Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 6216 dokumen yang sesuai dengan query
cover
Ferhat Aziz
"Synthesis and Monte Carlo simulation of improved concrete composites as x-ray/gamma ray shielding materials were performed. Samples of shieldings were synthesized using the base materials of Portland-type cement concrete with fillers of alloy steel, Co, Mn, and Cr, mixed separately as additives. The samples were characterized using Scanning Electron Microscopy-Energy Dispersive X-ray Spectrometry (SEM-EDS) to determine the constituent elements quantitatively. Linear attenuation coefficients of the samples were measured in the experiments and also simulated using Monte Carlo transport code MCNP5 in order to evaluate their shielding performance. The results of the experimentation and computer simulation reveal concrete with alloy steel added as having the best shielding properties, although concrete with other fillers added also exhibited enhanced shielding performance. It was demonstrated that 6.06 w% of fillers enhanced the x-ray/gamma ray shielding capability of ordinary concrete composites by improving their attenuation coefficient values by 40–60%."
Depok: Faculty of Engineering, Universitas Indonesia, 2018
UI-IJTECH 9:4 (2018)
Artikel Jurnal  Universitas Indonesia Library
cover
Yessie Widya Sari
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2005
T39805
UI - Tesis Membership  Universitas Indonesia Library
cover
Dedi Priadi
"Telah dilakukan penelitian tentang analisa tegangan sisa baja rol-temps. Pengujian tegangan sisa dilakukan dengan teknik difraksi sinar- dimana proses pengerolan ini merupakan proses rol-temps. Dalam proses desain dan produksi suatu produk sering terjadi kegagalan dari material tersebut baik sebelum dan saat digunakan. Hal ini karena adanya tegangan sisa yang tidak terhitungkan sebelumnya. Namun tegangan sisa ini tidak selalu merugikan, karena tergantung arahnya beban yang dikenakan. Secara umum adanya tegangan sisa ini lebih sering merugikan. Hasil penelitian menunjukkan bahwa besarnya tegangan sisa juga dipengaruhi perubahan struktur akibat adanya transformasi fasa, walaupun besarnya tegangan sisa akibat rolling pra-tempa relatif kecil Dengan panas anil 700 °C dan waktu tahan 25 menit terlihat penurunan tegangan sisa Puncak-puncak difraksi yang dilaku rol lebih lebar daripada yang tidak dirol. Hal ini menunjukkan regangannya tidak homogen. Dari analisa penghalusan GSAS dapat menggambarkan ketidak homogenan regangan."
Depok: Fakultas Teknik Universitas Indonesia, 2002
LP-Pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
cover
Yohana
"Pemantauan dosis pada pekerja radiasi diperlukan untuk memastikan dosis yang diterima tidak melebihi batas aman yang telah ditetapkan oleh BAPETEN. Dosimeter Termoluminesensi (TLD) seringkali digunakan untuk pemantauan dosis pekerja radiasi. Sebelum digunakan, TLD perlu dikalibrasi dengan suatu sumber radiasi untuk memastikan TLD dapat memberikan hasil pengukuran yang akurat. Salah satu faktor yang mempengaruhi akurasi pengukuran TLD adalah energi. Ketergantungan respons TLD terhadap energi menyebabkan pemilihan sumber radiasi yang tepat untuk kalibrasi TLD perlu diperhatikan. Penelitian ini mengevaluasi respons TLD LiF:Mg,Ti terkalibrasi sumber 137Cs yang digunakan pada rentang energi sinar-X diagnostik menggunakan simulasi Monte Carlo. Evaluasi respons TLD terhadap energi dilakukan menggunakan perhitungan spektrum energi dengan variasi tegangan tabung 60 kV sampai 100 kV, dengan interval 10 kV, dan arus tabung 20 mAs. Hasil penelitian menunjukkan bahwa perhitungan spektrum energi dengan simulasi Monte Carlo dapat digunakan untuk mengestimasi nilai dosis serap dan mengevaluasi respons TLD terhadap energi dengan hasil respons relatif terhadap sumber 137Cs yang diperoleh pada penelitian ini berada pada rentang 1,33 sampai 1,37. Hasil ini menunjukkan bahwa penggunaan sumber 137Cs untuk kalibrasi TLD merupakan pilihan yang kurang tepat dan diperlukan penggunaan sumber radiasi lain untuk mengkalibrasi TLD yang digunakan pada rentang energi sinar-X diagnostik.

Dose monitoring for radiation workers is essential to ensure that the received dose does not exceed the safety limits set by BAPETEN. Thermoluminescent Dosimeters (TLDs) are commonly used for personal dose monitoring. Before use, TLD must be calibrated with a radiation source to guarantee accurate measurement results. Accurate measurements using TLD are essential for dose monitoring. The energy of the radiation is one of the factors affecting the accuracy of TLD measurement. Because TLD response depends on energy, choosing the correct radiation source for calibration is important. This study evaluates the response of LiF:Mg,Ti TLD calibrated with 137Cs source used in the diagnostic X-ray energies using Monte Carlo simulations. The evaluation of TLD response was determined using energy spectrum calculations at tube voltage variations from 60 kV to 100 kV, in 10 kV increments, and a tube current of 20 mAs. The results indicate that energy spectrum calculations can be used to estimate absorbed dose and evaluate TLD response to energy. The relative response to the 137Cs source obtained in this study was between 1.33 and 1.37. These results show that using 137Cs source for calibration is not the optimal choice, and an alternative radiation source is needed for calibrating TLD used in the diagnostic X-ray energy range."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Agarwal, B.K.
Berlin: Springer-Verlag, 1991
543.62 AGA x
Buku Teks SO  Universitas Indonesia Library
cover
Jenkins, Ron
New York : John Wiley & Sons, 1988
543.57 JEN x
Buku Teks SO  Universitas Indonesia Library
cover
H. Widyatmoko
"X-ray Fuorescence spectrometry semakin sering digunakan dalam bidang geokimia. X-Fuorescence spectrometry dikategorikan menjadi dua yakni ? WDXRF (wavelenght ? dispersive X- ray fluorescence spectrometer) dan EDXRF (energy-dispersive X ? ray fluorescence spectrometer). WDXRF dapat berbentuk sebagai sequential spectrometer, simultaneous spectrometer atau kelebihan dari kelebihan keduanya dikombinasikan menjadi satu perangkat yakni hibrid instrument. Masing-masing instrumen XFA mempunyai karakteristika dan kekhusussan dalam penggunaan. Penelitian ini menggunakan sequential spectrometer PW 1450 untuk menganalisis major, minor and trace elements dalam sample. Untuk mengkalibrasi PW 1450 digunakan 30 standar internasional dan 66 standar dari Institut für Mineralogie der Uni. Köln, Germany, yang telah diketahui konsentrasi masing-masing unsurnya. Interelement dan matrix effects dihilangkan dengan cara mencocokkan matrix pada sample dan standar, pengenceran, penambahan konsentrasi unsur-unsur yang dimaksud dalam jumlah tertentu, dan koreksi secara matematik pada saat analisis sedang berlangsung. Ujicoba pada dua sampel dan deskripsi statistik dengan standard deviation dan coefficient of variant menunjukkan bahwa XFA cukup akurat untuk beberapa unsur terutama unsur mayor, tetapi untuk Mg, Ca, K, Na, P, S, Co, Rb, Zn, Ni, Ba, Pb sensivitasnya masih lebih rendah dibandingkan dengan Atomic Absorpsion Spectrometry (AAS), Flame Emission Spectrometer (FES), Inductively Coupled Plasma (ICP) dan photometer.

Wavelenght?Dispersive X-Ray Flourescence Accuration. X-Fuorescence spectrometry is a method, which is increasingly applied in the geochemical analysis. X-Fuorescence spectrometry is classified under two categories ? WDXRF (wavelenght ? dispersive X-ray fluorescence spectrometer) and EDXRF (energy-dispersive X ? ray fluorescence spectrometer). WDXRF can be configured as a sequential spectrometer , a simultaneous spectrometer or a hibrid instrument, which combines the advantages of the simultaneous and sequential spectrometers into one instrument. Each instrument is different in some characteristics, and each has applications for which it is specifically suited. In this investigation sequential spectrometer PW 1450 was used to analyze the major, minor and trace elements in the samples. The standards used in calibrating the PW 1450 for the analysis of all samples are materials of known composition (30 internatioanal standards and 66 standards from Institut für Mineralogie der Uni. Köln, Germany). Interelement and matrix effects are treated by matrix matching of samples and standards, dilution, preconcentration of the element of interest, and mathematic corrections during data analysis. The examination of two samples and the statistic description using standard deviation and coefficient of variant show that the XFA is accurate enaugh for many elements, especially for the major elements, but for Mg, Ca, K, Na, P, S, Co, Rb, Zn, Ni, Ba, Pb in comparison with Atomic Absorpsion Spectrometry (AAS), Flame Emission Spectrometer (FES), Inductively Coupled Plasma (ICP) and photometer it is less sensitive. It is posible to devaluate the errors by using coefficient of variant and standard deviation."
Depok: Lembaga Penelitian Universitas Indonesia, 2004
AJ-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
Bacon, G.E.
Oxford: Pergamon Press, 1966
548.83 BAC x
Buku Teks  Universitas Indonesia Library
cover
Sembiring, Simon
"Pada penelitian ini, mullite yang disintesis dari aluminum nitrat hidrat [(Al(NO3)3.9H2O] dan sol silika sekam padi dikenakan pada perlakuan sintering dengan suhu 900, 1000, 1100, 1200, dan 1300°C, kemudian dikarakterisasi dengan difraksi sinar-x (XRD) dilanjutkan dengan penghalusan menggunakan metode Rietveld, dan analisis termal diferensial (DTA). Hasil penelitian menunjukkan bahwa dalam sampel yang disintering pada suhu 900°C, tidak ditemukan fasa mullite, tetapi fasa kristobalit dan alumina terdeteksi dengan jelas. Pembentukan mullite baru terjadi pada suhu 1000°C dan bertumbuh dengan peningkatan suhu ditandai dengan kenaikan persen berat (wt%) dari 62,62 menjadi 92,29%, disertai penurunan persen berat kristobalit dari 22,42 menjadi 1,25% dan penurunan persen berat alumina dari 77,58 menjadi 6,46%. Hasil penghalusan menunjukkan korelasi yang baik antara unit sel hasil perhitungan dan hasil pengamatan, dengan dimensi unit sel adalah a = 7,545 nm, b = 7,689 nm dan c = 2,884 nm untuk mullite, a = b = 0,5531 nm, dan c = 0,6923 nm untuk kristobalit, dan a = b = 0,5026 nm, dan c = 1,2808 nm untuk alumina. Hasil analisis dengan DTA menunjukkan bahwa dalam sampel yang tidak disintering, hanya terdapat alumina dan silika, sementara dalam sampel yang disintering terdapat mullite, alumina, dan kristobalit.

In this study, mullite synthesized from aluminum nitrate hydrate [(Al(NO3)3.9H2O] and silica sol from rice husk was subjected to sintering treatment at temperatures of 900, 1000, 1100, 1200, and 1300°C, and characterized using x-ray diffraction (XRD), followed by Rietveld refinement, and differential thermal analysis (DTA). The results indicated that in the sample sintered at 900°C, no mullite phase was identified, but crystoballite and alumina were well detected. The formation of mullite started at temperature of 1000°C and continued to grow at higher temperatures, resulted in increased weight percentage (wt%) from 62.62 to 92.29%, while crystoballite and alumina decreased from 22.42 to 1.25% and from 77.58 to 6.46 % respectively. A good correlation was found between the calculated and observed unit cells. For mullite phase, the unit cell dimensions are a = 7.545 nm, b =.689 nm and c = 2.884 nm, for crystoballite a =b = 0.5531 nm and c = 0.6923 nm, and for alumina a = b = 0.5026 nm, and c = 1.2808 nm. The DTA analyses revealed that in the untreated sample, only alumina and silica were detected, while in the sintered samples we found the existence of mullite, alumina, and crystoballite."
Depok: Direktorat Riset dan Pengabdian Masyarakat UI;Universitas Lampung. Fakultas Matematika dan Ilmu Pengetahuan Alam, 2012
J-pdf
Artikel Jurnal  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>