Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 132609 dokumen yang sesuai dengan query
cover
cover
Aziz Khan Jahja
"Penentuan Waktu Loncatan Hopping dan Konsentrasi Pembawa Muatan Listrik pada Konduktor Superionik Rb4Cu16l7+xCl ,3,x Konduktor superionik tidak-stoikiometrik RbjCui6l7

The Determination of Hopping Rates and Carrier Concentrations in Rb4Cu,6l7+xCli3.x Superionic Conductor Non-stoichiometric superionic conductor RbJCui617+xCi3_x has been synthesized by solid state reaction. The frequency response of frequency dependent conductivity have been measured by a.c. complex impedance bridge methods in the temperature range 200-460 K. The a.c. conductivity of superionic materials takes the form, a=<(0) + Aof. The carrier hopping rate a>p is obtained from the new expression a(0)=Ao)p, and the carrier concentration is estimated from a(0). The contribution of creation and migration terms to the activation energy from conduction may be determined from the thermal activation of a(0) and a^ and the corresponding entropy terms quantified. In this paper , conductivity data is analyzed, to obtain the carrier concentration and hopping rates of Rb4Cui6I7x+5l13-2."
1999
JIRM-1-2-Agust1999-14
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Nindya Ariyanti
"Adanya perkembangan teknologi bahan, khususnya untuk aplikasi kabel penghantar listrik menyebabkan terjadinya pergeseran terhadap bahan yang digunakan untuk konduktor listrik yang sebelumnya menggunakan tembaga dan sekarang mulai digeser oleh paduan Aluminium. Pergeseran tersebut disebabkan oleh paduan aluminium mempunyai keunggulan dibandingkan dengan kawat tembaga antara lain; mempunyai berat jenis lebih rendah, proses pembuatan relatif lebih mudah, serta harga relatif lebih murah. Bahan konduktor tidak selalu berada pada lingkungan yang ideal.
Isu pencemaran udara tidak luput dari kualitas bahan konduktor di lapangan, salah satu contohnya adalah hujan asam. Hujan asam dapat mempengaruhi kualitas bahan konduktor. Hujan asam dapat membuat korosi dan menurunkan konduktivitas. Penelitian ini bertujuan untuk mendapatkan penyebab menurunnya konduktivitas bahan konduktor aluminium dan paduan aluminium dengan melakukan pengujian konduktor yang terkontaminasi oleh larutan H2SO4. Bahan konduktor yang digunakan adalah aluminium murni, AlZrCe+Mg 1%+ Al2O31% dan AlZrCe + Al2O31%.
Penelitian dilakukan dengan merendam bahan konduktor didalam larutan H2SO4 1%, 3%, dan 5% selama 7 hari dan data diambil pada hari pertama, kedua, ketiga dan ketujuh. Konduktivitas hari pertama dan ketujuh mengalami penurunan konduktivitas akibat larutnya butir butir aluminium dan paduan aluminium. kondisi awal konduktivitas aluminium murni IACS pada hari ketujuh atau 7x24 jam terjadi penurunan menjadi 57,584% IACS pada larutan 1%, 56,486% IACS pada larutan 3% dan 55,632% IACS pada larutan 5%. Hal ini dapat terjadi karena elektron bebas yang melewati kisi-kisi kristal yang terdistorsi, maka elektron-elektron akan dibelokkan sehingga jarak bebas rata-ratanya menurun atau tahanan listrik menjadi naik dan kisi kristal terdistorsi didapat dari paduan Aluminium

The development of materials technology, especially for the application of electrically conductive wires causing a shift to materials used for electrical conductors previously using copper and are now starting to be shifted by Aluminum alloy. The shift is caused by aluminum alloys have advantages over copper wire, among others; lower specific gravity, easy manufacturing process, cheaper price. Conductor materials are not always at the ideal environment.
The issue of air pollution does not escape from the conductor material quality in the field, one example is acid rain. Acid rain can affect the quality of the conductor material. Acid rain can create corrosion and lowers conductivity. This study aimed to obtain the decrease in the conductivity of the conductor material of aluminum and aluminum alloy conductors by testing contaminated by H2SO4solution Conductor material used is pure aluminum, AlZrCe Mg + 1% + Al2O31% and AlZrCe + Al2O3 1%.
The study was conducted by immersing the conductor material in solution H2SO4 1%, 3%, and 5% for 7 days and the data taken on the first, second, third and seventh. The first day of the seventh conductivity and conductivity decreased due to the dissolution of the items to aluminum and aluminum alloys. Initial conditions IACS conductivity of pure aluminum on the seventh day or 7x24 hours decreased 57.584% IACS into a solution of 1%, 56.486% IACS in a solution of 3% and 55.632% IACS at a 5% solution. This may occur because the free electrons which pass through a crystal lattice that is distorted, then the electrons will be deflected so that the mean free path decreases or the electrical resistivity to be increased and distorted crystal lattice obtained from Aluminum alloy.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64614
UI - Skripsi Membership  Universitas Indonesia Library
cover
Annisa Nur Adri Muttaqin
"

Carbon nanotubes (CNT) umum digunakan sebagai filler karena sifat mekanik, elektrik, dan termal yang baik. Fungsionalisasi non-kovalen memodifikasi CNT menjadi lebih hidrofilik tanpa merusak struktur permukaan CNT atau mengurangi kemampuan mekanik. Sericin memiliki asam amino aromatik yang mampu memodifikasi CNT dengan fungsionalisasi non-kovalen melalui sonikasi. Fungsionalisasi ini dilakukan dengan variasi muatan CNT 1,3, 5 dan 7. Matriks yang digunakan berupa styrene buatdiene latex (SBR) dengan campuran dicumyl peroxide (DCP). Kenaikan muatan CNT dalam komposit meningkatkan kekuatan tarik, modulus elastisitas, dan densitas cross-linking. CNT terfungsionalisasi (CNT-f-SS) meningkatkan kekuatan tarik dari 2,53 Mpa menjadi 3,03 Mpa dan modulus elastisitas dari 4,74 Mpa menjadi 20,26 Mpa. Densitas cross-linking juga meningkat dari 0,153 mol/cm3 menjadi 0,177 mol/cm3, dan nilai konduktivitas listrik dari 0,0025 S/m menjadi 0,0321 S/m.

 


Stretchable conductors are components used in soft electronics due to its flexibility, soft, and wearable. Carbon nanotubes (CNT) are commonly used as fillers due to its good mechanical, electrical and thermal properties. Non-covalent functionalization is employed to enhance the hydrophilicity of carbon nanotubes (CNT) while preserving their surface structure and mechanical properties. Sericin has an aromatic amino acid which is capable of modifying CNTs by non-covalent functionalization via sonication. This functionalization process was performed with varying CNT loads of 1, 3, 5, and 7. The composite material consisted of styrene made diene latex (SBR) combined with dicumyl peroxide (DCP). The increase in CNT loading in the composite increases the tensile strength, elastic modulus, and cross-linking density. Functionalized CNT (CNT-f-SS) increased the tensile strength from 2.53 Mpa to 3.03 Mpa and the modulus of elasticity from 4.74 Mpa to 20.26 Mpa. The cross-linking density also increased from 0.153 mol/cm3 to 0.177 mol/cm3, and the electrical conductivity value from 0.0025 S/m to 0.0321 S/m.

 

"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Noor Addin
"Pada era modern ini, kebutuhan akan energi listrik merupakan sesuatu yang sudah tidak bisa tergantikan, dimana hal ini tidak menutup kemungkinan akan terjadi banyak permasalahan baru yang akan muncul, diantaranya adalah terus meningkatnya peristiwa kebakaran yang terjadi pada instalasi tegangan rendah akibat gangguan listrik. Kebakaran ini disebabkan karena adanya hubung singkat yang menyebabkan munculnya busur api listrik. Busur api listrik muncul ketika terjadi electrical breakdown pada udara disekitar konduktor, yang menyebabkan pelepasan energi panas dan cahaya yang dihasilkan oleh listrik yang menjalar melalui udara. Sehingga dilakukan sebuah penelitian yang membahas mengenai karakteristik busur api listrik pada tegangan rendah AC. Penelitian ini dilakukan dengan sebuah simulasi artificial short circuit atau hubung singkat tiruan. Pengujian dilakukan dengan menggunakan parameter impedansi saluran berupa variasi jumlah serabut dan luas penampang konduktor yang berbeda untuk melihat pengaruhnya terhadap karakteristik arus dan tegangan yang diukur menggunakan perangkat pengukuran PicoScope. Dari hasil pengujian diketahui bahwa bentuk gelombang (waveform) busur api memiliki nilai arus yang lebih tinggi dari arus sistem yang bekerja normal dan nilai tegangan yang lebih rendah dari tegangan sistem yang bekerja normal, namun memiliki durasi yang singkat. Nilai dari impedansi saluran berpengaruh pada karakteristik arus dan tegangan dari busur api listrik. Semakin besar impedansi salurannya maka semakin kecil nilai arus busur api yang dihasilkan. Hasil pengujian menunjukkan nilai arus terbesar didapatkan saat menggunakan luas penampang kabel 2,5 mm2 dengan variasi 24 serabut dimana nilai peak nya sebesar 216,080 A dan nilai RMS arusnya sebesar 93,178 A.

In this modern era, the need for electrical energy is something that can not be replaced, where this does not rule out the possibility of many new problems that will arise, including the continuing increase in fire events that occur in low voltage installations due to electrical disturbances. This fire was caused by a short circuit which caused the appearance of an electric arc. An electric arc arises when an electrical breakdown occurs in the air around a conductor, which causes the release of heat and light energy generated by electricity that travels through the air. So a study was conducted that discussed the characteristics of electric arcs at low AC voltages. This research was conducted with an artificial short circuit simulation or artificial short circuit. Tests carried out using channel impedance parameters in the form of variations in the number of fibers and different cross-sectional area of ​​the conductor to see the effect on the characteristics of current and voltage measured using a PicoScope measurement device. From the test results it is known that the arc waveform has a higher current value than the normal working system current and the voltage value is lower than the normal working system voltage, but has a short duration. The value of the channel impedance affects the current and voltage characteristics of the electric arc. The greater the channel impedance, the smaller the arc current value generated. The test results show the largest current value is obtained when using a cross-sectional area of ​​2.5 mm² cable with a variation of 24 filaments where the peak value is 216,080 A and the current RMS value is 93,178 A."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Baihaqi A.K.
Jakarta: Lembaga Ekonomi dan Kemasyarakatan Nasional - LIPI, 1976
297.099 2 BAI u (1)
Buku Teks SO  Universitas Indonesia Library
cover
Ainul Rochman
"Sistem distribusi AC telah lama dipilih sebagai sistem distribusi yang handal karena mempunyai kelebihan dalam hal konversi tegangan. Namun demikian, penerapan sistem AC ini menyebabkan perlunya penggunaan konverter AC-DC pada setiap beban DC baik pada rumah tangga, fasilitas komersial, maupun perkantoran. Penggunaan konverter AC-DC ini menimbulkan adanya rugi-rugi konversi dimana rugi-rugi konversi ini dapat semakin meningkat seiring dengan meningkatnya penggunaan beban-beban DC. Skripsi ini membahas tentang perbandingan jatuh tegangan dan rugi daya pada sistem AC dan DC serta membahas tentang rugi-rugi konversi yang ada pada konverter AC-DC dari laptop dan ponsel. Selain itu, juga dipaparkan beberapa topologi sistem DC pada rumah tangga yang dapat menjadi alternatif untuk permasalahan rugi-rugi konversi yang ada pada sistem AC. Dari hasil pengukuran, pada AC Adapter laptop yang diuji, didapatkan bahwa konverter AC-DC ini memiliki rugi-rugi 1 W hingga 5 W dengan efisiensi rata-rata 94 %. Sedangkan pada AC Adapter ponsel yang diuji, rugi-rugi konversi rata-rata yang dihasilkan 0,6 W dengan efisiensi rata-rata 78 %.

AC system has been chosen as a reliable distribution system due to advantages in terms of voltage conversion. However, the AC system application led to the need for the use of AC-DC converters on each DC load on the residential, commercial facilities, and offices. The use of AC-DC converters led to the conversion losses where it can be increased along with increased use of DC loads. This paper discusses comparison of voltage drop and power losses between AC and DC systems and also discusses conversion losses that exist in the AC-DC converters of DC loads, especially in AC Adapter of laptops and mobile phones. Moreover, some of DC system topologies for the household that may be alternative solutions due to the conversion losses problem in existing AC system are also discussed. From the measurement results, it was found that conversion losses of AC Adapter of laptop 1 W up to 5 W with an average efficiency of 94 %. While in AC Adapter of mobile phones tested 0,6 W with an average efficiency of 78%."
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42314
UI - Skripsi Open  Universitas Indonesia Library
cover
Novagia Adita
"Saat ini, peralatan rumah tangga semakin banyak yang memanfaatkan SMPS (switched mode power supply). Pada dasarnya, SMPS dapat dicatu dengan dua macam sumber daya yakni AC dan DC. Hal inilah yang mendasari pengembangan sistem nanogrids dual power. Penelitian ini bertujuan untuk mengetahui kinerja dari Sistem DC pada peralatan rumah tangga dan membandingkannya dengan sistem AC. Beberapa jenis beban dengan variasi kapasitas yang berbeda-beda dari 50 Watt hingga 2000 Watt disuplai dengan menggunakan 3 jenis variasi sumber tegangan yaitu 220 VAC dari grid PLN, 230 VAC dari inverter dan 230 VDC dari DC-DC boost converter. Tegangan DC lebih stabil untuk segala jenis beban sedangkan tegangan AC yang bersumber dari grid PLN maupun inverter mengalami penurunan tegangan.

Nowadays, there are so many household appliances using SMPS (switched mode power supply). Basically, SMPS can be supplied with two types of resources, namely AC and DC. This is become the concern of the development of the dual power nanogrids system. This study propose to determine the performance of DC systems on household appliances and compare them with AC systems. Several types of loads with varying capacities from 50 Watt to 2000 Watt are supplied using 3 types of voltage source variations,  220 VAC from the PLN grid, 230 VAC from the inverter and 230 VDC from the DC-DC boost converter.  DC voltage is more stable for all types of loads while AC voltage either from the PLN grid or inverter has a voltage drop.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Afiat Dirghantara
"Generator Induksi adalah mesin induksi dimana rotornya berputar lebih cepat dari medan magnet putar. Salah satu jenis generator induksi adalah generator induksi berpenguat sendiri (SEIG) yang menggunakan kapasitor untuk eksitasi. SEIG memiliki kelemahan dalam menjaga tegangan agar tetap pada sifat beban yang berbeda-beda. Untuk menstabilkan tegangan beban, dibutuhkan metode atau peralatan pengatur tegangan. Salah satunya adalah konverter AC-DC-AC. Konverter ini ditempatkan antara terminal generator induksi dengan beban untuk mengendalikan aliran daya reaktif di dalam sistem.
Skripsi ini menjelaskan tentang simulasi pengaturan tegangan pada SEIG menggunakan konverter AC-DC-AC. Simulasi ini dikerjakan pada perangkat lunak MATLAB. Parameter yang digunakan pada simulasi diambil dari mesin induksi di laboratorium konversi energi listrik. SEIG disimulasikan menggunakan konverter AC-DC-AC pada beban yang berbeda-beda; resistif murni, induktif paralel, kapasitif paralel.
Analisis dari seluruh simulasi dipaparkan pada bagian akhir skripsi untuk mengetahui karakteristik hasil pengaturan tegangan pada beban yang berbeda. Berdasarkan hasil simulasi, konverter AC-DC-AC mampu meningkatkan performa tegangan di beban.
Hasil yang diperoleh, transien tegangan di beban lebih rendah dan jatuh tegangan di beban jadi berkurang. Simulasi ini menunjukkan perbedaan tegangan yang dihasilkan antara menggunakan dengan tanpa menggunakan pengatur tegangan. Kelemahan dari metode pengaturan ini adalah menghasilkan harmonik yang sangat berbahaya terutama pada beban kapasitif.

An induction generator is an induction machine whose rotor rotates faster than rotating magnetic field. One types of an induction generator is a Self Excited Induction Generator (SEIG) which uses capacitors for excitation. SEIG has weaknesses to maintain constant voltage at different load. To stabilize load voltage, methods or equipment of voltage regulation is needed, such as AC-DCAC converter. This converter is placed between terminal generator and load, to control reactive power on system.
This paper describes about voltage regulator simulation on SEIG by using ACDC-AC converter. The simulation is conducted using MATLAB software. Parameters for the simulation are taken from induction machine in the energy conversion laboratory. The SEIG is simulated using AC-DC-AC converter at different loads; pure resistive, parallel inductive, and parallel capacitive.
The analysis of the simulation is explained on the last section of the paper. It is used to know the characteristic of voltage regulation at different loads. Based on the simulation, AC-DC-AC converter can improve load voltage performance.The results are load voltage transien more deeper and load voltage drop is decreasing.
The simulation shows voltage difference produced with and without voltage regulation. The weaknesess of this method is harmonic producing that very dangerous, especially at capacitive load.
"
Depok: Fakultas Teknik Universitas Indonesia, 2010
S51193
UI - Skripsi Open  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>