Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 127301 dokumen yang sesuai dengan query
cover
Sri Wulandari
"Dalam menganalisis suatu pondasi tiang pancang yang menerima beban lateral, di samping memperhitungkan daya dukung tiang harus juga memperhatikan aspek geotekniknya, yaitu sifat-sifat dan perilaku tanah yang menerima beban lateral. Penelitian dilakukan untuk mengetahui defleksi dan momen lentur grup tiang di tanah lempung ketika menerima beban horisontal statis pada kepala tiang yang kondisinya terjepit (fixed head). Lokasi penelitian diambil dari dua buah gedung di daerah DKI Jakarta, yaitu Gedung Kondominium Tanjung Duren dan Gedung IKPT. Kedua bangunan tersebut didesain dengan menggunakan tiang pancang, di mana pada Kondominium Tanjung Duren tiang dikategorikan sebagai tiang pendek, dan pada Gedung IKPT tiang dikategorikan tiang panjang.
Penelitian defleksi tiang dilakukan dengan menggunakan teori elastis Poulos dan program Florida Pier. Sedangkan momen lentur diteliti dengan menggunakan teori elastis Poulos, program Florida Pier, dan formulasi Ilyas. Beban lateral diberikan sebanyak lima kali dengan beban pertama didasarkan pada hasil perhitungan kapasitas lateral hang masing-masing proyek. Besarnya beban lateral setiap hasil perhitungan dari Kondominium adalah 6 ton. Sedangkan dan gedung IKPT adalah 7 ton per tiang. Teori elastis Poulos tidak memperhitungkan shadowing effect karena nilai defleksi dan momen lentur tiang lead dan rear adalah sama. Sedangkan menurut program Florida Pier, defleksi tiang rear lebih besar daripada tiang lead, dan momen lentur tiang lead lebih besar daripada tiang rear. Shadowing effect juga terlihat dalam formulasi liyas, karena besaran momen lentur tiang lead kedua grup bangunan mengecil dibandingkan dengan tiang tunggal. Semakin banyak jumlah tiang daiam grup, semakin kecil nilai momen lentur yang ditahan setiap tiang. Kurva defleksi-beban lateral dari teori elastis Poulos dan program Florida Pier berbentuk tinier, Begitu juga dengan kurva momen lentur-beban lateral teori elastis Poulos, Florida Pier, dan rumus llyas berbentuk linier. Nilai defleksi tiang pendek teori elastis lebih kecil dari Florida Pier, sedangkan pada tiang panjang teori elatis lebih besar dari Florida Pier. Momen lentur formulasi Ilyas adalah nilai momen terbesar, diikuti Florida Pier, dan teori elastis Poulos."
Depok: Fakultas Teknik Universitas Indonesia, 2004
T14983
UI - Tesis Membership  Universitas Indonesia Library
cover
Tommy Ilyas
"Penelitian dilakukan dengan menggunakan alat centrifuge mengingat keandalannya dapat menghasilkan karakteristik tanah menjadi kondisi yang sesuai dengan karakteristik struktur tanah sebenarnya dilapangan. Penulis melakukan penelitian di 'Centre for soft ground Engineering National Universiy of Singapure' yang memiliki alat centrifuge satu-satunya di Asia Tenggara.
Penelitian grup tiang dilapisan pasir akibat pembebanan lateral dengan menggunakan alat centrifuge telah banyak dilakukan, namum studi untuk memahami kinerja dari grup tiang yang dibebani beban lateral pada lapisan lempung masih sangat terbatas."
Depok: Fakultas Teknik Universitas Indonesia, 2002
D153
UI - Disertasi Membership  Universitas Indonesia Library
cover
Tommy Ilyas
"ABSTRAK
Penelitian dilakukan dengan menggunakan alat centrifuge mengingat keandalannya dapat menghasilkan karakteristik tanah menjadi kondisi yang sesuai dengan karakteristik struktur tanah sebenarnya dilapangan. Penulis melakukan penelitian di ?Centre for soft ground Engineering National University of Singapore? yang memiliki alat centrifuge satu-satunya di Asia Tenggara.
Penelitian grup tiang dilapisan pasir akibat pembebanan lateral dengan menggunakan alat centrifuge telah banyak dilakukan, namun studi untuk memahami kinerja dari grup tiang yang dibebani beban lateral pada lapisan lempung masih sangat terbatas.
Untuk mencapai tujuan penelitian ini sebuah seri percobaan yang komprehensif dilakukan untuk menguji perilaku tiang yang dibebani beban lateral statis dilapisan lempung normally consolidated (NC) dan over consolidated (OC). Konfigurasi grup tiang terdiri dari tiang tunggal, 2- grup tiang, 3x3 dan 4x4 grup tiang. Model tiang adalah ?square hollow alliununium? yang diberi instrumentasi strain gauges untuk memonitor respon momen lentur sepanjang tiang ketika ini beban lateral dilakukan. Untuk mengikat tiang menjadi grup digunakan ?pile cap? dari alumunium yang masif. Pile cap berada diatas permukaan tanah dan dapat berotasi ketika menerima beban lateral. Panjang tiang dalam tanah adalah 210 mm (14.7 m pada skala prototip ketika dites pada 70-g). Seri tes dilakukan pada grup tiang dengan jarak antar tiang 3 kali lebar tiang (3D). Tes dengan jarak antar tiang SD dilakukan pada grup tiang 2x3 dan 3x3 untuk melihat pengaruh efisiensi dan kapasitas grup tiang terhadap pembesaran jarak antar tiang.
Hasil pengujian dalam bentuk profil momen lentur, reaksi tanah (subgrade reaction) dan defleksi lateral dilapisan lempung NC dan OC dipresentasikan dengan rinci dalam disertasi ini. Pengaruh ?shadowing? (pengaruh tiang yang dimuka terhadap tiang yang dibelakangnya) mengakibatkan momen lentur maksimum yang terjadi pada individual tiang makin kecil jika jumlah tiang dalam grup membesar. Tiang lead (front) merupakan tiang yang menahan momen lentur terbesar dalam grup tiang. Perpindahan (displacement) pada individual tiang dalam grup akan makin besar jika ukuran grup tiang membesar. Efisiensi grup tiang mengecil jika jumlah tiang dalam grup, dengan jarak antar tiang 3D, membesar. Bila jarak antar tiang membesar meniadi SD maka efisiensi grup tiang mendekati l00%. P-multiplier untuk grup tiang dilapisan lempung OC lebih besar dari p-multiplier grup tiang dilapisan lemplmg NC. Perbandingan hasil observasi dengan teori elastis yang dikembangkan oleh Poulos sangat berbeda terhadap kapasitas lateral maupun momen lentur dari individual tiang dalam grup. Kesesuaian yang baik diperoleh antara hasil observasi dan prediksi yang menggunakan program finite element tiga dimensi FLPIER serta metoda iterative pada grup tiang dilapisan NC dan OC."
Depok: Fakultas Teknik Universitas Indonesia, 2002
D1208
UI - Disertasi Membership  Universitas Indonesia Library
cover
Tommy Ilyas
"Sebuah seri percobaan dengan alat centrifuge dilaksanakan dilapisan lempung normally consolidated (NC) untuk mengetahui karakteristik bending momen dari grup tiang akibat pembebanan lateral statis. Grup tiang mempunyai denah yang simetris dengan konfigurasi tiang tunggal,2x1 , 2x2,3x3, 4x4 grup tiang dengan jarak antar tiang 3 kali lebar tiang. Pile cap dari bahan aluminium yang masif yang terletak diatas permukanaan tanah digunakan untuk mengikat tiang dalam grup. Profil bending momen untuk tiang grup dipersentasikan dengan rinci. Rumus emperis untuk grup tiang di lapisan NC disajikan untuk merancang kapasitas bending momen yang terjadi pada kedalaman tiang dalam tanah"
Depok: Fakultas Teknik Universitas Indonesia, 2002
JUTE-XVI-1-Mar2002-1
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Muhammad Reza Imansyah
"Kemungkinan kejadian kegempaan di Indonesia sangat tinggi sehingga diperlukan struktur fondasi yang mampu menahan beban gempa dengan baik. Oleh karena itu, pada penelitian ini dilakukan studi pemodelan fondasi grup tiang dengan memasukkan pembebanan lateral sebagai simulasi beban gempa. Pemodelan ini memperhatikan keluaran berupa interaksi antara tiang fondasi dengan tanah pada tanah lempung. Selain itu, keluaran yang diperhatikan adalah seismic behavior berupa daktilitas dan kejadian sendi plastis yang dialami oleh tiang fondasi. Studi pemodelan dilakukan dengan mengacu pada penelitian Yuwono et al. (2020), di mana model fondasi grup tiang dibuat pada tanah lempung dengan variasi kuat geser undrained tanah 20 kPa, 40 kPa, 60 kPa, 80 kPa, dan 100 kPa. Pada penelitian ini, keluaran-keluaran yang diperhatikan mengikutsertakan pengaruh dari variasi kuat geser undrained tanah tersebut. Model tanah dan tiang dimodelkan dalam pendekatan nonlinier P-y dari Beam-on-Nonlinear-Winkler-Foundation (BNWF) melalui aplikasi OpenSees. Melalui pemodelan tersebut, dilakukan validasi penelitian terhadap model fondasi penelitian Yuwono et al. (2020)berdasarkan kurva pushover yang terbentuk. Dari penelitian ini, semakin besarnya nilai kuat geser undrained tanah maka kecenderungan nilai daktilitas lendutan semakin besar. Lalu, semakin besarnya nilai kuat geser undrained tanah juga mempercepat terjadinya sendi plastis pertama dan lebih memungkinan menghasilkan kejadian sendi plastis kedua. Nilai kuat geser undrained tanah yang semakin besar juga meningkatkan nilai gaya dalam momen bending dan aksial pada tiang-tiang fondasi. Pada penelitian ini, tidak terjadi kegagalan geser sama sekali pada seluruh tiang namun terjadi kegagalan lentur untuk lead pile pada tanah dengan kuat geser undrained tanah 100 kPa. Selain itu, terbentuk momen guling untuk fondasi grup tiang pada tanah dengan kuat geser undrained tanah 20 kPa dan 100 kPa. Adapun secara performa, nilai P-Multiplier yang semakin besar membuat peran tiang menjadi lebih besar pada sistem fondasi grup tiang dan semakin besarnya nilai kuat geser undrained tanah akan cenderung meningkatkan nilai faktor efisiensi grup.

The possibility of earthquakes in Indonesia is very high, so a foundation structure that can withstand earthquake loads is adequately needed. Therefore, in this study, a pile group foundation modeling study was conducted by including lateral loading as a simulation of earthquake loads. This model pays attention to the output in the interactions between the foundation piles and the soil on clay soil. In addition, the output considered is seismic behavior in the form of ductility and the occurrence of plastic hinges experienced by the foundation piles. The modeling study was conducted with reference to the research of Yuwono et al. (2020), in which the pile group foundation model is made on clay soils with variations in the undrained shear strength of the soil 20 kPa, 40 kPa, 60 kPa, 80 kPa, and 100 kPa. In this study, the observed outputs include the effects of variations in the undrained shear strength of the soil. The soil and pile models were modeled in the P-y nonlinear approximation of the Beam-on-Nonlinear-Winkler-Foundation (BNWF) via the OpenSees application. Through this modeling, research validation was carried out on the research foundation model of Yuwono et al. (2020) based on the pushover curve formed. From this study, the greater the value of the undrained shear strength of the soil, the greater the tendency of the deflection ductility value. Then, the greater the value of the undrained shear strength of the soil also accelerates the occurrence of the first plastic hinge and is more likely to produce a second plastic hinge occurrence. The greater the value of the soil's undrained shear strength also increases the force's value in bending and axial moments on the foundation piles. In this study, there was no shear failure on the entire pile but flexural failure for the lead pile on the soil with an undrained shear strength of 100 kPa. In addition, the overturning moment is formed for pile group foundations on soils with undrained shear strengths of 20 kPa and 100 kPa. As for performance, the larger the P-Multiplier value, the greater the role of the pile in the pile group foundation system, and the greater the value of the undrained shear strength of the soil will tend to increase the value of the group efficiency factor."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fardan Fikriansyah
"Metode  kerja  untuk  memancang  tiang  pancang  baru  pada  bangunan  eksisting 
dengan  kondisi  adanya  tiang  pancang  eksisting  sering  kali  dilakukan  untuk 
mempercepat periode konstruksi. Distribusi beban dan perpindahan tiang pancang 
baru perlu diselidiki lebih lanjut akibat efek dari adanya tiang pancang eksisting. 
Metode transfer beban lateral (p-y curve) digunakan untuk menganalisis beban dan 
perpindahan  tiang  pancang  menggunakan  analisis  elemen  hingga  tiga  dimensi. 
Tiang pancang baru dan eksisting yang digunakan adalah spun pile berdiameter 0.6 
meter dengan ketebalan 0.1 meter, kedalaman tiang 17 meter dan jarak antar tiang 
pancang baru dan eksisting adalah 1 meter. Besar beban horizontal yang diberikan 
sebesar  150  kN  pada  kepala  tiang  yang  berada  1  meter  di  atas  muka  tanah. 
Penelitian ini dilakukan pada jenis tanah lempung dengan model konstitutif Mohr 
Coulomb  dan  Modified  Cam  Clay.  Hasil  analisis  elemen  hingga  tiga  dimensi 
menunjukkan  bahwa  tahanan  lateral  tanah  tiang  pancang  baru  meningkat  pada 
kepala  tiang  hingga  kedalaman  tanah  di  sekitar  permukaan  akibat  adanya  tiang 
pancang eksisting. 

The method of driving new piles in existing buildings using existing piles is often 
used to speed up the construction period. The load distribution and displacement of 
the new pile need to be investigated further because of the influence of the existing 
pile. The lateral load displacement method (p-y curve) is used to analyze the load 
and displacement of the pile using three-dimensional finite element analysis. The 
new and existing piles used are piles with a diameter of 0.6 meters, a thickness of 
0.1 meters, a pile depth of 17 meters, and the distance between the new piles and 
the existing piles is 1 meter. The horizontal load applied is 150 kN on the pile head 
which is 1 meter above the ground surface. This research was carried out on clay 
with the Mohr Coulomb dan Modified Cam Clay constitutive model. The results of 
three-dimensional finite element analysis show that the soil lateral resistance of the 
new pile increases at the pile head to the depth of the soil around the surface due to 
the presence of the existing pile. 
"
Depok: Fakultas Teknik Universitas Indonesia, 2024
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Hardjanto
"Pile Cap yang mempunyai fungsi untuk menyebarkan beban dari komponen tekan maupun tarik ke kelompok tiang, sehingga beban terbagi secara merata pada setiap tiang anggota. Pile cap juga mengakomodasi penyimpangan posisi yang diakibatkan oleh beban horisontal. Rekahan (crack) bisa terjadi pada pertemuan pilecap dan tiang pancang dikarenakan momen-momen lentur akibat beban lateral pada kondisi sambungan jepit (fixed) maupun sendi (pinned).
Penelitian ini diawali dengan studi hasil penelitian Kim, Zhang mengenai tahanan lateral pile cap pada grup tiang. Kemudian dilakukan pemodelan pile cap dengan dua macam ketebalan, dengan mengambil 2D dan 3.5D, dimana D adalah diameter tiang pancang. Selain itu diambil juga kedudukan tiang pancang, diatas muka tanah dan dibawah permukaan tanah. Pemodelan dan analisis dilakukan dengan menggunakan software FLPier. Kemudian dilakukan perbandingan hasil analisis pile cap pada ketebalan 2D dan 3.5D.
Defleksi yang terjadi pada ketebalan pile cap 2D pada lead pile, ditunjukkan lebih besar daripada lead pile dengan ketebalan 3.5D. Momen pile cap pada lead pile selalu lebih besar daripada posisi rear, balk pada ketebalan pile cap 2D maupun 3.5D. Pada ketebalan pile cap 3.5 D, momen yang terjadi lebih besar dari momen yang terjadi pada ketebalan pile cap 2D.
"
Depok: Fakultas Teknik Universitas Indonesia, 2004
T14972
UI - Tesis Membership  Universitas Indonesia Library
cover
Budy Purnomo Wasisso
"Pembebanan suatu struktur dibagi atas dua bagian besar yakni pembebanan statik dan pembebanan dinamik. Dalam kenyataannya, pembebanan dinamik sering menimbulkan permasalahan struktur yang lebih kompleks dan lebih banyak menimbulkan dampak negatifbagi kekuatan struktur daripada pembebanan statik, sehingga pengetahuan yang baik mengenai perilaku struktur akibat pembebanan dinamik sangat diperlukan dalam perencanaan struktur maupun pemecahan masalah perilaku dinamik dari struktur yang ada.
Perilaku dinamik suatu struktur dapat dijelaskan dengan menentukan parameter-parameter modus getamya yang terdiri dari frekuensi alami, redaman viskus dan bentuk modus getar {mode shape), dimana ketiganya dapat ditentukan secara analitis (teoritis) maupun secara percobaan (eksperimen). Pada skripsi ini akan dilakukan suatu percobaan untuk mendapatkan frekuensi alami dan respons struktur pada satu model pondasi riang baja sederhana.
Benda uji yang digunakan dalam percobaan berupa tiang baja yang tidak pejal dan berdimensi bujur sangkar dengan perletakan sendi serta beberapa pegas yang dipasang di kanan kirinya. Tiang baja, perletakan dan pegas-pegasnya ini diletakkan pada suatu kerangka baja yang diusahakan sedemikian rupa sehingga apabila diberikan gaya luar maka benda uji hanya dapat bergerak (bergetar) dalam arah dua dimensi.
Pada percobaan ini, benda uji tersebut diberi gaya impuls dengan palu dalam arah lateral sehingga menghasilkan suatu percepatan yang akan diukur dengan menggunakan accelerometer. Dari percepatan struktur yang telah dihasilkan, maka dapat dicari besarnya frekuensi alami dan respons perpindahan. Langkah berikutnya adalah menentukan frekuensi alami dan respons perpindahan secara numerik menggunakan program GT-STRUDL dengan data masukan adalah besarnya gaya palu pada percobaan dan sifat material benda uji baja beserta dimensinya.
Metode numerik yang digunakan adalah metode superposisi modal, yaitu untuk mendapatkan eigenvalues dan eigenvectors yang selanjutnya digunakan untuk mendapatkan respons perpindahannya. Sebagai langkah akhir adalah membandingkan hasil frekuensi alami maupun perpindahan yang dihasilkan dari percobaan dengan hasil yang diperoleh secara numerik."
Depok: Fakultas Teknik Universitas Indonesia, 1999
S34855
UI - Skripsi Membership  Universitas Indonesia Library
cover
Budi Susilo Soepandji
"ABSTRAK
Dermaga tempat bertambat kapal merupakan konstruksi yang harus handal dalam menopang gaya axial dan lateral yang cukup besar untuk kemudian diteruskan struktur balok ke pondasi. Struktur balok beton di Pelabuhan mengalami kerusakan akibat mengelupasnya beton yang berakibat proses korosi pada besi beton yang berakibat dapat menurunkan kekuatan struktur-beton. Pondasi tiang pipa baja dipilih untuk menumpu struktur dermaga, dengan kedalaman tiang 56.00 meter yang tcrjepit lapisan tanah lunak sampai kedalaman 38.00 meter LWS, dan lapisan lempung kaku {stiff} sampai kedalaman yang bervariasi dari 38.00 meter sampai 56.00 meter atau 62.00 meter dibawah LWS. Untuk reperasi dermaga tersebut diperlukan penelitian dan perencanaan perbaikan dermaga beton & sistem pondasinya dengan beberapa metoda analisa struktur dan geoteknik."
Fakultas Teknik Universitas Indonesia, 1994
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>