Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 130482 dokumen yang sesuai dengan query
cover
Julian Aditya Winarto
"Penelitian ini menyelidiki tantangan dalam mempertahankan konsentrasi klor bebas yang ideal di sistem distribusi air perkotaan. Menggunakan Instalasi Pengolahan Air (IPA) Legong dan Perumahan Harapan Baru Taman Bunga (HBTB) sebagai lokasi studi kasus, penelitian ini bertujuan untuk menganalisis konsentrasi klor bebas di tiga titik kritis jaringan distribusi IPA Legong: outlet reservoir, dua titik perantara yang mewakili jaringan distribusi utama, dan titik terjauh di HBTB. Penelitian juga mengevaluasi pengaruh jumlah klor yang digunakan dalam proses desinfeksi IPA Legong terhadap konsentrasi klor bebas dalam jaringan. Menggunakan WaterGEMS, studi ini menilai beberapa skenario dosis klor dan dampaknya terhadap konsentrasi klor bebas di wilayah pelayanan. Metodologi utama meliputi pengukuran sisa klor, studi laboratorium kualitas air lainnya, dan perbandingan dengan baku mutu. Simulasi WaterGEMS dilakukan untuk menilai dampak skenario dosis klor. Hasilnya adalah, kualitas air tetap aman di waduk dan jarak-7 km, tetapi memburuk mendekati HBTB pada jarak-10 km, dengan konsentrasi klor bebas menurun. Terdapat korelasi kuat antara klor bebas dan total klor dalam sistem distribusi. Terdapat tiga skenario pemodelan yang dijalankan menggunakan WaterGEMS, dan dari ketiga skenariro tersebut masih belum ada yang memenuhi secara keseluruhan. Akan tetapi, skenario yang dapat dinilai cukup dan paling efektif secara berurutan adalah skenario di mana konsentrasi klor bebas di outlet reservoir bernilai maksimum di 5 mg/L dan juga skenario di mana beberapa variasi jumlah konsentrasi klor bebas diinjeksi di tujuh titik yang tersebar di perumahan HBTB.

This research investigates the challenges of maintaining ideal free chlorine concentrations in urban water distribution systems. Using the Legong Water Treatment Plant (WTP) and Harapan Baru Taman Bunga Housing (HBTB) as case study sites, this research aims to analyse the free chlorine concentration at three critical points of the Legong WTP distribution network: the reservoir outlet, two intermediate points representing the main distribution network, and the furthest point at HBTB. The study also evaluated the effect of the amount of chlorine used in the Legong IPA disinfection process on the free chlorine concentration in the network. Using WaterGEMS, the study assessed several chlorine dosing scenarios and their impact on free chlorine concentrations in the service area. The main methodologies included residual chlorine measurements, other water quality laboratory studies, and comparison with quality standards. WaterGEMS simulations were conducted to assess the impact of the chlorine dosing scenarios. The result was that water quality remained safe at the reservoir and at a distance of 7 km but deteriorated close to HBTB at a distance of 10 km, with free chlorine concentration decreasing. There is a strong correlation between free chlorine and total chlorine in the distribution system. There were three modelling scenarios run using WaterGEMS, and none of them met the overall requirements. However, the scenarios that could be considered sufficient and most effective respectively were the scenario where the free chlorine concentration at the outlet of the reservoir was maximum at 5 mg/L and the scenario where several varying amounts of free chlorine concentration were injected at seven points spread across the HBTB housing estate."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Andrew Alexander Lamba
"PDAM Tirta Kahuripan cabang pelayanan 2 mengalami kehilangan air sebesar 15,39% pada bulan oktober 2014. Untuk meningkatkan pelayanan distribusi air bersih, diperlukan sebuah langkah pengoptimalan kinerja jaringan distribusi berupa pemeriksaan kecepatan aliran air dalam pipa dan tekanan pada setiap junction pada jaringan distribusi. Adapun kriteria desain yang menjadi acuan dalam mengoptimalkan kinerja jaringan distribusi yaitu kecepatan dalam pipa tidak boleh kurang dari 0,15 m/dt dan tidak boleh lebih dari 1,5 m/dt serta tekanan air yang ideal adalah tidak kurang dari 10 m dan tidak lebih dari 80 m. Hasil evaluasi dari penelitian ini menemukan permasalahan kecepatan aliran air dalam pipa, yaitu terdapat kecepatan aliran air yang nilainya dibawah 0,15 m/dt dan diatas 1,5 m/dt. Sedangkan nilai tekanan pada setiap junction telah memenuhi kriteria desain, dengan nilai tekanan yang terendah sebesar 26,55 m dan nilai tekanan yang tertinggi sebesar 61,84 m. Hasil evaluasi ini menjadi bahan pertimbangan dalam mengoptimalkan kinerja jaringan distribusi air bersih dengan menggunakan aplikasi EPANET 2.0 dan WaterGEMS. Pengoptimalan kinerja jaringan distribusi dilakukan dengan cara mengganti diameter dan material pipa. Setelah dilakukan 4 penggantian pipa yang diameternya diperbesar dan 9 penggantian pipa yang diameternya diperkecil.

PDAM Tirta Kahuripan service branch 2 experienced water loss by 15.39% in October 2014. In order to improve the water distribution services, needed a distribution network performance optimization step of the examination of water in the pipe flow velocity and pressure at every junction in the distribution network. The criteria for the reference design in optimizing the performance of the distribution network that the speed in the pipe should not be less than 0.15 m / s and should not be more than 1.5 m / s and the ideal water pressure is not less than 10 m and not more of 80 m. Results of the evaluation of the study found the problem of water flow velocity in the pipe, which contained water flow velocity value is less than 0.15 m / s and above 1.5 m / s. While the value of pressure at each junction has met the design criteria, the lowest pressure value amounted 26.55 m and the highest pressure value amounted to 61.84 m. The results of this evaluation into consideration in optimizing the performance of water distribution networks using EPANET 2.0 and WaterGEMS application. Distribution network performance optimization is done by replacing the pipe diameter and material. After 4 replacement pipe whose diameter is enlarged and 9 replacement pipe whose diameter is reduced."
Depok: Fakultas Teknik Universitas Indonesia, 2015
S60313
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fildzah Dhira Lestari
"ABSTRAK
Kebocoran jaringan pipa distribusi air bersih dapat menimbulkan risiko keselamatan air bersih berupa kontaminasi air dan penyebaran penyakit melalui air. Sehingga dalam mendukung, mengevaluasi, dan meningkatkan manajemen keselamatan air pada jaringan pipa distribusi, digunakan metode pendekatan kuantitatif salah satunyaQuantitative Microbial Risk Assessment (QMRA). Penelitian ini bertujuan untuk mengetahui kualitas air bersih terutama parameter E. coli di jaringan pipa distribusi, menganalisis penilaian risiko keterpajanan E. coli O157:H7, mengidentifikasi risiko penilaian efek kesehatan dan menganalisis karakter risiko bakteri tersebut. Metode penelitian menggunakan metode QMRA, yaitu identifikasi bahaya, penilaian paparan, penilaian efek kesehatan dengan model Beta-Poisson, dan karakterisasi risiko. Tahap identifikasi bahaya menetapkan paparan E. coli O157:H7 berasal dari air PDAM, dimana jalur paparannya adalah unboiled water, dengan rute paparan melalui proses menelan akibat aktivitas pemakaian air PDAM sehari-hari. Terdapat dua tipe penggunaan air, yaitu penggunaan air secara langsung dari jaringan pipa distribusi dan air dialirkan menuju tangki air. Identifikasi bahaya dilakukan dengan pemeriksaan kualitas air pada jaringan pipa distibusi, bahwa hasil menunjukkan kualitas air telah memenuhi Peraturan Menteri Kesehatan Republik Indonesia No. 492 Tahun 2010 untuk parameter fisik dan kimia. Namun untuk parameter biologis, konsentrasi E. colimaksimum ditemukan 49 MPN100 mL pada 1 responden (20) yang menggunakan tangki air. Penilaian paparan untuk menentukan dosis paparan akibat E. coli O157:H7 mendapatkan besarnya rata-rata kurang dari 0,01090,0026 organismeL dan 0,01440,0041 organismeL saat pemakaian air minimum dan maksimum. Dosis paparan meningkat pada responden yang menggunakan tangki air sebesar 946 dan 860 saat penggunaan air minimum dan maksimum. Tahap penilaian efek kesehatan menggunakan model Beta-Poisson dengan dan adalah 0,0571 dan 2,2183 mendapatkan bahwa rata-rata probabilitas infeksi harian pada jaringan pipa distribusi PDAM adalah kurang dari adalah 2,800x10-46,723x10-5 dan 3,698x10-41,046x10-4saat pemakaian air minimum dan maksimum. Bagi responden yang menggunakan tangki air, probabilitas infeksi harian meningkat sebesar 876 dan 785 saat penggunaan air minimum dan maksimum. Sehingga, pada tahap karakterisasi risiko, probabilitas infeksi tahunan adalah kurang dari 9,598x10-22,205x10-2 dan 1,236x10-13,127x10-2 saat pemakaian air minimum dan maksimum. Bagi responden pengguna tangki air, probabilitas infeksi tahunan meningkat sebesar 271 dan 204 saat penggunaan air minimum dan maksimum. Karena itu, evaluasi parameter fisik, kimia dan biologi perlu dilakukan berdasarkan waktu dan wilayah untuk meningkatkan performansi IPAB dan keselamatan konsumen.

ABSTRACT
Pipe leakage of clean water distribution network can cause clean water safety risks in the form of water contamination and waterborne disease. So that, in supporting, evaluating, and improving water safety management in distribution pipe network, a quantitative approach is used, which is Quantitative Microbial Risk Assessment (QMRA). This study aims to study the quality of clean water, especially E. coli in distribution pipe network; analyzing the exposure assessment of E. coli O157:H7, identification the risk of health effects assessment and analyzing the risk character. The research method uses QMRA method, namely hazard identification, exposure assessment, health effects assessment with Beta-Poisson model, and risk characterization. Hazard identification determines exposure of E. coli O157:H7 come from PDAM water, which the exposure path is unboiled water, with route of exposure through ingestion due to daily PDAM water usage activities. There are two types of water usage, its water usage directly from water distribution pipe and through water tank. Examining water quality carries out hazard identification, which water quality on the PDAM distribution pipe network has fulfilled the Regulation of the Minister of Health of the Republic of Indonesia No. 492 in 2010 for physic and chemical parameter. However, in biologic parameter, the maximum E. coli concentration was found to be 49 MPN100 mL in 1 respondent (20), who used water tank. Exposure assessment determines the exposure dose of E. coli O157:H7 on clean water distribution pipe network with the averages of doses are less than 0,01090,0026 organismsL and less than 0,01440,0041 organismsL at minimum and maximum of water usage, respectively. The exposure dose increase when the respondent use water tank, its 946 and 860 at minimum and maximum water usage. Health effects assessment usingBeta-Poisson model with and are 0,0571 and 2,2183, respectively. The averages of daily probability of infection on clean water distribution pipe network in PDAM are less than 2,800x10-46,723x10-5 and less than 3,698x10-41,046x10-4 at minimum and maximum of water usage, respectively. Respondent, who use water tank, have increased the daily probability of infection to 876 and 785 at minimum and maximum water usage. So that, in risk characterization, the annual probability of infection are less than 9,598x10-22,205x10-2 and 1,236x10-13,127x10-2 at minimum and maximum of water usage, respectively. For respondent who use water tank, it has increased to 271 and 204 at minimum and maximum of water usage, respectively. Therefore, evaluation in physic, chemical, and biology parameters needs to be done based on time and region to improve WTP performance and consumer safety.
"
2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Moko Prabowo
"Semakin meningkatnya pembangunan gedung perkantoran ataupun bangunan bertingkat lainya, maka kebutuhan akan air bersih semakin meningkat Perhitungan SDAB pada banguna bertingkat clapat diselesaikan dengan berbagai cara. Salah satunya dengan bantuan komputer serta berlaku untuk semua pola janngan pipa pada bangunan berlingkat. Program komputer dengan bahasa Basic dalam hal ini visual basic disusun untuk perhitungan pendimensian pipa ait bersih yang memberikan proses perhitungan yang meminimaikan pemakaian tabel-label atau nomogram. Alogoritma dari program terdiri dari perhitungan kebutuhan air bersih pada suatu bangunan bertingkat, perhitungan kapasitas tangki bawah dan atas serta pendimensian pipa dan juga kapasitas serta daya pompa yang dibutuhkan. Hasil perhitungan ini dibandingkan dengan hasil perhitungan konsultan perencana mekanilkan dan electrical pada proyek Kawan lama Center. Perbedaan hasil dari kedua perhitungan memperlihatkan adanya perbedaan pada pernitungan kapasita tangki, Serta hasil yang oukup untuk pendimensian pipa. Program ini dioperasikan pada personal komputer dengan media Windows'95) (Bahasa pemograman Visual basic 4,0)."
Depok: Fakultas Teknik Universitas Indonesia, 1997
S35579
UI - Skripsi Membership  Universitas Indonesia Library
cover
Moh. Irfan Muhsin Siddik
"Kota Yogyakarta termasuk dalam kategori kota sedang. Sebuah kota memerlukan sarana dan prasarana untuk mendukung kehidupan warganya, diantaranya pengelolaan sarana air limbah.
Tugas Akhir ini akan mengevaluasi sistem jaringan pengumpulan air limbah di Kotamadya Yogyakarta, dengan Cara menganalisis data yang ada pada tahun 1995 dibandingkan dengan prediksi pada tahun 2006 dengan parameter : jumlah penduduk, kepadatan penduduk, sarana air bersih, debit air limbah, dimensi pipa, serta biaya yang dibutuhkan untuk investasi jaringan.
Evaluasi yang telah dilaksanakan, menunjukkan bahwa jaringan pengumpulan air limbah domestik yang ada (tahun 1996) masih dapat digunakan untuk jangka waktu jaringan baru masing-masing sepanjang 600 m pads ~ 300, 1,100 m pada ~ 350, 1.600 m pada ~ 400, 5.097 m pada &oslah; 450, 1,200 m pada &oslah; 520 dan 300 m pada &oslah; 650."
Depok: Fakultas Teknik Universitas Indonesia, 2001
S35641
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fioret, Cameron
New York: Bloomsbury Academic, 2023
363.61 FIO e
Buku Teks SO  Universitas Indonesia Library
cover
Rudy Setiabudy
Fakultas Teknik Universitas Indonesia, 1996
LP 1996 03.pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Alif Azadi Taufik
"ABSTRACT
The performance of humanitarian logistics is a crucial factor of disaster response operations. With predictions of increase rate and impact of disasters in Indonesia, improving the performance of humanitarian logistics of humanitarian organizations in this disaster prone nation is important. Using the Indonesian Red Cross rsquo s recent water distribution operation as a response to the 2017 Mount Agung Eruptions, this thesis aims to understand the activities, problems, success parameters and possible improvements of that operation. This thesis utilizes a computer simulation to replicate and experiment on the study case rsquo s operational system. The thesis found that the operation involved supplying, scheduling, transporting, ordering, and distributing as the main activities, discovered long time needed to fulfill demand as a logistical problem, identified time as the most crucial success parameter, and found that increasing transportation resources, sharing transportation resources, and maintaining inventory levels as significant and positive improvements to the study case operation.

ABSTRACT
Kinerja logistik kemanusiaan menjadi faktor penting dalam operasi tanggap bencana. Dengan adanya prediksi bahwa tingkat dan dampak bencana di Indonesia akan meningkat, maka meningkatkan logistik kemanusiaan di organisasi kemanusiaan di negara rawan bencana ini sangat penting. Menggunakan operasi distribusi air oleh Palang Merah Indonesia sebagai tanggapan kepada Erupsi Gunung Agung 2017 sebagai studi kasus, skripsi ini bertujuan untuk mengetahui aktivitas, masalah, parameter kesuksesan, dan perbaikan yang mungkin dari operasi tersebut. Skripsi ini menggunakan simulasi komputer untuk mereplikasikan dan melakukan eksperimen terhadap sistem operasi studi kasus. Skripsi ini menemukan bahwa operasi tersebut melibatkan penyediaan air, penjadwalan, transportasi, pemesanan, dan distribusi sebagai aktivitas utama, menemukan waktu yang lama untuk memuaskan permintaan sebagai masalah logistik, mengidentifikasi bahwa waktu adalah parameter sukses yang terpenting, dan menemukan bahwa meningkatkan sumber daya transportasi, membagi sumber daya transportasi, dan menjaga tingkat persediaan adalah perbaikan signifikan dan positif terhadap operasi studi kasus."
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ghea Almira Mafaza
"Perusahaan distributor Air Minum Dalam Kemasan (AMDK) yang berlokasi di Semarang memiliki dua kendaraan untuk melakukan distribusi ke 16 lokasi distribusi di dalam Semarang dengan berbagai macam ukuran AMDK. Permasalahan yang dihadapi yaitu perusahaan melakukan distribusi tanpa memperhitungkan jarak tempuh, kuantitas permintaan yang berbeda-beda di setiap lokasi, keterbatasan jumlah dan kapasitas kendaraan, serta lokasi pelanggan yang tersebar di Semarang. Penelitian perlu dilakukan dengan menggunakan Capacitated Vehicle Routing Problem (CVRP) untuk mendapatkan rute distribusi yang optimal serta mendapatkan jarak dan waktu tempuh distribusi optimal bagi perusahaan. Penelitian ini menggunakan pendekatan Mixed Integer Linear Programming (MILP) dengan metode branch and bound. Model matematika dibuat dan diterjemahkan ke dalam bahasa pemrograman LINGO untuk dijalankan dan menghasilkan rute optimal. Hasil pada penelitian ini yaitu didapatkan dua rute optimal untuk setiap kendaraan 1 dan 2 melakukan distribusi AMDK ke 16 lokasi. Jumlah muatan juga didapatkan untuk masing-masing rute dengan tidak melebihi kapasitas kendaraan. Total jarak yang ditempuh berkurang sebesar 28% dan dapat menghemat total waktu tempuh sebesar 11%. Analisis sensitivitas dilakukan dengan mengubah parameter permintaan dan hasilnya yaitu terjadi penambahan rute menjadi 3 rute ketika kondisi kenaikan permintaan sebesar 5%, 10%, dan 15% serta terdapat pengaruh perubahan pada rute, jarak, dan waktu tempuh ketika kondisi penurunan permintaan 15% serta kondisi kenaikan permintaan 5%, 10%, dan 15%.

Packaged Drinking Water distributor company located in Semarang has two vehicles for distribution to 16 distribution locations in Semarang with various sizes of packaged drinking water. The problem faced is that the company distributes without taking into account the distance traveled, the quantity of demand that varies in each location, the limited number and capacity of vehicles, and customer locations spread across Semarang. Research needs to be done using the Capacitated Vehicle Routing Problem (CVRP) to get the optimal distribution route and the optimal distribution distance and travel time for the company. This study uses the Mixed Integer Linear Programming (MILP) approach with the branch and bound method. Mathematical models are created and translated into the LINGO programming language to run and generate optimal routes. The results of this study are that there are two optimal routes for each vehicle 1 and 2 to distribute packaged water to 16 locations. The load amount is also obtained for each route without exceeding the vehicle capacity. The total distance traveled is reduced by 28% and can save the total travel time by 11%. Sensitivity analysis was carried out by changing the demand parameters. The result was additional routes into three when the demand increased conditions of 5%, 10%, and 15%. There was an effect of changes in routes, distances, and travel time when conditions decreased by 15% and conditions increased in demand by 5%, 10%, and 15%."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Syahril
"Perencanaan Sistem Distribusi Air Bersih (SDAB) merupakan perhitungan yang rumit bila dilakukan secara manual (tanpa bantuan program). Dasar perhitungan dengan rnenggunakan program komputer ini didasarkan atas metoda Hardy Cross. Dalam perencanaan serta perhitungan headless akilpat adanya sarnbungan-sambungan pada pipa, pembahan arah aliran, perubahan besar diameter pipa (minor losses), dapat diabaikan terutama untuk pipa dengan diameter yang cukup besar dan panjang Jadi headloss yang diperhitunglcan disini adalah akibat geseran sepanjang pipa (major losses).
Penentuan jenis material pipa merupakan salah satu hal yang cukup penting dalam perencanaan SDAB terutama menyangkut masalah biaya konstruksi. Selain itu juga dilakukan perhitungan untuk kapasitas reservoar yang dalam perencanaan ini menggunakan reservoar atas Pompa juga mempakan komponen yang penting daiam perpipaan, dimana untuk menghitung kapasitas pompa perlu diketahui sifat-sifat pompa, bila pompa tersebut digunakan baik secara paralel maupun sexi.
Salah satu masalah yang culcup sulit dalam perencanaan SDAB ini adalah master plan yang dapat berubah setiap waktu sehingga setiap hasil perhitungan yang didapat harus dianalisa kembali apakah perhitungan itu masih memenuhi kxiteria yang diinginkan untuk beberapa tahun mendatang."
Depok: Fakultas Teknik Universitas Indonesia, 1996
S34248
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>