Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 163278 dokumen yang sesuai dengan query
cover
Teuku Nanda Putra
"Maxillofacial trauma is one of the most devastating injuries faced by all plastic
surgeons. In the event of displacement and unstable fracture segments, which can lead
to functional disruption, an open reduction and an internal fixation using miniplate and
screws are indicated. However, currently commonly used imported miniplate and screw
are very costly. The purpose of this study is therefore to evaluate the locally
made miniplate and screw in maxillofacial fracture management compared to the
imported miniplate and screw. The study is a blind randomized clinical trial of patients
with mid-face fractures arriving at Cipto Mangunkusumo Hospital. Subjects are fracture
lines that meet both inclusion and exclusion criteria and are then randomized to the
study (locally made miniplate and screw) and control (BIOMET ® miniplate and screw)
through a predetermined randomization list. Bone density is followed by non-contrast
head tomography immediately after surgery as a baseline and three months post-op.
Subsequently, a radiologist consultant as a blinded evaluator will evaluate the bone
density score and any screw loosening present local tissue reactions after fixation during
a visit to the outpatient clinic once a week for three weeks. The preliminary result of the
first 9 samples suggested the locally-made miniplate and screw showed the same quality
compare to the control. Bone density promoted by both implants was not significant
difference (P>0.05). There was no tissue reaction presentation around both implant
placement and nor the screw loosening appears at the three-month CT-Scan evaluation.
Due to the COVID-19 pandemic, it is difficult to reach the number of samples as
planned, the clinical study was underpowered. Further clinical study is necessary to
improve the self-taping feature of the screw and reaching a more power study in order
to establish the non-inferiority of locally made miniplate and screw.

Trauma maksilofasial adalah salah satu cedera paling parah yang dihadapi semua ahli
bedah plastik. Jika terjadi pergeseran dan segmen fraktur yang tidak stabil, yang
menyebabkan gangguan fungsi, maka diindikasikan untuk dilakukan tindakan reduksi
terbuka dan fiksasi internal menggunakan miniplate dan screw. Namun saat ini
miniplate dan screw impor yang biasa digunakan sangat mahal harganya. Oleh karena
itu, tujuan dan penelitian ini adalah untuk mengevaluasi miniplate dan screw buatan
lokal dalam manajemen fraktur maksilofasial yang dibandingkan dengan miniplate dan
screw impor. Desain penelitian adalah blind randomized clinical trial yang dilakukan
pada pasien dengan fraktur wajah bagian tengah yang datang ke Rumah Sakit Cipto
Mangunkusumo. Subjek penelitian ini adalah garis fraktur yang memenuhi kriteria
inklusi dan eksklusi dan kemudian akan dimasukkan kedalam grup intervensi (miniplate
dan screw buatan lokal) dan grup kontrol (BIOMET ® miniplate dan screw) secara acak
berdasarkan predetermined randomization list. Kepadatan tulang akan dievaluasi
menggunakan CT-Scan kepala non kontras segera setelah operasi sebagai baseline dan
dilakukan kembali tiga bulan pasca operasi. Selanjutnya dokter konsultan radiologi
yang bertindak sebagai blind evaluator akan mengevaluasi nilai kepadatan tulang dan
apakah ada tampilan screw yang longgar pada gambaran CT-Scan. Reaksi jaringan lokal
disekitar lokasi pemasangan implant juga akan dievaluasi setiap minggu selama tiga
minggu pada saat pasien menjalani perawatan melalui poliklinik bedah plastik. Hasil
studi pendahuluan terhadap 9 sampel awal menunjukkan bahwa miniplate dan screw
buatan lokal memiliki kualitas yang sama dengan miniplate dan screw impor. Tidak ada
perbedaan signifikan (P>0.05) pada kepadatan tulang yang dihasilkan oleh kedua
Miniplate dan screw. Tidak ada reaksi jaringan sekitar pemasangan implant yang terjadi
selama pengamatan dan juga tidak ada tampilan screw loosening pada CT-Scan tiga
bulan pasca operasi. Jumlah sampel yang sedikit akibat pandemik COVID-19
menyebabkan studi ini underpowered. Dibutuhkan studi lanjutan guna memperbaiki
fitur self-taping pada screw dalam rangka membuktikan bahwa Miniplate dan screw
buatan lokal tidak lebih inferior.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2020
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Narottama Tunjung Hariwangsa
"Reduksi secara tertutup dan fiksasi internal menggunakan miniplate dan screw titanium masih merupakan modalitas terapi yang terbaik untuk fraktur tulang wajah yang displaced dengan gangguan fungsi dan deformitas secara penampilan. Namun, implan maksilofasial yang beredar di Indonesia masih sangat mahal. Untuk itu diperkenalkan miniplate dan screw buatan lokal (UniFIX®) yang lebih murah dan memiliki kualitas yang sama dengan miniplate dan screw yang diimpor. Dilakukan studi eksperimental cross over dengan menggunakan enam belas model tengkorak dari bahan polyurethane yang dipasang implan UniFIX® dan implan impor pada bagian rima orbita inferior oleh pengguna. Dilakukan pencatatan terhadap waktu untuk menyelesaikan pemasangan miniplate dan screw. Setiap pengguna diberikan kuesioner evaluasi terhadap kemudahan penggunaan miniplate dan screw dalam hal kenyamanan saat penggunaan, kecocokan screw dengan screwdriver, pembengkokan plate, dan self-tapping dari screw. Setelah itu, dilakukan penilaian oleh konsultan ahli kraniofasial terhadap stabilitas dan adaptabilitas dari miniplate dan screw yang telah dipasang. Hasil penelitian menunjukkan bahwa miniplate dan screw UniFIX® tidak inferior jika dibandingkan dengan miniplate dan screw impor dalam hal kemudahan penggunaan. Meskipun demikian, karakteristik self-tapping screw UniFIX® dapat ditingkatkan untuk mendapatkan kualitas yang lebih baik.

Open reduction and internal fixation using miniplate and screw is still the best treatment of displaced facial fracture with functional impairment and cosmetic deformity. However, imported miniplate and screw currently widely used are highly costly. Therefore, a locally-made miniplate and screw (UniFIX®) which is cost-efficient and has the same quality with the imported brand is introduced. This study aims to evaluate the usability of UniFIX® miniplate and screw in comparison with the imported miniplate and screw. Cross over experimental study was conducted with sixteen polyurethane anatomical skull models. Both UniFIX® and imported miniplate and screw were placed on the infraorbital rims by users. Time to complete the placement was recorded. Each user received questionnaire to evaluate the usability of miniplate and screw in terms of operator s comfort, screw fit to screwdriver, plate bending, and self-tapping of the screw. Subsequently, two craniofacial consultants were given scoring sheet to evaluate the stability and the adaptability of each miniplate and screw. The results showed that the usability of UniFIX® miniplate and screw was not inferior compared to the imported brand. Nevertheless, the self-tapping feature of locally-made screw may be improved to produce better quality."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
T57601
UI - Tesis Membership  Universitas Indonesia Library
cover
Tasya Anggrahita Rinintyaring P.
"

Pananganan Fraktur Kraniomaksilofasial dengan metode Open Reduction Internal Fixation (ORIF) menggunakan miniplat titanium implant, adalah suatu modalitas yang paling superior. Namun demikian, Implant titanium yang beredar di Indonesia hingga saat ini adalah produk impor yang memiliki harga yang sangat tinggi. Maka dari itu, tim penelitian kami mengembangkan miniplat titanium implant buatan lokal yang lebih cost-efficient. Diharapkan miniplat yang kami kembangkan memiliki histokompatibilitas dan dapat memilliki penyembuhan tulang yang sama dengan produk impor. Penelitian ini adalah studi eksperimental menggunakan hewan coba berupa kelinci jenis New Zealand White Rabbit, yang dikelompokan menjadi 2 group. Setelah dilakukan osteotomi satu sisi pada arkus Zigoma, setiap grup akan dilakukan reduksi terbuka dan fiksasi garis fraktur menggunakan salah satu implant miniplat impor (Biomet®) ataupun implant lokal (UniFix®).  Setelah 5 hari, 4 minggu dan 8 mingu post operasi, 5 kelinci pada masing-masing grup akan di euthanasia dan dilakukan pengambilan sampel untuk pemeriksaan mikroskopik untuk mengevaluasi rasio penyembuhan tulang dan biokompatibilitas diantara masing-masing grup. Dari pengamatan, tidak ditemukan adanya komplikasi penyembuhan luka , seperti infeksi, seroma, maupun hematoma. Adapun tulang berhasil mengalami penyembuhan luka sesuai timeline, meskipun ditemukan kuantitas lamellar bone yang lebih besar pada treatment grup di minggu ke 8, dan signifikan secara statistik (Mean (%) treatment 65.3 (±3.7), and control 52.2 (±6.5) with p= 0.028). Adapun ditemukan pula pembentukan jaringan fibrokartilage pada hari ke 5, yang pada akhirnya berubah menjadi tulang matur pada periode selanjutknya. Jaringan fibrocartilage juga ditemui sedikit lebih besar pada minggu ke-8 pada grup komtrol (Mean (%) treatment 6.7(±6.4) and control 17(±3.3),p=0.038). Sel sel inflamatorik disekitar insersi screw dan jaringan granulasi pada lokasi garis fraktur tampak  mencapai puncaknya pada hari ke5, sebagai tanda proses natural dari fase inflamasi. Metal debris terdetaksi pada hampir semua sampel, dimana tidak ada perbedaan secara signifikan (n/total treatment 12(13), control 12(13), p=1.000). Namun demikian, adanya metal debris yang terdeteksi tidak memicu terbentuknya sel inflamatorik dan formasi dari sel giant. Studi ini menandakan fiksasi untuk fraktur midfacial dengan implant buatan lokal (UniFIX) menunjukkan histokompatibilitas yang baik, dan dapat mencapai penyembuhan tulang yang baik, serta tidak lebih inferior dibandingkan implant produk impor. Studi ini juga menunjukkan bahwa UniFIX adalah suatu modalitas fiksasi interna yang menjanjikan dan memerlukan support bersama untuk kemajuan dan pengembangannya di masa depan.


Open reduction and internal fixation by rigid titanium miniplate fixation had become the superior modalities for managing the craniomaxillofacial fractures. However, the titanium miniplate and screw available in Indonesia to-date is all high cost imported product. Therefore, our team is developing a locally made titanium miniplate and screw fixation with more cost-efficiently. It is hoped this locally-made titanium miniplate and screw (UniFix®) could provide the same histocompatibility and could provide adequate bone healing as the imported one. This study is an experimental study using 30 New Zealand white rabbits that divided into 2 groups. After performing one-sided zygomatic arch osteotomy, each group will be performed open reduction and applied whether a standardized imported mini-plate and screw (Biomet®) as group 1 or a locally made mini-plate and screw (UniFix®) as group 2. After 5 days, 4 week, and 8 weeks postoperatively, 5 rabbits on each group is euthanized and microscopic evaluation is conducted to evaluate the rate of bone healing and biocompatibility between each group. We have not seen any wound complication with respect of infection, seroma, and hematoma during observation of 5 days, 28 days, and 56 days. The bone is healed according to the timeline on both groups, although we found the treatment group had greater quantity of lamellar bone on day 56, and its statistically significance (Mean (%) treatment 65.3 (±3.7), and control 52.2 (±6.5) with p= 0.028). Though we also found fibrocartilage callus present around the fracture site especially the 5th day, but the fibrocartilage callus succeeded to turn over into mature bone in later period. We still found slightly bigger amount of fibrocartilage tissue on the 56th day on control group (Mean (%) treatment 6.7(±6.4) and control 17(±3.3),p=0.038). The inflammatory cells around the screw insertion and the granulation tissue of the fracture site had the highest peak on the 5th day observation marking the nature of inflammatory phase of bone healing. Metal debris found on both of the samples with no significance difference (n/total treatment 12(13), control 12(13), p=1.000). But the presence of metal debris hardly provokes any inflammatory cells and giant body formation around the screw site.This study shows the fixation of midfacial fracture using UniFIX presents good histocompatibility and adequate fracture healing and it is not inferior compared to the imported brand. This study also shows that UniFIX is a promising internal fixation modality and it needs further encouragement for future improvement and development

 

"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
T55576
UI - Tesis Membership  Universitas Indonesia Library
cover
Evi Febriani Listio Rahayu
"ABSTRAK
Latar Belakang Pada penatalaksanaan fraktur maksilofasial secara internal fiksasi diperlukan pemasangan alat miniplate dan screw sampai terjadi penyembuhan tulang Magnesium memiliki potensi sebagai miniplate dan screw pada tulang rahang dengan syarat bersifat biokompatibel dan biodegradasi sehingga tidak diperlukan operasi kembali untuk pengambilan miniplate dan screw Proses equal channel angular pressing ECAP merupakan salah satu metode untuk mengontrol laju korosi logam magnesium dan meningkatkan sifat mekanisnya Untuk pembuatan desain miniplate dan screw dari magnesium ECAP dengan merujuk dari desain safety factor bahan titanium yang biasanya telah digunakan perlu disesuaikan dengan material properti magnesium agar dapat mencegah kerusakan Tujuan menganalisa perbandingan desain miniplate dan screw logam magnesium ECAP terhadap titanium Metode Untuk penelitian ini kami menggunakan metode finite elemen yaitu formulasi perpindahan untuk menghitung perpindahan komponen strain dan tekanan di bawah beban internal dan eksternal Kemudian desain miniplate dan screw dari magnesium ECAP dilakukan analisa simulasi pembebanan yang dianalisa menggunakan teori Von Misses Hasil Hasil desain miniplate dan screw magnesium ECAP yang diharapkan dapat digunakan pada penatalaksanaan fraktur maksilofasial telah dilakukan simulasi pembebanan dengan dilakukan analisa desain menggunakan teori Von Misses kemudian desain direkayasa untuk mengurangi stress yang diterima desain rekayasa magnesium ECAP dibuat menjadi dua tipe yaitu tipe 1 dengan menambah jumlah screw menjadi 8 screw dengan berat total miniplate dan screw sebesar 118 212 mg dan tipe ke 2 dengan merubah diameter head screw menjadi 2x lebih besar dari bentuk semula sehingga berat totalnya sebesar 169 414 mg Kesimpulan Desain alternatif miniplate dan screw magnesium ECAP tipe 1 dapat lebih efektif untuk digunakan pada penatalaksanaan fraktur maksilofasial ABSTRACT
Background In the internal fixation management of maxillofacial fractures the placement of miniplate and screw is necessary until bone repair takes place Magnesium has the potential as a miniplate and screw for the jaws with it rsquo s biocompatibility and biodegradability so that a follow up surgery to remove the miniplate and screw is not necessary The equal channel angular pressing ECAP process is a method to control the corrosion rate of magnesium and increase the mechanical properties In the making of miniplate and screw design from ECAP magnesium referring the safety factor of the titanium design that is already being used adjustments must be made with the characteristics of magnesium so damage can be avoided Objectives to analyze the comparison between magnesium ECAP miniplate and screw design against titanium Methods For this research we used the finite element method which is displacement formulation to calculate component movement strain and pressure under the internal and external load Afterwards the magnesium ECAP miniplate and screw design undergoes a loading simulation which is analyzed with the Von Misses theory Result Design of miniplate and screw magnesium ECAP which expected to be used in the management of maxillofacial fractures has been tested with the stress simulation using Von Misses theory then the design engineered to reduce stress received Engineering design of magnesium ECAP divided into two types type 1 by increasing the number of screw into 8 screws with a total weight miniplate and screws with a total weight miniplate and screw amounted to 118 212 mg and type 2 by changing the diameter of the head screw becomes large than its original shape so that the total weight of 169 414 mg Conclusion Design alternative of miniplate and screw magnesium ECAP type 1could be more effective to be used in the management of maxillofacial fracture ;Background In the internal fixation management of maxillofacial fractures the placement of miniplate and screw is necessary until bone repair takes place Magnesium has the potential as a miniplate and screw for the jaws with it rsquo s biocompatibility and biodegradability so that a follow up surgery to remove the miniplate and screw is not necessary The equal channel angular pressing ECAP process is a method to control the corrosion rate of magnesium and increase the mechanical properties In the making of miniplate and screw design from ECAP magnesium referring the safety factor of the titanium design that is already being used adjustments must be made with the characteristics of magnesium so damage can be avoided Objectives to analyze the comparison between magnesium ECAP miniplate and screw design against titanium Methods For this research we used the finite element method which is displacement formulation to calculate component movement strain and pressure under the internal and external load Afterwards the magnesium ECAP miniplate and screw design undergoes a loading simulation which is analyzed with the Von Misses theory Result Design of miniplate and screw magnesium ECAP which expected to be used in the management of maxillofacial fractures has been tested with the stress simulation using Von Misses theory then the design engineered to reduce stress received Engineering design of magnesium ECAP divided into two types type 1 by increasing the number of screw into 8 screws with a total weight miniplate and screws with a total weight miniplate and screw amounted to 118 212 mg and type 2 by changing the diameter of the head screw becomes large than its original shape so that the total weight of 169 414 mg Conclusion Design alternative of miniplate and screw magnesium ECAP type 1could be more effective to be used in the management of maxillofacial fracture ;Background In the internal fixation management of maxillofacial fractures the placement of miniplate and screw is necessary until bone repair takes place Magnesium has the potential as a miniplate and screw for the jaws with it rsquo s biocompatibility and biodegradability so that a follow up surgery to remove the miniplate and screw is not necessary The equal channel angular pressing ECAP process is a method to control the corrosion rate of magnesium and increase the mechanical properties In the making of miniplate and screw design from ECAP magnesium referring the safety factor of the titanium design that is already being used adjustments must be made with the characteristics of magnesium so damage can be avoided Objectives to analyze the comparison between magnesium ECAP miniplate and screw design against titanium Methods For this research we used the finite element method which is displacement formulation to calculate component movement strain and pressure under the internal and external load Afterwards the magnesium ECAP miniplate and screw design undergoes a loading simulation which is analyzed with the Von Misses theory Result Design of miniplate and screw magnesium ECAP which expected to be used in the management of maxillofacial fractures has been tested with the stress simulation using Von Misses theory then the design engineered to reduce stress received Engineering design of magnesium ECAP divided into two types type 1 by increasing the number of screw into 8 screws with a total weight miniplate and screws with a total weight miniplate and screw amounted to 118 212 mg and type 2 by changing the diameter of the head screw becomes large than its original shape so that the total weight of 169 414 mg Conclusion Design alternative of miniplate and screw magnesium ECAP type 1could be more effective to be used in the management of maxillofacial fracture "
Fakultas Kedokteran Gigi Universitas Indonesia, 2016
SP-PDF
UI - Tugas Akhir  Universitas Indonesia Library
cover
Muhammad Raihan Bintang Abhista
"Fraktur yang terjadi pada craniomaxillofacial dapat memicu cedera lain di kepala sehingga membutuhkan penggunaan miniplate untuk fiksasi yang stabil selama proses penyembuhan. Magnesium miniplate muncul sebagai implan dengan sifat biodegradable potensial karena memiliki sifat mekanik yang sangat baik dan memiliki sifat biokompatinilitas. Namun, kinerja dan stabilitas sifat mekanisnya saat terpapar lingkungan fisiologis perlu dievaluasi secara menyeluruh. Penelitian ini menginvestigasi efek pengujian imersi dengan Hank's Balanced Salt Solution (HBSS) terhadap sifat mekanik pure magnesium miniplate untuk fraktur craniomaxillofacial. Uji perendaman bertujuan untuk mensimulasikan kondisi korosif yang akan dihadapi oleh implantasi di dalam tubuh manusia. Uji bending dilakukan untuk mengevaluasi perubahan kekuatan mekanik, elastisitas, dan perilaku retak miniplate setelah imersi. Selain itu perhitungan laju korosi juga dilakukan untuk mengetahui korelasinya dengan kekuatan mekanis pure magnesium miniplate setelah uji imersi. Hasil penelitian ini mengungkapkan bahwa perendaman dalam HBSS memiliki pengaruh signifikan terhadap sifat mekanik miniplat magnesium murni. Uji tersebut menunjukkan perubahan dalam bending strength dan bending load yang mengindikasikan potensi degradasi dan perubahan perilaku mekanik miniplat. Temuan ini berkontribusi pada pemahaman kita tentang kinerja jangka panjang dan daya tahan miniplat magnesium murni dalam konteks fraktur craniomaxillofacial. Pengetahuan tersebut sangat penting untuk mengoptimalkan desain implant dan memastikan hasil klinis yang berhasil dalam bidang bedah craniomaxillofacial.

Fractures occurring in the craniomaxillofacial region can result in additional head injuries, necessitating the use of miniplates for stable fixation during the healing process. Magnesium miniplates have emerged as potential biodegradable implants due to their excellent mechanical properties and biocompatibility. However, their performance and mechanical stability when exposed to physiological environments require comprehensive evaluation. This study investigates the effect of immersion testing with Hank's Balanced Salt Solution (HBSS) on the mechanical properties of pure magnesium miniplates for craniomaxillofacial fractures. The immersion test aims to simulate the corrosive conditions that the implant may encounter within the human body. Bending tests were conducted to evaluate the changes in mechanical strength, elasticity, and fracture behavior of the miniplates after immersion. Additionally, corrosion rate calculations were performed to determine their correlation with the mechanical strength of pure magnesium miniplates after the immersion test. The results of this study revealed that immersion in HBSS significantly influenced the mechanical properties of pure magnesium miniplates. The tests demonstrated changes in bending strength and bending load, indicating potential degradation and altered mechanical behavior of the miniplates. These findings contribute to our understanding of the long-term performance and durability of pure magnesium miniplates in the context of craniomaxillofacial fractures. Such knowledge is crucial for optimizing implant design and ensuring successful clinical outcomes in the field of craniomaxillofacial surgery."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yusman Efendi
"Kecelakaan lalu lintas mendominasi penyebab trauma craniomaxillofacial di Asia Tenggara. Pada sisi lain, angka kecelakaan lalu lintas di Indonesia terus naik seiring pertambahan kendaraan bermotor. Kondisi ini menyebabkan pengembangan miniplate, alat yang berguna untuk menangani pasien trauma CMF, menjadi suatu keharusan. Penggunaan miniplate sendiri mengalami rintangan di beberapa bagian, terlebih fraktur kompleks yang memerlukan geometri yang unik. Riset ini bertujuan untuk membuat miniplate yang dapat memenuhi kebutuhan akan geometri ini. Riset ini menggunakan produk komersial sebagai pembanding dan jurnal ilmiah sebagai referensi. Proses yang dilakukan adalah membuat model CAD, analisis teoritis, analisis finite element, pembuatan purwarupa, dan sejumlah revisi desain. Hasil analisis menunjukkan bahwa kebanyakan tipe dapat menahan beban yang akan diterima oleh miniplate secara teori. Namun, pada proses fabrikasi, ditemukan bahwa sejumlah tipe sulit untuk dibuat dengan mesin yang ada. Sehingga dari tipe-tipe yang diajukan, hanya satu yang dapat dibuat. Metode fabrikasi dari tipe ini menggunakan CNC milling dengan miniplate komersial yang ada sebagai bahan baku. Hasil yang didapat dengan metode ini sesuai dengan geometri desain dengan beberapa catatan.

Traffic accidents dominate the cause of craniomaxillofacial (CMF) trauma in Southeast Asia. On the other hand, the rate of traffic accidents in Indonesia is increasing along with increased motorized vehicles. This condition led to the development of miniplate, a valuable tool for treating CMF trauma patients, becoming imperative. The use of the miniplate itself encounters obstacles in several parts, incredibly complex fractures that require unique geometries. This research aims to create a miniplate that can meet the needs of these geometries. This research uses commercial products as a comparison and uses scientific journals as a reference. The process carried out is making CAD models, theoretical analysis, finite element analysis, making prototypes, and several design revisions. The analysis results obtained that most types of designs can withstand loads that miniplates will theoretically accept. However, in the fabrication process, it was found that several types were difficult to fabricate with existing machines. So that of the proposed types, only one type can be fabricated. The fabrication method of this type uses CNC milling with existing commercial miniplates as raw materials. The results obtained by this method correspond to the desired geometry with some notes."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Eric Delbert
"Riset ini bertujuan untuk mengukur perubahan kekuatan mekanis miniplate setelah di uji imersi dengan larutan HBSS dengan pH awal 7,4. Proses yang dilakukan adalah membuat CAD miniplate, membandingkan desain miniplate dengan benchmark produk menggunakan FEM, revisi desain, fabrikasi miniplate (CNC milling, surface grinding, etc), observasi mikrostruktur miniplate, uji imersi, pengukuran perubahan massa dan pH dan uji three-point bending. Hasil pertama dari penelitian atau riset mengenai keadaan microstructure miniplate pure magnesium adalah pertambahan film atau lapisan baru pada miniplate jika uji imersi yang dilakukan semakin lama. Hal ini disebabkan mekanisme untuk menghasilkan protective layer jika klorida muncul. Lalu didapatkan perubahan massa pada waktu perendaman 1 hari, 2 hari, 4 hari dan 7 hari dari massa miniplate awal dengan rata – rata 0,35 g masing – masing yaitu 0,345 g, 0,342 g, 0,332 g dan 0,322 g. Dapat disimpulkan bahwa semakin lama hari perendaman akan mengurangi massa miniplate magnesium dikarenakan proses degradasi yang terjadi. Hasil ketiga adalah perubahan pH pada larutan HBSS saat uji imersi dari pH awal 7.4 pada masing – masing perendaman 1 hari, 2 hari, 4 hari dan 7 hari yaitu 7.93, 6.54, 6.07 dan 9.14. Dapat dilihat bahwa tingkat perubahan pH pada larutan HBSS tidak konsisten dan tidak memiliki trendline yang pasti. Hasil terakhir adalah perubahan kekuatan mekanis pada miniplate yang semakin rendah ketika dilakukan uji imersi dengan hasil maximum bending load yaitu 167,15 N, 163,51 N, 161,01 N, 157,37 N, 153,5 N dan 128,34 N. Hal ini disebabkan karena kehilangan mechanical integrity akibat proses korosi.

This study aimed at measuring changes in the mechanical strength of the miniplate after being immersed in an HBSS solution with an initial pH of 7.4. The process carried out is to make a miniplate CAD, compare the miniplate design with product benchmarks using FEM, design revision, miniplate fabrication (CNC milling, surface grinding, etc.), miniplate microstructure observation, immersion test, mass and pH change measurement and three-point bending test. The first result of research on the state of pure magnesium miniplate microstructure is the accretion of a new film or layer on the miniplate if the immersion test is carried out longer. This is due to the mechanism to produce a protective layer if chlorides appear. Then a mass change was obtained at soaking time of 1 day, 2 days, 4 days and 7 days from the initial miniplate mass with an average of 0.35 g, namely 0.345 g, 0.342 g, 0.332 g and 0.322 g, respectively. It can be concluded that the longer the immersion day will reduce the miniplate mass of magnesium due to the degradation process that occurs. The third result was a change in the pH in the HBSS solution during the immersion test from the initial pH of 7.4 at 1 day, 2 days, 4 days and 7 days immersion, respectively, namely 7.93, 6.54, 6.07 and 9.14. It can be seen that the rate of pH change in HBSS solution is inconsistent and has no definite trendline. The last result is a change in mechanical strength in the miniplate which is getting lower when the immersion test is carried out with maximum bending load results, namely 167.15 N, 163.51 N, 161.01 N, 157.37 N, 153.5 N and 128.34 N. This is due to loss of mechanical integrity due to corrosion processes."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Sidqi Hanafiah
"Pada penatalaksanaan fraktur maksilofasial secara internal fiksasi diperlukan pemasangan alat miniplate dan screw sampai terjadi penyembuhan tulang, salah satu material yang paling sering digunakan untuk memfabrikasi miniplate dan screw di pasaran adalah Titanium murni dan TI-6Al-4V, secara ekonomis titanium murni memiliki harga yang lebih tinggi dari TI-6Al-4V yang merupakan metal campuran, penilitian ini bermaksud untuk membandingkan properti mekanikal kedua material sebagai miniplate di bagian maksilofasial, serta menyesuaikan dimensi miniplate TI-6Al-4V untuk menyamai properti mekanikal Titanium Murni.

In the internal fixation management of maxillofacial fractures, the placement of miniplate and screw is necessary until bone repair takes place, materials that most commonly used to fabricate miniplates and screws are Pure Titanium and TI-6Al-4V ,Economically Pure Titanium tend to have higher price than TI-6Al-4V which is an alloy metals, this research is being held to compare the mechanical properties of both material as a miniplate that specifically used on the maxillofacial, this researacg will also adjust the design of TI-6Al-4V miniplate in order to replicate the property of pure titanium miniplate."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Kozin
"In order to reduce the dependency on imported products of railway wheels, efforts have been made to produce it in the country. The manufacture of railway wheels is done through a casting process of raw materials originated from used railway wheels. The results of the casting process requires heat treatment processes to improve the mechanical properties in accordance with the standards. This study has begun with the manufacture of test specimens for chemical composition, tensile strength, hardness and microstructure. It is followed by heat treatment processes namely normalizing, flame hardening and tempering. The normalizing process, at a temperature of 850°C with a holding time of 2 hours followed by cooling in the air, has resulted in tensile strength of 906.1 MPa and hardness of 24 HRC. The flame hardening process at a temperature of 800°C with a holding time of 60 seconds followed by water quenching has resulted in hardness of 57.33 HRC. The tempering process at a temperature of 500°C with a holding time of one hour followed by cooling in the air, has resulted in a final surface hardness of 34 to 37 HRC that complies with the railway standard with effective depth of hardening of 10 mm.

Dalam rangka untuk mengurangi ketergantungan terhadap produk impor roda kereta api, maka telah dilakukan usaha untuk membuatnya di dalam negeri. Usaha pembuatan roda kereta api dilakukan melalui proses pengecoran dengan bahan baku dari roda kereta api bekas. Hasil dari proses pengecoran tersebut memerlukan proses perlakuan panas untuk mendapatkan sifat mekanik yang sesuai dengan standar. Penelitian ini diawali dengan pembuatan spesimen untuk pengujian komposisi kimia, kekuatan tarik, kekerasan dan struktur mikro. Selanjutnya dilakukan proses perlakuan panas berupa normalizing, flame hardening dan tempering. Proses normalizing dilakukan pada temperatur 850°C, waktu penahanan selama 2 (dua) jam dan didinginkan di udara menghasilkan kekuatan tarik sebesar 906.1 MPa dan kekerasan 24 HRC. Proses flame hardening pada temperatur 800°C, waktu penahanan 60 detik dengan media pendingin air menghasilkan kekerasan permukaan sebesar 58.35 HRC. Proses tempering pada temperatur 500°C, waktu penahanan selama 1 (satu) jam menghasilkan kekerasan antara 34-37 HRC dengan kedalaman pengerasan efektif sebesar 10 mm."
Depok: Universitas Indonesia, 2012
T31280
UI - Tesis Open  Universitas Indonesia Library
cover
Thareq Wibisono
"Proses injection molding adalah salah satu tipe proses manufactur yang sangat menguntungkan dari segi presisi dan kapabilitas produksi massa. Sifat bawaan dari proses inilah yang memberikan dampak positif bagi pembuatan alat-alat medis. Salah satu alat medis yang diuntungkan adalah Cranio Maxillofacial miniplate untuk rekonstruksi wajah. Pada paper ini, kami menyajikan desain cetakan (mold) untuk miniplate Cranio-Maxillofacial untuk proses injection molding. Kami memfokuskan studi kami terutama pada prediksi efek lokasi gating, kondisi pemrosesan injeksi, dan desain sistem feed (sprue, dan runner) pada kualitas (indikasi degradasi material, cacat permukaan, penyusutan volumetrik, defleksi atau lengkungan produk, kapabilitas filling, dan weld lines) cetakan menggunakan pendekatan analitis dan numerik. Penyelidikan mengungkapkan proporsi efek dari masing-masing faktor tersebut terhadap hasil produk cetakan.  Selain itu, kami juga secara analitis memprediksi desain sistem ejeksi optimal untuk menghindari efek degradilitas baik pada produk cetakan maupun pin ejektor itu sendiri. Terakhir, kami mencoba mendesain mold base berdasarkan analisis kami.

The injection molding manufacturing process is a lucrative manufacturing option for precision product and mass production. Such nature of injection molding provides an advantageous benefit to the medical device products. One of the devices is the Cranio Maxillofacial miniplate for facial reconstruction. In this paper, we present the molding design for Cranio-Maxillofacial miniplate for injection molding process. We focus our study mainly on the effect prediction of the gating location, injection processing condition, and the feed system design on the quality (indication of material degradation and surface defects), the volumetric shrinkage, and the deflection or warpage of the molding products using analytical and numerical approaches. The investigation reveals the effect proportion of each of the said factors to the molding product result. In addition, we also analytically predict the optimal ejection system design that avoid a degrading effect for both to the molding products and the ejector pin itself. Lastly, we try to design the mold base based on our analysis."
Jakarta: Fakultas Teknik Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>