Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 164151 dokumen yang sesuai dengan query
cover
Herdinda Erudite Rizkinya
"Latar Belakang: Pemeriksaan volume urine kala III merupakan salah satu komponen dalam skor Suskhan guna memprediksi retensio urine pasca persalinan. Selama ini pemeriksaan dilakukan dengan kateter urine yang berhubungan dengan peningkatan risiko infeksi saluran kemih. Ultrasonografi (USG) Dietz merupakan alternatif metode pemeriksaan volume urine. Namun, belum terdapat perbandingan antara USG Dietz dan kateter dalam pemeriksaan volume urine kala III.
Metode: Penelitian analitik korelasional dengan metode potong lintang dilakukan terhadap 30 orang ibu yang menjalani persalinan normal pervaginam di Rumah Sakit Cipto Mangunkusumo dan Rumah Sakit Umum Kota Tangerang pada Oktober 2020 hingga Desember 2021. Pasien dengan riwayat retensi urine atau memiliki indikasi pemasangan kateter kontinu dieksklusi dari penelitian. Pemeriksaan volume urine kala III dengan USG Dietz dilakukan dengan rumus volume = tinggi (cm) x lebar (cm) x 5,6. Pemasangan kateter urine dilakukan segera setelah pemeriksaan dengan USG Dietz.
Hasil: Sebanyak 30 orang subjek mengikuti penelitian ini. Didapatkan korelasi sangat kuat antara hasil pemeriksaan USG Dietz dan kateter (r = 0,788, p < 0,001). Didapatkan korelasi terbaik pada kelompok subjek dengan volume urine < 50 cc (r = 0,842, p <0,001). Didapatkan selisih antar pemeriksaan yang tidak bermakna secara statistik (p =0,133).
Kesimpulan: Hasil pemeriksaan volume urine kala III dengan USG Dietz memiliki korelasi positif kuat terhadap pemeriksaan dengan kateter urine.

Background: Examination of the third stage of labor urine volume is one of vital components in the Suskhan score to predict postpartum urinary retention. So far, the examination is done with a urinary catheter, which is associated with increased risk of urinary tract infection. Ultrasonography (USG) Dietz is an alternative method of measuring urine volume. However, there is no comparison between Dietz ultrasound andcatheter in the third stage labor urine volume examination.
Methods: A cross-sectional correlational analytic study was conducted on 30 mothers who underwent normal vaginal delivery at Cipto Mangunkusumo Hospital and Tangerang City General Hospital from October 2020 to December 2021. Patients with a history of urinary retention or indications for continuous catheter insertion were excluded
from the study. study. Examination of the third stage of urine volume with USG Dietz was carried out with the formula volume = height (cm) x width (cm) x 5.6. Urinary catheter insertion was performed immediately after examination with Ultrasound Dietz.
Results: A total of 30 subjects participated in this study. There was a very strong correlation between the results of the Dietz ultrasound examination and the catheter (r =0.788, p < 0.001). The best correlation was found in the group of subjects with urine volume < 50 cc (r = 0.842, p < 0.001). The difference between examinations was not statistically significant (p = 0.133).
Conclusion: The results of the third stage labor urine volume examination with USG Dietz had a strong positive correlation with the examination with a urinary catheter.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2021
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Joesri Djamaloeddin
"ABSTRAK
Berbagai cara untuk mengetahui derajat keterpaparan uap benzene yang dapat mengganggu kesehatan manusia, salah satunya adalah dengan kadar fenol dalam urine sebagai indikator, terutama pada para pekerja yang sehari harinya kontak dengan bahan ini.
Penelitian dengan pendekatan cross sectional ini, bertujuan untuk mengetahui sampai sejauh mana keterpaparan fenol dalam uap benzene. Hasil wawancara dan pemeriksaan kadar fenol dalam urine di laboratorium FKM Ul terhadap 57 responden yang bekerja di SUPPDN Pertamina Palembang, Balik Papan, Semarang dan Surabaya menunjukkan kadar urine rata-rata 9,333 mg/liter. Kisaran yang didapat terendah 1,354 mg/liter, tertinggi 61,351. Dari nilai ini diketahui bahwa 43 orang (75,4%) kadar fenolnya dibawah 10 mg/liter masih dalam batas normal, dan 14 orang (24,6 %) diatas l0 mg/liter dianggap sudah terkena pemaparan uap benzene.
HasiI analisis bivariat, dari 5 variabel yang dijadikan model, hanya 2 variabel yang bermakna yaitu lama kerja dengan kadar fenol dalam urine (p=0,000) dan penggunaan alat pelindung dengan kadar fenol dalam urine (p=0,000). Analisa multivariat dari ketiga variabel yang menjadi model tidak ada satupun menunjukkan hasil yang bcrmakna p hitung > p=0,05.
Studi ini membuktikan bahwa ada perbedaan lama kerja dan penggunaan alat pelindung faktor yang dapat mengurangi pemaparan para pekerja dari uap benzene.
Maka sebagai saran untuk mengantisipasi terhadap pemaparan uap benzene yang berbahaya ini perlu dilakukan usaha antara lain, memindahkan karyawan yang telah bekerja lebih dari 5 tahun ketempat lain, untuk memulihkan kesehatannya kembali. Penggunaan alat-alat pelindung dengan baik dan benar secara lengkap ketika sedang bekerja dan mengganti alat alat pelindung yang sudah tidak layak digunakan. Pemeriksaan kesehatan secara berkala pada karyawan untuk mencegah terjadi kelainan dan penyakit akibat pemaparan benzene serta pemantauan kadar benzene dalam udara ditempat kerja minimal 3 bulan sekali.

ABSTRACT
There are various ways to detect benzene vapor exposure that jeopardize the human health. One is through indicator to ensure the content of phenol level in urine, especially among employees who have a direct daily contact to this chemical.
Research through cross sectional approach is targeting to detect how far their (employees) exposure of benzene vapor. Interview and checking phenol content In urine of 57 respondents working at the SUPPDN Pertamina Palembang, Balikpapan, Semarang and Surabaya at the laboratory of FKM UI shows that the average phenol content is 9.333 mg/liter. The lowest content is 1.354 mg/liter and the highest 61.351 mg/liter. It is detected that phenol content of 43 people (75.4%) is under 10 mg/liter and below the normal limit, and 14 others (24.6%) above 10 mg/liter and considered exposed to benzene vapor.
Bivariate analysis shows that there are only 2 from 4 model variables which are meaningful. I.e. working period and phenol content in urine (df 1 p=0.000) and the use of protecting tools with phenol content in urine (df 1 p=0.000). Multivariates analysis of the 3 variables shows no meaningful result of p count > p=0,05.
The study proves that the difference of working period and using the protecting instruments can reduce the exposure of employees toward benzene vapor.
To anticipate the exposure of hazardous benzene vapor, we suggest to do several acts such as: relocating employees who have been working for 5 years to another locations to get them recovered; utilizing protecting Instruments well when working and replacing the damaged or out of date ones; regular general check-up to prevent abnormality and sickness caused by benzene level: and monitoring of benzene content in working area per 3 months minimally.
"
Depok: Universitas Indonesia, 1996
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
David Christian El Gah
"Latar belakang: Luka bakar adalah keadaan gawat darurat medis yang membutuhkan penanganan komprehensif sesuai dengan penyebab dan tingkat keparahan. Terapi resusitasi cairan sangat penting untuk mencegah atau mengatasi syok hipovolemik. Prinsipnya adalah memberikan cairan secara konservatif untuk mencapai tujuan resusitasi tanpa menyebabkan ekstravasasi cairan, yang dapat meningkatkan tekanan intraabdomen (TIA). TIA yang tinggi dan persisten dapat menyebabkan hipertensi intraabdomen (HIA) dan sindrom kompartemen abdomen (SKA). Formula Parkland tetap menjadi standar untuk resusitasi cairan, dengan menggunakan produksi urine (UO) sebagai penilaian kecukupan resusitasi.
Metode: Subjek dalam penelitian ini adalah pasien luka bakar yang mendapatkan resusitasi cairan di ULB RSCM dan memenuhi kriteria inklusi dan eksklusi. Penelitian ini menggunakan desain studi cross sectional untuk mengetahui korelasi antara TIA dan UO dan bersumber dari data primer. Pengambilan data dilakukan selama fase resusitasi cairan 24 jam pertama. Pengukuran TIA dilakukan setiap 6 jam, sedangkan pengukuran UO dilakukan setiap 1 jam.
Hasil: 12 pasien terinklusi dalam penelitian ini. Korelasi antara TIA dan UO 6 jam pertama bernilai lemah positif (r =0,225), pada 6 jam kedua korelasi lemah negatif (r = -0,226), pada 6 jam ketiga korelasi sedang negatif (r = -0,524), pada 6 jam keempat tidak terdapat korelasi (r = -0,120), pada korelasi secara keseluruhan selama 24 jam didapatkan korelasi lemah negatif (r = -0,208) tanpa adanya signifikansi secara keseluruhan (p > 0,05). Lebih lanjut, ditemukan korelasi antara %TBSA dengan jumlah cairan resusitasi selama 24 jam tergolong sangat kuat (r = 0,890) dan signifikan, korelasi antara %TBSA dengan rerata TIA selama 24 jam tergolong lemah positif (r = 0,226, p > 0,05), dan korelasi antara jumlah cairan resusitasi dan TIA rerata tergolong sedang positif (r = 0,467, p > 0.05).
Kesimpulan: Tidak terdapat korelasi secara signifikan (p > 0.05) antara tekanan intraabdomen terhadap urine output pada pasien luka bakar selama fase 24 jam resusitasi cairan pertama di ULB RSCM.

Introduction: Burns are urgent medical emergencies requiring comprehensive management based on etiology and severity. Fluid resuscitation therapy is crucial to prevent or manage hypovolemic shock. The principle is to administer fluid conservatively to achieve resuscitation goals without causing fluid extravasation, which can lead to intra-abdominal pressure (IAP) elevation. Persistent high IAP can result in intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS). The Parkland formula remains standard for fluid resuscitation, utilizing urine output (UO) to assess adequacy.
Methods: Subjects in this study were burn patients who received fluid resuscitation at ULB RSCM and met the inclusion and exclusion criteria. This research uses a cross-sectional study design to determine the correlation between TIA and UO and is sourced from primary data. Data collection was carried out during the first 24 hours of fluid resuscitation phase. IAP measurements are carried out every 6 hours, while UO measurements are carried out every 1 hour.
Result: 12 patients were included in this study. The correlation between IAP and UO in the first 6 hours was weakly positive (r = 0.225), in the second 6 hours the correlation was weakly negative (r = -0.226), in the third 6 hours the correlation was moderately negative (r = -0.524), in the fourth 6 hours it was not there is a correlation (r = -0.120), in the overall correlation for 24 hours there is a weak negative correlation (r = -0.208) with no overall significance (p > 0.05). Furthermore, it was found that the correlation between %TBSA and the amount of resuscitation fluid for 24 hours was classified as very strong (r = 0.890) and significant, the correlation between %TBSA and average IAP for 24 hours was classified as weakly positive (r = 0.226, p > 0.05), and the correlation between the amount of resuscitation fluid and average IAP was moderately positive (r = 0.467, p > 0.05).
Conclusion: There is no significant correlation (p>0.05) between intra-abdominal pressure and urine output in burn patients during the first 24hour phase of fluid resuscitation at ULB RSCM.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2024
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Universitas Indonesia, 2001
TA966
UI - Tugas Akhir  Universitas Indonesia Library
cover
Jakarta : Restu Agung , 2005
612.461 BUK
Buku Teks  Universitas Indonesia Library
cover
New Jersey: Roche, 1985
616.8047 URI
Buku Teks SO  Universitas Indonesia Library
cover
Harahap, Yahdiana
"Telah dilakukan penelitian tentang profil teofilin dalam plasma dan urine setelah pemberian peroral kapsul teofilin yang berisi 150 mg teofilin.
Penelitian dilakukan terhadap 12 orang sllicarelawan pria yang sehat, berat badan berkisar antara 45 sampai 58 kg, umur berkisar antara 19 sampai 25 tahun.
Pengambilan darah dilakukan sebelum obat diberikan, 30, 60, 120, 240 dan 360 menit setelah obat diminumo Urine dikumpulkan pada interval waktu tertentu selama 30 jam. Konsentrasi teofilin dalam plasma dan urine ditetapkan secara spektrofotomeri.
Dari hasil penelitian dida:patkan kadar terapi teofilin dalam plasma tidak tercapai setelah pemberian 150 .. · mg teo£ilin. Ada hubungan antara pro£il teo£ilin dalam plasma dan urine dimana waktu untclr mencanai ekskresi puncak. teo£ilin dalam urine dua kali 1t-1aktu untclt mencapai kadar puncak teofilin dalam plasma. Juga diperoleh parameter-paraiL'!eter farma.'l.cokinetik seperti 1,-mktu paruh (t"l/2), tetapan kecepatan eliminasi dan ekskresi teofilin dalam urine kUt'Tlulatif."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1987
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nining Restu Kurnianingsih
"Telah dilakukan penelitian tentang profile teofilin dalam plasma
dan urine setelah pemberian.peroral ka psul teofilin yang berisi 300
my teofilin..
Penelitian tersebut dilakukan terhada p 12 orang sukarelawan
yang sehat, berat badan berkisar antara 47 sampal 58 kg. umur
berkisar antara 17 sam pai 28 tahun. Pengambilan darah dilakukan
sebelum obat diberikan, 60, 120, 180, 240, 360, 480 menit setelah
ohat diminum. Urine dikump ulkan pada interval waktu tertentu selama
48 jam. Konsentrasi teofilin daiarn plasma dan urine ditetapkan secara
spektr ofotometri.
Dari hasil penelitian didapatkan kadar terapi teofilin dalam
plasma dapat dicapal dengan pembenian 300 my teofilin. Ada hubungan
antara profil teofilin dalam plasma dan urine dimana waktu untuk
mencapai ekskresi puncak.teofilin dalam urine sama dengan waktu untuk
mencapai kadar puncak teofilin dalam plasma pada t mid. Juga
diperoleh parameter-parameter farmakokinetik seperti waktu oaruh
teofilin (1 1/2), tetapan kece patan eliminasi (Ke), tetapankecepatan
abbsorpsi (Ka) dan ekskresi teofilin dalam urine kumulatif.

The studies of theophylline profile in plasma and urine after
given theophylline orally capsule which contain 300 mg theophylline -
has been carried out.
The studies involved twelve healthy male volunteers, the range
of body weight are beetwen 47 to 58 kg and the ages are between 17 to
28 years old. Blood samples were taken right before the drug was
administered and 60, 120, 180, 240, 360, 480 minutes after that.
Urine samples were collected at regular intervals over 48 hour
periods. The concentration of theophylline in plasma and urine
samples were determined by spectrophotometric method.
From the data obtained, we observed that the therapeutic
concentration of theophylline was reached after given 300 mg
theophylline. There was relationship between theophylline profile in
plasma and urine, in which the time needed to reach the maximum
theophylline excreation in urine was same as the time needed to reach
the maximum theophylline plasma concentration at t mid. From the data
we also observed the pharmacokinetic parameters as the half ii:fe-
(T1/2) elimination rate constant ( Ke ), absorption rate constant (
Ke ) and cumulative urinary excretion.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1988
S31821
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Bina Akura
"Hiperplasia adrenal kongenital (HAK) adalah gangguan yang ditandai dengan defek pada enzim jalur steroidogenesis adrenal. Lebih dari 90% disebabkan mutasi pada CYP21A2 yang mengkode enzim 21-hidroksilase (21-OH). Monitoring tata laksana pasien HAK cukup sulit dicapai dengan menjaga keseimbangan antara overtreatment dan undertreatment.
Penelitian bersifat cross sectional dilakukan di RSCM berlangsung selama 7 bulan (Juni-Desember 2020). Pemilihan sampel dilakukan dengan consecutive sampling dengan total 142 sampel. Sampel pasien HAK sebanyak 71 pasien, serta pemilihan sampel kontrol dilakukan dengan matching jenis kelamin dan usia. Kelompok HAK dilakukan pemeriksaan kadar 17-hidroksiprogesteron (17-OHP) serta androsteron, etiokolanolon urin dan rasio androsteron/etiokolanolon urin (A/E). Uji korelasi dilakukan antara androsteron, etiokolanolon, rasio A/E dengan 17-OHP. Kelompok kontrol dilakukan pemeriksaan androsteron, etiokolanolon urin dan rasio A/E. Hasil kedua kelompok dilakukan komparasi.
Dari 71 kelompok HAK dan 71 kelompok kontrol mempunyai karakteristik dasar yang sebanding. Kadar androsteron kelompok HAK dibandingkan dengan kelompok kontrol berbeda bermakna (683,89(29,42-61061,43) vs 123,97(30,16- 16463,05) ng/mL;p<0,001). Kadar etiokolanolon kelompok HAK berbeda bermakna dibandingkan dengan kelompok kontrol (235,88(12,77-78446,65) vs 70,96(12,61-17332,62)ng/mL;p<0,001). Rasio A/E kelompok HAK berbeda bermakna dibandingkan dengan kelompok kontrol (2,31(0,37-40,12) vs 1,99(0,52- 5,45); p0,003). Kadar androsteron, etiokolanolon, rasio A/E mempunyai korelasi positif dengan kadar 17-OHP (r=0,505; r=0,367; r=0,313).
Kesimpulan: Androsteron, etiokolanolon dan rasio A/E mempunyai kadar yang lebih tinggi pada pasien HAK. Androsteron mempunyai korelasi sedang, etiokolanolon dan rasio A/E mempunyai korelasi lemah terhadap 17-OHP.

Congenital adrenal hyperplasia (CAH) is a disorder characterized by defects in one of the enzymes of the adrenal steroidogenesis pathway. More than 90% of cases are due to mutations in CYP21A2, the gene coding for 21-hydroxylase (21-OH) enzyme. Treatment monitoring in CAH patients is quite difficult to achieve due to fine balance of overtreatment and undertreatment.
Cross sectional study was conducted in RSCM for 7 months (June-December 2020). Consecutive sampling was used with total 142 samples. There were 71 patients CAH were included in this study. Control samples were selected by matching age and sex. In CAH group, 17-hydroxyprogesterone (17-OHP), urine androsterone, etiocholanolone, and ratio androsterone/etiocholanolone (A/E) were measured. Correlations were measured between androsterone, etiocholanolone, ration A/E with 17-OHP. In control sample urine androsterone, etiocholanolone, and ratio androsterone/etiocholanolone (A/E) were also measured. These results were compared between two groups.
In 71 CAH group and 71 control group had almost same characteristics. Androsterone level in CAH group had a significant different compared to the control group (683.89(29.42-61061.43) vs 123.97(30.16-16463.05) ng/mL;p<0.001). Etiocholanolone level in CAH group had a significant different compared to the control group (235.88(12.77-78446.65) vs 70.96(12.61- 17332.62)ng/mL; p<0.001). Ratio A/E n CAH group had a significant different compared to the control group (2.31(0.37-40.12) vs 1.99(0.52-5.45); p=0.003). Androsterone, etiocholanolone and ratio A/E had positive correlation with 17-OHP level (r=0.5050; r=0.367; r=0.313).
Conclusions: Androsterone, etiocholanolone, and ratio A/E had higher level in CAH subjects. Androsterone had intermediate correlation with 17-OHP, meanwhile etiocholanolone and ratio A/E had weaker correlation.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2021
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>