Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 25041 dokumen yang sesuai dengan query
cover
Hadi Sardjono
"Currently, three single junction–type Thermal Voltage Converter (TVC) standard units represent the highest standard of AC (Alternating Current) voltages owned by the Electrical Metrology Laboratory, Research Centre for Metrology—Indonesian Institute of Sciences. The accuracy of the single junction–type TVC is maintained regularly via intercomparison processes using a one-step build-up and build-down method. To reduce the calibration process quantity, three steps of build-up and build-down measurements that refer to the 4 V measurement point of a HOLT production single junction–type TVC were carried out. The dissemination processes with the best measurement accuracy up to 20 ppm were successfully obtained from measurement points between 1 V and 20 V via 4–1V, 4–2V, 4–3V, 4–6V, 4–10V, and 4–20V formations."
Depok: Faculty of Engineering, Universitas Indonesia, 2018
UI-IJTECH 9:1 (2018)
Artikel Jurnal  Universitas Indonesia Library
cover
Gunawan Muhamad Alif
"Pada beberapa peristiwa kebakaran, listrik sering kali dikaitkan sebagai salah satu penyebab utama dari kebakaran. Asap menjadi parameter awal yang mendasari terjadi sebuah peristiwa kebakaran. Keracunan asap adalah salah satu penyebab utama kematian korban kebakaran di dalam ruangan. Asap dapat membunuh manusia dengan melakukan kerusakan pada kombinasi termal, keracunan, dan iritasi paru-paru yang disebabkan oleh reaksi karbon monoksida, hidrogen sianida, dan produk pembakaran lainnya. Peristiwa kebakaran terjadi karena dalam beberapa kasus, banyak detektor asap yang gagal mencapai fungsinya sebagai pendeteksi awal asap karena waktu yang dibutuhkan asap untuk menjangkau sebuah detektor asap pada tempat tertentu ternyata membutuhkan waktu yang cukup lama.
Penelitian ini difokuskan pada kajian eksperimental untuk pendeteksian asap pada kebakaran kabel dengan parameter laju perkembangan luasan asap terhadap tingkat arus listrik dan perubahan waktu dengan pembebanan arus lebih dari titik kritisnya. Penelitian dilakukan dengan skala eksperimen. Frame hasil rekaman akan diukur luasan asapnya dengan menggunakan perangkat lunak ImageJ. Grafik laju perubahan waktu terhadap laju perkembangan luasan asap dengan perubahan tingkatan arus listrik dan kenaikan temperatur didapatkan guna mencari hubungan yang tepat terhadap tingkat bahaya kebakaran.
Hasil dari hubungan tersebut disesuaikan kedalam bahasa pemrograman Adaptive Gaussian Mixture Model dengan melakukan segmentasi obyek latar yang bergerak (foreground) dari latar belakang diam (background) untuk dijadikan parameter dalam penentuan tingkat bahaya asap dalam sistem deteksi asap berbasis pencitraan gambar. Terdapat pula pengujian hasil SEM (Scanning Electron Microscope) terhadap isolator PVC hasil percobaan.

At some events of fire, electricity is often attributed as one of the main causes of fires. Smoke becomes the early parameter that underlie a fire occurs. Smoke is also very dangerous to people. The smoke kills by a combination of thermal damage, poisoning and pulmonary irritation caused by carbon monoxide, hydrogen cyanide and other combustion products. In some cases, a lot of smoke detectors failed to achieve its function as an early detector of smoke because of the time needed to reach smoke detector in certain places took a long time.
This study focused on experimental studies for the detection of smoke in the fire cable with the rapid expansion parameters of smoke on the level of electrical current, temperature rise, and the time on the cable that deliberately be burned by flowing currents more than its critical point. Research is done by the experiment. In this study, the split frames that will each image area of the smoke were measured using ImageJ software. Graph of the rate changes of time to the extent of the smoke with the rapid changes in electrical current levels and an increase in temperature is obtained in order to find the correct relation to level the danger of fire.
Results from the relation are suited into Adaptive Gaussian Mixture Model to segment the moving object (as a foreground) from the background to be used as a parameter in determining the level danger of smoke in the smoke detection using imaging processing. This paper includes SEM (Scanning Electron Microscope) results for the PVC insulator.
"
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50863
UI - Skripsi Open  Universitas Indonesia Library
cover
New York: John Wiley & Sons, 2000
R 543.086 HAN
Buku Referensi  Universitas Indonesia Library
cover
cover
Lintang Hapsari Wilujeng
"

Sumber tegangan listrik merupakan salah satu kebutuhan primer modern di masa sekarang.Sumber tegangan listrik mutlak dibutuhkan untuk menjamin tetap bekerjanya peralatan tersebut.

Namun masalah yang sering dihadapi seringkali adalah sumber-sumber tegangan memiliki nilai yang jauh dibawah level tegangan kerja yang umumnya digunakan pada sistem jaringan listrik perumahan. Untuk mengatasai permasalah sumber tegangan DC tersebut, salah satu cara yang dapat diambil adalah dengan mengimplementasikan sebuah rangkaian pengubah nilai tegangan DC atau DC-DC Converter.

Pada penelitian ini penulis menawarkan rangkaian DC-DC Converter dari tipe terisolasi, yaitu Push-Pull Converter. Pemilihan Push-Pull Converter dilakukan atas beberapa alasan antara lain keandalan, kualitas daya yang dihasilkan, kemudahan untuk diaplikasikan serta yang paling penting adalah ketahanan dari gangguan yang mungkin terjadi.

Sistem dikendalikan dengan menggunakan Pengendali PI dan IP serta diuji kualitasnya dengan menggunakan Diagram Bode.Hasil dari simulasi serta analisa kestabilan menunjukkan bahwa Rangkaian Push-Pull adalah rangkaian yang tahan terhadap gangguan.


Power supply is one of the modern primary needs in the present. Power supply is absolutely necessary to ensure the continuity cooperation of the equipment. However, a problem that often encountered is voltage sources values are far below the working voltage levels that are generally used in residential electrical grid system. To handling the problems of the DC voltage source, one way that can be taken is to implement a DC voltage converter circuit or DC-DC Converter.

In this research, a series of isolated type DC-DC Converters, namely Push-Pull Converter, is being promoted. The Selection of Push-Pull Converter based on reliability and quality of generated power among others, ease of applicability and the most important is the robustness of the interference that may occur.

The system is controlled using a PI controller and the IP also stability tested using Bode plots. The results of simulation and analysis shows that the stability of the Push-Pull circuit is a circuit that is resistant to interference.

"
Fakultas Teknik Universitas Indonesia, 2014
S56862
UI - Skripsi Membership  Universitas Indonesia Library
cover
Heidi Laysandra
"ABSTRAK
Sifat struktur, termal, dan listrik pada temperatur tinggi dari senyawa double perovskite Sr2(Fe,Ti)O6telah dipelajari pada penelitian ini.Sr2(Fe,Ti)O6 disintesis dengan metode solid state reaction. Hasil karakterisasi x-ray diffraction pada temperatur kamar menunjukkan bahwa semua sampel memiliki fase tunggal dan memiliki struktur kristal kubik double perovskite dengan space grup pm3m. Variasi jumlah atom Fe dan Ti mengakibatkan kenaikan parameter kisi dan grainsize. Grainsize yang diperoleh berkisar antara 30 nm sampai dengan 80 nm. Sifat listrik sebagai fungsi temperatur dan frekuensi dikarakterisasi menggunakan RLC-meter dengan metode spektroskopi impedansi. Hasil karakterisasi disajikan dalam Nyquist plot dan Bode plot yang digunakan untuk mengidentifikasi rangkaian ekuivalen dan parameternya. Rangkaian ekuivalen yang diperoleh menunjukkan pengaruh grain dan grain boundary terhadap sifat material. Konduktivitas dc Sr2(Fe,Ti)O6 sebagai fungsi temperatur dijelaskan dengan menggunakan persamaan Arrhenius. Energi aktivasi yang diperoleh dari hubungan konduktivitas dc sebagai fungsi temperatur menunjukkan pengaruh grain dan grain boundary pada sampel. Hal tersebut menunjukkan kemungkinan adanya oxygen vacancy pada material Sr2(Fe,Ti)O6. Kemungkinan ini diperkuat dengan hasil karakterisasi field emission scanning electron microscopy (FESEM) untuk menggambarkan morfologi sampel

ABSTRACT
Structure, thermal, and electrical properties of double perovskite material Sr2(Fe,Ti)O6 at high temperature have been studied. Sr2(Fe,Ti)O6 was synthesized by solid state reaction method. X-ray diffraction characterization at room temperature for all samples show single phase and having cubic double perovskite structure with pm3m space group. The variation of Fe and Ti atoms result an increasing of lattice parameter and grainsize which is found between 30 nm and 80 nm. The electrical properties as a function of temperature and frequency are characterized by using RLC-meter with impedance spectroscopy method. The impedance data are presented in Nyquist and Bode plot resulting in the equivalent circuit and its parameters. The equivalent circuit shows the effect of grain and grain boundary in the electrical properties of materials. DC conductivity of Sr2(Fe,Ti)O6 as a function of temperature was explained by using Arrhenius equation. The value of the activation energy which is evaluated from dc conductivity as a function of temperature shows the effect of grain and grain boundary. The activation energy exhibits of oxygen vacancy in Sr2(Fe,Ti)O6 which is also supported by morphology of Sr2(Fe,Ti)O6 characterized by field emission scanning electron microscopy (FESEM)."
Universitas Indonesia, 2015
S60146
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alif Muhammad Hafizh
"Demam merupakan gejala dari penyakit COVID-19 yang memiliki sensitivitas 54% dan spesifisitas 67% terhadap SARS-CoV-2 sehingga dapat dijadikan acuan untuk mencegah penyebaran penyakit COVID-19. Dua sensor yang paling sering dijadikan termometer infrared adalah MLX90614 dan AMG8833 karena rentang suhu pengukurannya yang tinggi dan akurasinya yang baik. Hasil pengukuran termometer infrared dapat dipengaruhi oleh jarak ukur, suhu ruangan, dan aktivitas fisik pada tubuh manusia. Oleh karena itu, pada skripsi ini penulis merangcang rangkaian thermal camera dengan dua buah sensor infrared dan mengevaluasi kinerja sensor berdasarkan jarak ukur (15, 30, 40, dan 60 cm), suhu ruangan non-AC dan AC (30 dan 26,4 oC), serta aktivitas fisik. Hasil penelitian menunjukkan jarak pengukuran terbaik adalah 15 cm dan besar persentase error rata-rata variabel (EV) yang berbeda dari setiap sensor, yaitu sensor MLX90614 0,560% (15 cm) dan 0,843% (60 cm) sedangkan sensor AMG8833 0,577% (15 cm) dan 1,439% (60 cm). Kemudian MLX90614 mempunyai EV 0,567% (non-AC) dan 0,553% (AC) sedangkan sensor AMG8833 0,868% (non-AC) dan 0,948% (AC). Setelah itu MLX90614 mempunyai EV 0,469% (sebelum aktivitas fisik) dan 0,651% (setelah aktivitas fisik) sedangkan AMG8833 1,259% (sebelum aktivitas fisik) dan 0,558% (setelah aktivitas fisik). Selain tiga variabel uji, casing alat dapat membuat EV sensor AMG8833 kurang dari 1,00% (sebelum dan setelah aktivitas fisik). Akibat adanya nilai EV di atas 1,00 %, penelitian ini dapat dilanjutkan dengan memberikan komponen tambahan yang dapat membuat sensor lebih fokus.

Fever is a symptom of COVID-19 disease which has a sensitivity of 54% and specificity of 67% to SARS-CoV-2 so that it can be used as a reference to prevent the spread of COVID-19 disease. The two sensors that are mostly used as an infrared thermometer are the MLX90614 and AMG8833 sensor because of their high measurement range and good accuracy. The measurement results of an infrared thermometer can be influenced by the measuring distance, room temperature, and physical activity on the human body. Therefore, in this thesis the author designs a thermal camera circuit with two infrared sensors and evaluates the performance of the sensor based on the measuring distance (15, 30, 40, and 60 cm), non-AC and AC room temperature (30 and 26.4 oC), and physical activity. The results showed that the best measurement distance is 15 cm and the average of variable error percentages (EV) are different for each sensor. The MLX90614 sensor has 0.560% (15 cm) and 0.843% (60 cm) EV while the AMG8833 sensor has 0.577% (15 cm) and 1.439% (60 cm) EV. Then the MLX90614 has an EV of 0.567% (non-AC) and 0.553% (AC) while the AMG8833 sensor has 0.868% (non-AC) and 0.948% (AC). After that, MLX90614 has an EV of 0.469% (before physical activity) and 0.651% (after physical activity) while AMG8833 has 1.259% (before physical activity) and 0.558% (after physical activity). In addition to the three test variables, the device enclosure could make the AMG8833 sensor EV less than 1.00% (before and after physical activity). Due to the there are EV values above 1.00%, this research can be continued by adding other components that can make the sensor more focused."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Pamuntjak, Ilya Adzani
"Kenyamanan okupan dalam sebuah ruangan dikaitkan dengan kenyamanan termal, kesehatan, dan kontrol. Maka, kenyamanan termal adalah salah satu hal yang harus dicapaikan oleh sistem pendingin yang tersedia untuk sebuah ruangan indoor. Analisis kenyaman dilakukan dalam auditorium Makara UI Art Center yang menggunakan Chiller berbasis Refrigeran Alami R290. Pemasangan sistem pendingin ini adalah pertama di Indonesia untuk lembaga akademis sebagai kontribusi Universitas Indonesia pada Green Campus Movement. Maka, relevan untuk mengetahui kondisi kenyamanan termal dalam auditorium dalam kondisi pembebanan parsial dan beban kosong. Analisis dilakukan menggunakan temperature logger real-time. Sistem HVAC tidak dapat bereaksi jika diberikan lonjakan beban panas dan kelembaban yang bersifat tiba-tiba, dan sistem memerlukan waktu sekitar 60 menit untuk mengembalikan kelembaban auditorium kembali dalam zona nyaman. Untuk kondisi auditorium penuh, suhu rata-rata adalah 21.750C, dengan kelembaban rata-rata 57.84%, untuk auditorium kosong suhu rata-rata adalah 21.80 C, dan kelembaban rata-rata sebesar 53.14%, yang berarti kategori kenyamanan untuk auditorium adalah Cool Comfort. Perbedaan suhu simulasi dan data lapangan sebesar 12.7% atau +2.630C. Kecepatan udara di atas kepala menurut simulasi adalah 0.2 hingga 0.4 m/s, dimana titik-titik yang mencapai lebih dari 0.25 m/s dapat dikatakan tidak nyaman.

The purpose of this research is to analyze the dry-bulb temperature and humidity about thermal comfort according to SNI 03-6572-2001 standards for the Makara Art Center auditorium at the University of Indonesia using a chiller with the natural refrigerant R290. Thermal comfort is important for the well-being of occupants in the auditorium; therefore, the space must be cooled efficiently to ensure comfort. Data loggers are used to log dry-bulb temperature and humidity data in the auditorium and the results are compared to the SNI-03-6572-2001 indoor thermal comfort standards to create a conclusion of the thermal comfort inside the space. The HVAC system is not capable to detect and mitigate high humidity levels, and requires atleast 60 minutes to return the air humidity to comfortable levels. For full auditorium conditions, the average temperature is 21,750C, with an average humidity of 57.84%, for the auditorium the average temperature is 21.80C, and the average humidity is 53.14%, which means the auditorium can be put in the category of Cool Comfort. The difference in simulation temperature and field data is +12.7% or + 2.630C. The overhead air speed according to the simulation is 0.2 to 0.4 m / s, which means locations reaching more than 0.25 m/s can be considered uncomfortable."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Universitas Indonesia, 1993
S27939
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abdulkareem S
"This paper reports on the investigation of thermal properties of Kapok, Coconut fibre and Sugarcane bagasse composite materials using molasses as a binder. The composite materials were moulded into 12 cylindrical samples using Kapok, Bagasse, Coconut fibre, Kapok and Bagasse in the ratios of (70:30; 50:50 and 30:70), Kapok and Coconut fibre in the ratios of (70:30; 50:50 and 30:70), as well as a combination of Kapok, Bagasse and Coconut fibre in ratios of (50:10:40; 50:40:10 and 50:30:20). The sample size is a 60mm diameter with 10mm – 22mm thickness compressed at a constant load of 180N using a Budenberg compression machine. Thermal conductivity and diffusivity tests were carried out using thermocouples and the results were read out on a Digital Multimeter MY64 (Model: MBEB094816), while a Digital fluke K/J thermocouple meter PRD-011 (S/NO 6835050) was used to obtain the temperature measurement for diffusivity. It was observed that of all the twelve samples moulded, Bagasse, Kapok plus Bagasse (50:50), Kapok plus Coconut fibre (50:50) and Kapok plus Bagasse plus Coconut fibre (50:40:10) has the lowest thermal conductivity of 0.0074, 0.0106, 0.0132, and 0.0127 W/(m-K) respectively and the highest thermal resistivity. In this regard, Bagasse has the lowest thermal conductivity followed by Kapok plus Bagasse (50:50), Kapok plus Bagasse plus Coconut fibre (50:40:10) and Kapok plus Coconut fibre (50:50)."
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:6 (2016)
Artikel Jurnal  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>