Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 66748 dokumen yang sesuai dengan query
cover
Farhan
"Pemahaman kondisi reservoir merupakan salah satu aspek penting dalam aktivitas monitoring proses produksi fluida dalam sistem panas bumi. Langkah awal manajemen reservoir bagi Lapangan Panas Bumi FR yang baru berproduksi sejak tahun 2014 perlu dilakukan. Penelitian ini bertujuan mendelineasi reservoir khususnya fasa uap menggunakan metode tomografi waktu tunda. Penelitian ini menggunakan data seismogram yang diukur selama 95 hari yang direkam oleh 11 stasiun perekaman. Hasil picking waktu tiba mendapatkan 215 kejadian gempa mikro dengan minimal terekam oleh 3 stasiun perekaman. Distribusi hiposenter awal menunjukkan posisi episenter cenderung mengkluster pada sumur produksi akan tetapi dari segi kedalaman hiposenter masih terdapat fix depth pada elevasi 1170 masl, oleh sebab itu masih diperlukan proses relokasi hiposenter. Relokasi hiposenter dilakukan dengan dua metode secara kombinasi yaitu menggunakan metode Joint Hypocenter Determination (JHD) dan metode double difference. Selanjutnya dilakukan proses tomografi waktu tunda menggunakan perangkat lunak simulsp12.
Hasil distribusi relokasi hiposenter menunjukkan satu cluster di sekitar sumur produksi utama yaitu sumur B dan C. Sedangkan dari segi kedalaman hiposenter terdistribusi cluster disekitar trajectory sumur produksi B dan C dari elevasi 1000 sampai 0 masl dengan residual waktu tempuh antara 0.2 sampai 0.4 detik. Hasil tomogram menunjukkan bahwa pada elevasi sekitar 2000 sampai 1000 masl diduga sebagai zona batuan yang mengandung air dengan tingkat alterasi yang cukup besar yaitu zona clay cap dengan nilai VP/VS berkisar 1.73. Sedangkan dugaan zona uap berada pada elevasi 1000-500 masl dengan nilai VP/VS berkisar 1.67-1.7 melampar sepanjang Kawah Ciwidey dengan Kawah Putih. Selanjutnya dilakukan rekonstruksi model konseptual sederhana Lapangan Panas Bumi FR Jawa Barat dengan mengintegrasikan antara data utama penelitian yaitu tomografi microearthquake dan distribusi hiposenter yang sudah terelokasi dengan data pendukung berupa line penampang metode MT 2-D, section vertikal geologi berdasarkan data cutting sumur, profiling sumur temperatur serta lokasi sumur ekstraksi untuk memberikan arah fluida.

Understanding reservoir conditions is one of the important aspects in fluid production monitoring activity in geothermal systems. The initial step of reservoir management in the FR Geothermal Field which has only been producing since 2014 needs to be done. The object of this study to delineate the reservoir elemen especially the vapor phase using the tomography delay time method. This research used seismogram data measured for 95 days recorded by 11 seismometers. Arrivals time picking results get 215 micro earthquake events with a minimum recorded by 3 recording seismometers. The initial hypocenter distribution shows that the position of the epicenter tends to cluster in production wells but in terms of hypocenter depth there still fix depth at 1170 masl, therefore hypocenter relocation is still needed. Hypocenter relocation is done by two methods in combination. The first use Joint Hypocenter Determination (JHD) and second Double difference relocation method. Then the delay time tomography invers is using simulsp12 software.
The results of the hypocenter relocation distribution show one cluster around the main production wells that are wells B and C. While in terms of hypocenter depth distributed clusters around the trajectory of production wells B and C from elevations 1000 to 0 masl with a residual travel time of 0.2 to 0.4 seconds. The tomogram results show that at an elevation arround elevation 2000 to 1000 masl it is prediction that the zone containing water with a considerable alteration rate or usually calls of clay cap zone with a value of Vp / Vs ranging from 1.73. While the prediction steam zone is at an elevation of 1000-500 masl with a value of Vp / Vs ranging from 1.67-1.7 on the part between Ciwidey Crater and Putih Crater. The reconstruction of a simple conceptual model of West Java FR Geothermal Field by integrating the main data likes hypocenter distribution that has been relocated and microearthquake tomography with supporting data in the form of cross section MT 2-D method, geological vertical section based on well cutting data, profiling temperature wells and location of extraction wells to provide fluid direction.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Naraswari Probowati
"Menjadi suatu hal penting untuk melakukan manajemen monitoring lapangan panasbumi ldquo;H rdquo; yang telah produksi selama lebih dari 15 tahun. Penelitian ini bertujuan untuk mengidentifikasi reservoir terutama zona uap selama tahun 2014 dan tahun 2015 menggunakan tomografi MEQ. Relokasi events menggunakan Hypoellipse terhadap data MEQ tahun 2014 dan 2015 menunjukkan bahwa events MEQ terdistribusi membentuk dua klaster yaitu klaster Utara dan Selatan. Events di klaster Utara berada pada elevasi 500m ASL hingga 2 km BSL dan di Selatan pada elevasi 2 - 4 km. Kedalaman events MEQ tahun 2015 ternyata lebih dangkal daripada events tahun 2014. Selanjutnya direlokasi melalui metode Double-Difference menggunakan TomoDD dengan proses inversi simultan dan re-modelling 3-D Vp, dan Vs menggunakan inputan 1-D velocity dari wilayah lokal yaitu 1.6.
Hasil relokasi menunjukkan peningkatan kualitas data dengan nilai residual waktu tempuh mendekati 0 detik. Diketahui dari hasil inversi, terlihat adanya perubahan posisi kedalaman yang dihasilkan oleh tomoDD rata - rata berpindah secara horizontal dan lebih dalam 500m. Hasil tomogram menunjukkan bahwa dugaan zona uap mulai muncul pada kedalaman 1km ASL di bagian Utara sekitar Gunung Gambung yang kemudian meluas hingga kedalaman 2km BSL dengan nilai Rasio Vp /Vs yang rendah sekitar 1.2 - 1.4 km/s.

It is important to monitoring management of the H geothermal field which has been produced steam over 15 years. This study aims to identify reservoir, especially steam zones during 2014 and 2015 using MEQ tomography. The relocation of events using Hypoellipse shows that MEQ events are distributed to form two clusters of North and South. Events in the Northern cluster are at 500m ASL elevation to 2 km BSL and in the South at 2 ndash 4 km BSL elevation. The depth of events MEQ 2015 was shallower than events in 2014 then relocated through the Double Difference method using TomoDD with a simultaneous inversion and re modelling 3 D Vp, and Vs using 1 D seismic velocity from the local region of 1.6.
The relocation result shows the improvement of data quality with residual value of travel time reach to 0 second. From the inversion result, there is a change of position of depth generated by tomoDD generally move horizontally and deeper 500m. The tomogram results show that alleged steam zones begin to appear at elevation of 1km ASL on the Northern part of Mount Gambung to a depth of 2 km bsl with a low Vp Vs ratio of 1.2 to 1.4 km s.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T49200
UI - Tesis Membership  Universitas Indonesia Library
cover
Sinaga, Rebecca Putri
"Reservoir merupakan salah satu komponen utama pada sistem panas bumi. Fluida panas terakumulasi pada reservoir yang merupakan lapisan batuan permeabel. Metode Microearthquake dapat digunakan untuk mengetahui zona permeabel pada sistem panas bumi. Pengamatan hiposenter gempa-gempa mikro yang terjadi merupakan teknik yang cukup menjanjikan dalam mendeteksi zona permeabel pada sistem panas bumi. Penentuan hiposenter awal gempa mikro dilakukan dengan menggunakan metode Single Event Determination SED. Relokasi hiposenter gempa mikro dilakukan untuk mendapatkan lokasi hiposenter yang lebih akurat serta untuk mengurangi pengaruh kesalahan model kecepatan yang tidak sesuai dengan keadaan bawah permukaan yang kompleks.
Metode relokasi yang digunakan pada penelitian ini adalah Double Difference yang merupakan metode paling efisien, cepat dan menghasilkan error yang kecil serta tidak memerlukan koreksi stasiun. Data pemantauan aktivitas gempa mikro di lapangan panas bumi R yang digunakan ialah data sejak April 2012 hingga Oktober 2012 dengan menggunakan 18 stastiun pengukuran. Proses pengolahan data dilakukan dari data mentah berupa data time series. Distribusi hiposenter gempa mikro yang telah direlokasi kemudian dicocokkan dengan data pendukung berupa data MT dan Geologi.
Dari penelitian yang telah dilakukan didapatkan hasil bahwa pada daerah Selatan Gunung R terdapat aktivitas seismik dalam jumlah yang signifikan. Distribusi gempa mikro di daerah Selatan Gunung R membentuk klaster dan pattern patahan arah Barat Laut ndash; Tenggara. Sebaran titik hiposenter tersebut diinterpretasikan sebagai zona permeabel di bawah permukaan, dengan pattern patahan arah Barat Laut ndash; Tenggara sebagai pengontrol sistem panas bumi Gunung R.

Reservoir is one of the important components in geothermal system. Hot fluids are accumulated in Reservoir which is a thick layer of permeable rocks. Micro earthquake method can be used to identify the permeable zone in geothermal system. Observation of the micro earthquake hypocentres is a promising technique in detecting the permeable zone. The determination of the hypocentre is performed by using single event determination method SED Method. Micro earthquake hypocentre relocation is done to get more accurate locations and to reduce errors that happen because of the inaccuracy velocity model that is used.
Relocation method that is used in this research is double difference relocation which is the most efficient, fast and generating less error with no need of station correction. Data recording of micro earthquake activity in R geothermal Field that is used in this research are from June 2012 to October 2012 with 18 stations recording. The processing data starts from raw data which is time series data. The distribution of the hypocentre that has been relocated then matched to the supporting data which are MT and Geology data.
From the research that has been done, the result shows that there is a significant amount of seismic activity on the Southern part of Mount R. The distribution of micro earthquake form cluster and structure pattern NW ndash SE. The distribution of hypocentre can be interpreted as the permeable zone beneath the surface, with a NW SE fault pattern as the controller of the geothermal system on R geothermal field.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S67134
UI - Skripsi Membership  Universitas Indonesia Library
cover
Marpriansyah
"Lapangan panasbumi Wayang Windu sudah berproduksi dari tahun 2000 dengan memproduksikan uap sebanyak 227 MW. Selama masa produksi yang dilalui, terdapat beberapa masalah muncul dipermukaan terutama yang bekaitan dengan beberapa sumur 1 fasa di bagian utara lapangan Wayang Windu. Adapun permasalah yang ada diantaranya: penurunan produksi yang melebihi kondisi normal, penurunan tekanan reservoir yang mengkhawatirkan setiap tahunnya, dan indikasi peningkatan jumlah sumur superheat. Analisa yang dilakukan terbatas pada analisa produksi, logging sumur dan geokimia fluida geokimia terutama dari beberapa sumurdi bagian utara lapangan Wayang Windu. Selanjutnya semua data yang ada disandingkan dengan data Microearthquake MEQ, dan hasil monitoring data tracer injection yaitu untuk melihat keberadaan reservoir brine terhadap kinerja reservoir uap untuk kepentingan sustainability. Semua data yang dianalisa adalah data yang diperoleh dari tahun 2000 sampai 2017.
Penelitian ini diharapkan dapat memberikan informasi secara terintegrasil terhadap permasalahan terkini yang dihadapi, selanjutnya dapat diambil langkah perbaikan dalam upaya melakukan penerapan reservoir managemen yang lebih baik untuk kelangsungan produksi, sekaligus memberikan masukan terhadap bagaimana menerapkan strategi injeksi fluida brine/condensat untuk mempertahankan kinerja produksi dan peforma reservoir lapangan Wayang Windu terutama dalam upaya mempertahankan performa reservoir uap.

Geothermal Wayang Windu Wayang field has been produced since 2000 by producing 227 MW of steam in total. During the production period, there are some problems appearing on the surface especially those associated with 1 phase steam production at some wells in the northern of Wayang Windu field. The problems are decreasing production that exceeds of normal decline condition, decreasing significant reservoir per year, and increasing of number of superheat wells. The analysis are limited to production decline analysis based on steam production data, reservoir performance analysis from well record logging data, and geochemical fluid analysis from several 1 phase steam well at the northern part of Wayang Windu field. Furthermore, all existing data is juxtaposed with information from Micro Earthquake MEQ, and tracer injection data support to see the relationship between wells or reservoir and performance presence of the brine reservoir support for the production sustainability. All data were obtained from the surface record from 2000 but with focussed on mainly data obtained after the existence of Unit 2 in 2009.
This research is expected to provide complete integrated information on the latest problems encountered in the field of Wayang Windu, and furthermore it is expected to give some reccomendation for better good reservoir management improvement as part of maintaining the continuity of production in the future, as well as providing recommendation to how implement good strategy for brine condensate injection in order to maintain reservoir and well production performance at Wayang Windu Field.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T48816
UI - Tesis Membership  Universitas Indonesia Library
cover
Faris Maulana Yunus
"Wilayah geothermal Tulehu ditandai oleh kemunculan manifestasi permukaan. Tidak ada manifestasi yang mengindikasikan zona upflow. Survei geosains telah dilakukan dan diikuti oleh pengeboran 4 sumur eksplorasi. Namun, penggambaran zona upflow suhu tinggi yang terkait dengan sumber panas masih sulit. Hal ini karena area survei geosains yang dilakukan belum mencakup keseluruhan sistem geotermal (daerah upflow dan outflow). Dugaan keberadaan sumber panas kemungkinan menuju G. Eriwakang seperti yang ditunjukkan oleh distribusi temperatur dari data sumur. Berdasarkan studi data geosains yang tersedia, diintegrasikan dengan data sumur yang ada, maka dibuat model konseptual yang mencakup kemungkinan keberadaan sumber panas (zona upflow) di sekitar G. Eriwakang dan kemunculan manifestasi permukaan sebagai zona outflow. Untuk menyelidiki kemungkinan lokasi sumber panas sistem geotermal Tulehu, maka simulasi reservoir dilakukan berdasarkan model konseptual yang telah dibuat dengan menggunakan simulator TOUGH2/iTOUGH2. Hasil simulasi setelah mencapai kondisi natural state menunjukkan bahwa sumber panas dimungkinkan berada di bawah G. Eriwakang. Hal ini ditunjukkan dengan kesesuaian kurva temperatur vs kedalaman antara hasil simulasi dengan data sumur. Untuk mengkonfirmasi hasil penelitian ini, maka direkomendasikan untuk dilakukan survei geosains lebih lanjut.

Tulehu geothermal area is characterised by surface manifestations. Fumarole and other steam-type manifestations are absent. Geoscientific surveys covering thermal manifestations area have been conducted followed by exploration drillings. However, delineation of high temperature up-flow zone associated with heat source is still challenging, even drilling data from 4 wells could not answer the question yet. Possible existence of the heat source is likely toward Mt Eriwakang as indicated by temperature distribution from wells. Based on the geoscientitic data study, integrated with the existing well data, a conceptual model was developed that includes the possibility of the existence of a heat source (upflow zone) around G. Eriwakang and the appearance of surface manifestations as the outflow zones. To investigate the possible location of the heat source of the Tulehu geothermal system, reservoir simulations using TOUGH2/iTOUGH2 simulator were carried out based on the conceptual model that has been made. Simulation results, after achieving natural state conditions, indicate that the heat source is possibly located under Mt. Eriwakang. This is indicated by the suitability of the temperature vs. depth curve between the simulation results and the well data. Furthermore, to confirm the existence of the heat source, further geoscientific surveys are recommended to be carried out in this area."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fadhli Yusuf
"Permasalahan delineasi sistem geothermal adalah hal yang penting untuk dikaji, karena akan menentukan seberapa besar prospek panas bumi yang berada di subsurface. Metode magnetik bisa menentukan zonasi daerah di subsurface yang mengalami demagnetisasi akibat thermal. Batuan yang menjadi penyusun reservoir mengalami perubahan suseptibilitas dari tinggi ke rendah akibat pengaruh fluida dan panas dari heat source yang berada pada sistem tersebut.
Penelitian ini telah membuktikan keberadan delineasi sistem panas bumi Lapangan "E" dengan metode Magnetik dan Magnetotellurik, data magnetik sebanyak 674 titik dikoreksi dengan diurnal variation dan undistributed earth magnetic field atau lebih dikenal dengan IGRF. Setelah itu telah dilakukan kontinuasi hingga ketinggian 700 m asl, dan terlihat bodi yang berorientasi dipole dengan arah NE-SW pada inklinasi intermediet. Dilakukan Reduction to Pole pada hasil pengangkatan keatas dan didapatlah anomali low negatif yang mengindikasikan keberadaan hydrothermally demagnetization rock.
Hasil RTP juga dikorelasikan dengan kurva apparent resistivity MT, didapatkan nilai anomali low negatif cenderung berasosiasi dengan kurva MT tipe H. Kontur RTP dimodelkan dengan inversi 3D magnetik dan didapatkan zonasi reservoir berada dikedalaman mean sea level s/d 1900 m bsl. Cross korelasi pun dilakukan antara hasil Inversi 3D magnetik dan 2D Forward Modelling Magnetik serta inversi MT, bahwa zona batuan reservoir memiliki suseptibilitas sebesar 0.04-0.06 Cgs dan dengan resistivitas 20-80 ohm.m, Keberadaan reservoar panas bumi diduga berada di zona upflow hingga ke arah SW yang berada di sekitar sesar utama di daerah lapangan" E" yang berasosiasi dengan anomali low negatif sebesar-300 s.d -550 nT.

The delineation problem of the geothermal system is important to examine, as it will determine how big the geothermal prospects are in the subsurface. Magnetic methods can zonate the subsurface region undergoing thermal demagnetization processes. The rocks that make up the reservoir have changed the susceptibility from high to low due to the influence of fluid and heat from the heat source in the system.
This research has proved the existence of Geothermal Field 39 s delineation of Field E with Magnetic and Magnetotellurik method, 674 points magnetic data corrected by diurnal variation and undistributed earth magnetic field or better known as IGRF.After that continuity has been carried out to a height of 700 m asl, and visible dipole oriented body with NE SW direction in intermediate inclination. Reduction to Pole was performed on uplift and obtained a low negative anomaly indicating the presence of hydrothermally demagnetization rock.
The RTP results are also correlated with the apparent resistivity MT curve, and the low negative anomaly values tend to be associated with the Type H MT curve. The RTP contour is modeled by a 3D magnetic. And the reservoir zonation is in the mean sea level to 1900 m bsl. Cross correlation was performed between magnetic 3D Inversion and 2D Forward Modeling Magnetic and MT inversion, that reservoir rock zone has a susceptibility of 0.04 0.06 Cgs and with resistivity of 20 80 ohm.m The existence of geothermal reservoir is suspected to be in the upflow zone up to SW direction is in the vicinity of the main fault in the E field area associated with a negative low anomaly 300 s d 550 nT.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S67018
UI - Skripsi Membership  Universitas Indonesia Library
cover
Amallia Nadhiaratna
"ABSTRAK
Lapangan geotermal Sibayak berada di Sumatera Utara dengan ketinggian antara 1400 sampai 2200 m dengan keberadaan tiga vulkano aktif. Potensi dari lapangan geotermal Sibayak mencapai 40 MWe, namun saat ini kapasitas yang dieksplorasi baru mencapai 12 MWe. Area pemboran yang produktif berasosiasi dengan zona reservoir memiliki ciri yaitu area dengan temperatur dan permeabilitas tinggi. Daerah dengan permeabilitas tinggi ini biasanya disebabkan oleh banyaknya rekahan-rekahan. Pengukuran resistivitas dengan metode mise-a-la-masse merupakan cara yang dapat digunakan untuk mengetahui zona rekahan dengan permeabilitas tinggi. Data pendukung juga diperlukan seperti data geologi, geokimia, dan data sumur. Pembuatan model menggunakan metode inversi smoothness constrained least squares. Nilai resistivitas rendah menunjukkan adanya rekahan-rekahan bawah permukaan. Hasil yang diperoleh menunjukkan tiga zona permeabel yaitu high permeability di bagian utara sumur SBY-4 atau sekitar Gunung Sibayak, moderate permeability dekat sumur SBY-3 dan SBY-4, dan low permeability di bagian selatan dekat kaldera. Rekomendasi potensi lokasi sumur pemboran produksi berada di daerah upflow yang bertemperatur tinggi dan permeabilitas tinggi, yaitu di sebelah utara sumur SBY-4.

ABSTRACT
Sibayak geothermal field located in Sumatera Utara with elevation around 1400 until 2200m and surround by three active volcanoes. The potential of the Sibayak geothermal field reaches 40 MWe, but currently the explored capacity has only reached 12 MWe. Productive drilling areas associated with reservoir zones are characterized by areas with high temperature and permeability. This area with high permeability is usually caused by many fractures. Resistivity measurement using the mise-a-la-masse method is a method that can be used to determine the zone of fracture with high permeability. Supporting data is also needed such as geological, geochemical and well data. Modeling uses the smoothness constrained least squares inversion method. Low resistivity values ​​indicate the existence of subsurface fractures. The results obtained showed three permeable zones which is high permeability in the northern part of the SBY-4 well or around Mount Sibayak, moderate permeability near the SBY-3 and SBY-4 wells, and low permeability in the southern part near the caldera. The recommendation for the potential location of the production drilling well is in the high temperature and high permeability upflow area, which is to the north of the SBY-4 well."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yuasti Hasna Fauziyah
"ABSTRAK
Lapangan panas bumi Mataloko secara administratif terletak di Desa Todabelu, Kabupaten Golewa, Ngada, Nusa Tenggara Timur (NTT) dalam jarak 10 km ke timur-tenggara Bajawa, ibukota Ngada. Reservoir dangkal yang terletak di alterasi batuan diidentifikasi sebagai zona lempung. Pembentukan zona reservoir di zona lempung disebabkan oleh sesar normal Wae Luja yang melewati daerah ini, di mana sesar ini menyebabkan pembentukan fraktur di zona ini dan sebagai saluran masuknya cairan dari reservoir ke reservoir dangkal. model konseptual dimulai dengan menafsirkan data geosains (geologi, geokimia, geofisika). Langkah pertama adalah pemrosesan ulang data Magnetotelluric (MT) sebagai data utama. Kemudian diintegrasikan dengan hasil analisis data geologi, geokimia, geofisika untuk menghasilkan model konseptual. Model konseptual ini akan menjadi data input pada pemodelan numerik. Tahap kedua yaitu melakukan simulasi reservoir yaitu mengubah model konseptual menjadi model numerik. Pemodelan dilakukan dengan secara forward dengan software TOUGH2. Penelitian ini berhasil membuat model natural state lapangan Mataloko. Ketercapaian kondisi natural state ditunjukkan dengan adanya kesesuaian antara profil temperatur sumur dengan hasil pemodelan. Model natural state lapangan Mataloko agar dapat membantu untuk melakukan skenario pengembangan lapangan diantaranya perhitungan potensi, penentuan lokasi sumur produksi dan sumur injeksi, serta pemantauan kondisi reservoir selama masa eksploitasi.

ABSTRACT
Mataloko is geographically located in Golewa Subdistrict, Ngada Regency, East Nusa Tenggara Province, Indonesia The formation of the reservoir zones in claycap zone is caused by normal faults Wae Luja that pass through this area, where this fault which causes the formation of fractures in this zone and as a channel entry of fluid from the reservoir into the shallow reservoir. Geoscientific surveys covering thermal manifestations area have been conducted followed by exploration drillings. However, delineation of high temperature up-flow zone associated with heat source is still challenging, even drilling data from 2 wells could not answer the question yet. Development of conceptual model is started by interpreting geosciences data (geology, geochemistry, geophysics). The first step is reprocessing of Magnetotelluric (MT) data as the main data. It is then integrated with the analysis results of geology, geochemistry, geophysics data to generate a conceptual model. The TOUGH2 simulation uses the conceptual model in point 2 as input data, producing natural conditions that are calibrated with well data/compatibility curves (temperature data as a function of depth). Simulation results on well data show compatibility. This gives a strong indication that the center of the upflow is vertically below MT-3 and MT-4 and the outflow is in the northwest of the Mataloko Geothermal prospect area.
"
2019
T55287
UI - Tesis Membership  Universitas Indonesia Library
cover
Boy Raka Pratama
"Daerah Gunung Pancar merupakan daerah prospek geotermal yang didominasi oleh batuan sedimen, batuan beku berumur kuartener dan intrusi andesit. Sistem geotermal pada daerah ini ditandai dengan keberadaan manifestasi outflow berupa hotsprings yang memiliki temperatur berkisar 45-66°C. Dari data geokimia yang ada, reservoir pada daerah ini diperkirakan memiliki temperatur sekitar 180-215°C sehingga diklasifikasikan sebagai sistem geotermal dengan suhu yang rendah hingga menengah. Penelitan ini menggunakan metode magnetik untuk mengidentifikasi batuan yang mengalami demagnetisasi akibat terjadi proses alterasi hidrotermal yang diasosiasikan dengan batuan reservoir pada sistem geotermal.Dari data magnetik, dilakukan koreksi data dengan koreksi IGRF dan koreksi diurnal untuk menhasilkan peta kontur anomali magnetik total yang bersifat dipol. Proses reduction to pole (RTP) dan upward continuation dengan ketinggian sebesar 50 m, 100 m, dan 250 m untuk melihat nilai anomali rendah akibat demagnetisasi. Pemodelan secara forward 2 dimensi menunjukkan reservoir memiliki suseptibilitas yang rendah dengan nilai 0.000013 cgs pada kedalaman 500-1400 m di bawah permukaan laut. Kemudian, pemodelan secara inversi 3 dimensi menunjukan nilai suseptibilitas sekitar -0.003 hingga 0.035 cgs sebagai reservoir yang berada pada kedalaman 500-1300 m di bawah permukaan laut. Hasil pemodelan forward 2 dimensi dan inversi 3 dimensi dikorelasikan dengan model inversi 3 dimensi data AMT dan forward 2 dimensi data gravity. Dari hasil interpretasi terpadu, reservoir terletak di sekitar zona outflow pada kedalaman 500-1300 m di bawah permukaan laut.

The Gunung Pancar area is a geothermal prospect area dominated by sedimentary rocks, quaternary igneous rocks and andesite intrusion. The geothermal system in this area is characterized by the presence of outflow manifestations in the form of hotsprings which have temperatures ranging from 45-66 °C. From existing geochemical data, the reservoir in this area is estimated to have a temperature of around 180-215 °C so that it is classified as a geothermal system with low to medium temperatures. This research uses magnetic methods to identify rocks that have demagnetized due to hydrothermal alteration processes associated with reservoir rocks in geothermal systems. From magnetic data, data correction is done with IGRF correction and diurnal correction to produce a dipole total magnetic anomaly contour map. Reduction to pole (RTP) and upward continuation processes with a height of 50 m, 100 m, and 250 m to see the low anomaly values ​​due to demagnetization. 2-dimensional forward modeling shows the reservoir has a low susceptibility with a value of 0.000013 cgs at a depth of 500-1400 m below sea level. Then, 3-dimensional inversion modeling shows the susceptibility value around -0.003 to 0.035 cgs as a reservoir at a depth of 500-1300 m below sea level. The results of 2-dimensional forward modeling and 3-dimensional inversion are correlated with the 3-dimensional inversion model of AMT data and forward 2 dimensional gravity data. From the results of integrated interpretation, the reservoir is located around the outflow zone at a depth of 500-1300 m below sea level."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Vito Giovani Amin
"Metode gravitasi merupakan salah satu metode geofisika yang sudah umum digunakan dalam eksplorasi sistem panas bumi. Parameter yang terdeteksi berupa variasi nilai gravitasi yang menggambarkan distribusi densitas bawah permukaan. Dalam sistem panas bumi, batuan reservoir dapat dipetakan dengan metode gravitasi dikarenakan batuan reservoir memiliki densitas yang lebih rendah dibandingkan sekitarnya, sehingga menimbulkan anomali kontras densitas. Selain reservoir, struktur bawah permukaan juga akan teridentifikasi melalui peta residual, yang juga dikorelasikan dengan analisis derivatif berupa First Horizontal Derivative FHD , dan Second Vertical Derivative SVD. Melalui identifikasi patahan, zona recharge, zona discharge, serta daerah upflow dan outflow dapat dipetakan dengan lebih baik untuk merancang model konseptual sistem panas bumi. Kemudian dalam penelitian ini, sistem panas bumi akan dibuat model 3D inversi untuk penggambaran yang lebih jelas.

Gravity is a common geophysical method to be used in geothermal exploration. The detected parameter is the variation of gravity value, which represents the distribution of subsurface density. In geothermal system, we can detect reservoir rock with gravity method because the reservoir rock has a lower density rather than its surrounding which makes a contrast anomaly. For subsurface structures, the author will analyze it with derivative method FHD First Horizontal Derivative and SVD Second Vertical Derivative . Through subsurface structure identification, we can delineate the recharge and discharge area, together with uplow and outflow zone to design the geothermal conceptual model. Last but not least, the author will make a 3d inversion model for a better understanding."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>