Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 48480 dokumen yang sesuai dengan query
cover
Sitorus, Tulus Burhanuddin
"This study investigates the performance of a solar adsorption refrigerator using activated alumina and methanol adsorption pair. The experiments were carried out for 24-hour. The refrigeration was completed during seven cycles with varying weather conditions. A flat plate type collector was used with an area of 0.25 m2 and tilt angle of 30o. Theoretical calculations show that, the maximum collector efficiency is 47.15% when the maximum solar radiation obtained is 936.9 W/m2. In this research, the maximum value of the COP is 0.0991 when the total solar energy is 16.485 MJ/m2 and the minimum value obtained is 0.0919 when the total solar energy is 7.609 MJ/m2. The experiment results show that the adsorption pair system can deliver an evaporator temperature of about 9.92°C and the cooling load can be achieved by a heat source with a temperature range of 83.95°C and 95.39oC."
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:5 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Sitorus, Tulus Burhanuddin
"This study investigates the performance of a solar adsorption refrigerator using activated alumina and methanol adsorption pair. The experiments were carried out for 24-hour. The refrigeration was completed during seven cycles with varying weather conditions. A flat plate type collector was used with an area of 0.25 m2 and tilt angle of 30o. Theoretical calculations show that, the maximum collector efficiency is 47.15% when the maximum solar radiation obtained is 936.9 W/m2. In this research, the maximum value of the COP is 0.0991 when the total solar energy is 16.485 MJ/m2 and the minimum value obtained is 0.0919 when the total solar energy is 7.609 MJ/m2. The experiment results show that the adsorption pair system can deliver an evaporator temperature of about 9.92°C and the cooling load can be achieved by a heat source with a temperature range of 83.95°C and 95.39°C."
2016
AJ-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
Edy Susanto
"Many household refrigerator owners do not control their thermostat settings. However, doing this could save energy consumption and also maintain the quality of stored food. This study presents the effect of regulated thermostat settings on household refrigerator energy consumption. The experiment was performed in a room chamber conditioned to temperature control at 25oC. A household refrigerator was used as a test unit, with a cooling load placed inside the freezer component. The cooling load used was an M-package, in accordance with SNI IEC 15502: 2008. The test results reveal that household refrigerator energy consumption increases with higher thermostat settings. Increases in energy consumption range from 17.10% to 18.65%, depending on the thermostat setting."
Depok: Faculty of Engineering, Universitas Indonesia, 2018
UI-IJTECH 9:2 (2018)
Artikel Jurnal  Universitas Indonesia Library
cover
Tandberg-Hanssen, Einar
London: Blaisdell, 1967
523.7 TAN s
Buku Teks SO  Universitas Indonesia Library
cover
Marque, Christophe, editor
"This book presents current research in solar radio astronomy and shows how well it fits in the exceptional scientific context brought by the current space solar observatories. It essentially contains contributed research and review papers presented during the 2010 Community of European Solar Radio Astronomers (CESRA) meeting, which took place in Belgium in June 2010. "
New York: [Springer, ], 2012
e20425156
eBooks  Universitas Indonesia Library
cover
Abdurrahman Nur Ashri Diasta Fajar Ramadlan
"Pandemi COVID-19 ini telah berlangsung kurang lebih selama 2 tahun lebih yang berasal dari Wuhan, China sejak sekitar bulan November 2019. Selama berlangsungnya pandemi ini, seluruh rakyat dunia menjadi lebih sadar dan peduli terhadap kesehatan masing-masing dan juga lingkungan sekitarnya. Dengan pandemi ini juga berbagai aktivitas normal yang biasanya dilakukan sehari-hari menjadi dibatasi. Dalam upaya untuk mengakhiri pandemi ini, banyak cara yang telah dilakukan oleh seluruh rakyat di dunia. Beberapa diantaranya yaitu dengan cara merekomendasikan, mewajibkan, atau melarang perubahan perilaku tertentu dalam beraktivitas sehari-hari, sementara beberapa negara lain hanya mengandalkan penyediaan informasi terkait pandemi.
Pelacakan kontak COVID-19 merupakan salah satu cara yang dikembangkan pemerintah Indonesia untuk mengatasi pandemi ini. Perangkat lunak pelacakan COVID-19 yang sekarang ini beroperasi menggunakan GPS, kamera telepon genggam dan kode QR. Proses tersebut dapat membuat antrian yang panjang dan memakan waktu yang lebih lama semakin panjang antrian tersebut. Untuk mengatasi antrian panjang dan waktu yang lama, dirancang sebuah cara alternatif untuk melakukan proses check-in menggunakan sistem bluetooth. Dengan bluetooth, pengguna dapat melakukan check-in pada area yang lebih luas pada radius 15 meter dan tidak memerlukan GPS, kamera, ataupun kode QR. Bluetooth ini juga dilengkapi dengan perangkat keras pengisian daya tenaga surya berupa panel surya yang dapat mengisi daya pada baterai selama baterai digunakan oleh bluetooth.

This COVID-19 pandemic has been going on for more or less 2 years originating from Wuhan, China since around November 2019. During this pandemic, all the people of the world have become more aware and concerned about their respective health and also the surrounding environment. With this pandemic, various normal activities that are usually carried out on a daily basis have been restricted. In an effort to end this pandemic, many efforts have been made by all people in the world. Many countries are trying to slow or stop the spread of COVID-19 by recommending, requiring, or prohibiting certain behavioral changes in daily activities, while some other countries rely solely on providing information related to the pandemic.
COVID-19 contact tracing is one of the ways the Indonesian government has developed to deal with this pandemic. The current COVID-19 tracking software operates using GPS, mobile phone cameras and QR codes. Users can visit public places that have a QR code available at certain places to carry out the check-in process. After completing the activity the user can check-out. This process can create a long queue and take longer time the longer the queue. To overcome long queues and long times, an alternative way is designed to carry out the check-in process using a bluetooth system. With bluetooth, users can check-in in a wider area and don't need a GPS, camera, or QR code. This Bluetooth is also equipped with solar charging hardware in the form of solar panels that can charge the battery as long as the battery is used by bluetooth.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Takahiro Nakano
"To solve current environmental problems such as global warming and declination of fossil fuels, use of less energy is essential, particularly in the fields of refrigeration and air conditioning. Thus, simulations using complex mathematical models become vital. Simulation technology faces a major challenge because the language of simulation codes varies depending on the programmer. Thereafter, others cannot duplicate the same simulation technology used by their predecessors. To address this, a modular analysis method that generalizes simulation code has been developed. With this method, the general-purpose software analyzing energy system called “ENERGY FLOW +M,” a software enabling analyses that can be conducted without having to specify the model or the method of analysis used, has also been created. The focus of this study was on the solar collector. As the solar collector uses energy from the sun, it is friendly to the global environment. In order to understand the performance of the solar collector, the construction of a simulation model was carried out. Moreover, models of the solar collector and solar radiation were loaded into “ENERGY FLOW +M” to verify their performance. Thus, this simulator allows us to execute simulations of the solar collector from anywhere via the Internet."
Depok: Faculty of Engineering, Universitas Indonesia, 2011
UI-IJTECH 2:3 (2011)
Artikel Jurnal  Universitas Indonesia Library
cover
Denny Rachmansyah
"Dengan meningkatnya kebutuhan untuk memperoleh sistem pendinginan ruangan yang ramah lingkungan, dibutuhkan perkembangan teknologi yang dapat membantu dalam merendahkan dampak emisi terhadap lingkungan. Sistem pendingin dengan tenaga surya termasuk peluang yang sangat besar dalam mengatasi hal tersebut. Teknologi Absorption Chiller dapat menggantikan kerja kompressor dalam sistem pendingin yang tersedia secara komersil. Penggunaannya pada skala kecil dapat membantu menghasilkan kapasitas pendingin 5 kW dengan penelitian menggunakan simulasi sistem Single-Effect Ammonia Water Absorption Chiller menggunakan metode termodinamika untuk menghasilkan COP dari batasan masalah yang telah disesuaikan sebesar 0.334. Dengan tujuan untuk menghasilkan model sistem absorption untuk menentukan jenis heat exchanger dan dimensinya. Kemudian melakukan permodelan dynamic untuk mengetahui berapa banyak jumlah ammonia dan water yang dibutuhkan dengan kapasitas pendingin tertentu.

With the increasing need for environmentally-friendly indoor cooling systems, there is a need for technological developments that can help reduce the impact of emissions on the environment. Solar-powered cooling systems are a huge opportunity to overcome this. Chiller Absorption Technology can replace the work of a compressor in a commercially available cooling system. Its use on a small scale can help produce low cooling capacity by research using a simulation of the Single-Effect Ammonia Water Absorption Chiller system using a thermodynamic method to produce a COP with certain boundary of 0.334. With the aim of producing an absorption system model to determine the type of heat exchanger and its dimensions. Then do dynamic modeling to find out how much ammonia and water are needed with a certain cooling capacity."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Subadi
"Karya tulis ini berisikan suatu tinjauan dan perbaikan mengenai tidak tercapainya temperatur yang dilnginkan dari "Laboratorium Pengujian Lemari Pendingin". Dalam suatu sistem Refrigerasi dan Tata Udara kornponen yang satu berhubungan dengan komponen lainnya, sehinggu apabila ada satu komponen yang tidak berfungsi, maka sistem secara kcseluruhan akan terganggu {tidak berfungsi secara optimal). Dalam menangani suutu masalah Sistem Refrigerasi dan Tata Udara ilem pertama yang harus dicek yaitu kompresor~ karena kompresor merupakan jantung dari sistem refrigerasi. Hasil pengecekan kompresor dalam keadaan baik dengan ampere yang rnasih sesuai dengan spesifikasi, dari kondenser sistem dapat mengeluarkan panas dan evaporator juga dapat menyerap panas, dari pernyataan~pemyataan diatas sistem refrigerasi dalam keadaan baik. Untuk sistem tata udara (mesin pengolah udara), hal pertama yang harus dicek yaitu iaju ali ran volume udara suplai dan laju a! iran udara balik. Laju aliran udara suplai didapat 147 CMH dan uJara balik 112 CMH, nilai lersebut sangatjauh dari perhitungan. Hasil dari perhitungtm analisa psikrometrik didapat laju aJiran udara supplai dan batik yaitu 370 CMH. Dalarn kasus diallls ternyata suplai fan yang terlalu kecil, sehingga diputuskan untuk menganti fan dengan kapsitas yang lebih besar. Setelah penggantian Lajc aliran volume suplai dan balik menjadi 409 dan 359, nilai tersebut tidak bisa ldta bual persis 370 kan::na tidak tersedianya alat pengatur laju aliran volume (volume damper), tetapi pada dasamya nilai diatas sudah masuk dalam spesifikasi yang diinginkan. Setelah kasus laju aliran volume selesai, langkah selanjutnya yaitu pengambllan data, dimana hasilnya temperatur ruang uji tidak tercapai. Dari hasH analisa dengan mellhat grafik perbedaan temperatur refrigeran dan temperatur air dingin (evaporator approach) yang diha.sllkan sangat tinggi, sehingga dapat disimpulkan bahwa evaporator (penukar kalor) tidak dapat berfungsi secant optimal, disamping itu kalu kita melihat tekanan kondenser yang sekitar 280 Psi padahal tekanan tinggi maksimum sistem refrigerasi yang mcnggunakan refrigeran R~22 adalah sekitar 240, ada indikasi bahwa kapasitas kondenser kurnag besar (undersize)."
Depok: Fakultas Teknik Universitas Indonesia, 2001
S37732
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Perubahan cuaca antariksa dapat menimbulkan dampak terhadap lingkungan bumi. Untuk mengantisipasi dan meminimalisasi dampak kerugian yang diakibatkan oleh variabilitas cuaca antariksa ini perlu diberikan informasi, baik berupa peringatan (nowcast)maupun prakiraan (forecast). Untuk dapat memberikan informasi semacam ini, diperlukan pemahaman yang baik pada kopling antara matahari, magnetosfer, ionosfer, dan atmosfer atas. Sebagai pemicu timbulnya variabilitas pada cuaca antariksa, matahari merupakan topik penting yang perlu dipahami dan diteliti untuk mengetahui proses yang terjadi di matahari dan bagaimana energi dan medan magnet ditransfer ke ruang antar planet dan ke ruang angkasa dekat bumi."
520 DIR 10 (1) 2009
Artikel Jurnal  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>