Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 183625 dokumen yang sesuai dengan query
cover
Agus Indarto
"

Transformator tenaga merupakan bagian yang penting dalam sistem tenaga listrik yang berfungsi untuk mengubah tegangan dalam sistem transmisi dan distribusi. PD (partial discharge) merupakan parameter penting untuk menentukan kondisi kesehatan isolasi transformator. Proses penelitian dimulai dengan analisis kegagalan, investigasi pengaruh perekat silinder belitan, proses manufaktur dan disain isolasi antar belitan terhadap nilai PD. Sumber PD material isolasi padat berasal dari rongga, ruang kosong, ketidaksempurnan dan kelembaban. Sedangan pada isolasi cair berasal dari kelembaban, kandungan partikel dan gelembung. Hasil investigasi sumber PD adalah isolasi padat (63%), terutama silinder belitan (23%). Proses manufaktur yang mempengaruhi nilai PD adalah durasi pengeringan, durasi vakum dan peresapan minyak, serta tipe perekat pada silinder belitan. Durasi pengeringan yang optimum untuk mendapatkan nilai PD dibawah 70 pC, dipengaruhi oleh berat isolasinya. Durasi vakum dan impregnasi minyak yang optimum adalah 57 jam dan 75-120 jam. Sedangkan jenis perekat yang sesuai untuk mendapatkan nilai PD dibawah 70pC adalah tipe casein, karena struktur berporinya membuat peresapan minyak lebih baik. Hasil tersebut didukung oleh morfologi menggunakan Scanning Electron Microscopy. Hasil simulasi disain isolasi antar belitan menunjukan bahwa untuk mendapatkan nilai PD yang rendah, tidak hanya dengan menurunkan nilai aktual maximum stress voltage saja, namun harus dipertimbangkan juga voltage inception level.


Power transformer is important parts in an electric power system that change voltage in the transmission and distribution system. Partial discharge (PD) is crucial parameter to define the health condition of transformer insulation. The research process begins with the failure analysis, investigation adhesive type, manufacturing process and insulation design between winding to PD value. The sources of PD in solid insulation material come from void, cavity, impurity, and moisture. While in liquid insulation, it come from moisture, particle, and bubble. The investigation results showed that solid insulation is the highest value of PD source (63%), especially cylinder winding (23%). The manufacturing process that affect PD value are drying, vacuum, oil impregnation and adhesive usage on winding cylinder. To achieve PD below 70 pC, drying time is influenced by the insulation weight. Optimum vacuum and impregnation time are 57 and 75-120 hours. The type of adhesive to obtain PD value below 70 pC is the casein, due to its porous structure can make the oil absorb better. This result is supported by morphological analysis using Scanning Electron Microscopy. The result of insulation design between winding showed that to achieve low PD value, must be considered both reducing actual value of maximum stress voltage.

 Keywords— partial discharge; power transformer; manufacturing process; insulation design, adhesive

"
Depok: Fakultas Teknik Universitas Indonesia, 2020
D-pdf
UI - Disertasi Membership  Universitas Indonesia Library
cover
cover
Setyoadi
"Peluahan parsial/PD (Partial Discharge) merupakan permasalahan yang umum terjadi pada sistem isolasi mesin-mesin atau peralatan bertegangan tinggi. Pada mesin-mesin berputar (generator/motor), PD biasanya terjadi pada isolasi belitan yang terletak di dalam slot inti stator maupun di bagian belitan yang keluar dari inti stator (end winding). PLTP Gunung Salak memiliki 3 unit pembangkit listrik yang dioperasikan oleh Chevron sejak tahun 1997. Setelah dioperasikan selama kurang lebih 9 tahun, pada tahun 2006 untuk pertama kalinya pengecekan visual kondisi isolasi belitan stator generator dapat dilakukan. Hal yang menarik yang diketemukan pada saat itu adalah kerusakan akibat PD terjadi pada lapisan grading dan tingkat kerusakan yang berbeda antara ketiga generator tersebut.
Skripsi ini membahas mengenai analisa permasalahan PD yang terjadi pada isolasi belitan stator generator Unit-4 dengan melakukan analisa komparasi, trending, karakteristik, uji korelasi parameter operasi generator, dan bentuk aktual kerusakan fisik isolasi. Berdasarkan hasil analisa, proses fabrikasi yang kurang baik pada area overlap semikonduktif generator Unit-4 di duga menjadi akar penyebab PD mudah terbentuk pada bagian ini. Seiring dengan proses penuaan isolasi dan meningkatnya rata-rata suhu operasi air pendingin Unit-4 (dari 27 ke 290C), maka akselerasi aktifitas PD diperkirakan terjadi sehingga generator Unit-4 memiliki PD yang lebih tinggi bila dibandingkan dengan Unit-5 dan 6.

Partial Discharge (PD) is a common problem occurring on the insulation system of high voltage machines or equipment. In the rotating machineries (generators/motors), PD usually occurs on the winding insulation installed inside the stator slot or outside the stator core (end winding). PLTP Gunung Salak has 3 power plants which have been being operated by Chevron since 1997. After being in service for 9 years, in the 2006, thorough visual inspection on stator winding insulation could be performed for the first time. The interesting findings at that time were the damaged portion on the grading coating by PD and the different severity level among those three generators.
The focus in this study is to analyze PD problem on the generator Unit-4 winding insulation by conducting analysis of comparison, trending, characteristic, generator operation parameters correlation, and the actual physical damage on insulation. According to the analysis results, improper workmanship on semi conductive overlap layers during fabrication process is predicted to be the root cause that makes PD to be formed easily on this portion. Along with the insulation aging process and the increment of average operating temperature (from 27 to 29) on Unit-4 cooling system, it is suspected that PD activity is being accelerated and thus PD level on Unit-4 generator is higher than Unit-5 and 6.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S43022
UI - Skripsi Open  Universitas Indonesia Library
cover
Ardhyan Wisnu Murti
"Transformer adalah komponen vital yang memainkan peran utama dalam memasok daya ke konsumen, seperti perumahan, industri, dan kantor. Karena fungsinya yang vital, terdapat bagian penting dari trafo yaitu isolasi di mana isolasi adalah bahan yang memiliki sifat dielektrik sehingga sulit untuk mengalirkan listrik. Dalam isolasi, salah satu penyebab utama kegagalan isolasi adalah adanya fenomena peluahan sebagian, di mana nilai peluahan sebagian dapat digunakan sebagai parameter untuk mengetahui kondisi transformator. Pelepasan sebagian itu sendiri adalah peristiwa percikan listrik karena kegagalan isolasi parsial yang terjadi karena kontaminan dalam bahan isolasi. Salah satu jenis isolasi yang digunakan dalam pembuatan transformator adalah isolasi padat. Insulasi padat harus bebas dari keberadaan pori-pori udara dengan memasukkan minyak ke dalam pori-pori. Dalam penelitian ini, pengujian perekat yang digunakan dalam isolasi padat dilakukan untuk menentukan pengaruh variasi perekat pada nilai peluahan sebagian. Salah satu hasil yang diperoleh dari nilai pelepasan perekat tipe A adalah 398 pC sedangkan perekat tipe B adalah 55,8 pC. Hasil penelitian menunjukkan bahwa variasi perekat mempengaruhi nilai discharge parsial dan perekat tipe B lebih baik daripada perekat tipe A dalam hal nilai partial discharge.

Transformers are vital components that play a major role in supplying power to consumers, such as housing, industry and offices. Because of its vital function, there is an important part of the transformer which is insulation where the insulation is a material which has dielectric properties making it difficult to conduct electricity. In isolation, one of the main causes of isolation failure is the phenomenon of partial discharge, where the value of partial discharge can be used as a parameter to determine the condition of the transformer. Partial release itself is an electrical spark event due to a partial isolation failure that occurs due to contaminants in the insulating material. One type of insulation used in the manufacture of transformers is solid insulation. Solid insulation must be free from the presence of air pores by inserting oil into the pores. In this study, adhesive testing used in solid insulation was carried out to determine the effect of adhesive variations on the partial discharge value. One result obtained from the release value of type A adhesive is 398 pC while the type B adhesive is 55.8 pC. The results showed that the variation of the adhesive affects the value of partial discharge and type B adhesive is better than the type A adhesive in terms of the value of partial discharge.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Muhammad Husnul K.
"Generator sebagai salah satu komponen utama pembangkit, harus tetap berada pada kondisi terbaik. Kerusakan yang terjadi pada isolasi belitan stator merupakan hal yang paling dominan sebagai salah satu penyebab kerusakan pada generator. Adanya void pada belitan stator menyebabkan aktifitas peluahan parsial (Partial Discharge; PD). Kenaikan aktifitas PD yang terjadi dapat menyebabkan kegagalan operasi generator. Void pada belitan stator generator dapat menyebabkan kegagalan jika intensitas medan listrik yang bekerja melebihi kekuatan dielektrik dari void itu sendiri. Dalam hal ini, akan terjadi distribusi muatan yang tidak seimbang pada belitan stator generator. Penambahan temperatur belitan stator terjadi akibat perubahan nilai muatan bocor pada void tiap satuan waktu. Pengukuran PD dilakukan menggunakan alat diagnostik PD tech Power Engineering AG dan perangkat lunak MICAMAXXTM Plus. Berdasarkan pengamatan dalam studi kasus generator GT 1.2, terjadi PD pada setiap fasa dengan jenis PD yang terdeteksi adalah peluahan internal karena adanya void bagian isolasi utama belitan stator. Dari hasil perhitungan, usia efektif generator GT 1.2 diprediksi sampai dengan tanggal 8 Maret 2020.

Generator as a main component of power plant should be ensured that it always on its best condition. Deterioration of stator winding insulation is the predominant causes of generator failures. A void on stator winding causes partial discharge. The increasing of PD activity which is occurred may cause failure of generator operation. A void on stator winding may cause failure if electric field intensity which is working over than dielectric strength of itself. On this part, there will be unbalance charge distribution on stator generator. The additional temperature of stator winding occurred, because of the value changing of leak charge at the void in every time unit. PD Measurement is performed by using PD tech Power Engineering AG as a diagnostic tools and software MICAMAXXTM Plus. Based on the research in the case study of generator GT 1.2, PD is occurred on each phase with the PD's type which is detected as internal discharge because there is a void on the main insulation of stator winding. From the calculation result, the effective life period of generator GT 1.2 can be predicted until 2020, 8th March."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S-Pdf
UI - Skripsi Open  Universitas Indonesia Library
cover
Muhammad Hamdani Rizal
"Kualitas isolasi suatu belitan motor/generator tegangan menengah ataupun tegangan tinggi sangat perlu diperhatikan. Hal ini bertujuan untuk menghindari adanya kegagalan isolasi yang dapat berakibat besar terhadap suatu kegiatan produksi suatu industri atau pembangkit. Beberapa pengujian yang dilakukan untuk menentukan kualitas isolasi suatu belitan motor antara lain, pengujian tahanan isolasi, tan δ, dan pengujian tegangan tinggi.
Pada skripsi ini, pengujian tersebut dilakukan pada sebuah sampel belitan stator motor 6,6 kV yang belum terpasang pada stator. Material isolasi yang digunakan pada sampel belitan adalah mika, glass, kapton, polyester, dan varnish. Susunan lapisan material isolasi yang digunakan adalah standar kualitas isolasi belitan yang dapat mengampu tegangan kerja 6,6 kV.
Pengujian tahanan isolasi dilakukan sebelum dilakukan pengujian tegangan tinggi dan sesudahnya. Pengujian tahanan isolasi bertujuan untuk mengetahui besar kecilnya kandungan air pada isolator. Pengujian tan δ atau faktor disipasi untuk mengetahui besarnya rugi dielektrik bahan. Sedangkan pengujian tegangan tinggi bertujuan untuk mengetahui arus bocor yang timbul akibat tegangan tinggi yang diberikan pada belitan.
Dari ketiga pengujian tersebut, terdapat parameter tan δ yang tidak memenuhi standar. Akan tetapi, hal ini bukan merupakan faktor utama yang menentukan suatu isolasi belitan buruk. Besarnya nilai tahanan isolasi dan tidak adanya breakdown pada pengujian tegangan tinggi DC, merupakan faktor utama yang menentukan tahanan isolasi belitan adalah baik.

Insulation quality a medium or high voltage motor winding is an important aspect to be noticed. It aims to avoid the failure of the isolation that can result in the production activity of an industry or plant. Several tests were conducted to determine the quality of the insulation of a motor winding are like, insulation resistance testing, tan δ, and high voltage testing.
In this paper, the testing was conducted on a sample of 6.6 kV motor stator windings are not installed on the stator. Insulation materials used in sample entanglement is mica, glass, Kapton, polyester, and varnish. The composition of the insulating material used is a standard of quality that can administer the winding insulation working voltage of 6.6 kV.
Insulation resistance testing was performed before and after high voltage testing. Insulation resistance test aims to determine the size of the water content in the insulator. Testing of dissipation factor or tan δ, to determine the dielectric loss materials. While the high-voltage testing aims to determine the leakage current arising from a given high voltage on the windings.
Of the three tests, the tan δ are parameters that do not meet the standards. However, this is not a major factor that determines a bad winding insulation. The value of the insulation resistance and the absence of breakdown in high voltage DC testing, are the main factors determining the insulation resistance of the winding is good.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S52420
UI - Skripsi Membership  Universitas Indonesia Library
cover
Pungkie Oktharia Hermawan
"Pertumbuhan kelistrikan diproyeksikan akan terus meningkat seiring dengan program peningkatan rasio elektrifikasi dan pertumbuhan daerah perumahan yang akan terus menjamur di wilayah pinggiran kota mendorong peningkatan linear akan pemakaian kabel XLPE yang menjadi produk unggulan dalam sistem distribusi tegangan menengah. Meskipun menjadi unggulan, kabel XLPE masih memiliki permasalahan utama akan kegagalan isolasi yang berupa pemohonan listrik ataupun pemohonan air. Kedua masalah ini berawal dari adanya partial discharge, dimana dapat ditentukan oleh adanya kontaminan, seperti void (rongga udara) di dalam isolasi kabel. Dengan diadakannya type test oleh PT. PLN (Persero) PUSLITBANG Ketenagalistrikan pada kabel yang akan diproduksi, dimana pada mata uji pengujian partial discharge diperoleh hasil pengujian bahwa parameter ukuran kabel tidak mempengaruhi besarnya partial discharge, sedangkan parameter suhu memiliki pengaruh linear terhadap besarnya partial discharge terukur, selain itu terdapat faktor lain yang dapat mempengaruhi besarnya hasil pengujian.

Projected growth in electricity will continue to increase along with the electrification ratio improvement program and the growth of the residential area which will keep mushrooming in the suburb regions that will encourage linear increasing in use of the XLPE cable as a flagship product in the medium voltage distribution system. In spite of being seeded, XLPE cable still has the main problem against the insulation failure, namely electrical treeing or water treeing. Both these issues were derived from the existence of partial discharge, which can be determined by the presence of contaminants, such as voids (air cavity) in the cable insulation. As the type test that held by PT. PLN (Persero) PUSLITBANG Ketenagalistrikan on the cable that will be produced, in which the partial discharge test obtained the test results that the cable size parameter does not affect the partial discharge measured, whereas the temperature parameter has linear effect in partial discharge measured, in addition there are another factors that affect the partial discharge measured."
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42967
UI - Skripsi Open  Universitas Indonesia Library
cover
cover
Andrew Setiawan
"Partial discharge telah menjadi salah satu masalah yang sering terjadi pada peralatan dan peralatan listrik belakangan ini. Epoxy Resin sebagai sistem isolasi telah digunakan dalam penelitian ini karena keserbagunaannya. Penelitian ini memiliki dua tujuan yaitu menemukan pengaruh variasi frekuensi harmonik dan tingkat distorsi harmonik terhadap partial discharge sebagai tujuan yang pertama, sedangkan yang kedua adalah kita mencoba untuk menemukan efek rongga udara pada insulasi epoxy resin terhadap partial discharge.
Penelitian ini menggunakan dua jenis epoxy resin tanpa rongga udara dan dengan adanya rongga udara sebagai objek uji. Ada dua faktor yang divariasikan selama penelitian ini, yaitu distorsi frekuensi dan tingkat total distorsi harmonik. Pekerjaan ini memanfaatkan MATLAB sebagai alat untuk menghasilkan sinyal dan pemrosesan data. Terdapat empat parameter yang dianalisis untuk penelitian ini, meliputi Partial Discharge Inception Voltage, luas area partial discharge, tingkat pengulangan partial discharge dan distribusi fase partial discharge.
Hasil penelitian menunjukkan bahwa peningkatan distorsi frekuensi mengarah pada peningkatan luas area partial discharge dan tingkat pengulangan selama 1 siklus, sementara itu mengurangi Partial Discharge Inception Voltage. Adapun untuk distorsi harmonik total, tingkat THD yang lebih tinggi berkontribusi terhadap penurunan Partial Discharge Inception Voltage, tetapi meningkatkan luas area partial discharge. Dalam hal tingkat pengulangan, partial discharge lebih banyak terjadi pada kisaran 61° -120° untuk wilayah positif dan pada 241° -300° untukwilayah negatif. Selain itu, keberadaan rongga udara meningkatkan luas areapartial discharge dan tingkat pengulangan selama 1 siklus. Namun, menurunkan PDIV.

Partial discharge has been one of the problems that frequently occurs on electrical devices and equipment lately. Epoxy resins as an insulation system has been utilized in this research due to its versatility. This research has two objectives as finding the influence of variation of harmonic frequency and harmonic distortionlevel to partial discharge being the first one, while the second is we try to find the effects of air cavities in epoxy resin insulation to partial discharge.
It used twotypes of epoxy resins without void cavity and with the presence of void cavity asthe test object. There were two factors that were varied during this research, which were frequency distortions and total harmonic distortion levels. This workmade use of MATLAB as a tool to generate signals and data processing. Four parameters were analyzed for this research, those include Partial Discharge Inception Voltage, apparent charge area, partial discharge repetition rate andpartial discharge phase distribution.
The results showed that the increase offrequency distortion leads to the increase of apparent charge area and repetition rate for 1 cycle, while it decreases the Partial Discharge Inception Voltage. As forthe total harmonic distortion, higher levels contributes to the decrease of Partial Discharge Inception Voltage, but increases the apparent charge. In terms of charge numbers, the charges occurred more at the range of 61° 120° for the positivesequence and at 241° 300° for the negative sequence. In addition, the presence ofvoid cavity increases the apparent charges and repetition rate for 1 cycle. However, it decreases the PDIV.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>