cover
Saragih, Yuliasri
"Low dose computed tomography (LDCT) sangat baik digunakan dalam screening tetapi sangat sulit dalam mendeteksi adanya nodul. Penelitian ini dilakukan dengan cara membuat simulasi kgb di dalam paru (intrapulmonary lymph node) dan di daerah soft tissue. Simulasi kgb dimasukkan ke dalam gabus cork lalu disisipkan ke dalam 002LFC fantom CIRS toraks. Fantom tersebut dipindai dengan menggunakan 100 kV dan 120 kV pada 11, 25, 30, 50 mAs untuk LDCT dan 70, 80, 90, 100 mAs untuk SDCT. Hasilnya diperoleh bahwa terdapat perbedaan signifikan (p>0,05) antara nilai rata-rata SNR terhadap ukuran, bentuk dan komposisi IPLN pada low kV dan high kV. Jika dilihat secara visual, IPLN masih dapat dideteksi pada teknik LDCT dan SDCT untuk high kV maupun low kV sedangkan kgb pada soft tissue untuk LDCT khususnya pada 11 mAs dan 25 mAs untuk 100 kV dan 120 kV sangat sulit dideteksi dan SDCT pada 100 kV memiliki noise yang terlihat lebih besar dibandingkan pada 120 kV. Resolusi spasial citra dari MTF 10% yang terbaik didapatkan pada 120 kV, 30 mAs (LDCT). Kesimpulan dari penelitian ini adalah IPLN masih dapat dideteksi pada high kV, low kV untuk LDCT maupun SDCT sedangkan pada kgb yang berada di dalam soft tissue masih sulit untuk dideteksi pada low kV untuk LDCT.

Low Dose Computed Tomography (LDCT) is already well recognized for lung screening but it is still difficult to detect nodules. The lymph node simulations were put in the cork and paraffin then they both were inserted into the 002LFC CIRS thorax phantom. The phantom was scanned by using 100 kVp and 120 kVp at 11, 25, 30, 50 mAs for LDCT and 70, 80, 90, 100 mAs for SDCT. The results showed that there were significant (p>0,05)differences in average SNR values for varying sizes, shapes, and compositions of intrapulmonary lymph nodes (IPLNs). Visually, IPLNs could still be detected in LDCT and SDCT for high kVp and low kVp while lymph node in soft tissue for LDCT especially in 11 mAs and 25 mAs for 100 kVp and 120 kVp was very difficult to detect and the noise for 100 kVp SDCT technique was observed larger when compared to the 120 kVp SDCT. The best spatial resolution of images for 10% MTF is at 120 kVp, 30 mAs (LDCT). It can be concluded that IPLNs are still be able to detect at low and high kVp for LDCT and SDCT technique while lymph node in soft tissue is still difficult to detect at low kVp for LDCT."
2019
T54697
UI - Tesis Membership  Universitas Indonesia Library
cover
Emidatul Manzil
"Computed Tomography Dose Index (CTDI) merupakan konsep utama dalam dosimetri CT scan. Berdasarkan rekomendasi IAEA di TRS 457, CTDI dapat diukur di udara dan di fantom khusus CTDI. Ukuran dan massa fantom cukup besar sehingga akan menyulitkan dalam mobilisasi. Dalam penelitian ini dilakukan pengukuran CTDI untuk mengetahui faktor fantom pesawat Siemens Sensation 64. Faktor fantom adalah perbandingan CTDIw terhadap CTDIair. Fantom yang digunakan adalah fantom berbahan polymethil methacrylic (PMMA) berdiameter 16 cm sebagai fantom kepala dan 32 cm sebagai fantom tubuh. Detektor yang digunakan adalah Xi CT Platinum dan Xi Base Unit sebagai elektrometer. Estimasi dosis efektif dihitung berdasarkan nilai CTDIair pengukuran yang dikoreksi dengan perangkat lunak ImPACT CT Dosimetry Patient Calculator version 1.0.4. Nilai faktor fantom yang diperoleh untuk fantom kepala dan tubuh secara berturut-turut ialah 0.702 dan 0.357. Estimasi dosis efektif satu fase (rata-rata ± deviasi standar) ialah: kepala rutin 2.01 ± 0.11 mSv, kepala trauma 2.53 ± 0.16 mSv, thorak 3.4 2 ± 0.79 mSv, abdomen 5.99 ± 2.16 mSv, dan pelvis 2.12 ± 0.99 mSv. Faktor konversi DLP displai scanner terhadap dosis efektif: kepala rutin 0.0021 mSv/mGy.cm, kepala trauma 0.0022 mGy.cm, thorak 0.0182 mSv/mGy.cm, abdomen 0.0151 mSv/mGy.cm, dan pelvis 0.0118 mSv/mGy.cm.

Computed Tomography Dose Index (CTDI) is primary dosimetric concept in CT scan. Based on IAEA TRS 457 recommendation, CTDI can be measured free in air and by using phantom. Phantom size and mass are huge, thus it will complicate the mobilization. This research conducted CTDI measurement to find out the Siemens Sensation 64 phantom factor. Phantom factor is a ratio between CTDIw over CTDIair. A Polymethyl Methacrylic (PMMA) phantom was used in this research, which has 16 cm of diameter for head phantom and 32 cm of diameter for body phantom. The Xi CT Platinum detector was used in this research and Xi base unit is as an electrometer. The estimation of effective dose was calculated using CTDIair value and ImPACT CT Dosimetry Patient Calculator version 1.0.4. In this research was found out that the phantom factors are 0.702 for head phantom and 0.357 for body phantom. The estimation of effective dose for one phase (mean ± standard deviation): head routine 2.01 ± 0.11 mSv, head trauma 2.53 ± 0.16 mSv, thorax 3.4 2 ± 0.79 mSv, abdomen 5.99 ± 2.16 mSv, and pelvis 2.12 ± 0.99 mSv. DLP on scanner display to effective dose conversion factors: head routine 0.0021 mSv/mGy.cm, head trauma 0.0022 mSv/mGy.cm, thorax 0.0182 mSv/mGy.cm, abdomen 0.0151 mSv/mGy.cm, and pelvis 0.0118 mSv/mGy.cm."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2011
S1242
UI - Skripsi Open  Universitas Indonesia Library
cover
Samsun
"Perkiraan nilai dosis yang diterima pasien ( CTDI ) yang langsung ditampilkan pada monitor CT setiap selesai pemeriksaan akan diketahui ketepatan nilainya dengan pengukuran langsung menggunakan pencil ion chamber dan pengukuran tidak langsung menggunakan TLD (Thermolumescence Dosimeter ) yang ditempatkan pada objek phantom dan dibandingkan dengan nilai dosis referensi yang telah ditetapkan, sehingga diharapkan mendapatkan informasi nilai dosis yang sebenarnya.
Analisis variasi parameter kV, mAs, dan pitch untuk menentukan berapa rentang nilai parameter optimum untuk mendapatkan nilai dosis pasien (CTDI/mAs) yang minimum namun tidak mengesampingkan kualitas pencitraan hasil CT. Scan yang baik guna menunjang diagnosa, pengukuran langsung maupun tidak langsung dengan menggunakan fantom kepala dan perut.
Pengukuran tidak langsung dengan menggunakan TLD (Thermolumescence Dosimeter ) pada menunjukan hasil yang tidak jauh berbeda dengan pengukuran langsung dengan menggunakan pencil ion chamber, dapat ditunjukkan dengan hubungan sifat kelinearan antara pitch dan dosis (CTDI/mAs).

An estimation dose (CTDI) received by the patient which is directly displayed on the CT monitor on every examination will be able to known it?s precisien by direct measurement using pencil ion chamber and the indirect measurement using TLD placed on the object (phantom) and compared with the value of dose reference, so the real dose rate will be known.
The variant analysis of kV, mAs and pitch parameters to justify the range of optimal parameter value, it is used to get the minimum patient dose rate (CTDI/mAs) while the image quality for supporting the diagnose still on the right value, directly or not directly using head and abdomen phantom.
Indirect measurement using TLD show unsignificant result if compared with the ion chamber. This value is shown by a relative variant parameter using stright pitch and dose ( CTDI/mAs).
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2008
T21548
UI - Tesis Open  Universitas Indonesia Library
cover
Ristania Nodya
"Computed Tomography (CT) Scanner merupakan alat pencitraan diagnostik yang memberikan informasi citra medis untuk menunjang pengobatan pasien, namun tanpa disadari pemanfaatan radiasinya dapat menimbulkan efek negatif pada organ sensitif sekitar. Penelitian ini dilakukan untuk mengukur dosis organ sensitif (mata, tiroid, dan payudara) menggunakan fantom Rando pada CT Scanner area thorax. Untuk memudahkan penelitian ini, TLD rod 100 digunakan sebagai dosimeter, dimana kV dan pitch dijadikan sebagai variasi parameter penelitian. Hasil menunjukkan bahwa nilai paparan dosis tertinggi pada tiap kualitas berkas berturut-turut dari 80, 120, dan 140 kV yaitu payudara kanan (1,72±0,34 mGy), tiroid kanan (6,25±0,16 mGy), dan payudara kiri (10,78±0,76 mGy). Pada variasi pitch nilai paparan dosis tertinggi secara berturut-turut dari 4, 6, dan 8 yaitu payudara kiri (6,19±0,02 mGy), tiroid kanan (6,25±0,16 mGy), dan payudara kanan (5,08±0,85 mGy). Dapat disimpulkan bahwa nilai dosis payudara pada CT Thorax lebih tinggi dibandingkan dengan mamografi, namun keduanya tidak melebihi nilai batas dosis yang ditetapkan International Commission on Radiological Protection (ICRP) yaitu 5 Gy.

Computed Tomography (CT) Scanner is an instrument of medical imaging using radiation to support treatment for patient, but the radiation may give a negative effect around sensitive organs. The research meant to measure dose for sensitive organs at thorax area (eyes, thyroid, and breast) using CT Scanner with rando phantom as an object. To ease this experiment, TLD rod 100 used as dosimetry, which kV and pitch as a parameter variation. The result showed that the highest dose for kV variation upon each sequent beam quality from 80, 120, and 140 kV are right breast (1,72±0,34 mGy), right thyroid (6,25±0,16 mGy), and left breast (10,78±0,76 mGy). Towards pitch variation the highest exposure dose value in sequently from 4, 6, and 8 are left breast (6,19±0,02 mGy), right thyroid (6,25±0,16 mGy), and right breast (5,08±0,85 mGy). As a conclusion, the dose on breast from CT Thorax is higher than the one from mammography but both are bellow dose value limit from International Commission on Radiological Protection (ICRP) which is 5 Gy."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S58757
UI - Skripsi Membership  Universitas Indonesia Library
cover
Joni S. Kadir
"Tujuan penelitian ini adalah untuk melakukan pengukuran CTDI dan dosis efektif pada 3 mesin CT dengan pengujian abdominal terhadap pasien pediatrik dan dewasa menggunakan phantom CT yang dibuat dan detector pensil CT serta electrometer RADCAL. Phantom CT dibuat berdasarkan standar US-FDA untuk CT. Pengujian Computed Tomography (CT) yang dilakukan menggunakan 2 CT phantom yang berbeda, diameter 32 cm (pasien dewasa) dan diameter 16 cm (pasien pediatrik). Pengukuran CTDI dan perhitungan dosis efektif radiasi menunjukkan bahwa terdapat dosis pasien pediatrik yang lebih tinggi signifikan dibandingkan dengan dosis pasien dewasa pada perlakuan yang sama. Hal ini menandakan pentingnya penentuan secara hati-hati parameter teknis scan dan justifikasi yang kuat terhadap penggunaan pengujian CT pada pasien pediatrik.

A study has been performed to measure CTDI and effective dose on 3 CT machines pertinent to abdominal examination to adult and pediatric patients using fabricated CT phantom and RADCAL pencil detector and electrometer. The CT phantom was tailored according US-FDA standard. Computed tomographic (CT) examinations have been performed using two different CT phantoms, 32 cm (adult) and 16 cm (pediatric) diameter. Computed tomographic (CT) examinations and radiation effective dose showed significant higher pediatric dose as compared to adult patient dose at the same examinations. This indicates the importance of careful selection of technical scan parameters and strong justification of the use of CT examination on pediatric patient."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2006
T20863
UI - Tesis Membership  Universitas Indonesia Library
cover
Nadya Lailyshofa
"ABSTRACT
MVCT merupakan modalitas pencitraan yang diintegrasikan dengan pesawat Tomoterapi menggunakan energi 3.5 MV yang memiliki andil cukup besar untuk memberikan tindakan terapi yang optimal pada Tomoterapi. Tujuan dari penelitian ini adalah mengevaluasi kualitas citra, estimasi dosis, serta verifikasi posisi pada pencitraan MVCT. Dalam penelitian ini, evaluasi MVCT dilakukan dengan tiga variasi mode slice thickness yaitu fine, normal, dan coarse. Pengujian kualitas citra dilakukan menggunakan phantom Cathpan 600. Estimasi dosis dan verifikasi posisi dilakukan menggunakan phantom Rando pada tiga area yang ditentukan, yaitu head neck, thorax, dan pelvic. Verifikasi posisi dilakukan dengan memberikan beberapa marker eksternal di beberapa titik pada setiap area dan dihitung dengan bantuan dua perangkat lunak, yaitu software Tomoterapi dan 3D Slicer. Hasil evaluasi kualitas citra yang diperoleh menunjukkan bahwa seluruh variasi mode slice thickness pada MVCT masih berada dalam batas toleransi sesuai dengan AAPM TG 148. Estimasi dosis yang diperoleh menunjukkan bahwa dosis terbesar diperoleh pada mode fine. Secara umum, nilai estimasi dosis yang diperoleh berada pada rentang 1-4 cGy untuk semua area pada setiap titik OAR yang diukur. Pergerakan posisi yang diperoleh untuk seluruh variasi mode slice thickness menunjukkan perbedaan yang tidak signifikan, dengan besar le; 0.5 mm. Perbedaan hasil pergerakan posisi yang diperoleh antara dua software yang digunakan tidak lebih dari 0.5 mm.

ABSTRACT
MVCT is an imaging modality which is integrated by Tomotherapy using 3.5 MV energy that has a large enough contribution to provide an optimal therapeutic in Tomotherapy. The purpose of this study is to evaluate the image quality, dose estimation, and verification of the position on MVCT imaging. In this study, MVCT evaluation was performed with three variations of the slice thickness mode that is fine, normal, and coarse. Image quality testing was performed using Catphan 600 phantom. Dose estimation and position verification were performed using Rando phantom in three areas, there were head neck, thorax, and pelvic. Verification of the position was performed by providing several external markers at several points in each area and calculated with the help of two software, namely Tomotherapy software and 3D Slicer. The result of image quality evaluation obtained shows that all variations of slice thickness mode in MVCT are still within tolerable limits in accordance with AAPM TG 148. Estimated dose obtained shows that the largest dose was obtained in fine mode. In general, the estimated dose value which was obtained is in the range of 1 4 cGy for all areas at each measured OAR point which was measured. Movement of position obtained for all variations of slice thickness mode shows insignificant difference, with value le 0.5 mm. The difference of result obtained between the two software used is no more than 0.5 mm."
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sihaloho, Florensa
"Tujuan
Untuk mendapatkan data metastasis KGB retrofaring pada penderita KNF dengan
pemeriksaan CT nasofaring di Rumah Sakit Kanker “Dharmais”.
Metode
Penelitian studi deskriptif analitik dari data sekunder CT nasofaring penderita
KNF yang belum mendapatkan terapi radiasi dan kemoterapi. Penilaian metastasis
KGB retrofaring dengan diameter aksial minimal ≥ 5 mm yang berada di level
atlas dekat arteri karotis interna. Penilaian massa tumor menurut TNM AJCC edisi
ke-7 tahun 2010. Dilakukan uji statistik untuk mengetahui adanya hubungan
metastasis KGB retrofaring dengan massa tumor, tipe histopatologi, invasi lateral,
dan massa tumor melewati midline.
Hasil dan diskusi
Sebanyak 85 penderita KNF dengan subyek terbanyak laki-laki, umur rerata 43,2
tahun, metastasis KGB retrofaring sebanyak 81 subyek, dan metastasis KGB
servikal level II merupakan metastasis KGB terbanyak.
Kesimpulan
Metastasis KGB retrofaring adalah metastasis KGB terbanyak kedua setelah KGB
servikal level II. Kedua metastasis KGB ini merupakan drinase pertama metastasis
KGB pada KNF.

Objectives
To get the data retropharyngeal lymph node metastatic in NPC patients with
nasopharyngeal CT examination in Dharmais Cancer Hospital.
Methods
Analytic descriptive study using secondary data from nasopharyngeal CT
examination of NPC patients who had not received radiation therapy and
chemotherapy. Assessment of retropharyngeal lymph node metastatic with
minimal axial diameter ≥ 5 mm at the level of the atlas near the internal carotid
artery. Tumor mass assessed according to the AJCC TNM 7th edition in 2010.
Performed statistical tests to determine the relationship retropharyneal lymph
node metastatic with tumor mass, histopathologic type, lateral invasion, and
tumor mass through the midline.
Result and discussion
A total of 85 patients with NPC most male subjects, mean age 43.2 years, 81
patients with retropharyngeal lymph node metastatic, and level II cervical lymph
node metastatic is the highest.
Conclusion
Retropharyngeal lymph node metastatic is the second highest after level II
cervical lymph node metastatic. Both of these lymph node metastatic is the first
drainage lymph node metastastic in NPC.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2013
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Maulianti
"Citra Cone Beam CT (CBCT) sangat berperan dalam menentukan keberhasilan verifikasi posisi pasien radioterapi, oleh karena itu jaminan kualitas sistem CBCT sangat diperlukan. Percobaan ini dilakukan dengan menggunakan pesawat Linear accelerator yang dilengkapi dengan CBCT dan CT Simulator GE Bright Speed Edge. Fantom Catphan® 600 dan CBCT Electron DensityTM digunakan untuk menilai kualitas dari citra CBCT dan linearitas CT Number. Sesuai dengan uji kualitas, citra pada CBCT hanya dapat membedakan kontras rendah dan kontras tinggi (udara, jaringan dan tulang).
Hasil uji ketebalan slice menunjukkan nilai yang didapat masih dalam batas toleransi ±0.5 mm. Pada uji kontras rendah bagian supra-slice untuk target kontras 1%, 0.5%, dan 0.3% nilai konstantanya sebesar 3, 2.5, dan 4.5, sedangkan pada bagian sub-slice untuk target kontras jarak 7, 5, dan 3 mm memiliki nilai konstanta 5 mm. Hasil pengujian resolusi tinggi pada CBCT dan CT Simulator adalah 3 lp/cm dan 7 lp/cm. Hasil pengujian uniformitas pada CBCT tidak memenuhi standar dari batas toleransi rata-rata CT Number tepi dan tengah kurang dari 5 HU, dan nilai setiap titik tepi dan tengah ±2 HU.

Cone Beam Computed Tomography (CBCT) image is very important in verification of patient positioning in the treatment couch radiotherapy machine so quality control of the system is required. The experiment was performed using the Linear accelerator with equipped with CBCT and CT simulator GE Bright Speed Edge. Catphan® 600 and CBCT Electron DensityTM phantom was used to evaluate the quality of CBCT and CT Number linearity. According to the image quality test, the CBCT image only be able to distinguish low contrast and high contras for air, tissue and bone.
Quantitavely, the slice thickness was in tolerance limit ±0.5 mm, low contrast with constant value of 3, 2.5, dan 4.5 for supra-slice contrast targets 1%, 0.5%, dan 0.3% whereas sub-slice targets axis lenghts for 3, 5, and 7 mm with constant value of 5 mm, the high resolution appear in 3 lp/cm and 7 lp/cm for CBCT and CT simulator, respectively. On the one hand, CBCT uniformity was out of tolerance limit with average CT number edge and central less than 5 HU, and ±2 HU for the edge and center point.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S45532
UI - Skripsi Membership  Universitas Indonesia Library
cover
Septi Purwaningsih
"[ABSTRAK
Penelitian ini bertujuan untuk mengetahui profil dosis sinar-x Computed
Tomography dengan variasi pitch menggunakan film Gafchromic XR QA2 dan
TLD pada fantom kepala orang dewasa dan kepala pediatrik. Untuk tujuan
tersebut dilakukan pengukuran dan analisis profil dosis di sepanjang sumbu z
rotasi scan pada pusat fantom dan beberapa tepi di kedalaman 1 cm, analisis profil
dosis pada posisi yang sama dengan nilai pitch yang berbeda, dan analisis profil
dosis pada kepala orang dewasa dan kepala pediatrik. Dari pengukuran dan
analisis data diperoleh hasil profil dosis pada scan kepala orang dewasa dan
kepala anak-anak dengan nilai dosis maksimal di tengah, menurun pelan ke arah
tepi dengan tendensi cenderung simetri. Profil dosis dengan variasi nilai pitch,
diperoleh nilai dosis yang semakin menurun dengan bertambahnya nilai pitch.
Profil dosis pada scan kepala orang dewasa memiliki nilai dosis lebih besar dari
pada dosis pada scan kepala pediatrik, karena scan kepala orang dewasa
menggunakan mAs lebih besar. Hasil pengukuran menggunakan TLD diperoleh
data yang bersifat disktrit, namun memiliki pola distribusi dan nilai dosis yang
hampir sama dengan hasil dari pengukuran menggunakan film Gafchromic. Hasil
pengukuran profil dosis menggunakan film Gafchromic didapatkan grafik
kontinu. Nilai dosis maksimum hasil scan didapatkan pada posisi jam 12 dan
minimum pada posisi jam 6. Profil dosis pada pitch 0,75; 1 dan 1,5 mengalami
fluktuasi dosis dengan amplitudo pada pitch 0,75 dan 1,5 mempunyai nilai yang
lebih besar jika dibandingkan dengan amplitudo pada pitch 1.

ABSTRACT
This research aims to check pattern dose profile on the adult and pediatric
head scan. Comparing result measurement dose profile along the z- axis rotation
at a depth 1 cm and center phantom with variety pitch. Measurement using
cylinder PMMA homogeneous phantom diameter 16 cm and 10 cm using XR
QA2 Gafchromic film and TLD. Result of research get dose profile adult and
pediatric head scan have same pattern, the maximum dose in the middle and
tendency symmetry in the edge. Value dose proportional with value of pitch. Dose
in the adult head more than dose pediatric head because dose in adult head scan
using bigger mAs. Dose of TLD measurement values obtained are discrete, but
has a distribution and dose values are almost the same as the measurement results
in XR QA2 Gafchromic film. Result of Gafchromic film measurement is continue
graphic. The maximum dose of the scan results at the 12 o'clock position and
minimum at 6 o'clock position. Result of research get fluctuated dose and
amplitude of pitch 0.75 and 1.5 have greater than amplitude pitch 1., This research aims to check pattern dose profile on the adult and pediatric
head scan. Comparing result measurement dose profile along the z- axis rotation
at a depth 1 cm and center phantom with variety pitch. Measurement using
cylinder PMMA homogeneous phantom diameter 16 cm and 10 cm using XR
QA2 Gafchromic film and TLD. Result of research get dose profile adult and
pediatric head scan have same pattern, the maximum dose in the middle and
tendency symmetry in the edge. Value dose proportional with value of pitch. Dose
in the adult head more than dose pediatric head because dose in adult head scan
using bigger mAs. Dose of TLD measurement values obtained are discrete, but
has a distribution and dose values are almost the same as the measurement results
in XR QA2 Gafchromic film. Result of Gafchromic film measurement is continue
graphic. The maximum dose of the scan results at the 12 o'clock position and
minimum at 6 o'clock position. Result of research get fluctuated dose and
amplitude of pitch 0.75 and 1.5 have greater than amplitude pitch 1.]"
2015
T43843
UI - Tesis Membership  Universitas Indonesia Library
cover
Siti Nur Hidayati
"Penelitian ini menggunakan fantom abdomen in house dengan tujuan mengukur dosis di berbagai daerah organ yaitu hepar, ginjal, reproduksi dan bladder. Pengukuran dosis pada daerah organ dilakukandengan menggunakan dosimeter gafchromic dan TLD. Selain itu penelitian ini bertujuan untuk mengetahui profil dosis sepanjang sumbu-z dan image quality dengan variasi pitch factor. Faktor eksposi yang digunakan disesuaikan dengan aplikasi klinis abdomen yaitu 130 kV, 80 mAs, rotation 1.5 s dan delay 3 s. Pemilihan parameter pitch factor pada pemeriksaan CT abdomen akan mempengaruhi nilai dosis dan image quality. Variasi Pitch factor yang digunakan 0,8; 1 dan 1.5. Secara umum pengukuran dosis dengan gafchromic dan TLD di berbagai daerah organ memperlihatkan bahwa semakin besar penggunaan pitch factor maka dosis yang didapatkan semakin kecil. Profil dosis sepanjang sumbu-z berbentuk parabola yang simetris dengan dosis maksimum di sekitar 3.45 mGy dan dosis minimum pada awal dan akhir scanning sekitar 3.286 mGy. Hubungan nilai SNR dan slice untuk ketiga nilai pitch 0.8, 1 dan 1.5 pada umumnya sinusoidal dan untuk obyek di daerah kanan dan kiri menunjukkan kurva yang berbeda fase. Demikian juga antara dua titik atas dan bawah. Pengukuran kesesuaian antara citra obyek dengan ukuran obyek sebenarnya dari 512 data diperoleh hasil pada pitch factor 0.8 deviasi diameter 0 ndash; 5 sekitar 50.5 dan selebihnya 49.5 deviasinya diatas 5 . Pada pitch factor 1 deviasi 0 ndash; 5 sekitar 53.5 dan deviasi lebih dari 5 sekitar 46.7 , sedangkan untuk pitch factor 1.5 deviasi 0 ndash; 5 sekitar 68 dan deviasi lebih dari 5 sekitar 32.

This study uses in house phantom abdomen with the aim of measuring doses in different regions of the organ namely liver, kidney, reproduction and bladder. Measurement of dose in the organ region is done by using gafchromic and TLD dosimeter. In addition, this study aims to determine the profil dose along the z axis and image quality with variation of pitch factor. The exposure factors were adjusted for the clinical application of abdomen 130 kV, 80 mAs, rotation 1.5 and delay 3 s. Selection of pitch factor parameters on abdominal CT examination will affect the dose value and image quality. Variation of pitch factor used 0.8 1 and 1.5. In general, Measurements dose with gafchromic and TLD in different organ regions showed that the greater the use pitch factor the smaller the dose. Profil doses along the z axis are parabolic shapes symmetrical with maximum doses about 3.450 mGy and minimum doses at the start and end of scanning around 3.286 mGy. The relation of SNR and slice values to the three pitch values 0.8 1 and 1.5 is generally sinusoidal and for the object in the right and left regions show different curves of phase. Likewise between the two points above and below. Measurement of conformity between object image and actual object size from 512 data obtained result on pitch 0.8 deviation of 0 ndash 5 diameter around 50.5 and 49.5 deviation over 5 . In pitch factor 1 deviation 0 ndash 5 about 53.5 and deviation more than 5 about 46.7 , while for pitch factor 1.5 deviations 0 ndash 5 about 68 and deviation more than 5 about 32 ."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T49770
UI - Tesis Membership  Universitas Indonesia Library