was conducted in the city of Samarinda province of East Kalimantan because the Port of Samarinda is a type of sea port which is located in the Mahakam River which has a very important role on economic activity. , This study examines the legal aspects of a port in the form of Special Terminal Tersus and Port for Own Interest TUKS by the Ministry of Transport of the Republic of Indonesia as well as examine issues related to licensing Tersus and TUKS in Samarinda East Kalimantan Province This study was conducted because of problem of the existence of the non conformance between Law No 17 Year 2008 Regarding on Shipping Government Regulation No 61 Year 2009 on Port with the provisions of Article 46 and Article 47 Regulation of Ministry of Transportation No PM 51 of 2011 on Special Terminal and Terminal for Own Interest In addition there are differences in interpretation of the limits of the Regional Working Environment DLKr and the Regional Environmental Interests Ports DLKp from the Port of Samarinda the harbor master 39 s Office and Port Authority KSOP Samarinda the Directorate General of Sea Transportation of Ministry of Transportation DGST and there is no adjustment to DLKr and DLKp Port Samarinda in accordance with the provisions of Article 351 of Law No 17 2008 The research was conducted in the city of Samarinda province of East Kalimantan because the Port of Samarinda is a type of sea port which is located in the Mahakam River which has a very important role on economic activity. ]"
Jakarta: Fakultas Hukum Universitas Indonesia, 2014
T43043
UI - Tesis Membership  Universitas Indonesia Library
cover
Fadhil Azharrisman
"Penelitian ini membahas mengenai perancangan dan perhitungan palka ikan untuk kapal ikan 30 GT menggunakan kapal yang dirancang khusus. Pada penelitian ini pendinginan palka ikan menggunakan sistem refrigerasi untuk mengoptimalkan volume ruangan palka karena, dalam pengoperasiannya palka berpendingin es membutuhkan 50% dari kapasitas ruang palka untuk memuat es. Dalam penelitian ini, dilakukan studi literatur guna menentukkan parameter perhitungan, desain geometrik palka, dan dilakukan simulasi CFD menggunakan Ansys Fluent untuk menilai bentuk aliran fluida pendingin dan waktu pendinginan produk, lalu dilanjutkan dengan perhitungan beban pendinginan dan kebutuhan daya listrik yang dibutuhkan untuk sistem pendingin yang telah dirancang. Berdasarkan hasil simulasi didapatkan waktu pendinginan paling cepat terjadi ketika kecepatan inlet fluida pendingin 8 m/s pada kapasitas pemuatan 100% dengan waktu pendinginan ikan dari 27°C sampai 0°C membutuhkan waktu selama 4 jam 15 menit, serta kebutuhan daya total untuk sisterm refrigerasi yaitu 5,88 kW.

This study discusses the design and calculation of fish hold for 30 GT fishing vessels using specially designed vessels. In this study, fish hold cooling uses a refrigeration system to optimize the volume of the hold because, in its operation, the ice-cooled hatch requires 50% of the capacity of the hold to load ice. In this study, a literature study was conducted to determine the calculation parameters, geometric design of the hold, and a CFD simulation was carried out using Ansys Fluent to review the shape of the cooling fluid flow and product cooling time then continued with the calculation of the cooling load and the electrical power required for the cooling system has been designed. Based on the simulation results, the fastest cooling time occurs when the cooling fluid inlet velocity is 8 m/s at a loading capacity of 100% with a cooling time of fish from 27°C to 0°C which takes 4 hours 15 minutes, as well as the total power requirement for the refrigeration system is 5.88 kW."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mohammad Luthfi Setyana
"Penilitian ini membahas tentang retrofit sistem pendingin mesin untuk kapal coaster 1200GT dengan menggunakan sistem keel cooler. Dimana proses untuk mengganti suatu sistem yang sudah ada yang disebut retrofiting. Kapal coaster 1200GT merupakan kapal pengangkut barang untuk pelayaran pantai. Kapal ini memiliki spesifikasi panjang keseluruhan ( ), panjang diantara garis tegak lurus ( ), lebar kapal ( ), tinggi kapal ( ), sarat kapal ( ), tenaga mesin utama ( ), kecepatan maksimum kapal ( ) dan dapat menampung penumpang sebanyak 400 orang. Tujuan penelitian ini adalah merancang kebutuhan keel cooler untuk kapal coaster 1200GT. Langkah-langkah kegiatan perancangan dan perhitungan keel cooler ini adalah sebagai berikut: menghitung kebutuhan keel cooler dengan variasi diameter ½ - 2 ½ inch untuk mengetahui berapa panjang (L) minimal dan nilai optimal dari nilai pelepasan panas (q). Variasi diameter menghasilkan beberapa nilai panjang dan nilai koefisien perpindahan panas yang bervariasi. Pada diameter 2½ inch memiliki nilai panjang minimal dan nilai pelepasan panas yang optimal.

This research discusses about retrofit of the engine cooling system for coaster ship 1200GT with a keel cooler system. Where the process to replace an existing system called Retrofitting. 1200GT coaster ship is a freighter ship to cruise the beach. This ship has the following specifications: length overall specification ( ), the length between perpendiculars ( ), the breadth ( ), height ( ), draft ( ), the main engine power ( ), the maximum speed of the ship ( ) and can accommodate as many as 400 passengers. The purpose of this research is to design requirements for ship's keel cooler coaster 1200GT. Step-by-step activities keel cooler design and calculation are as follows: calculate the keel cooler needs to variation in diameter ½ - 2 ½ inch to know how long ( ) minimum and the optimal value of the heat release ( ). Variations in diameter produced some length value and the value of heat transfer coefficient varies. At a diameter of 2½ inch has a minimum long value and optimal value of the heat release.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S57716
UI - Skripsi Membership  Universitas Indonesia Library
cover
Helmi Dadang Ardiansyah
"Ice Slurry adalah sebuat teknologi langka di Indonesia. Bentuk dan proses pembuatan yang sangat unik membuat ice slurry mempunyai kelebihan diantara es dan air. Dalam aplikasinya sudah mulai banyak diterapkan sebagai pendingin gedung dan pendingin ikan nelayan. Indonesia adalah negara maritime sehingga mata pencaharian nelayan sangat banyak. Namun mata pencaharian tersebut tidak populer karena pendapatan yang kecil. Banyak hal yang dapat dilakukan untuk meningkatkan perekonomian nelayan salah satunya penerapan ice slurry sebagai media pendingin ikan.
Tujuan dari penelitian ini adalah mengetahui karakteristik ice slurry berbahan dasar air laut dengan variasi salinitas. Variasi salinitas yang digunakan maksimum 30 ppt, 26 ppt, 22 ppt dan 18 ppt. Untuk pengujian dilakukan pada alat scraper ice slurry generator karena hasil fraksi es yang lebih besar. Temperatur fan condenser, rpm motor, dan volume beban sama untuk semua variasi. Selain itu juga dilakukan variasi beban evaporator dari sistem pendingin.
Hasilnya adalah salinitas rendah lebih menghasilkan fraski es dibanding salinitas tinggi, namun terdapat es balok pada hasil ice slurry. Enthapi terendah pada salinitas rendah sedangkan viskositas dan konduktivitas termal tertinggi di salinitas terendah. Kesimpulan ini didukung oleh variasi beban evaporator yang menunjukkan hasil sama untuk kalor 1.718 kW dan 2.947 kW.

Ice Slurry is a rare technology in Indonesia. Shape and procces ice slurry is unique, so ice slurry have many advantages between ice and water for cooling system. Ice slurry application has been applied as building cooling and fish cooling. Indonesia is maritime country so many people work as fisher. But actually that job now isn?t popular because small income. Many effort to increase economic of Indonesia fisher, the one of solution is ice slurry as fish cooling in above their ship.
The purpose from this research is to know characteristic of ice slurry based on sea water with salinity variant. The variations are 30 ppt, 26 ppt, 22 ppt and 18 ppt. The experiment used scraper ice slurry genearator because result of ice fraction is bigger than the others. Temperature fan in condenser, rpm motor, and volume are same every experiment. The others variation is evaporator load with same parameter.
The result in low salinity produced big fraction es compare with high salinity, but in the result ice slurry contain ice beam. Conclutsion from calculated of result ice slurry is low enthapy on low salinity, the big value of viscous and conductivity thermal on low salinity. The conclusion has supported with variation of load evaporator that presented result as trend as for 1.718 kW and 2.947 kW.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42071
UI - Skripsi Open  Universitas Indonesia Library
cover
Kemal Rahadian
"ABSTRAK
Solar Thermal Cooling System with its absorption cycle is expected to
replace the conventional air conditioning system with vapor compression cycle
because it is more efficient in terms of cost and energy. However, due to the heat
of the sun is not always stable, the system needs to be equipped with a backup
energy source, one of which is CNG. In the Manufacturing Research Center
building, the lack of facilities that support availability of CNG causes large
operating costs. Therefore, Optimization efforts with the aim to reduce operating
costs are needed. Simulation and optimization performed with EnergyPlus and
GenOpt. The conclusion is that the installation of 100 kW electric heater tankless
hot water storage tank is able to reduce total operating costs by 34.95% compared
to the use of a combination of solar thermal and CNG and 49.92% compared with
the full use of CNG.

ABSTRACT
Solar Thermal Cooling System with its absorption cycle is expected to
replace the conventional air conditioning system with vapor compression cycle
because it is more efficient in terms of cost and energy. However, due to the heat
of the sun is not always stable, the system needs to be equipped with a backup
energy source, one of which is CNG. In the Manufacturing Research Center
building, the lack of facilities that support availability of CNG causes large
operating costs. Therefore, Optimization efforts with the aim to reduce operating
costs are needed. Simulation and optimization performed with EnergyPlus and
GenOpt. The conclusion is that the installation of 100 kW electric heater tankless
hot water storage tank is able to reduce total operating costs by 34.95% compared
to the use of a combination of solar thermal and CNG and 49.92% compared with
the full use of CNG."
Fakultas Teknik Universitas Indonesia, 2014
S54286
UI - Skripsi Membership  Universitas Indonesia Library
cover
Damora Rhakasywi
"Perkembangan industri elektronik untuk produk berkinerja tinggi yang ditandai dengan munculnya piranti elektronika berukuran minimalis serta menggunakan daya yang rendah memerlukan sebuah sistem pendinginan yang handal dan efisien sehingga mampu beroperasi secara optimum. Pada penelitian ini teknologi yang digunakan untuk mendinginkan komponen piranti elektronika tersebut menggunakan jet sintetik yang memanfaatkan gerakan membran secara kontinyu dengan menghasilkan cincin vortex untuk mempercepat proses perpindahan panas.
Penelitian yang dilakukan pada study ini bertujuan untuk mencari nilai frekuensi, jenis gelombang eksitasi, serta bentuk orifis jet sintetik yang menghasilkan performa pendinginan yang baik untuk model jet sintetik impinging, mencari pengaruh jarak tumbukan (impact) jet sintetik impinging terhadap laju perpindahan panas konveksi untuk proses pendinginan, mencari model cavity jet sintetik impinging dan jet sintetik cross flow yang memiliki kehandalan dalam proses pendinginan.
Penelitian ini dikerjakan menggunakan pendekatan komputasional dan eksperimental. Pada pendekatan komputasional digunakan software CFD (computational fluid dynamics) yang mendefinisikan kondisi batas jet sintetik dengan asumsi dinding bergerak (moving wall) dan model turbulensi k-omega SST (Shear Stress Transport). Kemudian model uji eksperimental menggunakan model jet sintetik tipe impinging dan model jet sintetik tipe cross flow. Model-model tersebut memiliki perbedaan dalam hal arah aliran jet sintetik terhadap media yang akan didinginkan berupa heatsink. Modus eksitasi yang dipergunakan untuk menghasilkan aliran jet sintetik tersebut menggunakan sinyal listrik berupa gelombang sinusoidal, square dan triangular dengan variasi frekuensi 80 Hz, 120 Hz dan 160 Hz. Sinyal listrik tersebut dihasilkan oleh sweep function generator.
Hasil yang diperoleh dari kajian komputasional dan eksperimental tersebut memberikan informasi bahwa jet sintetik mampu memberikan efek pendinginan pada objek yang akan didinginkan. Parameter dari variasi frekuensi eksitasi jet sintetik dan arah aliran jet sintetik memberikan efek yang beragam dalam hal pendinginan. Dari hasil penelitian yang dilakukan tersebut diperoleh modus eksitasi yang paling baik menggunakan gelombang eksitasi square 120 Hz untuk model jet sintetik impinging kemudian kombinasi gelombang eksitasi sinusoidal 120 Hz dan square 80 Hz memberikan efek pendinginan yang paling optimum untuk tipe jet sintetik cross flow. Konsumsi energi yang dibutuhkan oleh jet sintetik sebanyak 1,78 joule untuk menurunkan temperatur dari 53°C menjadi 48,2°C sedangkan kipas menghabiskan konsumsi energi sebanyak 142,2 joule untuk dapat menurunkan temperatur dari 53°C menjadi 48,2°C.

The development of the electronics industry for high performance products are characterized by the emergence of electronic devices minimalist size and low power required to use a cooling system that is reliable and efficient thus able to operate at its optimum. In this study, the technology used to cool electronic devices such components using synthetic jet which utilizes a continuous membrane movement by generating vortek ring to accelerate the process of heat transfer. Research conducted in this study aimed to explore the value of frequency, type of wave excitation, as well as the shape of the synthetic jet orifice produces good cooling performance for the model synthetic jet impinging, collision distance for influence synthetic jet impinging on the rate of convection heat transfer to the cooling process, looking for synthetic jet impinging cavity models and synthetic jet cross flow which has reliability in the process of cooling.
The study is done using the method of using computational and experimental approaches. In the computational approach used CFD (computational fluid dynamics) software which defines the boundary conditions assuming a synthetic jet moving wall model with k-omega SST (Shear Stress Transport) turbulence. Then test the model using the experimental model of type impinging synthetic jet and model of synthetic jet cross flow type. The models differ in terms of synthetic jet flow direction of the media that will be cooled heatsink. Mode excitation is used to produce the synthetic jet flow using electrical signals in the form of waves sinusoidal, square dan triangular with variations in frequency of 80 hz, 120 hz and 160 hz. The electrical signals generated from the tool named sweep function generator.
Results obtained from the computational and experimental information that synthetic jets can provide a cooling effect on the object to be cooled. Parameters of synthetic jet excitation frequency variation and direction of flow of synthetic jet placement varied effects in terms of cooling. From the results of the research conducted most excitation modes obtained using either 120 hz square wave excitation for the type of impinging synthetic jet models then the combination of 120 hz sinusoidal excitation wave and 80 hz square provide the most optimum cooling effect for condition type cross flow model of synthetic jet. Energy consumption required by the synthetic jet 1.78 joules to lower the temperature of 53°C - 48.2°C while fans spend energy consumption 142.2 joule to be able to lower the temperature of 53°C-48.2°C.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
D1899
UI - Disertasi Membership  Universitas Indonesia Library