Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 162000 dokumen yang sesuai dengan query
cover
Riyan Nuryanto
"ABSTRAK
Tujuan utama dari penelitian adalah untuk mengidentifikasi komponen yang paling kritis atau paling lemah berbasis analisis RAMD. Peningkatan kinerja komponen akan dilakukan pada komponen terlemah yang ditemukan. Data time-between-failure (TBF) dan time-to-repair (TTR) dikumpulkan untuk memperkirakan reliability, availability, maintainability, dependability, dan mean-time between hazardous failure (MTBH). Berbagai ukuran kinerja pabrik seperti mean-time-to-repair (MTTR) dan mean-time-between-failure (MTBF) juga dipaparkan dalam penelitian. Permodelan kinerja sistem didasarkan pada asumsi bahwa data perbaikan dan kegagalan adalah bersifat konstan dan independen secara statistik. Untuk merepresentasikan penerapan metode yang diusulkan, Lini Produksi NPK, Water Treatment Plant dan cooling tower digunakan sebagai objek penelitian untuk studi kasus evaluasi dan peningkatan kinerja sistem. Data kegagalan dan data perbaikan dapat menjadi basis data yang berguna bagi manajemen untuk meningkatkan availability dari sistem.

ABSTRACT
The main objective of this study is to identify the most critical or weakest components based on RAMD analysis. System performance and Improvement will be performed on the most critical component. Time-between-failure (TBF) and time-to-repair (TTR) data are collected to estimate reliability, availability, maintainability, dependability, and mean-time between hazardous failures (MTBH). The dependability parameters are solely applied to those subsystems that have both constant failure rate and repair rate. Various measures of plant performance such as MTTR and MTBF are as well presented. Performance modeling of the system is carried out based on the assumption that both repair and failure data are statistically independent. To show the application of the proposed method, NPK fertilizer production line, Water Treatment Plant and Cooling Tower System as repairable production system has been provided for case studies of performance evaluation. The records of failure and repair data can be a useful database for the management of to improve system availability."
Depok: Fakultas Teknik Universitas Indonesia , 2020
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Tegar Habib
"Cooling Tower merupakan salah satu komponen penting bersama dengan mesin lainnya di suatu industri yang berfungsi untuk menurunkan temperature air. Cooling Tower sistem terbuka menggunakan air sebagai media pertukaran panas. Air yang terus bersirkulasi dapat menyebabkan kerak, korosi, dan lumut karena kualitas air menurun sehingga proses pertukaran panas di cooling tower tidak optimal. Umumnya perawatan cooling tower pada industri menggunakan bahan kimia, namun hal tersebut dianggap belum efektif. Langkah alternatif dalam menjaga kualitas air di cooling tower adalah dengan menggunakan ozon. Flowrate, temperature inlet, dan jumlah ozon terlarut yang diinjeksikan tentu berpengaruh pada cooling tower, terutama kualitas air. Tujuan dari penelitian ini adalah untuk mengetahui pengaruh temperature inlet yang divariasikan terhadap kualitas air, efektivitas cooling tower dan penghematan air. Metode yang digunakan dalam penelitian ini adalah eksperimen kuantitatif. Penilitian ini menggunakan miniatur cooling tower dengan sistem terbuka berukuran (70 x 42,5 x 53) cm. Kualitas air dari cooling tower sistem terbuka ditentukan dengan melakukan pengukuran menggunakan alat uji dan melakukan pemeriksaan laboratorium. Data yang dicatat dari penelitian ini adalah Electric Conductivity, Total Dissolved Solid (TDS), pH, alkalinitas, Ca dan Mg Hardness, Na, dan Cl, serta Range dan Approach. Data tersebut akan digunakan untuk mencari nilai Losses, Practical Ozone Scaling Index (POSI), memprediksi nilai Maximum Cycle dan Maximum Cycle of Concentration, menghitung nilai Blowdown Rate dan Make up Water yang dibutuhkan dan menghitung persentase Efektivitas Cooling Tower. Hasil yang diperoleh dari penelitian ini menunjukan bahwa temperature inlet 30? merupakan temperature inlet yang paling optimal. Ketika temperature inlet 30?, jumlah volume air blowdown dapat menurun 60,94% dan jumlah kebutuhan make up water dapat menurun 36,76%.

Cooling Tower is an important component along with other machines in an industry that functions to reduce water temperature. Open system cooling towers use water as a heat exchange medium. Water that continues to circulate can cause scale, corrosion, and moss because the quality of the water decreases so that the heat exchange process in the cooling tower is not optimal. Generally, cooling tower maintenance in industry uses chemicals, but this is considered ineffective. An alternative step in maintaining water quality in cooling towers is to use ozone. Flowrate, inlet temperature, and the amount of dissolved ozone injected certainly affect the cooling tower, especially water quality. The purpose of this study was to determine the effect of varied inlet temperature on water quality, cooling tower effectiveness and water savings. The method used in this study is a quantitative experiment. This research uses a miniature cooling tower with an open system measuring (70 x 42.5 x 53) cm. Water quality from an open system cooling tower is determined by measuring using a test kit and conducting laboratory tests. Data recorded from this study are Electric Conductivity, Total Dissolved Solid (TDS), pH, alkalinity, Ca and Mg Hardness, Na and Cl, as well as Range and Approach. The data will be used to find Losses values, Practical Ozone Scaling Index (POSI), predict Maximum Cycle and Maximum Cycle of Concentration values, calculate the required Blowdown Rate and Make up Water values and calculate the percentage of Cooling Tower Effectiveness. The results obtained from this study indicate that the inlet temperature of 30? is the most optimal inlet temperature. When the inlet temperature is 30?, the amount of blowdown water volume can decrease by 60.94% and the amount of make-up water needed can decrease by 36.76%."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Okti Giffari, auhtor
"Menara pendingin atau Cooling Tower merupakan salah satu komponen penting pada suatu pembangkit. Pada PLTP, menara pendingin berguna untuk menurunkan suhu fluida cair hasil dari perubahan fase gas-cair pada proses vakum di kondensor. Sehingga fluida cair dapat mebuang kalor panasnya ke udara luar dan dapat dipakai lagi untuk proses vakum pada kondensor. peningkatan vakum kondensor membuat hasil output listrik pada turbin semakin optimal. Oleh karena itu proses pendinginan fluida pada Menara Pendingin sangat penting. Akan tetapi proses pendinginan pada menara pendingin sangat bergantung dengan kondisi lingkungan udara lokasi pembangkit.
Pada skripsi ini penulis membuat analisis kinerja dari Menara Pendingin dengan jenis Crossflow inducted draft Cooling Tower dengan mengevaluasi hasil yang didapat dari data Control room dan data desain awal pembangkit. Dengan analisis kerja ini didapat bahwa temperatur wet bulb dari udara masuk cooling tower mempengaruhi nilai dari temperatur hasil pendinginan menara pendingin pada basin yang juga mempengaruhi kondisi tekanan vakum pada kondensor dan menyebabkan perubahan pada hasil beban generator.

Cooling tower is one of the important components of geothermal power plant. Cool-ing tower useful for lowering the temperature of liquid fluid result of the gas ?fluid changes phase in the proces of vacuum in condenser. So that the hot liquid fluid can transfer calorific heat to the outdoor air and the liquid result can be used again for the vacuum in the condenser. Condenser vacuum increase make the electrical out-put of the turbine further optimized. Therefore, the process of cooling fluid in the cooling tower is very important. But the cooling process in the cooling tower is very dependent on the environmental air plant site.
In this thesis, the author makes the analysis of the performance of the Crossflow inducted draft Cooling Tower to eval-uate the results obtained from the data Control room and plant the initial design data. The result found that the wet bulb temperature of the inlet air cooling tower affect the value of the temperature of cooling results in the cooling tower basin that also affect the condition of vacuum pressure in the condenser and cause changes in the results of the load generator
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64901
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rifqi Miftah Majduddin
"Menara Pendingin adalah suatu unit yang dapat membantu melakukan perpindahan kalor dimana kalor tersebut sudah tidak dibutuhkan lagi. Dalam operasi menara pendingin, ada beberapa faktor yang dapat dijadikan tinjauan dalam mengukur performa dari menara pendingin. Banyaknya bakteri di dalam menara pendingin menyebabkan presipitasi kerak yang dapat mengganggu efektivitas thermal dari menara pendingin dikarenakan kerak-kerak tersebut akan menghambat laju perpindahan kalor karena mempunyai resistansi thermal yang tinggi. Ada beberapa cara untuk mengurangi laju pertumbuhan dari kerak, salah satunya adalah ozonasi. Ozonasi adalah injeksi ozon pada air pendingin menara pendingin untuk mengurangi potensi dari presipitasi kerak yang akan meningkatkan performa dari menara pendingin.
Penelitian ini bertujuan untuk mengetahui karakteristik efek ozonasi terharap performa dari menara pendingin dan kualitas air pendingin pada menara pendingin sistem tertutup. Metode yang digunakan untuk menguji kualitas air adalah pengujian dengan alat ukur yang dicelupkan setiap harinya dan uji laboratorium seperti AAS, Titrimetric, Gravimetrik, dan Spectrophotometric.
Hasil yang didapat pada penelitian ini adalah karakterisitik laju performa setiap harinya dan laju kualitas air setiap harinya maupun saat sebelum dan sesudah ozonasi. Hasil dari nilai efektivitas yang didapat adalah 0.12 % untuk nilai terkecil dan 8.74 % untuk nilai terbesar. Ozonasi terbukti dapat meningkatkan kualitas air menara pendingin tetapi belum terbukti dapat meningkatkan performa atau efektivitas menara pendingin untuk jangka waktu ozonasi selama 15 hari.

Cooling tower is a unit or system that used for heat transfer process where the heat is not useful anymore. There is several factor in the cooling tower operations that can observed for cooling tower performance. The large amount of bacteria on cooling tower become potential of scale precipitation that can decrease the cooling tower thermal effectivity because of the scale will act as inhibitor for heat transfer rate since the scale has high value of thermal resistance. There are several method for reducing scale precipitation growth rate, one of them is ozonation or ozone injection method. The ozone will injected to the cooling water to reduce the scale precipitation growth rate that can decreases the cooling tower performance.
This research intends to find the characteristic of ozonation effect from cooling tower performance and water quality. The method for water quality checking are AAS method, Titrimetric, Gravimetric, and Spectrophotometric.
The output of this research are characteristic of cooling tower performance each day and rate of water quality before and after ozonation and each day. The effectiveness value results obtained in this research was 0.12 % for the lowest value and 8.74 % for the highest value. Ozonation has been proven to improve water quality rate of cooling towers but has not been proven to improve the performance or effectiveness of cooling towers for an ozonation period of 15 days.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Josua Argha Prima
"Telah banyak penelitian dilakukan pada peralatan sistem pendinginan dengan tujuan mengurangi konsumsi energi, biaya perawatan dan biaya operasi. Chiller bebas minyak menggunakan kompresor dengan bantalan magnetik sebagai pengganti minyak pelumas dalam mengurangi kerugian dari gesekan. Kompresor dengan bantalan magnetik yang dibantu dengan pengatur kecepatan mampu bekerja lebih efisien dari kompresor pada umumnya. Dalam merancang sistem pendingin udara hemat energi, pemilihan sistem air dingin pada evaporator dan sistem air pada kondensor yang tepat adalah hal yang penting. Kondensor berfungsi untuk menolak panas dari chiller ke lingkungan, jumlah panas yang ditolak ke lingkungan bergantung pada lokasi menara pendingin, jenis pompa, sistem pemipaan, kualitas air dan sebagainya. Tujuan dari penelitian ini adalah untuk menganalisis sistem kondenser dan evaporator chiller di salah satu pusat perbelanjaan di Indonesia dan pengaruhnya pada kinerja chiller bebas minyak. Dari penghitungan diperoleh nilai NPSH available yang terhitung adalah -4.49 m yang lebih kecil nilai NPSH required adalah 5.6 m. Nilai NPSH yang kurang dapat menyebabkan kavitasi dan kerusakan pompa dan pipa. Selain itu, hal ini juga dapat menjadi penyebab menara pendingin di zona B bekerja dibawah spesifikasi 0.077 kW

Researchers have been conducting a lot of researches on cooling equipment in order to reduce their energy consumption, maintenance cost and operation cost. Oil-free chiller uses magnetic bearing compressor instead of lubricant to avoid friction loss from the bearing. In comparison of standard oil compressor, the motor with magnetic bearing with the help of Variable Speed Drive (VSD)  can run more efficiently at partial loads. In designing energy-efficient system air conditioning system it is important to not only choose a proper chilled water system but also condenser water system. The condenser rejects the heat from the chiller to the environment, the amount of heat rejected is depends on the style and location of the cooling tower, pump type, piping system, condenser water quality, etc. This research’s purpose is to analyse the current condenser system in one of shopping mall in Depok and how it effects the performance of the oil-free chiller. According to the calculation, NPSHa value is -4.49 m which is less than NPSHr. The lack in NPSHa value can cause cavitaton and damage to the pumps and pipes.  Moreover, this can be the reason why the cooling tower in Zone B run under the specification of 0.077 kW/Ton cooling tower."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Randa Kelvin
"Dalam dunia industri, menara pendingin merupakan salah satu peralatan yang digunakan sebagai sirkulasi air pendingin dalam berbagai industri. Penanggulangan kualitas air pendingin yang kurang memadai dapat menyebabkan mesin seperti unit heat exchanger akan mengalami korosi atau terbentuk kerak yang menyebabkan keefektifitasan menara pendingin berkurang. Penelitian ini bertujuan untuk mengetahui pegaruh penggunaan ozon terhadap efektifitas kinerja dan kualitas air menara pendingin sistem tertutup bertipe forced draft ndash; cross flow ndash; indirect/closed. Metode yang digunakan dalam penelitian ini adalah menyuntikkan ozon 3gr/hr ke dalam basin menara pendingin sistem tertutup dan melakukan uji laboratorium seperti AAS, Titrimetric, Gravimetrik, dan Spectrophotometric.
Hasil penelitian ini adalah kefektifitasan dari menara pendingin sistem tertutup setelah disuntikkan ozon memiliki nilai terkecil 6.6 dan nilai terbesar 26.7 Nilai Evaporation Loss nilai terkecil 0.03 m /h dan terbesar 0.119 m /h. Ozon terbukti mempengaruhi kualitas air pada basin menara pendingin sistem tertutup tetapi ozon belum dapat dikatakan mempengaruhi performa dari menara pendingin sistem tertutup dalam jangka 10 hari.

In the industrial world, cooling towers are one of the equipments used as cooling water circulation in various industries. Inadequate cooling water may cause the machine such as a heat exchanger unit becomes corrosion or crust formation which causes the cooling tower less effective. This study aims to determine the effect of using ozone based on performance and quality of the cooling tower with type forced draft cross flow indirect closed. 3g hr ozone is injected into closed system cooling tower as a method and conducted laboratory tests such as AAS, Titrimetric, Gravimetric, and Spectrophotometric.
As the result, the effectiveness of closed system cooling tower after ozone injection has the smallest value of 6.6 and the largest value of 26.7 . Evaporation Loss value of smallest value 0.03 m h and largest 0.119 m h. The role of ozone in closed system cooling towers affects water quality in the cooling system cooling basin but ozone does not affect the performance of the closed system cooling tower within 10 days.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yusmaniar
"Legionellosis is a collection of infection that emerged in the second half of the 2Oth century, and that are caused by Legionella pneumophila and related bacteria. Legionellosis consists of two clinical syndromes, Legionnaires?disease is characterisized by pneumonia and pontiac fever is self-limiting, influenza like illness. Outb According this study, the sensitivity of duplex PCR to detect Legionella pneumophila in sterile NaCl 0.9% is 2.8 CFU/ml. The sensitivity of the duplex PCR in seeded water samples are 62 CFU/400ml of tap water sample, 32 CFU/400ml of sterile distiiled water and 32 CFU/400 ml of sterile NaCl 0.9%. The culture method in this study can not recovered Legionella from seeded water samples. The presence of Legionella .spp and Legionella pneumophila in cooling tower water was investigated using the duplex PCR. Of 9 cooling tower water sample and 3 tap water sample, 8 were positive for Legionella spp, 1 were positive for Legionella pneumophila and 3 were negative. According detection Legionella in seeded water samples and cooling tower water, the culture method can not be used to recover Legionella, but the duplex PCR can be used as rapid detection for Legionella spp and Legionella pneumophila.

Legionella pneumophila merupakan penyebab utama lgionellosis yang mulai muncul pada pertengahan abad 20. Legionellosis dapat berkembang menjadi dua keadaan klinik, pertama Legionnares? disease yang merupakan penyakit multi sistem pneumonia, kedua Pontiac fever suatu penyakit mirip dengan flu dan dapat sembuh dengan sendirinya. Umumnya kasus legionellosis terjadi akibat dari kontaminasi pada sistem air panas maupun dingin pada gedung bertingkat seperti cooling tower, kondensor, spa, kolam renang, Oleh karena itu deteksi bakteri Legionellla pada sistem air di gedung bertingkat dan rumah sakit diperlukan untuk mencegah legionellosis nosokomial ataupun komunitas. Deteksi legionella dengan metode konvensional memerlukan media khusus dan waktu inkubasi yang lama. Pada penelitian ini duplex PCR dikembangkan untuk mendeteksi Legionella spp dan Legionella pneumophila pada sampel air cooling lower, dengan primer dari sekuens gen 16S rRNA unluk mendeteksi Legionella spp Serta primer sekuens gen nano untuk mendeteksi Legionella pneumophila. Pada penelitian ini Duplex PCR dapat digunakan untuk mendeteksi Legionella pneumophila dalam suspensi NaCl 0.9% hingga batas deteksi 2,8 CFU/ml. Hasil uji simulasi menggunakan sampel air yang ditambahkan pengenceran berseri Legionella pneumophila menunjukkan batas deteksi hingga 62 CFU/ 400 ml air kran, 32 CFU/400 ml akuadest steril dan 32 CFU/ 400 ml NaCl 0.9% stril. Hasil uji sirnulasi dengan metode kultur tidak menunjukkan pertumbuhan koloni pada agar BCYE plus. Hasil uji coba Duplex PCR terhadap 9 sampel air cooling tower dan 3 sampel air kran adalah satu sampel menunjukkan pita spesiiik L. pneumophia, 8 sampel yang menunjukkan pita spesifik Legionella spp dan 3 sampel negatif. Berdasarkan uji simulasi dan pemeriksaan sampel air cooling lower; metode kultur pada penelitian ini belum dapat mendeteksi keberadaan bakteri Legionella, sedangkan deteksi Legionella spp dan L. pneumophila dapat dilakukan dengan metode duplex PCR."
Depok: Universitas Indonesia, 2008
T32881
UI - Tesis Open  Universitas Indonesia Library
cover
New York: McGraw-Hill, 2012
628.162 WAT
Buku Teks  Universitas Indonesia Library
cover
Selviya Chandrika Avaurum
"Cooling tower atau menara pendingin sistem terbuka menggunakan air sebagai media untuk penukar kalor. Kerak dan alga akan muncul dan mengendap akibat kualitas air yang kurang baik sehingga proses pertukaran panas di dalam cooling tower kurang maksimal. Penggunaan chemical dinilai belum cukup efektif untuk mengatasi kerak dan lumut. Chemical juga menyebabkan iritasi pada kulit tubuh pekerja. Kutu air juga ditemukan pada air cooling tower yang diberi chemical. Alternatif dalam menjaga kualitas air cooling tower salah satunya adalah menggunakan ozon. Penelitian ini bertujuan untuk mengetahui pengaruh ozon terhadap kualitas air dan jumlah penghematan yang dapat dilakukan dengan menggunakan ozonasi. Penelitian ini menggunakan miniatur cooling tower satu sel dengan sistem terbuka yang berukuran 70 x 42,5 x 53 cm. Ozon diinjeksikan ke dalam air menggunakan injektor mazzei. Air yang telah bersirkulasi kemudian diuji kualitasnya menggunakan kalorimeter HACH DR900 dan uji laboratorium. Data yang dicatat dari penelitian ini adalah electric conductivity, total dissolved solid, pH, alkalinitas, Ca and Mg Hardness, Na, dan Cl. Perhitungan POSI didapatkan dengan cara memasukkan data-data yang sudah didapatkan untuk mengetahui kualitas air, memprediksi nilai Cycle of Concentration maksimum yang aman tanpa menyebabkan terjadinya kerak, dan menghitung blowdown rate untuk penghematan air. Hasil dari penelitian ini menunjukkan bahwa kualitas air yang diinjeksi ozon lebih baik daripada air yang tidak diinjeksi ozon karena maximum cycle dari air tersebut naik dari 10 cycle menjadi 10,3 cycle. Air sirkulasi yang diinjeksikan ozon juga terbukti mampu menjaga kualitas air karena dapat menurunkan nilai TDS dan electrical conductivity. Penghematan air yang dapat dilakukan sebesar 12,45% dibandingkan dengan air sirkulasi tanpa ozon.

Open system cooling towers use water as a medium for heat exchangers. Scale and algae will appear and settle due to poor water quality so the heat exchange process in the cooling tower is not optimal. The use of chemicals is considered not effective enough to overcome scale and moss. Chemical also irritates the skin of the worker's body. Water fleas are also found in water cooling towers that are treated with chemicals. One alternative to maintaining the quality of cooling tower water is using ozone. This study aims to determine the effect of ozone on water quality and the amount of savings that can be made by using ozone. This study uses a miniature one-cell cooling tower with an open system measuring 70 x 42.5 x 53 cm. Ozone is injected into the water using a Mazzei injector. The circulating water is then tested for quality using the HACH DR900 calorimeter and laboratory tests. The data recorded from this research are electric conductivity, total dissolved solid, pH, alkalinity, Ca and Mg Hardness, Na, and Cl. The POSI calculation is obtained by entering the data that has been obtained to determine water quality, predicting the maximum safe Cycle of Concentration value without causing scale, and calculating the blowdown rate for water savings. The results of this study indicate that the quality of water injected with ozone is better than water that is not injected with ozone because the maximum cycle of the water increase from 10 cycles to 10,3 cycles. Circulating water injected with ozone is also proven to be able to maintain water quality because it can reduce the TDS value and electrical conductivity. Water savings can be made of 12,45% compared to circulating water without ozone."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adityo Purwanto
"Menara pendingin adalah suatu unit yang dugunakan untuk proses pembuangan dalam sebuah sistem pendingin. Efektivitas thermal adalah suatu variabel yang sangat penting untuk menentukan hasil performa menara pendingin. Timbulnya korosi, lumut, dan presipitasi kerak dapat menghambat perpindahan panas sehingga dapat mengganggu tingkat efektivitas thermal dari menara pendingin tersebut. Bukan hanya mengurangi efektivitas termal saja, namun juga bisa merusak menara pendingin. Penelitian ini bertujuan untuk mengetahui pengaruh ozonasi terhadap faktor-faktor penghambat tersebut. Proses ozonasi ini diharapkan akan mengurangi pertumbuhan faktor-faktor tersebut. Metode yang dugunakan adalah dengan air pendingin dari basin disirkulasikan dengan sebuah sistem baru. Dalam sistem baru tersebut air dari basin akan disuntikan ozon, lalu air kembali ke basin. Selanjutnya sampel air akan di uji di laboratorium menggunakan metode AAS, Titrimetric, Gravimetric, Spectrophotometric untuk mengetahui kualitas air. Data yang didapat dari laboratorium adalah Ph, Konduktivitas Elektrik, TDS, Ca, Alkalinitas, Mg, Na, Cl. Data tersebut selanjutnya dimasukan kedalam penghitungan menggunakan metode Practical Ozone ScalingIndex dan Langelier Saturation Index untuk mengetahui kualitas air sirkulasi. Hasil yang didapat dari penelitian ini mununjukan bahwa aplikasi ozon dapat meningkatkan kualitas air dikarenakan TDS dan EC pada air siklus yang digunakan menurun. Jumlah konsentarasi siklus air yang aman digunakan pun meningkat dari 2 siklus menjadi 4 siklus.

cooling tower is a unit that is used for the disposal process in a cooling system. Thermal effectiveness is a very important variable to determine the performance of the cooling tower. The emergence of corrosion, moss, and crustal precipitation can inhibit heat transfer so that it can disrupt the level of thermal effectiveness of the cooling tower. Not only does it reduce thermal effectiveness, but it can also damage the cooling tower. This study aims to determine the effect of ozonation on these inhibiting factors. This ozonation process is expected to reduce the growth of these factors. The method used is with cooling water from the basin circulated with a new system. In the new system water from the basin will be injected with, then the water will return to the basin. Furthermore, water samples will be tested in the laboratory using the AAS, Titrimetric, Gravimetric, Spectrophotometric method to determine water quality. Data obtained from the laboratory are Ph, Electrical Conductivity, TDS, Ca, Alkalinity, Mg, Na, Cl. The data is then entered into the calculation using the Practical Ozone Scaling Index and Langelier Saturation Index method to determine circulating water quality. The results obtained from this study show that the application of ozone can improve water quality because TDS and EC in the cycle water used decrease. The amount of safe water cycle concentration is also increased from 2 cycles to 4 cycles."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>